Features

  • Single– and three–phase protection
  • Locked rotor protection
  • Thermal protection
  • Neutral tap
  • Meets thermal protection requirements of MIL-M-7969, direct acting PERFORMANCE CHARACTERISTICS Maximum Current Ratings

28 VDC 120 VAC

Standard ratings are available in approximately 5% current steps at ultimate trip for motors with maximum allowable temperatures of 120°C, 150°C, 175°C, and 200°C. Ratings are for device series. Specific devices may vary.

www.sensata.com Page 2 Copyright © 2018 Sensata Technologies, Inc. APPLICATION STANDARD CONFIGURATIONS Inherent protection means that a protector is built into a motor and becomes an integral part of the system. For this reason, Klixon® protectors should only be applied by the motor manufacturer after detailed application tests to determine the heating characteristics of the motor under a full range of load and ambient conditions to verify the selected rating will meet the specific application requirements. Consult the factory for test samples. Single Phase Motor Protectors Open Type SKA MKA Approx. Weight (Ounces) .125 .250 Maximum Rapturing Capacity 16 amps 50 amps A (max dia) .688 .937 B (dia) .638 .876 C .344 .420 D .093 .093 E (max) .500 .625 F (radius) .035 .035 Three Phase Motor Protectors BJE Type (4-PL) .313 MAX .125 MAX

1.380 MAX

.260/.240 SEALED COVER (2-PL) .223/.213 (4-PL) R .255/.245 2.453/2.437 1.946/1.926 1.578/1.547

www.sensata.com Page 3 Copyright © 2018 Sensata Technologies, Inc. MJE Type SJE Type .188 MAX. .192 MAX .650/.630 .873/.853 .188 MAX .260/.240 .400/.380 SEALED COVER HOLE (2-PL) .162/.142 (4-PL) R .166/.146 .975/.965

1.580 REF

1.635/1.615 1.318/.306 STANDARD CONFIGURATIONS (CONTINUED) .313/.283 .165 MAX.610/.590 .165 MAX (4-PL) .135 MAX SEALED COVER (2-PL) .095/.085 (4-PL) R .166/.146

1.062 REF

1.047 MAX

.814/.810 Three Phase Motor Protectors (Continued)

Rev:10/05/18 www.sensata.com Copyright © 2018 Sensata Technologies, Inc. Sensata Technologies, Inc. (“Sensata”) data sheets are solely intended to assist designers (“Buyers”) who are developing systems that incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, evaluation and judgment in designing Buyer’s systems and products. Sensata data sheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular data sheet. Sensata may make corrections, enhancements, improvements and other changes to its data sheets or components without notice. Buyers are authorized to use Sensata data sheets with the Sensata component(s) identified in each particular data sheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATA SHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATA SHEETS OR USE OF THE DATA SHEETS, EXPRESS, IMPLIED OR STATUTORY , INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY , FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATA SHEETS OR USE THEREOF. All products are sold subject to Sensata’s terms and conditions of sale supplied at www.sensata.com SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA. Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA. Americas +1 (508)-236-3287 klixon@sensata.com AUTHORIZED DISTRIBUTORS Flame Enterprises Bob Correa, Director of Product Management +1 (240) 236-9802 bcorrea@flamecorp.com info@flamecorp.com | Web Tel: 1-800-854-2255 or 1-818- 700-2905 Fax: 1-818-407-5080 Peerless Electronics Steve Gunther, National Sales Manager +1 (516) 594-3509 sgunther@peerlesselectronics. com nysales@peerlesselectronics. com | Web Tel: 1-800-285-2121 Fax: 1-800-222-8096 Europe, Middle East & Africa Flame Enterprises Bob Correa, Director of Product Management +1 (240) 236-9802 bcorrea@flamecorp.com info@flamecorp.com | Web Tel: 1-800-854-2255 or 1-818- 700-2905 Fax: 1-818-407-5080 CONTACT US WARNINGS RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE

  • The product’s side panels may be hot, allow the product to cool before touching
  • Follow proper mounting instructions including torque values
  • Do not allow liquids or foreign objects to enter this product Failure to follow these instructions can result in serious injury, or equipment damage. HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH
  • Disconnect all power before installing or working with this equipment
  • Verify all connections and replace all covers before turning on power Failure to follow these instructions will result in death or serious injury.