Compact fans for AC and DCversion 2011 The engineer’s choice

Trendsetter in fan technology Among the best. Trendsetting with innovative technologies. Listening to customers’ needs. Developing new ideas to meet requirements and realising them with pioneering spirit. This philosophy has made ebm-papst the technological leader in the world of fans. A brand which has very little real competition because every fan is a product of decades of application expertise gained from large-volume production and because we are in a position to produce highly efficient quality products. Our intelligent solutions for electronics cooling ensure that you are one step ahead of competitors thanks to innovative, reliable top-quality technology which is cost-favourable and in line with market requirements. And if required, tailor-made right down to the last detail. In other words, if you need fans which do not yet actually exist, contact us. Insist on ebm-papst. Uncompromising quality made by ebm-papst

– The company 4 – GreenTech: The Green Company 6 – Expertise and technology 8 – Tailor-made 10 – Types of fans 12 – Selecting the correct fan 13 – Fan installation 14 – Service life 15 – Definitions 16 DC axial fans – Axial fans 17 DC centrifugal fans – Centrifugal fans 75 – Tangential fans 105 DC fans - specials – Speed signal 110 – Alarm signal 114 – Vario-Pro ® 119 – Speed setting 120 – Protected fans 123 ACmaxx / i-maxx – Axial fans 125 AC axial fans – Axial fans 141 AC centrifugal fans – Centrifugal fans 163 Accessories – Guard grilles 174 – Filter guard grilles 180 – Inlet nozzles 182 – Connection cables 183 – Accessories 184 ebm-papst representatives & subsidiaries 186 Table of contents InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans

Company profile: ebm-papst Our location in St. Georgen The entire scope of ventilation and drive technology: this is the world of ebm-papst. More than 10,000 people – in Germany and throughout the world – develop, produce and sell our motors and fans. Our global presence and our unique range of products based on a quality standard that surpasses every other have made us what we are: world market leader in motors and fans. Expertly knowing what our customers need and incessantly striving to arrive at the perfect application solution for a wide variety of different industries is what determines our daily work. Those who know us know the high standards we apply to our work and know our creed: to be as close to our customers as possible and to simply be the best in terms of innovation and reliability.

Left: Our headquarters in Mulfingen Right: Our location in Landshut Our history – Our drive Rooted in ebm, PAPST and mvl, the three leading innovators in the development and production of motors and fans, ebm-papst has established itself as the world market leader. Now as ever, our legendary inventive spirit shines through in products that set standards in many segments of industry worldwide. We are proud to say that despite difficult competition, our performance has always been exemplary and outstand- ing – in business, in our personal relationship with our customers, and of course with respect to technology and engineering. For decades, we have contributed to the world of air technology and drive engineering with small revolutions and large milestones. To maintain this advantage in skills and knowledge to get maximum quality and thus the highest degree of customer satisfaction, our employees around the world put their passion and dedication to work for you. Passionately involved in R&D Our catalogues just list the results of our incessant efforts in R&D: products of highest quality and reliability. After all, it is our passion to constantly try something new and improve what we have. In doing so, we take advantage of the latest development methods and state-of- the-art technology and invest quite heavily in R&D facilities. Best of all, though, we rely on excellently trained and skilled engineers and technicians to be at your service in R&D and Sales & Distribution. Producing and safeguarding high-quality products and services This is our promise without any compromise. Whether produced in one of our six factories in Germany or one of our eleven international production sites, our products always have the same high level of quality. This quality control is something you can definitely rely on! And this across all levels of production and throughout all processes: consulting customers, devel- opment, material selection through to picking certified, choice suppliers and on to the production of parts and final delivery. On top of this, our products have to pass the most rigorous tests under all realistic operating conditions: continuous stress test, salt spray test, vibration test, or preci- sion noise measuring, just to mention a few. And the product gets clearance for serial production only after all the desired characteristics have been determined to be just right. Environmental care is another priority with ebm-papst. This is why we have developed our product line in EC technology, which makes for very low power consumption. Due to our manufacturing philosophy, there is absolute focus on environmental care in production, recycling, waste and wastewater disposal. Global Domestic In order to be specialist for customised solutions throughout the world, you need strong partners. Global Domestic – i.e. being present all over the world and being a national company in each individual country – is how we have established ourselves in all important markets on this globe with our successful subsidiaries. And so you will always find ebm-papst close to home, speaking your language, and knowing the demands of your markets. Besides, our worldwide produc- tion alliance serves as a basis for competitive pricing. Our global services and logistic outlets, i.e. IT networking, safeguard short reaction times and just-in-time delivery. All our efforts are documented in a comprehen- sive quality management system, both for prod- ucts and services. Being certified as complying with the tough requirements of the international standards DIN EN ISO 9001, ISO/TS 16949-2 and of standard DIN EN ISO 14001 is just one seal of approval we have received for our unceasing efforts to provide only the best quality products and services. InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans

Sustainability is at the centre of our thoughts and actions. Out of conviction! Eco-friendliness and sustainability have always been at the core of our thoughts and actions. For decades, we have worked according to the simple but strict creed of our co-founder Gerhard Sturm: “Each new product we develop has to be better than the last one in terms of economy and ecology.” GreenTech is the ultimate expression of our corporate philosophy.

GreenTech is acknowledged and certified. Every step in our chain of production meets the stringent standards of environmental specialists and the public. The 2008 Environmental Prize of Baden-Wuerttemberg, the Green Award 2009, the Energy Efficiency Award 2009 of the dena – to give just a few examples – testify to this. The environmental advantage gained in the performance of the products developed from our GreenTech philosophy can also be measured in the fulfilment of the most stringent energy and environmental standards. In many instances, our products are already well below the thresholds energy legislation will impose a few years from now – several times over. Our customers profit from this every day. The heart of GreenTech is future-oriented EC technology from ebm- papst. The EC technology at the core of our most efficient motors and fans allows efficiency of up to 90%, saves energy at a very high level, significantly extends service life and makes our products maintenance- free. These values pay off not only for the environment, but every cent al- so pays off for the user! All ebm-papst products – even those for which GreenTech EC technology does not (yet) make sense from an application viewpoint – feature the greatest possible connection of economy and ecology. GreenTech is pro-active development. Even in the design phase, the materials and processes we use are optimi- sed for the greatest possible eco-friendliness, energy balance and – wherever possible – recyclability. We continually improve the material and performance of our products, as well as the flow and noise charac- teristics. At the same time, we significantly reduce energy consumption. Close co-operation with universities and scientific institutes and the pro- fessorship we endow in the area of power engineering and regenerative energies allows us to profit from the latest research findings in these fields – and at the same time ensure highly qualified young academics. GreenTech is eco-friendly production. GreenTech also stands for maximum energy efficiency in our production processes. There, the intelligent use of industrial waste heat and ground- water cooling, photovoltaics and, of course, our own cooling and venti - lation technology are of the utmost importance. Our most modern plant, for instance, consumes 91% less energy than currently specified and required. In this way, our products contribute to protecting the environ- ment, from their origin to their recyclable packaging. InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans

For the past 60 years, all conceivable types and applications of drive engineering have played an essential role at ebm-papst. A commitment that is the foundation for the development of optimum drive solutions – regardless of the type of fan and its usage. DC fans are generally equipped with electronically commutated external rotor motors; in order to save as much space as possible, commutation electronic com- ponents are integrated in the hub of the fan. Our AC fans are mostly driven by shaded-pole or capacitor motors based on the external rotor principle. In the 3900 and 9900 range of particularly slim fans, internal rotor motors are used. Low-noise performance Our aerodynamically optimised design and high mechanical precision produces outstanding noise properties in series production. So-called “soft” commutation electronics of the DC fans ensure an excellent noise performance. By avoiding steep switching edges when the indi- vidual coils are switched, this reduces the structure-borne noise from the motor. Computer-aided measurements and series of analyses per- formed in a state-of-the-art sound measuring chamber are conducted on each fan model from the very beginning. Long service life The bearing system plays a vital role both in the long life time and quietness of device fans. The SINTEC compact bearing provides most of the device fans with a proven bearing system. Constant low noise during the entire operating time and considerably lower shock sensitivity are the outstanding features of this bearing technology. In addition, with regard to temperature endurance, Sintec compact bearings can be used without problems in most applications. Despite the slightly higher noise and shock sensitivity of ball bearings, this bearing technology should be given pref- erence for fans exposed to extreme thermal and adverse application conditions (e.g. extreme environmental conditions, critical installation position, etc.). The service life data provided in this catalogue is based on exten- sive service life tests and mathematically / scientifically proven service life calculations. Our product descriptions are continuously updated with all relevant data obtained from long-term tests.

Streamline: Aerodynamics With the aid of state-of-the-art computer programs, we are able to optimise the fan impellers and the inner shape of the housing. Air output and available motor performance are exactly matched with the size of fan. This guarantees the low noise that is typical for ebm-papst, even at high back pressure. Sturdy construction – in metal or plastic Fans of all-metal construction: Sturdy and indestructible. The housing is made of an aluminium alloy whereas the metal surfaces that are subject to corrosion are permanently protected by an impact- and abrasion-resistant electrophoretic baked enamel. This particular ver- sion is highly recyclable. Fans with fibreglass-reinforced plastic hous- ing and impeller: Excellent stability and low weight distinguish this highly efficient fan concept. Combinations of metal housing and plastic impeller unite the advantages of both types of design. Product images The dimensioned drawings and product photos that appear in the catalo- gue are for orientation purposes and may differ in some details from the actual product design. Product liability Motors and fans from ebm-papst are components intended for proper installation. The customer bears responsibility for the overall end pro- duct. Safety is included It goes without saying that all ebm-papst fans conform to the approval requirements of the VDE (Association of German Electrical Engineers) and the standards and regulations of UL and CSA. All fans conform to the European Standard EN 60335 or EN 60950 plus those of the UL (Underwriters Laboratories) and CSA (Canadian Standards Association). With few exceptions, our DC fans are designed to meet the requirements of protection class 3 / protection class voltage. ACmaxx fans are protection class 2 / AC fans are protection class 1. ebm-papst fans meet the highest requirements of electrical safety. Depending on the type, they are either impedance protected or equipped with a temperature safety switch, electronic locked-rotor protection, alarm func- tion or have speed monitoring and speed con- trol. Quality in detail It is the seemingly trivial that makes the difference when a product is labelled ‘made by ebm-papst’: consistent maintenance of development and design engineering specifica- tions; target-oriented design; and assured quality across the entire process chain are the reasons why running times of over 150,000 hours are not unusual. The no-compromise ebm-papst quality assurance spans over all process levels – from the choice of materials and the use of carefully selected, certified sup- pliers, from the production of parts up to final assembly. The sum of all these apparently minor details results in fan products with supe- rior lifetimes and reliability. InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans

Tailor-made to meet your special requirements ebm-papst has always developed customer- specific intelligent fans which meet the exact requirements of the application. We provide a wide range of standard fan types, in many sizes and designs; with intelligent motor featu- res, monitoring and control functions as well as special designs for use under extreme con- ditions. They are all based on the standard type fans which you will find in this catalogue. Special fan types for your application can be produced in economical batch sizes. Our expert engineers will assist you in selecting the right configuration. Innovation at its best: Vario-Pro® with “intelligence inside”. Its pro- grammed intelligence thanks to customer-spe- cifically configured software modules makes the cooling of electronics even more economi- cal and flexible. For example, temperature- dependent speed profiles are possible with a number of freely selectable interpolation points. External speed settings and a variety of combinable alarm and tachometer functions can also be programmed. The digital motor management achieves high control accuracy. Practice-oriented: Fans – customised and intelligent

Higher protection class for every type of application ebm-papst provides, on request, many fan series in versions which conform to the requirements of Protection Class IP 54: Their stator and all electrical components are fully encapsulated. Stainless steel ball bearings can be used for operation in particularly aggressive media and use under extreme environmental conditions, thus providing addi- tional reliability. Virtually everything is possible Regardless of your cooling and ventilation tasks, we develop the right solution and what is more, the most economical one. Based on the fans listed in this catalogue, well over 4000 different versions are available. Temperature-controlled fans Fans with temperature-controlled speed have particularly quiet cooling characteristics. Thanks to integrated IC technology, they adapt their speed to the current cooling requirements, which results in a drastic reduction of noise in most operating modes. A temperature sensor pro- vides the fan with thermal information: either externally via a single lead or integrated into the hub of the fan. Speed setting via interfaces With a wide range of DC fans with separate control input, ebm-papst provides an alternative to the NTC-controlled types of fans. They are especially suitable for systems and units which already have standard interfaces for varying speed via internal switching and control circuits. The main applications are units which demand load-dependent individ- ual speed profiles or systems with stand-by minimum cooling require- ments and varied speed increase at varying power peaks. “Electronic tachometer” thanks to sensor signal Do you wish to be informed about the current fan speed at all times? ebm-papst has fans with an integrated “electronic tachometer” which registers the actual value of the fan speed. Via an integrated sensor, the fan gen- erates speed-dependent signals which can be directly utilised. Depending on the number of poles of the motor, 2, 3 or 6 pulses per revo- lution are generated. Alarm signal for more safety If your application requires monitored fan operation, in addition to speed monitoring, ebm-papst also provides a multitude of varying alarm signals. Depending on the type of fan in question, the signal is either static, already evaluated or interface-compatible. The alarm signal output provides reliable longterm monitoring and a status signal if critical operating conditions evolve. S-Force The new measure of things! When you need to provide extremely fast, powerful and efficient cooling for electronic components of all kinds, the generation of S-Force high-performance fans finishes first: in air performance, pressure build-up and technology. Extremely efficient drives and optimised aerodynamics form the core tech- nology of the S-Force fans, which we offer in both an axial and brand-new centrifugal model. InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans

Types of fans and their function Axial fans: High air flow with medium to relatively high pressure build-up The air flow in axial fans, whose impeller is similar to that of a propeller, is conducted to a great extent parallel to the axis of rotation, in other words in the axial direction. Axial fans with free air delivery at zero static pressure have the lowest power input that rises with increasing back pressure. Axial fans for cooling of electronic equipment are mostly equipped with external hous- ing and an electric motor integrated into the fan hub. This compact design allows space-saving accommodation of all devices; the flange is equipped with mounting holes. Diagonal fans: High flow rate at relatively high pressure build-up At first glance diagonal fans only differ slightly from axial fans. Intake is axial, whereas exhaust is diagonal. Due to the conical shape of the wheel and housing, the air is pressurised more. In direct comparison with axial fans of the same size and comparable performance, these fans are distinguished by the lower operating noise at high pressures. Centrifugal fans: High pressure build-up at limited flow rate Many of the cooling problems that occur can be optimally solved by axial and/or diagonal fans. If, for example, the required cooling air has to be conducted at an angle of 90° or if even high pressure is necessary, centrifugal fans are more effective. For your application, ebm-papst offers not only complete centrifugal fans but also motor/impeller combinations without external housing. Tangential fans: High flow rate at low pressure Tangential fans are used above all-, for large-surface air flow in devices. The air flows through the roller-shaped impellers twice in the radial direction: in the intake area from the outside to the inside and in the outflow area from the inside to the outside. Whirls form in the roller due to the vanes which guarantee a steady flow of air through the impeller.

  • Read down from this point to obtain the required value for the cooling air flow. The diagram is based on the following formula: 4. Optimum operating range The required fan, however, must also be able to deliver a suitable static pressure increase Δpf, in order to force the cooling air through the device. A fan must therefore be selected that provides the required air flow performance within its optimum operating range (see also the air performance curves under technical data). 5. Fan selection If the requirements of an application are ful- filled by more than one fan, the noise level, space requirements, economy and ambient conditions will assist in making the final choice. V· [m3/h] ≈ 3· Pv [w] ΔT [K] Selecting the correct fan 1. Dissipated energy A large amount of the energy consumed by electrical and electronic devices is converted into heat. In selecting the correct fan, therefore, it is important to determine the dissipated energy that must be remo- ved. The electrical power consumption of the unit to be cooled, often represents a suitable value for this purpose. 2. Permissible temperature rise The air flow which the selected fan is required to generate, is deter- mined by the dissipated energy and the permissible rise ( ΔT) of the cooling air flow (from entry to exit of the device to be cooled). The max. allowable ΔT depends greatly on the temperature sensitivity of the individual device components. ΔT = 5K means e.g. that the avera- ge air flow leaving the device to be cooled may only be 5°C warmer than the ambient temperature (a large volume of air is required for this purpose). A lower air flow rate is sufficient if a higher temperature dif- ference (e.g. ΔT = 20K), can be tolerated. 3. Required cooling air flow
  • In the below diagram a horizontal line is drawn from the dissipated enery to intersect with the selected ΔT line. 5 10 20 30 40 50 100 200 300 500 Δ t2 0K Δ t1 5K Δ t1 0K Δ t5K m³/hAir Flow 90 m³/h Example : P v = 300 W att Δ t = 10 K Waste Heat Pv Watt 100 150 200 300 500 1000 5000 1 2 3 4 m³/h CFM Optimum Operating Range 0,02 0,04 0,06 0,08 0,10 0,12 [in H2O] Pa InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans

Information on installation When a fan is operated for the first time in an application, the user may have noticed that the flow rate in the device was lower than expected. What is the reason for this?

  • The values stated in this catalogue were determined under optimum, constant and comparable measurement conditions.
  • Ideal mounting conditions under which free air intake and exhaust are present are seldom feasible in practice. Quite frequently the fans must be mounted in close proximity to other components or cabinet panels. As a consequence, the intake and exhaust currents may be restricted, causing the air flow to diminish and the noise level to increase. Fans are particularly sensitive to obstructions which are positioned directly in front of the output cross section as they often cause an increase in tonal noise. Our advice: The distance between the fan and adjacent components should be at least equal to the installation depth of the fan. Intake or exhaust side installation Under ideal conditions, the operating point is represented as the intersection between the fan and loss curves, regardless of whether the fan is positioned at the air intake or exhaust side of the device. In addition to ensuring the required flow rate, several additional aspects must be considered for determining an appro- priate fan concept. The intake air currents of a fan are mainly laminar, comprising nearly the entire suction area. By contrast, the exhaust air of a fan is generally turbulent, while it flows on a pre- ferred direction, e.g. axial for an axial fan. The turbulences of the exhaust intensify the heat transfer from components within the air cur- rents, so that mounting the fan at the air intake side of the device is recommended for cooling and heating. Mounting the fan at the device intake is also advantageous because the fan will not be subjected to the dissipated heat of the device. Therefore, it operates at low ambient temperatures and has a higher life expectancy. Baffle Multidirectional intake, laminar currents Unidirectional exhaust, turbulent Accident prevention The turning rotor and the high speeds that are sometimes involved mean that our fan products carry an inherent risk of injury. They may only be operated after correct installation and with suitable protective facilities (e.g. with a guard grille). More information can be found in the internet at: www.ebmpapst.com/safety

Service life L 10 (40°C) and L10 (T max) The values given in the first two columns have been derived from intensive, in-house service life endurance tests, in which our products are operated in various positions at 40°C and 70°C until they fail. A fan is deemed to have failed when it deviates from its defined air flow and speed values, or when the operating noise becomes noticeable. Such tests can take several years before a representative number of failures have been registered, and even today, some fans are still in the process of endurance testing, even though they began tests in the 1980s. These fans are proof of the legendary reliability of fans from the Black Forest. Test results are presented in a diagram and the service life of the product L 10 at the temperatu- re tested is determined on the basis of the Weibull distribution. These tests have given us years of experience in the way various design parameters and tem- peratures can affect the service life of a product. Data for service life at various temperatures for new products can be stated with a very high degree of precision on the basis of tests, pro- duct specifications and of commonalities in the design of the product. New: Life expectancy L 10Δ (40°C) The new third service life column states the expected service life L 10Δ. This value is based on the calculation methods conventionally applied in the compact fan market. Again here, the foun- dations for the service life values are our service life endurance tests at high ambient tempera- tures. The service life at temperatures below the test temperatures is calculated using fixed fac- tors. This method produces much higher service life values, especially at room tempera ture (see diagram on right). Summary: The life span calculations have been carried out to the best of our knowledge and are based on experience gained by ebm-papst. The specified L10 (40°C), L10 (Tmax) and L 10Δ (40°C) values all allow statements to be made about the theoretical calculated service life under certain assumptions. The values determined here are extrapolations from our own service life tests and from statistical variables. In the respective customer applications, different influences may occur which cannot be included in the calculations due to their complexity. The service life information is explicitly not a guarantee of service life, but strictly a theoretical quality figure. Specials Bel(A) / Watts RPM °C HoursH ours P . 110 5,0 2,5 2 700 -20...+70 67 500 / 35 000 140 000 1 5,3 4,2 3 300 -20...+70 65 000 / 32 500 130 000 2Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service lifeL 10 (40 °C) ebm-papst standard Service lifeL 10 (Tmax) ebm-papst standard Life expectancy L10Δ (40 °C) s. S. 15 Curve Fans in an endurance test cabinet at ebm-papst St. Georgen. 1500 fans are operated in temperature cabinets until they fail. Failure rate (t)/c108 Type of error Premature failure b<1 0 t1 t2 t b>1b1/c187 Wear failure Random failure Service life t Probability of failure (h) b>1 b1/c187 X X = failure X Service life t L10 X X Operating temperature (°C) Expected service life 20 30 40 50 60 70 80 + + +ebm-papst standard 1,5/10K 2/10K 1,65/10K L = 2/15K10Δ Example of the service life figures on the page of the catalogue. Bathtub curve and Weibull distribution. Example of the influence of factors from various manu- facturers on the expected service life. InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans Our fans catalogue gives three different values for the service life of each product. The first column usually states the service life L 10 at 40°C. the second column usually states the service life L 10 at Tmax. Exceptions are marked in the column headings. The third column states the new value , life expectancy L10Δ (40°C). Service life data from ebm-papst St. Georgen

Nominal voltage (Volts) The voltage at which the nominal values (the ta- bular values listed in this catalogue) were deter- mined. The fan operation for DC fans is not lim- ited to the nominal voltage. Fan speed and fan performance can vary according to the permis- sible voltage range that is specified on the nameplate of each fan. Frequency (Hz) ebm-papst AC fans are made for operating fre- quencies of 50 Hz or 60 Hz. Their technical data alter accordingly. Air flow (m3/h) The air performance of the fan in free air opera- tion, i.e. the fan blows into the free space with- out static pressure build-up. Fan curves The fan curves are determined in accordance with DIN 24 163 specifications on a dual-cham- ber test stand with intake-side measurement. This measurement technique closely approxi- mates the operating conditions experienced in typical applications for fans and yields realistic performance curves. The curves apply to an air density of ρ = 1.2 kg/m3, corresponding to an air pressure of 1013 mbar at 20 °C. Variations in air density affect pressure generation but not the flow rate. The pressure generated at other air densities may be estimated with the formula Δρ2= Δρ1( ρ2/ ρ1). The nominal speed values, air flow and power input listed in the table were measured in free air operation with horizontal shaft at an ambient temperature of 20 +5 °C, air density ρ = 1.2 kg/m3 after a warm-up period of 5 min. Optimum operating range During operation, fans are required to produce an air flow with a simultaneous increase of pressure. These operating conditions are described in the section “Optimum Operating Range”. The optimum operating range is there- fore always indicated in this catalogue in the shaded area. In this range the fans operate best with respect to efficiency and noise level. Within this optimum operating range the noise level only fluctuates insignificantly. Noise [dB(A), Bel(A)] 1. Sound pressure level – dB(A) Noise ratings of the fan in free air operation, i.e. at maximum flow rate. 2. Sound power level – Bel(A) / dB(A) Extent of the overall sound radiation of the fan. The sound power level is determined in the optimum operating range. PAPST Sintec® sleeve bearings A particularly efficient bearing system with excellent qualities: – Very precise, large sintered bearings – Low running noise – High service life expectancy – Insensitive to shock and vibration Ball bearings Precision ball bearings for particularly high ambient temperatures and high service life expectancy. Power input (Watts) Input performance of the fan motor when operating at nominal voltage. Depending on the operating condition in the application, the power input may be higher. Temperature range (°C) The permissible ambient temperature range within which the fan can be expected to run continuously. Service life [h] Service life L10 at 40°C and Tmax Standard figures for service life at ebm-papst. These two temperatures are based on intensive, in-house endurance tests and on the experience more than 60 years developing fans. Life expectancy L10Δ Δ (40°C) Figures oriented towards the calculation metho- ds employed by other fan manufacturers. Data based on the internal expected service life at 70°C, more optimistically extrapolated to 40°C. We expressly state that none of the informa- tion or data in this catalogue is to be con- strued as a guarantee or warranty of proper- ties. Unit conversion Air flow Pressure 1cfm = 1,7 m3/h 1Pa = 1x10 -5bar 1l/s = 3,6 m3/h 1 inch H 2O = 249 Pa 1l/min = 0,06 m3/h 1 mm H 2O = 9,81 Pa 1 2 3 4 m³/h Optimum Operating Range 0,02 0,04 0,06 0,08 0,10 0,12 Fan Curve Pa CFM [in H2O] Subject to technical alterations. Our products are not designed for use in the aerospace indu- stry! German and international patents, registered designs and uti- lity models. ebm-papst is a registered trademark of ebm-papst Mulfingen GmbH & Co. KG. PAPST, SINTEC, VARIOFAN and Vario-Pro are registered trade- marks of ebm-papst St. Georgen GmbH & Co. KG.

DC axial fans / DC diagonal fans 23 InformationDC axial fansAccessoriesRepresentatives AC centrifugal fans DC fans - specialsACmaxx / i-maxxAC axial fans DC centrifugal fans

ebm-papst offers you the widest full product line of DC axial and diagonal fans: From 25 mm to 280 mm in size. Every single type of fan can be optimally integrated in the respective device concept. The highly economical brushless motor technology of these fans provides a unique variety of intelligent innovations that can be realised today at prices that would have been unthinkable just a few years ago. Electronic protection against reverse polarity ebm-papst DC fans have electronically commu- tated drives with electronic protection against reverse polarity.The electronics are conveniently located in the fan hub. Product life expectancy A distinctive feature of DC fan technology is the convincingly high product life expectancy. Thanks to the excellent efficiency of the brush- less drives, the thermal load of the bear ings is reduced, thus con siderably increasing the life expectancy of the fans. Protection class DC fans with sleeve and ball bearings are pow- ered by Class E insulated motors. All ebm-papst fans conform to the requirements of protection class IP 20. Fans conforming to IP 54 and spe- cial protection classes are also avail able. Voltage range Many of our DC fans can be operated on volta- ges that are up to 50% lower and 25% higher than their nominal voltage (see Voltage range in the technical tables). This enables the air per- formance to be adapted to the cooling require- ments and allows the noise to be reduced, even if the fan does not have a control input. Closed-loop speed control and monitoring Closed-loop speed control and function monito- ring are becoming increasingly important in many applications. ebm-papst offers many fans in the standard design with a control input and open collector speed signal. S-Force The new S-Force fans with their extremely high blower capacity of up to 950 m 3/h and pressu- re build-up of up to 1200 pascals are capable of dealing with the extreme heat load. If nee- ded, these fans can produce up to 100% more output under full load and they work with a much broader delivery bandwidth than current models. This makes them ideal for equipment and systems with a high density of compo- nents. Thanks to intelligent motor features, they can be individually adapted for any application. S-Force fans are available in 5 standard dimen- sions. Technical information

Axial fans for DC operation Overview of air performance Dimensions Series Air flow Page mm m 3/h /boxopen25 x 8 250 2,1...4,5 23 /boxopen40 x 10 400 F 6...9 24 /boxopen40 x 20 400 10...13,5 25 /boxopen40 x 25 400 J 19...24 26 /boxopen50 x 15 500 F 11...20 27 /boxopen60 x 15 600 F 19...33 28 /boxopen60 x 25 620 21...67 29 /boxopen60 x 25 630 40...44 30 /boxopen60 x 25 600 N 21...56 31 /boxopen60 x 25 600 N VARIOFAN 16...41 32 /boxopen60 x 32 600 J 70...84 33 /boxopen70 x 15 700 F 28...44 34 /boxopen80 x 25 8450 33...118 35 /boxopen80 x 25 8400 N 33...79 36 /boxopen80 x 25 8400 N VARIOFAN 20...58 37 /boxopen80 x 32 8300 32...80 38 /boxopen80 x 38 8200 J 132...222 39 /boxopen92 x 25 3400 N 61...102 40 /boxopen92 x 25 3400 N VARIOFAN 44...84 41 /boxopen92 x 32 3300 56...107 42 /boxopen92 x 38 3200 J 130...280 43 /boxopen119 x 25 4400 F 94...170 44 /boxopen119 x 25 4400 FN 200...225 45 /boxopen119 x 32 4300 95...204 46 /boxopen119 x 32 4300 VARIOFAN 61...170 47 /boxopen119 x 38 4400 150...285 48 /boxopen119 x 38 4100 N 160...237 49 /boxopen119 x 38 DV 4100 275 52 /boxopen127 x 38 5200 N 187...338 53 /boxopen127 x 38 DV 5200 270...324 54 /boxopen135 x 38 5100 N 122...250 55 /boxopen140 x 51 5300 338 56 /boxopen140 x 51 5300 TD 410...670 57 Ø 150 x 38 7100 N 360...420 58 Ø 150 x 55 7200 N 360 59 172x160x52 6100 350 60 Ø 172 x 51 6300 395...545 61 Ø 172 x 51 6300 TD 600...950 62 172x160x51 6300 TD 710...950 63 Ø 172 x 51 DV 6200 540 64 Ø 172 x 51 DV 6200 TD 100...700 65 172x150x51 6400 205...480 66 172x150x51 6400 TD 90...900 67 172x160x51 DV 6400 530 68 172x160x51 DV 6400 TD 100...680 69 220x200x51 2200 FTD 790...1220 70 /boxopen225 x 80 W1G 200 1090 71 /boxopen225 x 80 K1G 200 1020...1245 72 /boxopen225 x 89 K3G 200 1215...1640 73 /boxopen280 x 80 W1G 250 1920 74 m3/h 40 50 60 70 80 9020 30 100 400 500 600 700 800 900200 300 1000 2000 3000 10 40 50 60 70 80 9020 30 100 400 500 600 700 800 900200 300 1000 2000 3000 NEW NEW NEW NEW NEW NEW NEW NEW NEW NEW NEW InformationDC axial fansAccessoriesRepresentatives AC centrifugal fans DC fans - specialsACmaxx / i-maxxAC axial fans DC centrifugal fans

The fan uses a separate wire to output information about its speed, and thus about the speed of the rotor. For technical details, please refer to page 110. On the pages of the catalogue and on the following overview pages, the pictograms illustrated below provide information about t echnically possi- ble special versions in the fan line presented. Please note that these special versions are not possible for all voltages and speeds, and not in all combinations. The special versions are designed for specific customers and projects and are not usually available off the shelf. Go / No-go alarm The fan uses a separate wire to output a static signal when it is stationary, thus providing information about whether or not the rotor is turning. For technical details, please refer to page 117. Alarm with limit speed If the speed drops below a certain level defined in the fan's electronics, the fan will emit a static signal, thus providing information about whether or not the rotor is turning. For technical details, please refer to page 114. External temperature sensor An NTC is connected to the fan via a separate wire and the fan changes its speed depending on the temperatu- re at the NTC. For technical details, please refer to page 120. Internal temperature sensor In this case, the NTC is integrated into the fan and the fan changes its speed depending on the temperature at the NTC. For technical details, please refer to page 120. PWM control input The speed of the fan can be changed via a pulse-width- modulated signal. This signal is applied to a specially provided wire. For technical details, please refer to page 121. Analogue control input The speed of the fan can be changed via a control volta- ge. This control voltage is applied to a specially provided wire. For technical details, please refer to page 121. Protection against moisture Protection for the fan's electronics against moisture and condensation. For technical details, please refer to page 123. IP 54 Protection of motor and PCB board against splashed water and humidity. For technical details, please refer to page 123. Protection against salt spray fog Protection of fan against the damaging effects of salt spray fog. For technical details, please refer to page 123. N G T I PWM A HP IP54IP54/c219 SP Multi-option control input The fan has a control input that the user can trigger eit- her using a PWM signal, an analogue signal or a resistor. For technical details, please refer to page 122.

Axial fans for DC operation Overview of technically feasible designs Axial fans Series mm OPTIONAL P .

4300 VARIOFAN 119 x 119 x 32 yes •• • • •• • – • – – 47

4100 NH7..NH8 119 x 119 x 38 yes •• • • •• • – • – – 51 NEW 5300 S-Force 140 x 140 x 51 yes •• • • •• • – ••• 56

5300 TDS-Force 140 x 140 x 51 yes •• • • •• • • • – – 57

NEW 6300 TDS-Force 172 Ø x 51 yes •• • • •• • • • • • 62 NEW 6300 TDS-Force 172 x 160 x 51 yes •• • • •• • • • • • 63 PageHumidity protectionIP >= IP54Salt spray fog protection Please note that these special versions are not possible for all voltages and speeds, and not in all combinations. The special versions are designed for specific custo- mers and projects. As a rule they are not available off the shelf and are tied to minimum volumes. Please consult your customer support representative about the feasibility of your special variant. Multi-option control input InformationDC axial fansAccessoriesRepresentatives AC centrifugal fans DC fans - specialsACmaxx / i-maxxAC axial fans DC centrifugal fans Sintec sleeve bearings/ball bearings VDE, UL, CSADimensions SensorGo / No-go alarmAlarm with limit speedExternal temperature sensorInternal temperature sensorPWM control input Analogue control input Sleeve bearings Ball bearings – not yet available

  • available * approvals applied for

Special features of S-Force fans The S-Force series is the most powerful product series on the market. S-Force stands for the highest innovation in motor techno logy, fluid mecha- nics and electronics. The one-of-a-kind power density of the products requires special attention to the application at the cus tomer's facility. Service life Due to the high currents in the fans, the load on the electrolyte capaci- tors is greater, which reduces the service life of the capacitor. As a lar- ger or additional capacitor cannot be housed in the fan, the capacitor must be housed in the supply line. If the power pack of the application has a corresponding capacitor, in some cases it may be possible to omit the external capacitor. Recommended capacitors We recommend using the following capacitors from Rubycon:

24 VDC:

50 ZL 680 μF; 12,5 mm x 30 mm or

50 ZLH 680 μF 12,5 mm x 30 mm

48 VDC:

100 YXG 470 μF; 16 mm x 35,5 mm or

100 ZLH 470 μF 16 mm x 31,5 mm

Other capacitors with equal or greater capacitance and equal or lower serial resistance can also be used. ebm-papst St. Georgen offers the following capacitors ex stock:

24 VDC: 1000 μF / 50 V, 16 mm x 25 mm

Art. No.: 992 0345 000 (LZ 354)

48 VDC: 680 μF / 100 V, 18 mm x 40 mm

Art. No. : 992 0355 000 (LZ 355) M Micro- controller Power Supply GND +Vs Recommended measure: Additional external capa- citor (thus must be installed as close to the fan as possible < 30 cm). Fan Capacitor required S-Force axial 8200 / 3200 JH3-JH4 no

4100 NH3 / NH4 / NH5 / NH6 no

4100 NH7 / NH8 yes

2200 FTD no

RER 225 TDM / RG 225 TDM no RER 225 TD / RG 225 TD yes Connection instructions for S-Force fans

max. 4,5 m3/h Highlights: – Compact fan with low power consumption. General characteristics: – Material: fibreglass-reinforced plastic. Impeller PA, housing PBT. – Fully integrated electronic commutation. – Protected against reverse polarity and locking. – Connection via single strands AWG 28, TR 64. Bared and tin-plated. – Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor. – Mass: 5 g. DC axial fans Series 250 25 x 25 x 8 mm 1 2 3 4 m³/h 0 0,4 0,8 1,2 1,6 2,0 2,4 0,150,100,05 Pa CFM [in H2O] Nominal data Specials Type m 3/h CFM VDC VDC dB(A) Bel(A) / Watts RPM °C Hours Hours P . 110 * at 55 °C Nominal voltage Air flow Air flow Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 (20 °C) ebm-papst Standard Service life L10 (60 °C) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 Curve HP InformationDC axial fansAccessoriesRepresentatives AC centrifugal fans DC fans - specialsACmaxx / i-maxxAC axial fans DC centrifugal fans

max. 9 m3/h Nominal data Specials Type m 3/h CFM VDC VDC dB(A) Bel(A) / Watts RPM °C Hours Hours P . 110 Highlights: – Compact fan with low power consumption. – Some models suitable for use at high ambient temperatures. General characteristics: – Material: fibreglass-reinforced plastic. impeller PA, housing PBT. – Fully integrated electronic commutation. – Protected against reverse polarity and locking. – Connection via single strands AWG 28, TR 64. Bared and tin-plated. – Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor. – Mass: 17 g. DC axial fans Series 400 F 40 x 40 x 10 mm 012345 2 4 6 8 0,100,080,060,040,02 m³/h Pa CFM [in H2O] Nominal voltage Air flow Air flow Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 (20 °C) ebm-papst Standard Service life (60 °C) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 Curve Models with temperature range up to +85 °C. HP

Highlights: – Compact fan with low power consumption. – Some models suitable for use at high ambient temperatures. General characteristics: – Material: fibreglass-reinforced plastic. Impeller PA, housing PBT. – Fully integrated electronic commutation. – Protected against reverse polarity and locking. – Connection via single strands AWG 28, TR 64. Bared and tin-plated. – Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor. – Mass: 27 g. DC axial fans Series 400 40 x 40 x 20 mm 01234567 2 4 6 8 10 0,150,100,05 m³/h Pa CFM [in H2O] Nominal data Specials Type m 3/h CFM VDC VDC dB(A) Bel(A) / Watts RPM °C Hours Hours P . 110/118 max. 13,5 m3/h Nominal voltage Air flow Air flow Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 (20 °C) ebm-papst Standard Service life (60 °C) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 Curve Model with temperature range up to +85 °C. HP PWM InformationDC axial fansAccessoriesRepresentatives AC centrifugal fans DC fans - specialsACmaxx / i-maxxAC axial fans DC centrifugal fans

max. 24 m3/h Nominal data Specials Type m 3/h CFM VDC VDC dB(A) Bel(A) / Watts RPM °C Hours Hours P . 110 Highlights: – Very rigid compression curve for high air flow at high back pressure. – Low operating noise level at high back pressure. General characteristics: – Material: fibreglass-reinforced plastic. Impeller PA, housing PBT. – Fully integrated electronic commutation. – Protected against reverse polarity and locking. – Connection via single strands AWG 26, TR 64. Bared and tin-plated. – Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor. – Mass: 50 g. DC axial fans Series 400 J 40 x 40 x 25 mm 02468 1 0 1 2 200 15 20 150 100 0,60,40,2 m³/h Pa CFM [in H2O] Nominal voltage Air flow Air flow Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 Curve IP54IP54/c219 HP

Highlights: – Compact fan with low power consumption. – Some models suitable for use at high ambient temperatures. General characteristics: – Material: fibreglass-reinforced plastic. Impeller PA, housing PBT. – Fully integrated electronic commutation. – Protected against reverse polarity and locking. – Connection via single strands AWG 28, TR 64. Bared and tin-plated. – Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor. – Mass: 25 g. DC axial fans Series 500 F 50 x 50 x 15 mm 02468 1 0 0,100,080,060,040,02 m³/h Pa CFM [in H2O] Nominal data Specials Type m 3/h CFM VDC VDC dB(A) Bel(A) / Watts RPM °C Hours Hours P . 110 max. 20 m3/h Nominal voltage Air flow Air flow Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 (20 °C) ebm-papst Standard Service life L10 (60 °C) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 Curve Model with temperature range up to +85 °C. HP PWM InformationDC axial fansAccessoriesRepresentatives AC centrifugal fans DC fans - specialsACmaxx / i-maxxAC axial fans DC centrifugal fans

max. 33 m3/h Nominal data Specials Type m 3/h CFM VDC VDC dB(A) Bel(A) / Watts RPM °C Hours Hours P . 110/118 Highlights: – Compact fan with low power consumption. – Some models suitable for use at high ambient temperatures. General characteristics: – Material: fibreglass-reinforced plastic. Impeller PA, housing PBT. – Fully integrated electronic commutation. – Protected against reverse polarity and locking. – Connection via single strands AWG 28, TR 64. Bared and tin-plated. – Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor. – Mass: 30 g. DC axial fans Series 600 F 60 x 60 x 15 mm 0369 1 2 1 5 1 8 15 20 0,080,060,040,02 m³/h Pa CFM [in H2O] Nominal voltage Air flow Air flow Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 (20 °C) ebm-papst Standard Service life L10 (60 °C) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 Curve Models with temperature range up to +80 / 85 °C. HP PWM

max. 67 m3/h DC axial fans Series 620 60 x 60 x 25 mm Highlights: – Very rigid compression curve for high air flow at high back pressure. – Motor with very low structure-borne noise. – Innovative impeller with winglets for low noise. – Control inputs, alarm and speed signals available on request. General characteristics: – Material: fibreglass-reinforced plastic. Impeller PA, housing PBT. – Fully integrated electronic commutation. – Protected against reverse polarity and locking. – Connection via single strands AWG 22, TR 64. Bared and tin-plated. – Air exhaust over struts. Direction of rotation clockwise, seen on rotor. – Mass: 85 g. Nominal data Specials Type m 3/h CFM VDC VDC dB(A) Bel(A) / Watts RPM °C Hours Hours P . 110 0 5 10 15 20 25 30 10 20 100 125 0,40,30,20,1 m³/h Pa CFM [in H2O] 01 0 2 0 3 0 0,4 0,60,2 140 105 175 10 20 30 40 50 60 m³/h Pa CFM [in H2O] Nominal voltage Air flow Air flow Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 Curve HP A IP54IP54/c219 PWM I T N G InformationDC axial fansAccessoriesRepresentatives AC centrifugal fans DC fans - specialsACmaxx / i-maxxAC axial fans DC centrifugal fans

0 5 10 15 20 25 [CFM] [Pa] 100 110 0,05 0,1 0,15 0,2 0,25 0,3 0,35 0,4 [in H2O] /h] Highlights: – Very rigid compression curve for high air flow at high back pressure. – Motor with very low structure-borne noise. – Control inputs, alarm and speed signals available on request. – Developed for applications with stringent environmental requirements. General characteristics: – Material: fibreglass-reinforced plastic. Impeller PA, housing PBT. – Fully integrated electronic commutation. – Protected against reverse polarity and locking. – Connection via single strands AWG 22, TR 64. Bared and tin-plated. – Air exhaust over struts. Direction of rotation clockwise, seen on rotor. – Mass: 70 g. DC axial fans Series 630 60 x 60 x 25 mm HP A SP IP54IP54/c219 PWM T N G Nominal data Specials Type m 3/h CFM VDC VDC dB(A) Bel(A) / Watts RPM °C Hours Hours Nominal voltage Air flow Air flow Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 Curve max. 44 m3/h NEW NEW NEW

max. 56 m3/h Highlights: – Ball bearings and sleeve bearings available. – Some models suitable for use at high ambient temperatures up to 85 °C. General characteristics: – Material: fibreglass-reinforced plastic. Impeller PA, housing PBT. – Fully integrated electronic commutation. – Protected against reverse polarity and locking. – Connection via single strands AWG 22, TR 64. Bared and tin-plated. – Air exhaust over struts. Direction of rotation clockwise, seen on rotor. – Mass: 66 g. DC axial fans Series 600 N 60 x 60 x 25 mm 0 5 10 15 20 25 30 10 20 100 30 40 50 0,30,20,1 m³/h Pa CFM [in H2O] Nominal data Specials Type m 3/h CFM VDC VDC dB(A) Bel(A) / Watts RPM °C Hours Hours P . 110-118 IP54IP54/c219 HP I T N G Nominal voltage Air flow Air flow Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 Curve InformationDC axial fansAccessoriesRepresentatives AC centrifugal fans DC fans - specialsACmaxx / i-maxxAC axial fans DC centrifugal fans

max. 41 m3/h Specials Type m 3/h CFM VDC VDC dB(A) Bel(A) / Watts RPM °C Hours Hours 0369 1 2 1 5 1 8 10 20 15 25 30 30°C 55°C

612 NGMI

0,150,100,05 m³/h Pa CFM [in H2O] 0369 1 2 1 5 1 8 10 20 15 25 30 30°C 55°C

612 NMI

0,10 0,150,05 m³/h Pa CFM [in H2O] 0 4 8 12 16 20 10 20 30°C 55°C 0,20 0,250,150,100,05

612 NGNI

612 NNI

612 NGNV

m³/h Pa CFM [in H2O] Highlights: – Open loop speed control by means of external or internal temperature sensor. – Automatic speed adjustment according to cooling requirements. General characteristics: – Material: fibreglass-reinforced plastic. Impeller PA, housing PBT. – Fully integrated electronic commutation. – Protected against reverse polarity and locking. – Connection via single strands AWG 22, TR 64. Bared and tin-plated. – Air exhaust over struts. Direction of rotation clockwise, seen on rotor. – Mass: 66 g. DC axial fans Series 600 N VARIOFAN 60 x 60 x 25 mm 18 10,6 12 8...12,6 14 3,5 1,3 2 150 -20...+65 80 000 / 45 000 160 000 35 20,6 28 4,6 1,7 4 100 2 16 9,4 12 8...12,6 16 3,6 1,0 2 400 -20...+65 80 000 / 45 000 160 000 35 20,6 28 4,6 1,4 4 100 4 23 13,5 12 8...12,6 18 3,8 1,7 2 900 -20...+65 70 000 / 40 000 142 500 41 24,1 35 5,0 2,4 5 100 6 23 13,5 12 8...12,6 18 3,8 1,2 2 900 -20...+65 70 000 / 40 000 142 500 41 24,1 35 5,0 1,5 5 100 6 23 13,5 12 8...12,6 18 3,8 1,7 2 900 -20...+65 70 000 / 40 000 142 500 41 24,1 35 5,0 2,4 5 100 6 30°C 55°C 30°C 55°C 30°C 55°C 30°C 55°C 30°C 55°C I T HP N G Temperature Sensor NTC The temperature sensor for control- ling the motor speed is not included in delivery. Temperature sensor LZ 370 see accessories. Air flow NTC - T emperature Sensor Temperature sensor (NTC-resistor) for controlling the motor speed is positioned directly in the air flow. Nominal data V-Types I-Types Nominal voltage Air flow Air flow Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 Curve

max. 82 m3/h Highlights: – Very rigid compression curve for high air flow at high back pressure. – Innovative impeller with winglets for low noise. General characteristics: – Material: fibreglass-reinforced plastic. Impeller PA, housing PBT. – Fully integrated electronic commutation. – Protected against reverse polarity and locking. – Connection via single strands AWG 24, TR 64. Bared and tin-plated. – Air exhaust over struts. Direction of rotation clockwise, seen on rotor. – Mass: 100 g. DC axial fans Series 600 J 60 x 60 x 32 mm 10 20 30 40 50 60 70 0 10 20 30 40 [CFM] [Pa] 100 150 200 250 300 350 400 450 500 550 0,25 0,5 0,75 1 1,25 1,5 1,75 2 [in H 2O] [m3/h] Nominal data Specials Type m 3/h CFM VDC VDC dB(A) Bel(A) / Watts RPM °C Hours Hours P . 110 Nominal voltage Air flow Air flow Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 Curve HP A PWM T N G NEW NEW Fan types with streamer and integrated guard grille. Rear view of types 614 J/2HHP and 618 J/2HHP InformationDC axial fansAccessoriesRepresentatives AC centrifugal fans DC fans - specialsACmaxx / i-maxxAC axial fans DC centrifugal fans

Highlights: – Very rigid compression curve for high air flow at high back pressure. – Low operating noise level at high back pressure. General characteristics: – Material: fibreglass-reinforced plastic. Impeller PA, housing PBT. – Fully integrated electronic commutation. – Protected against reverse polarity and locking. – Connection via single strands AWG 24 to AWG 28, TR 64. Bared and tin-plated. – Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor. – Mass: 53 g. DC axial fans Series 700 F 70 x 70 x 15 mm Nominal data Specials Type m 3/h CFM VDC VDC dB(A) Bel(A) / Watts RPM °C Hours Hours P . 110 0 4 8 12 16 20 24 10 20 30 40 0,200,150,100,05 m³/h Pa CFM [in H2O] *Version with 3-pole Molex plug housing 22-01-2035 Molex Contacts 08-50-0113 max. 44 m3/h HP N G Nominal voltage Air flow Air flow Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 Curve

max. 117 m3/h Highlights: – Highly stable characteristic curve for high air flow at high back pressure. – Motor with very low structure-borne noise properties. – Innovative impeller with winglets for low noise. – Extremely quiet Sintec sleeve bearing / ball bearing. – Models with PWM control and open collector speed signal. General characteristics: – Material: fibreglass-reinforced plastic. Impeller PA, housing PBT. – Fully integrated electronic commutation. – Protected against reverse polarity and locking. – Connection via single strands AWG 24, TR 64. Bared and tin-plated. – Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor. – Mass: 105 g. DC axial fans Series 8450 80 x 80 x 25 mm 10080604020 0 10 [CFM] [Pa] 100 0,1 [in H 2O] [m3/h] 0,150,05 0,2 0,25 0,3 0,35 0,4 20 30 40 50 60 Nominal data Type m 3/h CFM VDC VDC dB(A) Bel(A) / Watts RPM °C Hours Hours Nominal voltage Air flow Air flow Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 Curve Models with 25 kHz PWM control and speed signal to 4-wire specification (see P . 121). Models with 1-30 kHz PWM control and speed signal. HP A PWM I T N G Specials InformationDC axial fansAccessoriesRepresentatives AC centrifugal fans DC fans - specialsACmaxx / i-maxxAC axial fans DC centrifugal fans

Type m 3/h CFM VDC VDC dB(A) Bel(A) / Watts RPM °C Hours Hours P . 110/112 Highlights: – Ball bearings and sleeve bearings available. – Some models suitable for use at high ambient temperatures up to 85 °C. General characteristics: – Material: fibreglass-reinforced plastic. Impeller PA, housing PBT. – Fully integrated electronic commutation. – Protected against reverse polarity and locking. – Connection via single strands AWG 24, TR 64. Bared and tin-plated. – Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor. – Mass: 95 g. DC axial fans Series 8400 N 80 x 80 x 25 mm 0 8 16 24 32 40 10 20 30 40 50 60 0,10 0,150,05 m³/h Pa CFM [in H2O] max. 79 m3/h A PWM IP54IP54/c219 HP I T N G Nominal voltage Air flow Air flow Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 Curve

Highlights: – Open loop speed control by means of (external or internal) temperature sensor. – Automatic speed adjustment according to cooling requirements. General characteristics: – Material: fibreglass-reinforced plastic. Impeller PA, housing PBT. – Fully integrated electronic commutation. – Protected against reverse polarity and locking. – Connection via single strands AWG 24, TR 64. Bared and tin-plated. – Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor. – Mass: 95 g. DC axial fans Series 8400 N VARIOFAN 80 x 80 x 25 mm Nominal data Specials Type m 3/h CFM VDC VDC dB(A) Bel(A) / Watts RPM °C Hours Hours P . 117

8412 NGLV

20 11,8 12 10...14 < 10 < 3 0,9 900 -20...+70 80 000 / 40 000 160 000 33 19,4 12 3,5 1,1 1 500 2

8412 NGMLV

27 15,9 12 8...14 < 10 3,0 1,1 1 200 -20...+70 80 000 / 40 000 160 000 /3745 26,6 19 3,9 1,5 2 050 4

8412 NGMI

35 20,6 12 8...14 < 13 3,5 1,4 1 600 -20...+70 80 000 / 35 000 125 000 58 34,1 26 4,3 2,0 2 600 6 0 4 8 12 16 20 10 20 2,5 30°C 50°C 7,5 0,030,020,01 m³/h Pa CFM [in H2O] 0 5 10 15 20 25 10 20 30°C 50°C 0,060,040,02 m³/h Pa CFM [in H2O] 0 5 10 15 20 25 30 10 20 30°C 50°C 0,080,060,040,02

8412 NGMV

m³/h Pa CFM [in H2O] 30°C 50°C 30°C 50°C 30°C 50°C max. 58 m3/h HP I T N G Temperature Sensor NTC The temperature sensor for control- ling the motor speed is not included in delivery. Temperature sensor LZ 370 see accessories. Air flow NTC - T emperature Sensor Temperature sensor (NTC-resistor) for controlling the motor speed is positioned directly in the air flow. V-Types I-Types Nominal voltage Air flow Air flow Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 Curve InformationDC axial fansAccessoriesRepresentatives AC centrifugal fans DC fans - specialsACmaxx / i-maxxAC axial fans DC centrifugal fans

Type m 3/h CFM VDC VDC dB(A) Bel(A) / Watts RPM °C Hours Hours P . 110 -116 Highlights: – Optional Vario-Pro: Highly adaptable software configuration of the fan enables a tailor-made solution to the specific requirements of your applications. General characteristics: – Material: fibreglass-reinforced plastic. Impeller PA, housing PBT. – Fully integrated electronic commutation. – Protected against reverse polarity and locking. – Connection via single strands AWG 22, TR 64. Bared and tin-plated. – Air exhaust over struts. Direction of rotation clockwise, seen on rotor. – Mass: 170 g. DC axial fans Series 8300 80 x 80 x 32 mm 0 8 16 24 32 40 10 20 30 40 50 60 100 120 0,40,30,20,1 m³/h Pa CFM [in H2O] Rotor protrusion max. 0,4 mm. max. 80 m3/h HP A SP IP54IP54/c219 PWM I T N G Nominal voltage Air flow Air flow Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 Curve

Series 8200 J 80 x 80 x 38 mm 250 100 200 100 500 600 50 75 300 400 150 100 125 200 1,2 1,6 2,00,80,4 m³/h Pa CFM [in H2O] Nominal voltage Air flow Air flow Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Nominal data Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 Curve Specials Type m 3/h CFM VDC VDC dB(A) Bel(A) / Watts RPM °C Hours Hours P . 110 max. 222 m3/h HP A PWM I T N G Highlights: – Very rigid compression curve for high air flow at high back pressure. – Innovative impeller with winglets for low noise. – Optional Vario-Pro: Highly adaptable software configuration of the fan enables a tailor-made solution to the specific requirements of your applications. General characteristics: – Material: fibreglass-reinforced plastic. Impeller PA, housing PBT. – Fully integrated electronic commutation. Protected against reverse polarity and locking. – Connection via single strands AWG 24 (H3 and H4: AWG 22), TR 64. Bared and tin-plated. – Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor. – Mass: 160 g (H3 and H4: 200 g). 8200 JH3 and JH4 also as standard with PWM control input and speed signal . Speed control range from 2000 RPM up to maximum nominal speed. Stationary at 0 % PWM, maximum speed at sensor break. IP54IP54/c219 InformationDC axial fansAccessoriesRepresentatives AC centrifugal fans DC fans - specialsACmaxx / i-maxxAC axial fans DC centrifugal fans

Type m 3/h CFM VDC VDC dB(A) Bel(A) / Watts RPM °C Hours Hours P . 110/118 Highlights: – Ball bearings and sleeve bearings available. – Some models suitable for use at high ambient temperatures up to 85 °C. General characteristics: – Material: fibreglass-reinforced plastic. Impeller PA, housing PBT. – Fully integrated electronic commutation. – Protected against reverse polarity and locking. – Connection via single strands AWG 24, TR 64. Bared and tin-plated. – Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor. – Mass: 100 g. DC axial fans Series 3400 N 92 x 92 x 25 mm 0 1 02 03 04 05 0 8060 0,10 0,150,05 m³/h Pa CFM [in H2O] Other 48 VDC models on request. max. 102 m3/h A PWM IP54IP54/c219 HP I T N G Nominal voltage Air flow Air flow Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 Curve

max. 84 m3/h Highlights: – Open loop speed control by means of external or internal temperature sensor. – Automatic speed adjustment according to cooling requirements. General characteristics: – Material: fibreglass-reinforced plastic. Impeller PA, housing PBT. – Fully integrated electronic commutation. – Protected against reverse polarity and locking. – Connection via single strands AWG 24, TR 64. Bared and tin-plated. – Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor. – Mass: 100 g. DC axial fans Series 3400 N VARIOFAN 92 x 92 x 25 mm 0 8 16 24 32 40 10 20 30°C 50°C

3412 NGV

0,080,060,040,02 m³/h Pa CFM [in H2O] 0 8 16 24 32 40 10 20 30°C 50°C

3412 NGMV

0,080,060,040,02 m³/h Pa CFM [in H2O] Nominal data Specials Type m 3/h CFM VDC VDC dB(A) Bel(A) / Watts RPM °C Hours Hours P . 117 44 25,9 12 8...14 14 3,5 1,5 1 400 -20...+70 75 000 / 37 500 142 500 72 42,4 28 4,3 2,0 2 300 2 50 29,4 12 8...12,6 16 3,7 1,6 1 600 -20...+70 75 000 / 37 500 142 500 /3784 49,4 32 4,7 2,5 2 700 4 Temperature Sensor NTC The temperature sensor for controlling the motor speed is not included in delivery. Temperature sensor LZ 370 see accessories. 30°C 50°C 30°C 50°C HP I T N G Nominal voltage Air flow Air flow Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 Curve InformationDC axial fansAccessoriesRepresentatives AC centrifugal fans DC fans - specialsACmaxx / i-maxxAC axial fans DC centrifugal fans

Type m 3/h CFM VDC VDC dB(A) Bel(A) / Watts RPM °C Hours Hours P . 110-114 Highlights: – Ball bearings and sleeve bearings available. – Optional Vario-Pro: Highly adaptable software configuration of the fan enables a tailor-made solution to the specific requirements of your applications. General characteristics: – Material: fibreglass-reinforced plastic. Impeller PA, housing PBT. – Fully integrated electronic commutation. – Protected against reverse polarity and locking. – Connection via single strands AWG 22, TR 64. Bared and tin-plated. – Air exhaust over struts. Direction of rotation clockwise, seen on rotor. – Mass: 190 g. DC axial fans Series 3300 92 x 92 x 32 mm max. 107 m3/h HP A SP IP54IP54/c219 PWM I T N G Specials 0 1 02 03 04 05 06 0 20 40 60 80 100 0,150,100,05 0,20 0,25 m³/h Pa CFM [in H2O] Rotor protrusion max. 0,4 mm. Nominal voltage Air flow Air flow Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 Curve

max. 280 m3/h Type m 3/h CFM VDC VDC dB(A) Bel(A) / Watts RPM °C Hours Hours P . 110 Highlights: – Very rigid compression curve for high air flow at high back pressure. – Innovative impeller with winglets for low noise. – Optional Vario-Pro: Highly adaptable software configuration of the fan enables a tailor-made solution to the specific requirements of your applications. General characteristics: – Material: fibreglass-reinforced plastic. Impeller PA, housing PBT. – Fully integrated electronic commutation. Protected against reverse polarity and locking. – Connection via single strands AWG 24 (H3 and H4: AWG 22), TR 64. Bared and tin-plated. – Air exhaust over struts. Direction of rotation clockwise, seen on rotor. – Mass: 240 g (H3 and H4: 280 g). DC axial fans Series 3200 J 92 x 92 x 38 mm 200 100 200 100 40 60 300 150 80 100 0,8 1,20,4 m³/h Pa CFM [in H2O] 0 25 50 75 100 125 50 100 100 150 300 400 500 600 200 200 250 700 150 m³/h Pa CFM [in H2O] Nominal data Specials HP A IP54IP54/c219 PWM I T N G Nominal voltage Air flow Air flow Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 Curve 3200 JH3 and JH4 also as standard with PWM control input and speed signal . Speed control range from 2000 RPM up to maximum nominal speed. Stationary at 0 % PWM, maximum speed at sensor break. InformationDC axial fansAccessoriesRepresentatives AC centrifugal fans DC fans - specialsACmaxx / i-maxxAC axial fans DC centrifugal fans

0,150,100,05 m³/h Pa CFM [in H2O] Available on request: Fan housing with moulded-in spacers. For mounting over both flanges. Highlights: – Ball bearings and sleeve bearings available. – Open loop speed control available on request. – Alarm and speed signals available on request. General characteristics: – Material: fibreglass-reinforced plastic. Impeller PA, housing PBT. – Fully integrated electronic commutation. – Protected against reverse polarity and locking. – Connection via single strands AWG 24, TR 64. Bared and tin-plated. – Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor. – Mass: 175 g. DC axial fans Series 4400 F 119 x 119 x 25 mm Nominal data Specials Type m 3/h CFM VDC VDC dB(A) Bel(A) / Watts RPM °C Hours Hours P . 110-118 max. 170 m3/h HP A PWM I T N G Nominal voltage Air flow Air flow Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 Curve

Type m 3/h CFM VDC VDC dB(A) Bel(A) / Watts RPM °C Hours Hours P . 110/118 Highlights: – Very rigid compression curve for high air flow at high back pressure. – Innovative impeller with winglets for low noise. – Optional Vario-Pro: Highly adaptable software configuration of the fan enables a tailor-made solution to the specific requirements of your applications. General characteristics: – Material: fibreglass-reinforced plastic. Impeller PA, housing PBT. – Fully integrated electronic commutation. – Protected against reverse polarity and locking. – Connection via single strands AWG 22, TR 64. Bared and tin-plated. – Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor. – Mass: 240 g. DC axial fans Series 4400 FN 119 x 119 x 25 mm max. 225 m3/h HP A PWM I T N G 20 40 60 80 100 1200 50 100 150 150 175 125 200 100 m³/h Pa CFM Nominal voltage Air flow Air flow Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 Curve InformationDC axial fansAccessoriesRepresentatives AC centrifugal fans DC fans - specialsACmaxx / i-maxxAC axial fans DC centrifugal fans

max. 204 m3/h Nominal data Specials Type m 3/h CFM VDC VDC dB(A) Bel(A) / Watts RPM °C Hours Hours P . 110-116 Highlights: – Ball bearings and sleeve bearings available. – Optional Vario-Pro: Highly adaptable software configuration of the fan enables a tailor-made solution to the specific requirements of your applications General characteristics: – Material: fibreglass-reinforced plastic. Impeller PA, housing PBT. – Fully integrated electronic commutation. – Protected against reverse polarity and locking. – Connection via single strands AWG 22, TR 64. Bared and tin-plated. – Air exhaust over struts. Direction of rotation clockwise, seen on rotor. – Mass: 220 g. DC axial fans Series 4300 119 x 119 x 32 mm 0 1 53 04 56 07 59 0 25 50 75 100 125 150 0,30,20,1 m³/h Pa CFM [in H2O] Rotor protrusion max. 0,4 mm. HP A IP54IP54/c219 SP PWM I T N G Nominal voltage Air flow Air flow Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 Curve

max. 170 m3/h Nominal data Specials Type m 3/h CFM VDC VDC dB(A) Bel(A) / Watts RPM °C Hours Hours P . 114 Highlights: – Open loop speed control by means of external or internal temperature sensor. – Automatic speed adjustment according to cooling requirements. General characteristics: – Material: fibreglass-reinforced plastic. Impeller PA, housing PBT. – Fully integrated electronic commutation. – Protected against reverse polarity and locking. – Connection via single strands AWG 22, TR 64. Bared and tin-plated. – Air exhaust over struts. Direction of rotation clockwise, seen on rotor. – Mass: 220 g. DC axial fans Series 4300 119 x 119 x 32 mm Rotor protrusion max. 0.4 mm. Temperature Sensor NTC 0 1 02 03 04 05 06 07 0 20 40 60 80 100 4312 MV 25°C 50°C 0,10 0,150,05 m³/h Pa CFM [in H2O] 0 1 53 04 56 07 59 0 25 50 75 100 125 50°C 30°C °C / 4312 T 4314 V 0,200,150,100,05 m³/h Pa CFM [in H2O] 0 1 53 04 56 07 59 0 25 50 75 100 125 50°C25°C 4318 V 0,200,150,100,05 m³/h Pa CFM [in H2O] The temperature sensor for controlling the motor speed is not included in delivery. Temperature sensor LZ 370 see accessories. 4312 MT 65 38,2 12 8...15 25 3,9 1,1 1 100 -20...+65 70 000 / 40 000 142 500 /17138 81,2 39 5,3 3,0 2 300 2 4312 T 85 50,0 12 8...13,2 29 4,2 2,4 1 400 -20...+65 65 000 / 35 000 132 500 /17170 100,1 45 5,8 5,5 2 800 4 4314 T 85 50,0 24 18...32 29 4,2 1,6 1 400 -20...+65 65 000 / 35 000 132 500 /17170 100,1 45 5,8 4,8 2 800 4 4318 V 61 35,9 48 40...53 21 — 2,6 1 000 -20...+65 65 000 / 35 000 132 500 /17170 100,0 45 5,8 5,4 2 800 6 25°C 50°C 25°C 50°C 30°C 50°C 25°C 50°C HP A PWM I T N G Nominal voltage Air flow Air flow Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 Curve InformationDC axial fansAccessoriesRepresentatives AC centrifugal fans DC fans - specialsACmaxx / i-maxxAC axial fans DC centrifugal fans

max. 285 m3/h Nominal data Specials Type m 3/h CFM VDC VDC dB(A) Bel(A) / Watts RPM °C Hours Hours P . 110 Highlights: – Innovative impeller with winglets for low noise. – Control inputs, alarm and speed signals available on request. – High-speed version with 5000 rpm, standard models available with /2 and PWM. General characteristics: – Material: fibreglass-reinforced plastic. Impeller PA, housing PBT. – Fully integrated electronic commutation. – Protected against reverse polarity and locking. – Connection via single strands AWG 24, TR 64. Bared and tin-plated. – Air exhaust over struts. Direction of rotation clockwise, seen on rotor. – Mass: 270 g. DC axial fans Series 4400 119 x 119 x 38 mm 25 50 75 100 1250 50 100 150 100 125 200 0,40,30,20,1 m³/h Pa CFM [in H2O] 20 40 60 80 100 120 1400 50 100 150 100 125 150 175 200 250 m³/h Pa CFM [in H2O] HP A PWM I T N G Nominal voltage Air flow Air flow Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 (40 °C) ebm-papst standard Service life L10 (Tmax) ebm-papst standard Life expectancy L10Δ (40 °C) see P . 15 Curve

max. 237 m3/h Nominal data Type m 3/h CFM VDC VDC dB(A) Bel(A) / Watts RPM °C Hours Hours P . 110-114 Highlights: – Very rigid compression curve for high air flow at high back pressure. – Low operating noise level at high back pressure. – Optional Vario-Pro: Highly adaptable software configuration of the fan enables a tailor-made solution to the specific requirements of your applications. General characteristics: – Material: aluminium housing, fibreglass-reinforced PA impeller; housing with grounding lug for screw M4 x 8 (Torx). – Fully integrated electronic commutation. – Protected against reverse polarity and locking. – Electrical connection with flat plugs, 2.8 x 0.5 mm. Optionally with strands. – Air intake over struts. Direction of rotation clockwise, seen on rotor. – Mass: 390 g. DC axial fans Series 4100 N 119 x 119 x 38 mm 0 20 40 60 80 100 120 40 80 120 160 200 120 100 140 0,50,40,30,20,1 m³/h Pa CFM [in H2O] HP A SP IP54IP54/c219 PWM I T N G Nominal voltage Air flow Air flow Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 Curve Specials InformationDC axial fansAccessoriesRepresentatives AC centrifugal fans DC fans - specialsACmaxx / i-maxxAC axial fans DC centrifugal fans

max. 440 m3/h Highlights: – Very rigid compression curve for high air flow at high back pressure. – Low operating noise level at high back pressure. – Optional Vario-Pro: Highly adaptable software configuration of the fan enables a tailor-made solution to the specific requirements of your applications. General characteristics: – Material: aluminium housing, fibreglass-reinforced PA impeller; housing with grounding lug for screw M4 x 8 (Torx). – Fully integrated electronic commutation. – Protected against reverse polarity and locking. – Connection via single strands AWG 22, UL1007, TR 64, bared and tin-plated – Air intake over struts. Direction of rotation clockwise, seen on rotor. – Mass: 390 g. DC axial fans Series 4100 N High Performance 119 x 119 x 38 mm 0 50 100 150 200 250 100 200 100 200 250 300 350 300 400 150 m³/h Pa CFM [in H2O] 50 100 150 200 2500 100 200 100 300 400 500 600 300 400 200 m³/h Pa CFM [in H2O] Nominal data Specials Type m 3/h CFM VDC VDC dB(A) Bel(A) / Watts RPM °C Hours Hours P . 110 HP A PWM I T N G Nominal voltage Air flow Air flow Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 Curve

max. 570 m3/h HP A SP IP54IP54/c219 PWM I T N G DC axial fans Series 4100 N High Performance 119 x 119 x 38 mm 0 50 100 150 200 250 300 100 200 200 300 400 500 400 600 1000 1200 800 3,22,41,60,8 4,0 m³/h Pa CFM [in H2O] *36...72 VDC on request. Nominal data Type m 3/h CFM VDC VDC dB(A) Bel(A) / Watts RPM °C Hours Hours P . 110 Specials Nominal voltage Air flow Air flow Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 Curve Highlights: – Very rigid compression curve for high air flow at high back pressure. – Low operating noise level at high back pressure. – Available as standard with PWM control input and speed signal, additional inputs and outputs on request. 3-phase fan drive with high degree of running smoothness. General characteristics: – Material: aluminium housing, fibreglass-reinforced PA impeller; housing with grounding lug for screw M4 x 8 (Torx). – Protected against reverse polarity and locking. – Connection via single strands AWG 20, sensor and control leads AWG 22, UL1007, TR 64. Bared and tin-plated. – Air intake over struts. Direction of rotation clockwise, seen on rotor. – Mass: 425 g. Speed control range from 500 RPM up to maximum nominal speed. Stationary at 0 % PWM, maximum speed at sensor break. To attain the specified service life, an external capacitor must be wired between the plus and minus strands. Please note the wiring suggestion on page 22. InformationDC axial fansAccessoriesRepresentatives AC centrifugal fans DC fans - specialsACmaxx / i-maxxAC axial fans DC centrifugal fans

Highlights: – Diagonal compact fan with low noise and high pressure saddle. – Very rigid compression curve for high air flow at high back pressure. – Optional Vario-Pro: Highly adaptable software configuration of the fan enables a tailor-made solution to the specific requirements of your applications. General characteristics: – Material: aluminium housing, fibreglass-reinforced PA impeller; housing with grounding lug for screw M4 x 8 (Torx). – Fully integrated electronic commutation. – Protected against reverse polarity and locking. – Connection via single strands AWG 22, TR 64, bared and tin-plated – Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor. – Mass: 375 g (with aluminium housing : 455 g). DC diagonal fans Series DV 4100 119 x 119 x 38 mm 0 30 60 90 120 150 50 100 150 150 200 250 300 200 100 250 1,00,80,60,40,2 m³/h Pa CFM [in H2O] Nominal data Specials Type m 3/h CFM VDC VDC dB(A) Bel(A) / Watts RPM °C Hours Hours P . 110 max. 275 m3/h HP A SP IP54IP54/c219 PWM I T N G Nominal voltage Air flow Air flow Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 Curve

max. 338 m3/h Nominal data Specials Type m 3/h CFM VDC VDC dB(A) Bel(A) / Watts RPM °C Hours Hours P . 110 Highlights: – Optional Vario-Pro: Highly adaptable software configuration of the fan enables a tailor-made solution to the specific requirements of your applications. General characteristics: – Material: fibreglass-reinforced plastic. Impeller PA, housing PBT. – Fully integrated electronic commutation. – Protected against reverse polarity and locking. – Connection via single strands AWG 22, TR 64. Bared and tin-plated. – Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor. – Mass: 310 g. DC axial fans Series 5200 N 127 x 127 x 38 mm 0 40 80 120 160 200 100 100 150 200 200 300 0,80,60,40,2 m³/h Pa CFM [in H2O] HP A SP IP54IP54/c219 PWM I T N G Nominal voltage Air flow Air flow Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 Curve *Models NHH: Fan housing with moulded-in spacers. InformationDC axial fansAccessoriesRepresentatives AC centrifugal fans DC fans - specialsACmaxx / i-maxxAC axial fans DC centrifugal fans

Type m 3/h CFM VDC VDC dB(A) Bel(A) / Watts RPM °C Hours Hours P . 110 Highlights: – Diagonal fan with lower operating noise at high pressures. – Very rigid compression curve for high air flow at high back pressure. – Optional Vario-Pro: Highly adaptable software configuration of the fan enables a tailor-made solution to the specific requirements of your applications. DV 5214 /2HP with PWM control input and speed signal, additional inputs and outputs on request. General characteristics: – Material: housing of fibreglass-reinforced plastic, optionally of aluminium. Metal flange. Impeller of fibreglass-reinforced plastic PA; housing with grounding lug for screw M4 x 8 (Torx). – Fully integrated electronic commutation. Protected against reverse polarity and locking. – Connection via single strands AWG 22, TR 64, bared and tin-plated. – Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor. – Mass: 415 g (with metal housing: 490 g). DC diagonal fans Series DV 5200 127 x 127 x 38 mm 25 50 75 100 125 150 1750 50 100 150 300 400 200 100 200 250 1,2 1,60,80,4 m³/h Pa CFM [in H2O] Nominal data Specials max. 324 m3/h HP A SP IP54IP54/c219 PWM I T N G Model comes standard with speed signal and PWM control input. Other versions by request. Nominal voltage Air flow Air flow Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 Curve Speed control range from 1000 RPM up to maximum nominal speed. Stationary at 0 % PWM, maximum speed at sensor break.

max. 250 m3/h Nominal data Specials Type m 3/h CFM VDC VDC dB(A) Bel(A) / Watts RPM °C Hours Hours P . 110-112 General characteristics: – Material for aluminium housing and impeller; housing with grounding lug for screw M4 x 8 (Torx). 48 V version incl. screws. – Fully integrated electronic commutation. – Protected against reverse polarity and locking. – Connection via single strands AWG 22, TR 64, bared and tin-plated. – Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor. – Mass: 650 g. DC axial fans Series 5100 N 135 x 135 x 38 mm 0 25 50 75 100 125 100 150 200 0,30,20,1 m³/h Pa CFM [in H2O] HP A SP IP54IP54/c219 PWM I T N G Nominal voltage Air flow Air flow Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 Curve InformationDC axial fansAccessoriesRepresentatives AC centrifugal fans DC fans - specialsACmaxx / i-maxxAC axial fans DC centrifugal fans

0,6 0,8 1,00,40,2 m³/h Pa CFM [in H2O] Highlights: – Very rigid compression curve for high air flow at high back pressure. – Low operating noise level at high back pressure. – Available as standard with PWM control input and speed signal. Additional inputs and outputs on request. General characteristics: – Material: aluminium housing, fibreglass-reinforced PA impeller; housing with grounding lug for screw M4 x 8 (Torx). – Protected against reverse polarity and locking. – Connection via single strands AWG 22, TR 64. Bared and tin-plated. – Air intake over struts. Direction of rotation counter-clockwise, seen on rotor. – Mass: 900 g. DC axial fans Series 5300 140 x 140 x 51 mm HP A IP54IP54/c219 PWM I T N G Speed control range from 700 RPM up to maximum nominal speed. Stationary at 0 % PWM, maximum speed at sensor break. Type m 3/h CFM VDC VDC dB(A) Bel(A) / Watts RPM °C Hours Hours Nominal data Specials Nominal voltage Air flow Air flow Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 Curve max. 338 m3/h NEW NEW

Type m 3/h CFM VDC VDC dB(A) Bel(A) / Watts RPM °C Hours Hours P . 110 Nominal data Specials DC axial fans Series 5300 TD 140 x 140 x 51 mm 500 100 250 100 200 200 600 800 300 400 400 500 600 1000 1200 3,22,41,60,8 4,0 150 200 300 350 400 m³/h Pa CFM [in H2O] max. 670 m3/h HP A PWM I T N G Nominal voltage Air flow Air flow Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 Curve Highlights: – 3-phase fan drive with high degree of running smoothness. – Very rigid compression curve for high air flow at high back pressure. – Low operating noise level at high back pressure. – Standard with PWM control input and speed signal, additional inputs and outputs on request. General characteristics: – Material: aluminium housing, fibreglass-reinforced PA impeller; housing with grounding lug for screw M4 x 8 (Torx). – Protected against reverse polarity and locking. – Connection via single strands AWG 20, TR 64. Bared and tin-plated. – Air intake over struts. Direction of rotation counter-clockwise, seen on rotor. – Mass: 900 g. Speed control range from 1000 RPM up to maximum nominal speed. Stationary at 0 % PWM, maximum speed at sensor break. InformationDC axial fansAccessoriesRepresentatives AC centrifugal fans DC fans - specialsACmaxx / i-maxxAC axial fans DC centrifugal fans

max. 420 m3/h HP A SP IP54IP54/c219 PWM I T N G Type m 3/h CFM VDC VDC dB(A) Bel(A) / Watts RPM °C Hours Hours P . 110 General characteristics: – Material: Aluminium housing and impeller; housing with grounding lug for screw M4 x 8 (Torx). – Fully integrated electronic commutation. – Protected against reverse polarity and locking. – Connection via single strands AWG 22, TR 64, bared and tin-plated. – Air intake over struts. Direction of rotation counter-clockwise, seen on rotor. – Mass: 620 g. DC axial fans Series 7100 N 150 Ø x 38 mm 0 40 80 120 160 200 100 200 100 125 300 150 175 0,60,50,40,30,20,1 m³/h Pa CFM [in H2O] Nominal data Strand fastened using cable tie; cable tie protrudes 1 mm. Nominal voltage Air flow Air flow Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 Curve Specials

Type m 3/h CFM VDC VDC dB(A) Bel(A) / Watts RPM °C Hours Hours P . 110-116 Highlights: – Optional Vario-Pro: Highly adaptable software configuration of the fan enables a tailor-made solution to the specific requirements of your applications. General characteristics: – Material: aluminium housing, fibreglass-reinforced PA impeller; housing with grounding lug for screw M4 x 8 (Torx). – Fully integrated electronic commutation. – Protected against reverse polarity and locking. – Connection via single strands AWG 22, TR 64, bared and tin-plated. – Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor. – Mass: 725 g. DC axial fans Series 7200 N 150 Ø x 55 mm 0 40 80 120 160 200 100 200 100 125 300 0,40,30,20,1 m³/h Pa CFM [in H2O] max. 360 m3/h HP A SP IP54IP54/c219 PWM I T N G Nominal voltage Air flow Air flow Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 Curve InformationDC axial fansAccessoriesRepresentatives AC centrifugal fans DC fans - specialsACmaxx / i-maxxAC axial fans DC centrifugal fans

max. 350 m3/h Highlights: – Compact, lightweight plastic housing. – VARIOFAN models available with external temperature sensor. – Optional Vario-Pro: Highly adaptable software configuration of the fan enables a tailor-made solution to the specific requirements of your applications. – Open loop speed control, sensor and alarm signal available on request. General characteristics: – Material: housing and impeller of fibreglass-reinforced PA. – Fully integrated electronic commutation. – Protected against locking. – Connection via single strands AWG 22, TR 64. Bared and tin-plated. – Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor. – Mass: 610 g. DC axial fans Series 6100 N 172 x 160 x 52 mm HP A SP IP54IP54/c219 PWM I T N G 100 200 100 125 150 300 0 40 80 120 160 200 0,50,40,30,20,1 m³/h Pa CFM [in H2O] Nominal data Specials Type m 3/h CFM VDC VDC dB(A) Bel(A) / Watts RPM °C Hours Hours Nominal voltage Air flow Air flow Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 Curve NEW NEW

Highlights: – Very rigid compression curve for high air flow at high back pressure. – Low operating noise level at high back pressure. – Available as standard with PWM control input and speed signal. Additional inputs and outputs on request. General characteristics: – Material: aluminium housing, fibreglass-reinforced PA impeller; housing with grounding lug for screw M4x8( T orx). – Protected against reverse polarity and locking. – Connection via single strands AWG 22, TR 64. Bared and tin-plated. – Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor. – Mass: 910 g. DC axial fans Series 6300 17 2Øx5 1m m Speed control range from 700 RPM up to maximum nominal speed. Stationary at 0 % PWM, maximum speed at sensor break. Nominal data Specials Type m 3/h CFM VDC VDC dB(A) Bel(A) / Watts RPM °C Hours Hours Nominal voltage Air flow Air flow Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 Curve 100 200 300 400 500 0 [CFM] [Pa] 100 200 300 400 500 [in H2O] [m3/h] 0,50,25 0,75 1,25 1,751 1,5 2 50 100 150 200 250 300 HP A IP54IP54/c219 PWM I T N G SP NEW NEW NEW NEW max. 545 m3/h InformationDC axial fansAccessoriesRepresentatives AC centrifugal fans DC fans - specialsACmaxx / i-maxxAC axial fans DC centrifugal fans

max. 950 m3/h HP A PWM I T N G DC axial fans Series 6300 TD 17 2Øx5 1m m 0 100 200 300 400 500 600 200 400 600 800 1000 2,41,60,8 3,2 200 400 600 800 1000 m³/h Pa CFM [in H2O] Type m 3/h CFM VDC VDC dB(A) Bel(A) / Watts RPM °C Hours Hours P . 110 Nominal data Nominal voltage Air flow Air flow Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 Curve Specials Highlights: – 3-phase fan drive high degree of running smoothness. – Very rigid compression curve for high air flow at high back pressure. – Low operating noise level at high back pressure. – Standard with PWM control input and speed signal, additional inputs and outputs on request. General characteristics: – Material: aluminium housing, fibreglass-reinforced PA impeller; housing with grounding lug for screw M4x8( T orx). – Protected against reverse polarity and locking. – Connection via single strands AWG 20, TR 64. Bared and tin-plated. – Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor. – Mass: 910 g. Speed control range from 1000 RPM up to maximum nominal speed. Stationary at 0 % PWM, maximum speed at sensor break. SP IP54IP54/c219

max. 950 m3/h HP A PWM I T N G DC axial fans Series 6300 TD 172 x 160 x 51 mm 0 100 200 300 400 500 600 200 400 600 800 1000 2,41,60,8 3,2 200 400 600 800 1000 m³/h Pa CFM [in H2O] Type m 3/h CFM VDC VDC dB(A) Bel(A) / Watts RPM °C Hours Hours Nominal data Nominal voltage Air flow Air flow Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) Curve Highlights: – 3-phase fan drive with high degree of running smoothness. – Very rigid compression curve for high air flow at high back pressure. – Low operating noise level at high back pressure. – Standard with PWM control input and speed signal, additional inputs and outputs on request. General characteristics: – Material: aluminium housing, fibreglass-reinforced PA impeller; housing with grounding lug for screw M4x8( T orx). – Protected against reverse polarity and locking. – Connection via single strands AWG 20, TR 64. Bared and tin-plated. – Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor. – Mass: 910 g. Speed control range from 1000 RPM up to maximum nominal speed. Stationary at 0 % PWM, maximum speed at sensor break. *Vorläufig SP IP54IP54/c219 NEW NEW Specials InformationDC axial fansAccessoriesRepresentatives AC centrifugal fans DC fans - specialsACmaxx / i-maxxAC axial fans DC centrifugal fans

max. 540 m3/h Type m 3/h CFM VDC VDC dB(A) Bel(A) / Watts RPM °C Hours Hours P . 110/112 Highlights: – Diagonal compact fan with low noise and high pressure saddle. – Very rigid compression curve for high air flow at high back pressure. General characteristics: – Material: aluminium housing, fibreglass-reinforced PA impeller; housing with grounding lug for screw M4x8( T orx). 48 V version incl. screws. – Fully integrated electronic commutation. – Protected against reverse polarity and locking. – Connection via single strands AWG 22, TR 64. Bared and tin-plated. – Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor. – Mass: 820 g. DC diagonal fans Series DV 6200 17 2Øx5 1m m 50 100 150 200 250 3000 200 400 100 150 200 250 300 350 300 500 600100 1,21,00,80,60,40,2 m³/h Pa CFM [in H2O] Nominal data Specials HP A SP IP54IP54/c219 PWM I T N G Nominal voltage Air flow Air flow Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 Curve

max. 700 m3/h Nominal data Type m 3/h CFM VDC VDC dB(A) Bel(A) / Watts RPM °C Hours Hours P . DV 6224 TD... 100 58,9 24 16...36 29 — 2,0 800 -20...+60 65 000 130 000 700 421,0 69 7,8 89,0 5 500 2 DV 6248 TD... 100 58,9 48 40...55* 29 — 2,0 800 -20...+60 65 000 / 40 000 130 000 700 421,0 69 7,8 89,0 5 500 2 Highlights: – Diagonal compact fan with low noise and high pressure saddle. – 3-phase fan drive with high degree of running smoothness. – Very rigid compression curve for high air flow at high back pressure. – Control inputs, alarm and speed signals available on request. General characteristics: – Material: aluminium housing, fibreglass-reinforced PA impeller; housing with grounding lug for screw M4x8( T orx). 48 V version incl. screws. – Fully integrated electronic commutation. – Connection via single strands AWG 22, TR 64. Bared and tin-plated. – Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor. – Mass: 820 g. DC diagonal fans Series DV 6200 TD TURBOFAN 17 2Øx5 1m m 1000 200 300 400 200100 300 100 300 400 500 600 400 500 200 600 nmin nmax1 1,2 1,6 2,00,80,4 m³/h Pa CFM [in H2O] min max min max HP A SP IP54IP54/c219 PWM I T N G The data specified here are technically feasible benchmark values. The fans can be specially adapted to your application with signal outputs and control inputs. For details of the technical possibilities, refer to the chapters on the sensor signal, alarm signal and control inputs beginning on page 107. *Fan with extended voltage range available on request. Nominal voltage Air flow Air flow Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 Curve Specials P . 110-116 and120, 121,123 P . 110-116 and120, 121,123 InformationDC axial fansAccessoriesRepresentatives AC centrifugal fans DC fans - specialsACmaxx / i-maxxAC axial fans DC centrifugal fans

max. 480 m3/h Type m 3/h CFM VDC VDC dB(A) Bel(A) / Watts RPM °C Hours Hours P . 110/112 Highlights: – Optional Vario-Pro: Highly adaptable software configuration of the fan enables a tailor-made solution to the specific requirements of your applications. General characteristics: – Material: aluminium housing, fibreglass-reinforced PA impeller; housing with grounding lug for screw M4x8( T orx). 48 V version incl. screws. – Fully integrated electronic commutation. – Protected against reverse polarity and locking. – Electrical connection with flat plugs 3 x 0.5 mm. – Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor. – Mass: 760 g. DC axial fans Series 6400 172 x 150 x 51 mm 0 50 100 150 200 250 100 200 100 125 150 175 300 400 m³/h Pa CFM [in H2O] Nominal data Specials * Leads 310 mm. ** 72 °C upon request. HP A SP IP54IP54/c219 PWM I T N G Nominal voltage Air flow Air flow Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 Curve

Series 6400 TD TURBOFAN 172 x 150 x 51 mm Highlights: – 3-phase fan drive with high degree of running smoothness. – Very rigid compression curve for high air flow at high back pressure. – Control inputs, alarm and speed signals available on request. – Optionally available with reversible speed. General characteristics: – Material: aluminium housing, fibreglass-reinforced PA impeller; housing with grounding lug for screw M4x8( T o r x ) .4 8Vversion incl. s crews. – Fully integrated electronic commutation. – Connection via single strands AWG 22, TR 64. Bared and tin-plated. – Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor. Direction of rotation reversible. – Mass: 760 g. Nominal data Specials Type m 3/h CFM VDC VDC dB(A) Bel(A) / Watts RPM °C Hours Hours P . 6424 TD... 90 53,0 24 16...28 18 — 2,0 800 -20...+60 70 000 / 45 000 110 000 600 353,1 65 7,4 50,0 5 100 2 6448 TD... 90 53,0 48 40...55* 18 — 2,0 800 -20...+60 70 000 / 45 000 110 000 600 353,1 65 7,4 50,0 5 100 2 6448 TDHH... 90 53,0 48 36...72 18 — 2,0 800 -20...+60 70 000 / 45 000 110 000 900 529,7 78 8,6 163,0 7500 3 min max min max min max 100 200 3000 400 500 300 600 400 500 200 300 100 600 700 800 450 750 900150 nmin nmax m³/h Pa CFM [in H2O] max. 900 m3/h HP A SP IP54IP54/c219 PWM I T N G The data specified here are technically feasible benchmark values. The fans can be specially adapted to your application with signal outputs and control inputs. For details of the technical possibilities, refer to the chapters on the sensor signal, alarm signal and control inputs beginning on page 108. *Fan with extended voltage range available on request. Nominal voltage Air flow Air flow Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 Curve P . 110-116 and120, 121,123 P . 110-116 and120, 121,123 InformationDC axial fansAccessoriesRepresentatives AC centrifugal fans DC fans - specialsACmaxx / i-maxxAC axial fans DC centrifugal fans

max. 530 m3/h Nominal data Specials Type m 3/h CFM VDC VDC dB(A) Bel(A) / Watts RPM °C Hours Hours P . 112 Highlights: – Diagonal compact fan with low noise and high pressure saddle. – Very rigid compression curve for high air flow at high back pressure. – Optional Vario-Pro: Highly adaptable software configuration of the fan enables a tailor-made solution to the specific requirements of your applications. General characteristics: – Material: aluminium housing, fibreglass-reinforced PA impeller; housing with grounding lug for screw M4x8( T orx). 48 V version incl. screws. – Fully integrated electronic commutation. – Protected against reverse polarity and locking. – Connection via single strands AWG 22, TR 64. Bared and tin-plated. – Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor. – Mass: 820 g. DC diagonal fans Series DV 6400 172 x 160 x 51 mm 0 60 120 180 240 300 100 200 300 150 200 250 300 350 400 100 500 1,21,00,80,60,40,2 m³/h Pa CFM [in H2O] HP A SP IP54IP54/c219 PWM I T N G Nominal voltage Air flow Air flow Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 Curve

max. 680 m3/h DV 6424 TD... 100 58,9 24 16...28 29 — 2,0 800 -20...+60 65 000 / 40 000 130 000 680 400,2 71 7,9 91,0 5 500 2 DV 6448 TD... 100 58,9 48 40...55 29 — 2,0 800 -20...+60 65 000 / 40 000 130 000 680 400,2 71 7,9 86,0 5 500 2 Highlights: – Diagonal compact fan with low noise and high pressure saddle. – 3-phase fan drive with high degree of running smoothness. – Very rigid compression curve for high air flow at high back pressure. – Control inputs, plus alarm and speed signals available on request. – Optionally available with reversible speed. General characteristics: – Material: aluminium housing, fibreglass-reinforced PA impeller; housing with grounding lug for screw M4x8( T orx). 48 V version incl. screws. – Fully integrated electronic commutation. – Connection via single strands AWG 22, TR 64. Bared and tin-plated. – Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor. Direction of rotation reversible. – Mass: 820 g. DC diagonal fans Series DV 6400 TD TURBOFAN 172 x 160 x 51 mm 1000 200 300 200100 300 100 300 400 500 600 400 500 200 600 nmin nmax 1,2 1,6 2,00,80,4 m³/h Pa CFM [in H2O] min max min max Nominal data Specials Type m 3/h CFM VDC VDC dB(A) Bel(A) / Watts RPM °C Hours Hours P . HP A SP IP54IP54/c219 PWM I T N G The data specified here are technically feasible benchmark values. The fans can be specially adapted to your application with signal outputs and control inputs. For details of the technical possibilities, refer to the chapters on the sensor signal, alarm signal and control inputs beginning on page 108. Nominal voltage Air flow Air flow Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 Curve P . 110-116 and120, 121,123 P . 110-116 and120, 121,123 InformationDC axial fansAccessoriesRepresentatives AC centrifugal fans DC fans - specialsACmaxx / i-maxxAC axial fans DC centrifugal fans

max. 1220 m3/h HP A SP IP54IP54/c219 PWM I T N G DC axial fans Series 2200 FTD 220 x 200 x 51 mm 1000 200 300 400 400200 600 200 600 800 800 1000 m³/h Pa 400 CFM 500 600 Type m 3/h CFM VDC VDC dB(A) Bel(A) / Watts RPM °C Hours Hours P . 110 Nominal data Nominal voltage Air flow Air flow Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) Curve Specials Highlights: – High- performance 200 mm fan with compact overall height. – Low operating noise level at high back pressure. – 3-phase fan drive high degree of running smoothness and high efficiency. – Standard with speed signal and PWM (P) or 0-10VDC / PWM (O) speed control. General characteristics: – Material: aluminium housing, fibreglass-reinforced PA impeller; housing with grounding lug for screw M4 x 8. – Electronic commutation fully integrated. – Protected against reverse polarity and locking. – Connection via single strands AWG 20, UL 1007 / AWG 22, UL 1061, bared and tin-plated. – Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor. – Mass: 1000 g. Speed control range from 1000 RPM up to maximum nominal speed. Stationary at 0 % PWM / 0 V, Type O: stationary at sensor break; Type P: maximum speed at sensor break.

Type m 3/h CFM VDC VDC dB(A) Bel(A) / Watts RPM °C Hours – Material: Die-cast aluminium wall ring, 9 sheet steel blades. Blades and rotor coated in black. – Protected against reverse polarity and locking. – Direction or air flow: “V”, exhaust over struts. Direction of rotation counter-clockwise, seen on rotor. – Type of protection: IP 42. Insulation class: “B”. – Maintenance-free ball bearings. – Control input 0-10 V DC / PWM and tach output. – Electrical connection with terminal strip. – Continuous operation (S1). – Mass: 2.1 kg. DC axial fans W1G 200 225 x 225 x 80 mm U R U N 200 400 600 800 1000 0 200 400 600 120 160 200 240 5 1 0,80,60,40,2 m³/h Pa CFM [in H2O] Nominal data nP 1 LpA [RPM] [W] [dB(A)] ➀ ❶’ 2300 73 63 ➀ ➋’ 2970 77 62 ➀ ➌’ 3100 80 63 ➀ ➍’ 2970 80 66 ➀ ❶ 2950 55 60 ➀ ➋ 2890 58 60 ➀ ➌ 2800 61 61 ➀ ➍ 2780 63 64 ➀ ➎ 2270 27 55 ➀ ➏ 2230 28 54 ➀ ➐ 2170 29 54 ➀ ➑ 2130 30 57 max. 1090 m3/h Nominal voltage Air flow Air flow Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Curve InformationDC axial fansAccessoriesRepresentatives AC centrifugal fans DC fans - specialsACmaxx / i-maxxAC axial fans DC centrifugal fans

max. 1245 m3/h DC diagonal module K1G 200 225 x 225 x 80 mm – Material: Housing made of fibreglass-reinforced PA6 plastic, seven blades made of fibre- glass-reinforced PA6 plastic. Rotor coated in black – Protected against reverse polarity and locking. – Direction of air flow “V”. Direction of rotation CW, seen on rotor. – Maintenance-free ball bearings. – Control input 0-10 VDC / PWM and tach output. – Electrical connection via connection line AWG 20, 4x brass lead tips crimped. – Continuous operation (S1). – Mass: 1.7 kg. +- 0,5 276 288 200 400 600 800 1000 0 400 [CFM]200100 300 500 600 [Pa] 100 200 300 400 500 [m3/h] 111 1 Type m 3/h CFM VDC VDC A dB(A) / Watts RPM °C Hours Nominal data Nominal voltage Air flow Air flow Voltage range Current draw Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Curve nP 1 IL w A [RPM] [W] [A] [dB(A)] ➀ ❶ 3400 95 4,70 76 ➀ ➋ 3410 116 5,61 74 ➀ ➌ 3410 119 5,75 74 ➀ ➍ 3410 117 5,62 76 ➁ ❶ 3520 107 5,30 77 ➁ ➋ 3520 127 6,24 75 ➁ ➌ 3520 129 6,31 76 ➁ ➍ 3520 126 6,18 76 ➂ ❶ 3650 120 3,40 77 ➂ ➋ 3650 141 3,90 75 ➂ ➌ 3650 145 3,99 76 ➂ ➍ 3650 141 3,88 78 ➃ ❶ 4140 183 5,60 81 ➃ ➋ 4090 212 6,46 79 ➃ ➌ 4060 213 6,52 79 ➃ ➍ 4110 211 6,43 80 NEW NEW NEW NEW Cable assignment: Red = UN Yellow = 0-10 VDC White = Speed monitoring output Blue = GND Air performance measured as per: ISO 5801, Installation category A, without protection against accidental contact Suction-side noise levels: LwA as per ISO 13347 The acoustic values given are only valid under the measur- ment conditions listed and may vary depending on the installation situation. With any deviation to the stan- dard setup, the specific values have to be checked and re- viewed once installed or fitted!

InformationDC axial fansAccessoriesRepresentatives AC centrifugal fans DC diagonal module K3G 200 225 x 225 x 89 mm max. 1640 m3/h – Material: Housing made of fibreglass-reinforced PA6 plastic, seven blades made of fibre- glass-reinforced PA6 plastic. Rotor coated in black – Protected against reverse polarity and locking. – Direction of air flow “V”. Direction of rotation CW, seen on rotor. – Maintenance-free ball bearings. – Control input 0-10 VDC / PWM and tach output. – Electrical connection via connection line AWG 16, 4x crimped core-end sleeves. – Continuous operation (S1). – Mass: 2.2 kg. +- 0,5 276 288 400 800 1200 1600 0 400 [CFM]200 600 800 [Pa] 100 200 300 400 500 600 700 800 0,4 [m3/h] 111 Cable assignment: Red = UN Yellow = 0-10 VDC White = Speed monitoring output Blue = GND Type m 3/h CFM VDC VDC A dB(A) / Watts RPM °C Hours Nominal data Nominal voltage Air flow Air flow Voltage range Current draw Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Curve NEW NEW NEW NEW DC fans - specialsACmaxx / i-maxxAC axial fans DC centrifugal fans nP 1 IL w A [RPM] [W] [A] [dB(A)] ➀ ❶ 4060 185 7,70 81 ➀ ➋ 4010 204 8,48 78 ➀ ➌ 4010 209 8,70 78 ➀ ➍ 4020 208 8,66 79 ➁ ❶ 5140 339 7,10 86 ➁ ➋ 5070 373 7,78 83 ➁ ➌ 5060 385 8,01 83 ➁ ➍ 5080 380 7,91 84 ➂ ❶ 5480 418 8,70 87 ➂ ➋ 5250 421 8,77 84 ➂ ➌ 5190 422 8,78 83 ➂ ➍ 5240 421 8,77 85 Air performance measured as per: ISO 5801, Installation category A, without protection against accidental contact Suction-side noise levels: LwA as per ISO 13347 The acoustic values given are only valid under the measur- ment conditions listed and may vary depending on the installation situation. With any deviation to the stan- dard setup, the specific values have to be checked and re- viewed once installed or fitted!

Type m 3/h CFM VDC VDC dB(A) Bel(A) / Watts RPM °C Hours – Material: Die-cast aluminium wall ring, 7 sheet steel blades. Blades and rotor coated in black. – Protected against reverse polarity and locking. – Direction or air flow: “V”, exhaust over struts. Direction of rotation counter-clockwise, seen on rotor. – Type of protection: IP 42. Insulation class: “B”. – Maintenance-free ball bearings. – Control input 0-10 V DC / PWM and tach output. – Electrical connection with terminal strip. – Continuous operation (S1). – Mass: 2.4 kg. DC axial fans W1G 250 280 x 280 x 80 mm U R U N 400 800 1200 1600 4000 800 120 160 200 5 1 [CFM] m³/h 0,80,60,40,2 Pa [in H2O] nP 1 LpA [RPM] [W] [dB(A)] ➀ ❶’ 2920 129 71 ➀ ➋’ 2800 132 72 ➀ ➌’ 2680 135 71 ➀ ➍’ 2600 139 72 ➀ ❶ 2750 105 70 ➀ ➋ 2630 110 69 ➀ ➌ 2520 111 69 ➀ ➍ 2440 114 70 ➀ ➎ 2610 73 66 ➀ ➏ 2320 75 67 ➀ ➐ 2230 78 67 ➀ ➑ 2170 80 68 Nominal data max. 1920 m3/h Nominal voltage Air flow Air flow Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Curve

DC centrifugal fan overview 77 DC centrifugal fans 79 DC tangential fans 105 InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans

Our centrifugal product line includes fans for every application. Whether as free-running impellers with a diameter between 97 mm and 225 mm or as assemblies in a ready-to-install, compact housing with inlet nozzle with an edge length between 51 mm and 270 mm. Of cour- se, all models feature high-efficiency, brushless motor technology. Electronic protection against reverse polarity ebm-papst DC fans have electronically commu- tated drives with electronic protection against reverse polarity.The electronics are conveniently located in the fan hub. Product life expectancy A distinctive feature of DC fan technology is the convincingly high product life expectancy. Thanks to the excellent efficiency of the brush- less drives, the thermal load of the bearings is reduced, thus considerably increasing the life expectancy of the fans. Protection class DC fans with sleeve and ball bearings are pow- ered by Class E insulated motors. All ebm-papst fans conform to the requirements of Protection Class IP 20. Fans conforming to IP 54 and spe- cial protection classes are also available. Voltage range Many of our DC fans can be operated on volta- ges that are up to 50% lower and 25% higher than their nominal voltage (see Voltage range in the technical tables). This enables the air per- formance to be adapted to the cooling require- ments and allows the noise to be reduced, even if the fan does not have a control input. Closed-loop speed control and monitoring Closed-loop speed control and function monito- ring are becoming increasingly important in many applications. ebm-papst offers many fans in the standard design with a control input and open collector speed signal. S-Force centrifugal – RadiCal The new S-Force centrifugal fans provide peak performance among fans of this type. With air flow capacity at over 1500 m³/h and a pressure build-up of up to 1000 pascals, the highest heat flows are manageable. In addition, the models are extremely efficient due to the multi-pole, electronically commutated drive motors and can be adapted individually to every application thanks to intelligent motor features. Some models use our new, highly efficient RadiCal impellers. Technical information

Centrifugal fans for DC operation Overview of air performance Dimensions Series Air flow Page mm m 3/h 105 x 59 x 79 RV 40 18...24 79 /boxopen51 x 15 RLF 35 9,6 80 /boxopen76 x 27 RL 48 22...28 81 97 x 93,5 x 33 RL 65 56...61 82 /boxopen121 x 37 RL 90 N 40...55 83 /boxopen127 x 25 RLF 100 64...80 84 /boxopen1 3 5x3 8 R G9 0N 5 5 85 /boxopen180 x 40 RG 125 N 60...137 86 /boxopen220 x 56 RG 160 N 139...209 87 /boxopen220 x 56 RG 160 NTD 59...370 88 /boxopen225 x 85 RG 190 TD 630...930 89 /boxopen270 x 99 RG 220 TD 1090...1280 90 /boxopen270 x 119 RG 225 TD 1040...1210 91 Ø 97 x 41 RET 97 TD 220 92 Ø 104 x 25 REF 100 86...104 93 Ø 101 x 52 RER 101 190 94 Ø 120 x 54 RER 120 TD 320...390 95 Ø 138 x 35 RER 125 N 74...166 96 Ø 133 x 91 RER 133 TD 460...565 97 Ø 165 x 51 RER 160 N 255 98 Ø 165 x 51 RER 160 NTD 66...354 99 Ø 175 x 55 REF 175 TD 800 100 Ø 175 x 69 RER 175 TD 600...980 101 Ø 190 x 69 RER 190 TD 650...970 102 Ø 220 x 71 RER 220 TD1090...1280 103 Ø 225 x 99 RER 225 TD1080...1600 104 10 40 50 60 70 80 9020 30 100 400 500 600 700 800 900200 300 1000 2000 3000 m3/h 10 40 50 60 70 80 9020 30 100 400 500 600 700 800 900200 300 1000 2000 3000 NEW NEW NEW NEW NEW NEW NEW NEW NEW NEW NEW NEW NEW InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans

Centrifugal fans for DC operation Overview of technically feasible designs Centrifugal fans Series mm OPTIONAL P . NEW RG 160 NTD 220 x 220 x 56 yes •• • • • • • – ••• 88 NEW RG 190 TD 225 x 225 x 85 yes •• • • • • • •• • • 89 NEW RG 220 TD 270 x 270 x 99 yes •• • • • • • •• • –9 0 NEW RG 225 TD 270 x 270 x 132 yes •• • • • • • •• • –9 1 PageIP >= IP54 Please note that these special versions are not possible for all voltages and speeds, and not in all combinations. The special versions are designed for specific custo- mers and projects. As a rule they are not available off the shelf and are tied to minimum volumes. Please consult your customer support representative about the feasibility of your special variant. Multi-option control input Optional special versions / Information pictograms (see page 20) On the catalogue pages and in the overview on page 20, the pictograms shown provide information about the special designs that are technically feasible in the fan series. Please note that these special versions are not possi- ble for all voltages and speeds, and not in all combinations. The special versions are designed for specific customers and projects and are not usually available off the shelf. Sleeve Bearings Ball Bearings – not yet available

  • available * approvals applied for Humidity protectionSalt spray fog protectionSintec sleeve bearings/ball bearingsVDE, UL, CSADimensions SensorGo / No-go alarmAlarm with limit speedExternal temperature sensorInternal temperature sensorPWM control inputAnalogue control input

Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 max. 24 m3/h Nominal data Type m 3/h CFM VDC VDC Bel(A) / Watts RPM °C Hours Hours Highlights: – Pressure-optimised blower. – Motor with very low structure-borne noise properties. – Forward curved impeller. General characteristics: – Fibreglass-reinforced plastic scroll housing and impeller. – Fully integrated electronic commutation. – Protected against reverse polarity and locking. – Direction of air flow: axial air intake, centrifugal air exhaust out of the outlet. – Connection via single strands AWG 26, TR 64. Bared and tin-plated. – Mass: 100 g. DC centrifugal fans Series RV 40 105 x 59 x 79 mm Intake opening Ø 30 Ø 31 Ø 46,5 Ø 40 10,5 2,3 2,51 44,9 32,4 18,35 36,35 12 60,4 45,78 4,2 (2x) 42,04 58,85 0369 1 2 1 5 51 0 100 125 0,40,30,20,1 m³/h Pa CFM [in H2O] N G HP PWM Specials InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans

Type m 3/h CFM VDC VDC Bel(A) / Watts RPM °C Hours Hours Highlights: – Noise-optimised air outlet in scroll housing. – Very flat and powerful centrifugal fan. – Forward curved impeller. General characteristics: – Fibreglass-reinforced plastic scroll housing and impeller. – Fully integrated electronic commutation. – Protected against reverse polarity and locking. – Direction of air flow: axial air intake, centrifugal air exhaust out of the outlet. – Connection via single strands AWG 26, TR 64. Bared and tin-plated. – Mass: 40 g. DC centrifugal fans Series RLF 35 51 x 51 x 15 mm 01234567 2 4 6 8 10 175 150 125 100 0,60,50,40,30,20,1 m³/h Pa CFM [in H2O] max. 9,6 m3/h HP Nominal voltage Air flow Air flow Voltage range Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Curve Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 Specials

max. 28 m3/h Nominal data Specials Type m 3/h CFM VDC VDC Bel(A) / Watts RPM °C Hours Hours P . 110 Highlights: – Pressure-optimised blower. – Noise-optimised air outlet in scroll housing. – Forward curved impeller. General characteristics: – Fibreglass-reinforced plastic scroll housing and impeller. – Fully integrated electronic commutation. – Protected against reverse polarity and locking. – Direction of air flow: axial air intake, centrifugal air exhaust out of the outlet. – Connection via single strands AWG 26, TR 64. Bared and tin-plated. – Mass: 75 g. DC centrifugal fans Series RL 48 76 x 76 x 27 mm 0369 1 2 1 5 51 0 100 125 0,40,30,20,1 m³/h Pa CFM [in H2O] HP N G Nominal voltage Air flow Air flow Voltage range Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Curve Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans

RL 65-21/12 56 33,0 12 6,8…13,8 6,6 15,0 4 500 -20…+70 60 000 / 30 000 120 000 1 /2 RL 65-21/14 56 33,0 24 12...26,4 6,6 14,0 4 500 -20…+70 60 000 / 30 000 120 000 1 Highlights: – Optional Vario-Pro: Highly adaptable software configuration of the fan enables a tailor-made solution to the specific requirements of your applications. – Pressure-optimised blower. Noise-optimised air outlet in scroll housing. – Forward curved impeller. – Integrated snap-in fins for easy assembly. General characteristics: – Fibreglass-reinforced plastic scroll housing and impeller. – Fully integrated electronic commutation. – Protected against reverse polarity and locking. – Direction of air flow: axial air intake, centrifugal air exhaust out of the outlet. – Connection via single strands AWG 26, TR 64. Bared and tin-plated. – Mass: 170 g. DC centrifugal fans Series RL 65 97 x 93,5 x 33 mm Nominal data Specials 10 20 300 10 20 200 300 400 30 40 50 60 100 1,61,20,80,4 m³/h Pa CFM [in H2O] Snap-in fins for easy assembly Type m 3/h CFM VDC VDC Bel(A) / Watts RPM °C Hours Hours P . 110 max. 61 m3/h HP A PWM I T N G Nominal voltage Air flow Air flow Voltage range Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Curve Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15

Type m 3/h CFM VDC VDC Bel(A) / Watts RPM °C Hours Hours P . 110 Highlights: – Optional Vario-Pro: Highly adaptable software configuration of the fan enables a tailor-made solution to the specific requirements of your applications. – Forward curved impeller. General characteristics: – Fibreglass-reinforced plastic scroll housing and impeller; Housing base of steel plate. – Fully integrated electronic commutation. – Protected against reverse polarity and locking. – Direction of air flow: axial air intake, centrifugal air exhaust out of the outlet. – Connection via single strands AWG 22, TR 64. Bared and tin-plated. – Mass: 420 g. DC centrifugal fans Series RL 90 N 121 x 121 x 37 mm 104,8 120,6 12±0,5 57,6 67,4 15,5 2 26,5 37,3 60,3 3,5 4,2 100,8 112,7 120,6 310 71,4 2,5 10+ 0,3_+ 0,2+ 0,2+ 0,2+ 0,3+ 0,4+ 0,4+ 0,2+ 0,7+ 0 5 10 15 20 25 30 10 20 100 125 150 175 200 0,80,60,40,2 m³/h Pa CFM [in H2O] max. 55 m3/h HP A SP IP54IP54/c219 PWM I T N G Nominal voltage Air flow Air flow Voltage range Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Curve Service life L10 ( 40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans

Highlights: – Very flat and powerful centrifugal fan. Pressure-optimised blower. – Optional Vario-Pro: Highly adaptable software configuration of the fan enables a tailor-made solution to the specific requirements of your applications. – Some models available as standard with PWM control input and speed signal. – Backward curved impeller. General characteristics: – Fibreglass-reinforced plastic scroll housing and impeller. Housing base of galvanised steel plate. – Fully integrated electronic commutation. Protected against reverse polarity and locking. – Direction of air flow: axial air intake, centrifugal air exhaust out of the outlet. – Connection via single strands AWG 22, TR 64. Bared and tin-plated. – Mass: 320 g. DC centrifugal fans Series RLF 100 127 x 127 x 25 mm Nominal data Specials Type m 3/h CFM VDC VDC Bel(A) / Watts RPM °C Hours Hours P . 110/116 10 2003 0 4 0 20 40 200 100 300 400 500 600 30 50 6010 1,6 2,01,20,80,4 m³/h Pa CFM [in H2O] max. 80 m3/h HP A IP54IP54/c219 PWM I T N G High speed models with Open Collector Tacho and PWM speed control. Nominal voltage Air flow Air flow Voltage range Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Curve Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15

Type m 3/h CFM VDC VDC Bel(A) / Watts RPM °C Hours Hours Highlights: – Optional Vario-Pro: Highly adaptable software configuration of the fan enables a tailor-made solution to the specific requirements of your applications. – Backward curved impeller. General characteristics: – Fibreglass-reinforced plastic scroll housing and impeller; Housing base of steel plate. – Fully integrated electronic commutation. – Protected against reverse polarity and locking. – Direction of air flow: axial air intake, centrifugal air exhaust out of the outlet. – Connection via single strands AWG 22, TR 64. Bared and tin-plated. 48 V Model: Flat plug 6.3 x 0.8 mm for protective earth. – Mass: 440 g. DC centrifugal fans Series RG 90 N 135 x 135 x 38 mm 0 5 10 15 20 25 30 10 20 100 30 40 50 0,30,20,1 m³/h Pa CFM [in H2O] max. 55 m3/h HP A SP IP54IP54/c219 PWM I T N G Nominal voltage Air flow Air flow Voltage range Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Curve Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans

Highlights: – Optional Vario-Pro: Highly adaptable software configuration of the fan enables a tailor-made solution to the specific requirements of your applications. – Backward curved impeller. General characteristics: – Fibreglass-reinforced plastic scroll housing and impeller; Housing base of steel plate. – Fully integrated electronic commutation. – Protected against reverse polarity and locking. – Direction of air flow: axial air intake, centrifugal air exhaust out of the outlet. – Connection via single strands AWG 22, TR 64. Bared and tin-plated. 48 V Model: Flat plug 6.3 x 0.8 mm for protective earth. – Mass: 730 g. DC centrifugal fans Series RG 125 N 180 x 180 x 40 mm Nominal data Specials Type m 3/h CFM VDC VDC Bel(A) / Watts RPM °C Hours Hours P . 110/112 0 1 02 03 04 05 0 20 40 100 60 80 150 125 0,50,40,30,20,1 m³/h Pa CFM [in H2O] 2004 0 6 0 8 0 20 40 120 180 240 300 360 420 60 80 100 120 1,20,80,4 m³/h Pa CFM [in H2O] max. 137 m3/h HP A SP IP54IP54/c219 PWM I T N G Nominal voltage Air flow Air flow Voltage range Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Curve Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15

Type m 3/h CFM VDC VDC Bel(A) / Watts RPM °C Hours Hours P . 112 Highlights: – Optional Vario-Pro: Highly adaptable software configuration of the fan enables a tailor-made solution to the specific requirements of your applications. – Backward curved impeller. General characteristics: – Fibreglass-reinforced plastic scroll housing and impeller; Housing base of steel plate. – Fully integrated electronic commutation. – Protected against reverse polarity and locking. – Direction of air flow: axial air intake, centrifugal air exhaust out of the outlet. – Connection via single strands AWG 22, TR 64. Bared and tin-plated. – 48 V Model: Flat plug 6.3 x 0.8 mm for protective earth. – Mass: 1.4 kg. DC centrifugal fans Series RG 160 N 220 x 220 x 56 mm 0 20 40 60 80 25 50 100 75 100 125 150 150 200 250 300 350 m³/h Pa CFM [in H2O] max. 209 m3/h HP A SP IP54IP54/c219 PWM I T N G Nominal voltage Air flow Air flow Voltage range Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Curve Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans

Type m 3/h CFM VDC VDC Bel(A) / Watts RPM °C Hours Hours P . Highlights: – Control inputs, alarm and speed signals available on request. – 3-phase fan drive with high degree of running smoothness. – Very high pressure build-up. – Backward curved impeller. General characteristics: – Fibreglass-reinforced plastic scroll housing and impeller; Housing base of sheet steel. – Fully integrated electronic commutation. – Direction of air flow: axial air intake, centrifugal air exhaust out of the outlet. – Connection via single strands AWG 22, TR 64. Bared and tin-plated. 48 V Model: Flat plug 6.3 x 0.8 mm for protective earth. – Mass: 1.4 kg. DC centrifugal fans Series RG 160 NTD 220 x 220 x 56 mm 0 30 60 90 120 150 50 100 100 150 300 400 500 600 700 200 200 250 nmax nmin m³/h Pa CFM [in H2O] 0 50 100 150 200 250 100 200 400 600 800 200 300 400 m³/h Pa 3,2 1000 4,0 1200 4,8 1400 2,41,60,8 CFM [in H2O] Specials max. 444 m3/h HP A PWM I T N G Nominal voltage Air flow Air flow Voltage range Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Curve Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 RG 160-28/14 NTD... 59 16,4 24 16...28 — 2,0 800 -20...+60 55 000 / 27 500 110 000 308 85,6 7,5 64,0 4 200 2 RG 160-28/18 NTD... 59 16,4 48 38...57 — 2,0 800 -20...+70 55 000 / 27 500 110 000 308 85,6 7,5 59,0 4 200 2 The data specified here are technically feasible benchmark values. The fans can be specially adapted to your application with signal outputs and control inputs. *The specific service life is valid when an external capacitor is wired between the plus and minus strands. Please note the wiring suggestion. min. max. min. max. NEW

6,0 79 0,3 1,0 0,5 + + +- 0,5 266 200 400 600 800 0 200 300 [CFM] [Pa] 100 200 300 400 500 600 700 800 900 0,5 1 1,5 2 1,5 3,5 [in H 2O] /h] 100 400 500 Speed control range from 800 rpm at 7 % PWM up to nominal speed at > 90 % PWM. Standstill at 0 % PWM, standstill if control cable is interrupted. For suitable guard grilles, see page 176. max. 930 m3/h Highlights: – 3-phase fan drive with high degree of running smoothness. Very high pressure build-up. – Backward-curved RadiCal impeller with high efficiency. – Standard models available with multifunctional control input for analogue, PWM and speed sign. – Compact design with integrated mounting plate and optimised inlet nozzle. General characteristics: – Housing and impeller of fibreglass-reinforced plastic. – Fully integrated electronic commutation. – Direction of rotation: CW seen on rotor. – Direction of air flow: axial air intake, centrifugal air exhaust out of the outlet. – Connection via single strands AWG 18, 20 or AWG 22, TR 64, speed signal and control input AWG 22, bared and tin-plated. – Mass: 1210 g. DC centrifugal fans Series RG 190 TD 225 x 225 x 85 mm HP A SP IP54IP54/c219 PWM I T N G NEW NEW NEW NEW NEW Nominal data Specials Type m 3/h CFM VDC VDC Bel(A) / Watts RPM °C Hours Hours Nominal voltage Air flow Air flow Voltage range Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Curve Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans

A IP54IP54/c219 PWM I T N G 350 243,2 0,5 7,0 92 0,3 1,0+ + +- 0,5 305 200 400 600 800 1000 1200 0 200 300 [CFM] [Pa] 100 200 300 400 500 600 0,25 0,5 0,75 1 1,25 1,5 1,75 2,25 [in H 2O] [m3/h] 100 400 500 600 700 Highlights: – 3-phase fan drive with high degree of running smoothness. Very high pressure build-up. – Backward-curved impeller. – Standard models available with multifunctional control input for analogue, PWM and speed signal. – Compact design with integrated mounting plate and optimised inlet nozzle. General characteristics: – Housing and impeller of fibreglass-reinforced plastic. – Fully integrated electronic commutation. – Direction of rotation: CW seen on rotor. – Direction of air flow: axial air intake, centrifugal air exhaust out of the outlet. – Connection via single strands AWG 18, 20 or AWG 22, TR 64, speed signal and control input AWG 22, bared and tin-plated. – Mass:1870 g. DC centrifugal fans Series RG 220 TD 270 x 270 x 99 mm max. 1280 m3/h Nominal data Specials Type m 3/h CFM VDC VDC Bel(A) / Watts RPM °C Hours Hours Nominal voltage Air flow Air flow Voltage range Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Curve Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 NEW NEW NEW Speed control range from 800 rpm at 7 % PWM up to nominal speed at > 90 % PWM. Standstill at 0 % PWM, standstill if control cable is interrupted. For suitable guard grilles, see page 176.

A PWM I T N G 350 243,2 7,0 112 0,3 1,0 0,5 + + +- 0,5 305 200 400 600 800 1000 1200 0 200 300 [CFM] [Pa] 100 200 300 400 500 600 0,25 0,5 0,75 1 1,25 1,5 1,75 2,25 [in H 2O] /h] 100 400 500 600 700 Highlights: – 3-phase fan drive with high degree of running smoothness. Very high pressure build-up. – Backward-curved RadiCal impeller with high efficiency. – Standard models available with multifunctional control input for analogue, PWM and speed sign. – Compact design with integrated mounting plate and optimised inlet nozzle. General characteristics: – Housing and impeller of fibreglass-reinforced plastic. – Fully integrated electronic commutation. – Direction of rotation: CW seen on rotor. – Direction of air flow: axial air intake, centrifugal air exhaust out of the outlet. – Connection via single strands AWG 18, 20 or AWG 22, TR 64, speed signal and control input AWG 22, bared and tin-plated. – Mass:1750 g. DC centrifugal fans Series RG 225 TD 270 x 270 x 119 mm max. 1210 m3/h Nominal data Specials Type m 3/h CFM VDC VDC Bel(A) / Watts RPM °C Hours Hours Nominal voltage Air flow Air flow Voltage range Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Curve Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 NEW NEW NEW Speed control range from 800 rpm at 7 % PWM up to nominal speed at > 90 % PWM. Standstill at 0 % PWM, standstill if control cable is interrupted. The specific service life is valid when an external capacitor is wired between the plus and minus strands. Please note the wiring suggestion. IP54IP54/c219 For suitable guard grilles, see page 176. InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans

40,5 24,4 7,951 ø 58,3 ø 47,1 310 M4 (4x) 25 50 75 100 1250 200 100 400 500 300 600 700 800 10050 150 200 2,41,60,8 m³/h Pa CFM [in H2O] The air flow and noise level of fans without external housing depends on the installation conditions. The stated air flow and noise levels have been measured under the following conditions: Centrifugal fan mounted on a base plate 116 x 116 mm. Cover plate 116 x 116 mm with an air inlet of Ø 80 mm, concentric to the impeller. R16 Air flow Air flow 2m m HP A PWM I T N G DC centrifugal fans Series RET 97 TD 9 7Øx4 1m m Highlights: – 3-phase fan drive with high degree of running smoothness. – Very high pressure build-up. – Forward curved impeller. – Available as standard with PWM control input and speed signal. Additional inputs and outputs on request. General characteristics: – Impeller of galvanised steel plate. – Fully integrated electronic commutation. – Direction of rotation: CW seen on rotor. – Direction of air flow: axial air intake, centrifugal air exhaust out of the outlet. – Connection via single strands AWG 22, TR 64. Bared and tin-plated. – Mass: 430 g. Type m 3/h CFM VDC VDC Bel(A) / Watts RPM °C Hours Hours Speed control range from 800 rpm at 7 % PWM up to nominal speed at > 90 % PWM. Standstill at 0 % PWM, maximum speed at sensor break. To attain the specified service life, an external capacitor must be wired between the plus and minus strands. Please note the wiring suggestion on page. * Preliminary Nominal data Specials Nominal voltage Air flow Air flow Voltage range Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Curve Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 max. 220 m3/h NEW NEW

Type m 3/h CFM VDC VDC Bel(A) / Watts RPM °C Hours Hours P . 110 Highlights: – Pressure-optimised blower. – Very flat and powerful centrifugal fan. – Optional Vario-Pro: Highly adaptable software configuration of the fan enables a tailor-made solution to the specific requirements of your applications. – Backward curved impeller. General characteristics: – Fibreglass-reinforced plastic scroll housing and impeller. – Fully integrated electronic commutation. – Protected against reverse polarity and locking. – Direction of air flow radial, direction of rotation clockwise, seen on rotor. – Connection via single strands AWG 22, TR 64. Bared and tin-plated – Mass: 160 g DC centrifugal fans Series REF 100 10 4Øx2 5m m 24,9 22,4 O7 2 O5 6 5,7 +- 0,3 +- 0,4 +- 0,3 M 4 (3x) 6 tief10 2003 0 4 0 5 0 20 40 60 80 100 100 200 300 400 500 1,61,20,80,4 m³/h Pa CFM [in H2O] The air flow and noise level of fans without external housing depends on the installation conditions. The stated air flow and noise levels have been measured under the following conditions: Centrifugal fan mounted on a base plate 127 x 127 mm. Cover plate 127 x 127 mm with an air inlet of Ø 70 mm, concentric to the impeller. R 3,5 Air flow Air flow 2m m Nominal data Specials max. 104 m3/h HP A IP54IP54/c219 PWM I T N G Nominal voltage Air flow Air flow Voltage range Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Curve Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans 6 deep

Highlights: – Optional Vario-Pro: Highly adaptable software configuration of the fan enables a tailor-made solution to the specific requirements of your applications. – Backward curved impeller. General characteristics: – Fibreglass-reinforced plastic scroll housing and impeller. – Fully integrated electronic commutation. – Protected against reverse polarity and locking. – Direction of air flow radial, direction of rotation clockwise, seen on rotor. – Connection via single strands AWG 22, TR 64. Bared and tin-plated – Mass: 305 g. DC centrifugal fans Series RER 101 10 1Øx5 2m m Nominal data Specials Type m 3/h CFM VDC VDC Bel(A) / Watts RPM °C Hours Hours P . 116 36,7 6,0 7,0 8,0 50,25 O6 0 M 4 (3x) 10 tief 51,7 +- 0,2 +- 0,45 +- 0,55 +- 0,95 +- 0,2 +- 0,9 0 2 04 06 08 0 1 0 0 25 50 100 75 100 125 150 200 300 400 1,51,00,5 m³/h Pa CFM [in H2O] The air flow and noise level of fans without external housing depends on the installation conditions. The stated air flow and noise levels have been measured under the following conditions: Centrifugal fan mounted on a base plate 148 x 148 mm. Cover plate 148 x 148 mm with an air inlet of Ø 66 mm, concentric to the impeller. Air flow Air flow 1m m max. 190 m3/h HP A PWM I T N G Nominal voltage Air flow Air flow Voltage range Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Curve Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 10 deep

13,5 1,5 ø 58,3 ø120 310 ø 47,1 M4 (4x) 0,5+ max. 8 tief 50 100 150 2000 100 200 300 100 200 300 400 500 600 1,60,8 m³/h Pa CFM [in H2O] The air flow and noise level of fans without external housing depends on the installation conditions. The stated air flow and noise levels have been measured under the following conditions: Centrifugal fan mounted on a base plate 140 x 140 mm. Cover plate 140 x 140 mm with an air inlet of Ø 96 mm, concentric to the impeller. R16 Air flow Air flow 2m m HP A PWM I T N G DC centrifugal fans Series RER 120 TD 12 0Øx5 4m m max. 390 m3/h Highlights: – 3-phase fan drive with high degree of running smoothness. – Very high pressure build-up. – Backward curved impeller. – Available as standard with PWM control input and speed signal. Additional inputs and outputs on request. General characteristics: – Impeller of fibreglass-reinforced plastic. – Fully integrated electronic commutation. – Direction of rotation: CW seen on rotor. – Direction of air flow: axial air intake, centrifugal air exhaust out of the outlet. – Connection via single strands AWG 22, TR 64. Bared and tin-plated. – Mass: 430 g. Type m 3/h CFM VDC VDC Bel(A) / Watts RPM °C Hours Hours Speed control range from 800 rpm at 7 % PWM up to nominal speed at > 90 % PWM. Standstill at 0 % PWM, max. speed if control cable is interrupted. The specific service life is valid when an external capacitor is wired between the plus and minus strands. Please note the wiring suggestion. *Preliminary Nominal data Specials Nominal voltage Air flow Air flow Voltage range Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Curve Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 NEW NEW NEW NEW InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans max. 8 deep

Type m 3/h CFM VDC VDC Bel(A) / Watts RPM °C Hours Hours P . 112 Highlights: – Optional Vario-Pro: Highly adaptable software configuration of the fan enables a tailor-made solution to the specific requirements of your applications. – Backward curved impeller. General characteristics: – Fibreglass-reinforced plastic scroll housing and impeller. – Fully integrated electronic commutation. – Protected against re verse polarity and locking. – Direction of air flow radial, direction of rotation clockwise, seen on rotor. – Connection via single strands AWG 22, TR 64. Bared and tin-plated. – Mass: 320 g. DC centrifugal fans Series RER 125 N 13 8Øx3 5m m ø56 M4 (2x) 5 tief ø47 400 ø125 4 19 30,74 35 0,3+ 0,5+ 10+ 2004 0 6 0 8 0 25 50 100 150 200 75 100 125 0,6 0,80,40,2 m³/h Pa CFM [in H2O] The air flow and noise level of fans without external housing depends on the installation conditions. The stated air flow and noise levels have been measured under the following conditions: Centrifugal fan mounted on a base plate 220 x 220 mm. Cover plate 220 x 220 mm with an air inlet of Ø 86 mm, concentric to the impeller. Airflow Airflow 2m m max. 166 m3/h HP A PWM I T N G Nominal voltage Air flow Air flow Voltage range Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Curve Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 5 deep

30,4 1,5 ø7 2 ø133 425 ø5 8 M4 (4x) 0,1 10 + + 0,3+ 0,5+ max. 8 tief 50 100 150 200 250 3000 200 400 600 100 200 300 400 500 2,41,60,8 m³/h Pa CFM [in H2O] The air flow and noise level of fans without external housing depends on the installation conditions. The stated air flow and noise levels have been measured under the following conditions: Centrifugal fan mounted on a base plate 140 x 140 mm. Cover plate 140 x 140 mm with an air inlet of Ø 87 mm, concentric to the impeller. Air flow Air flow 2m m HP A PWM I T N G DC centrifugal fans Series RER 133 TD 13 3Øx9 1m m max. 565 m3/h Highlights: – 3-phase fan drive with high degree of running smoothness. – Very high pressure build-up. – Backward curved impeller. – Available as standard with PWM control input and speed signal. Additional inputs and outputs on request. General characteristics: – Impeller of fibreglass-reinforced plastic. – Fully integrated electronic commutation. – Direction of rotation: CW seen on rotor. – Direction of air flow: axial air intake, centrifugal air exhaust out of the outlet. – Connection via single strands AWG 22, TR 64. Bared and tin-plated. – Mass: 890 g. Type m 3/h CFM VDC VDC Bel(A) / Watts RPM °C Hours Hours Speed control range from 800 rpm at 7 % PWM up to nominal speed at > 90 % PWM. Standstill at 0 % PWM, max. speed if control cable is interrupted. *Preliminary Nominal data Specials Nominal voltage Air flow Air flow Voltage range Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Curve Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 NEW NEW NEW NEW InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans max. 8 deep

Highlights: – Optional Vario-Pro: Highly adaptable software configuration of the fan enables a tailor-made solution to the specific requirements of your applications. – Backward curved impeller. General characteristics: – Fibreglass-reinforced plastic scroll housing and impeller. –F u lly integrated electronic commutation. – Protected against reverse polarity and locking. – Direction of air flow radial, direction of rotation clockwise, seen on rotor. – Connection via single strands AWG 22, TR 64. Bared and tin-plated – Mass: 590 g. DC centrifugal fans Series RER 160 N 16 5Øx5 1m m Nominal data Specials Type m 3/h CFM VDC VDC Bel(A) / Watts RPM °C Hours Hours P . 112 50,3 6,1 0,7+ 0,8+ ø7 2 ø160 425 ø5 8 M4 (4x) 0,1+ 0,3+ 0,5+ max. 8 tief 0 2 04 06 08 0 1 0 0 1 2 0 200 100 150 200 150 100 0,80,60,40,2 m³/h Pa CFM [in H2O] The air flow and noise level of fans without external housing depends on the installation conditions. The stated air flow and noise levels have been measured under the following conditions: Centrifugal fan mounted on a base plate 260 x 260 mm. Cover plate 260 x 260 mm with an air inlet of Ø 100 mm, concentric to the impeller. Airflow Airflow 2m m max. 255 m3/h HP A SP IP54IP54/c219 PWM I T N G Nominal voltage Air flow Air flow Voltage range Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Curve Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15max. 8 deep

max. 505 m3/h Highlights: – Control inputs, alarm and speed signals available on request. – 3-phase fan drive with high degree of running smoothness. – High pressure build-up. – Backward curved impeller. General characteristics: – Fibreglass-reinforced plastic scroll housing and impeller; Housing base of steel plate. – Fully integrated electronic commutation. – Direction of air flow: axial air intake, centrifugal air exhaust out of the outlet. – Connection via single strands AWG 22, TR 64. Bared and tin-plated. – Mass: 590 g. DC centrifugal fans Series RER 160 NTD 16 5Øx5 1m m 50,3 6,1 0,7+ 0,8+ ø7 2 ø160 425 ø5 8 M4 (4x) 0,1+ 0,3+ 0,5+ max. 8 tief 05 0 50 100 200 400 500 300 150 200 250 100 100 150 nmin nmax 1,61,20,80,4 m³/h Pa CFM [in H2O] The air flow and noise level of fans without external housing depends on the installation conditions. The sta- ted air flow and noise levels have been measured under the following conditions: Centrifugal fan mounted on a base plate 260 x 260 mm. Cover plate 260 x 260 mm with an air inlet of Ø 100 mm, concentric to the impeller. Nominal data Specials Type m 3/h CFM VDC VDC Bel(A) / Watts RPM °C Hours Hours P . HP A PWM I T N G Nominal voltage Air flow Air flow Voltage range Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Curve Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 100 400 800 1000 600 200 300 400 200 100 150 25050 3,2 4,02,41,60,8 m³/h Pa CFM [in H2O] 200 RER 160-28/18 NTD... 66 18,3 48 38...57 — 2,0 800 -20...+70 55 000 / 27 500 110 000 354 98,3 7,4 43,0 4 200 2 min. max. Model RER 160-28/18 NTD... is available in customer-specific, custom-developed variant only. The data specified here are technically feasible benchmark values. The fans can be specially adapted to your application with signal outputs and control inputs. *The specific service life is valid when an external capacitor is wired between the plus and minus strands. Please note the wiring suggestion. NEW NEW InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans max. 8 deep

A PWM I T N G 6,8 54,3 0,8 0,1 0,3 1,0 425 ø58 ø72 ø175 M4 (4x) max. 8tief 100 200 300 400 5000 200 400 600 800 100 200 300 400 500 600 1,60,8 m³/h Pa CFM [in H2O] The air flow and noise level of fans without external housing depends on the installation conditions. The stated air flow and noise levels have been measured under the following conditions: Centrifugal fan mounted on a base plate 180 x 180 mm. Cover plate 180 x 180 mm with an air inlet of Ø 125,5 mm, concentric to the impeller. R10 Air flow Air flow 2m m DC centrifugal fans Series REF 175 TD 17 5Øx5 5m m max. 800 m3/h Highlights: – 3-phase fan drive with high degree of running smoothness. – Very high pressure build-up. Backward curved impeller. – Available as standard with PWM control input and speed signal. Additional inputs and outputs on request. General characteristics: – Impeller of galvanised steel plate. – Fully integrated electronic commutation. – Direction of rotation: CW seen on rotor. – Direction of air flow: axial air intake, centrifugal air exhaust out of the outlet. – Connection via single strands AWG 20, TR 64, speed signal and control input AWG 22, bared and tin-plated. – Mass: 930 g. Type m 3/h CFM VDC VDC Bel(A) / Watts RPM °C Hours Hours Speed control range from 800 rpm at 7 % PWM up to nominal speed at > 90 % PWM. Standstill at 0 % PWM, max. speed if control cable is interrupted. Nominal data Specials Nominal voltage Air flow Air flow Voltage range Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Curve Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 NEW max. 8 deep

A PWM I T N G 6,8 0,8+ ø7 2 ø175 425 ø5 8 M4 (4x) 0,1+ 0,3+ 0,5+ max. 8 tief 1000 200 800 400 200 300 600 400 500 800 200 400 600 2,41,60,8 3,2 m³/h Pa CFM [in H2O] The air flow and noise level of fans without external housing depends on the installation conditions. The stated air flow and noise levels have been measured under the following conditions: Centrifugal fan mounted on a base plate 180 x 180 mm. Cover plate 180 x 180 mm with an air inlet of Ø 125,5 mm, concentric to the impeller. R10 Air flow Air flow 2m m max. 980 m3/h DC centrifugal fans Series RER 175 TD 17 5Øx6 9m m Highlights: – 3-phase fan drive with high degree of running smoothness. – Very high pressure build-up. Backward curved impeller. – Available as standard with PWM control input and speed signal. Additional inputs and outputs on request. General characteristics: – Impeller of fibreglass-reinforced plastic. – Fully integrated electronic commutation. – Direction of rotation: CW seen on rotor. – Direction of air flow: axial air intake, centrifugal air exhaust out of the outlet. – Connection via single strands AWG 18, 20 or AWG 22, TR 64, speed signal and control input AWG 22, bared and tin-plated. – Mass: 775 g. Type m 3/h CFM VDC VDC Bel(A) / Watts RPM °C Hours Hours Speed control range from 800 rpm at 7 % PWM up to nominal speed at > 90 % PWM. Standstill at 0 % PWM, max. speed if control cable is interrupted. * preliminary data Nominal data Specials Nominal voltage Air flow Air flow Voltage range Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Curve Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 NEW NEW NEW NEW NEW SP IP54IP54/c219 InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans max. 8 deep

6,5 190 58M4 (4x) 0,1+ 0,3+ 0,3+ max. 8 tief 425 200 400 600 800 1000 0 200 300 [CFM] [Pa] 100 200 300 400 500 600 700 800 900 0,5 1 1,5 2 1,5 3,5 [in H 2O] /h] 100 400 500 600 The air flow and noise level of fans without external housing depends on the installation conditions. The stated air flow and noise levels have been measured under the following conditions: Centrifugal fan mounted on a base plate 195 x 195 mm. Cover plate 195 x 195 mm with an air inlet of Ø 125,5 mm, concentric to the impeller. R10 Air flow Air flow 2m m HP A SP IP54IP54/c219 PWM I T N G Highlights: – 3-phase fan drive with high degree of running smoothness. – Very high pressure build-up. – Backward curved RadiCal impeller with maximum efficiency. – Standard models available with multifunctional control input for analogue, PWM and speed signal. General characteristics: – Impeller of fibreglass-reinforced plastic. – Fully integrated electronic commutation. – Direction of rotation: CW seen on rotor. – Direction of air flow: axial air intake, centrifugal air exhaust out of the outlet. – Connection via single strands AWG 18, 20 or AWG 22, TR 64, speed signal and control input AWG 22, bared and tin-plated. – Mass: 870 g. DC centrifugal fans Series RER 190 TD 19 0Øx6 9m m max. 970 m3/h Speed control range from 800 rpm at 7 % PWM up to nominal speed at > 90 % PWM. Standstill at 0 % PWM, standstill if control cable is interrupted. NEW NEW NEW NEW NEW Type m 3/h CFM VDC VDC Bel(A) / Watts RPM °C Hours Hours Nominal data Specials Nominal voltage Air flow Air flow Voltage range Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Curve Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 max. 8 deep

7,2 44,0 1,5 0,1 0,3 0,5 425 220,9 M4 (4x) max. 8 tief ø ø ø 200 400 600 800 1000 1200 0 200 300 [CFM] [Pa] 100 200 300 400 500 600 0,25 0,5 0,75 1 1,25 1,5 1,75 2,25 [in H 2O] /h] 100 400 500 600 700 The air flow and noise level of fans without external housing depends on the installation conditions. The stated air flow and noise levels have been measured under the following conditions: Centrifugal fan mounted on a base plate 230 x 230 mm. Cover plate 230 x 230 mm with an air inlet of Ø 146 mm, concentric to the impeller. R10 Air flow Air flow 2m m HP A IP54IP54/c219 PWM I T N G Highlights: – 3-phase fan drive with high degree of running smoothness. – Very high pressure build-up. – Backward curved impeller. – Standard models available with multifunctional control input for analogue, PWM and speed sign. General characteristics: – Impeller of fibreglass-reinforced plastic. – Fully integrated electronic commutation. – Direction of rotation: CW seen on rotor. – Direction of air flow: axial air intake, centrifugal air exhaust out of the outlet. – Connection via single strands AWG 18, 20 or AWG 22, TR 64, speed signal and control input AWG 22, bared and tin-plated. – Mass: 940 g. DC centrifugal fans Series RER 220 TD 22 1Øx7 1m m max. 1280 m3/h Type m 3/h CFM VDC VDC Bel(A) / Watts RPM °C Hours Hours Nominal data Specials Nominal voltage Air flow Air flow Voltage range Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Curve Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 NEW NEW NEW Speed control range from 800 rpm at 7 % PWM up to nominal speed at > 90 % PWM. Standstill at 0 % PWM, standstill if control cable is interrupted. InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans max. 8 deep

10,6 1,5 225 58M4 (4x) 0,1+ 0,3+ 0,5+ max. 8 tief 425 ø ø ø 200 400 600 800 1000 1200 1400 0 200 300 [CFM] [Pa] 100 200 300 400 500 600 700 0,25 0,5 0,75 1 1,25 1,5 1,75 2,25 [in H 2O] /h] 2,5 2,752 100 400 500 600 700 800 900 The air flow and noise level of fans without external housing depends on the installation conditions. The stated air flow and noise levels have been measured under the following conditions: Centrifugal fan mounted on a base plate 230 x 230 mm. Cover plate 230 x 230 mm with an air inlet of Ø 146 mm, concentric to the impeller. R10 Air flow Air flow 2m m HP A PWM I T N G Highlights: – 3-phase fan drive with high degree of running smoothness. – Very high pressure build-up. – TDM and TDML model with backward-curved RadiCal impeller with maximum efficiency. – Standard models available with multifunctional control input for analogue, PWM and speed signal. General characteristics: – Impeller of fibreglass-reinforced plastic. – Fully integrated electronic commutation. – Direction of rotation: CW seen on rotor. – Direction of air flow: axial air intake, centrifugal air exhaust out of the outlet. – Connection via single strands AWG 18, 20 or AWG 22, TR 64, speed signal and control input AWG 22, bared and tin-plated. – Mass: 1030 g. DC centrifugal fans Series RER 225 TD 22 5Øx9 9m m max. 1600 m3/h Speed control range from 800 rpm at 7 % PWM up to nominal speed at > 90 % PWM. Standstill at 0% PWM, Type O: standstill at sensor break. Type P: maximum speed at sensor break. NEW NEW NEW Type m 3/h CFM VDC VDC Bel(A) / Watts RPM °C Hours Hours Nominal data Specials Nominal voltage Air flow Air flow Voltage range Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Curve Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 8,6 62,0 0,8 0,1 0,3 0,5 425 ø5 8 ø7 2 max. ø 225 M4 (4x) max. 8 tief Type RER 225-63 Type RER 225-55 IP54IP54/c219 max. 8 deepmax. 8 deep

max. 155 m3/h HP Highlights: – Tangential fans with high air flow. – Large air outlet. General characteristics: – Motor with ball bearing system. Impeller mounting plate with sleeve bearings. – Fan housing and impeller of aluminium. Plastic housing side parts. – Fully integrated electronic commutation. – Protected against reverse polarity and locking. – Air exhaust out of the outlet. – Connection via single strands. Bared and tin-plated. – Mass: 235 / 290 / 380 / 415 g. DC tangential fan Series QG 030 201...413 x 50 x 48 mm Nominal voltage Air flow Air flow Voltage range Sleeve bearings Ball bearings Power input Temperature rangeNominal data Curve Type m 3/h CFM VDC VDC db(A) Bel(A) / Watts °C Hours Hours L 5,4 ±0,7 +0,3 Ø35,1 Ø41 1010 Cutout for squarenut M3 DIN 562-flat (6x) 300 ±10 47,5 10 34,4 21,516,5 3,2 38,4 Ø2,3 (8x) 0 1 53 04 56 07 5 20 40 60 80 100 120 1 2 3 4 0,150,100,05 m³/h Pa CFM [in H2O] Type Dimension: L L 1 QG 030-148/ .. 201 +1,5 148 QG 030-198/ .. 258 +1,5 198 QG 030-303/ .. 363 +1,5 303 QG 030-353/ .. 413 +1,5 353 The service life values refer to horizontal installation of the fan. Tangential fans are only suitable for operation with high rate and low back pressure. Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) see P . 15 InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans Sound pressure level Sound power level Specials Cut-out for square nut M3 DIN 562, flat (6x)

Vario-Pro / Speed setting / Control input 119 Protection against ambient influences 123 InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans

Cooling capacity and efficiency Greater power density, increasing miniaturisation and extreme electronic component density are posing increased demands on the cooling capacity and efficiency of fans. The intelligent and space-saving integration of the fan in the device configuration is therefore of major importance:

  • Tailor-made cooling adapted to the situation as and when required.
  • Programmable cooling by defining speed profiles.
  • Transparency of function thanks to complete, interactive monitoring in all operating conditions. ebm-papst provides intelligent cooling concepts which are optimally adapted to requirements. For example: 1. Speed adaptation via NTC sensor Standard fans in electronics cooling– tried and tested by the millions and nevertheless a temporary solution, because standard fans have a distinct disadvantage: With constant speed and a corresponding high noise factor, they continuously provide the air flow required in extreme cases. This extreme case only occurs-, if it occurs at all-, for a fraction of the service life. What is needed is an intelligent fan that automatically adapts to the current cooling requirements. The ebm-papst answer: A complete range of DC fans with temperature-controlled speed adapta- tion - in all standard dimensions. Installation is simple. The control electronics receive their thermal information for speed adaptation steplessly and loss-free via a tem- perature sensor either externally via a single lead, positioned as required, or internally direct- ly in the fan hub in the air flow. 2. DC fans with separate control input Open or closed-loop speed control is also possi- ble with DC fans that have a separate control input. A variation in speed can thus be imple- mented via a control voltage or a pulse-width modulated signal. These possibilities are used primarily in devices that have appropriate stan- dard interfaces and thus require a load-depend- ent variation of the fans. Technical information

A PWM 3. Sensor signal DC fans with sensor signal. The integrated „electronic tachometer“ continu- ously provides an actual speed signal for exter- nal evaluation. The user is informed at all times of the current fan speed via an extremely sim- ple signal evaluation on the customer side. The sensor signal is via a separate lead. 4. Alarm signal For applications which require monitored fan operation with alarm signal, ebm-papst has numerous alarm signal versions, either a static, pre-processed or interface-compatible high or low continuous signal depending on the type of fan. 5. Turbo drives Fans with three-phase EC drives and micro- processor-controlled motor electronics. These three-phase motors whose torque is virtually non-reliant on the rotor position are used for extremely high running smoothness. The speed of these fans can be controlled over a very wide range with PWM, analogue voltage or tempera- ture. Optionally, the fans can be supplied with reversible direction of rotation and active brake operation. 6. Vario-Pro fans This high-end fan concept by ebmpapst with pro- grammed intelligence and customer-specific inte- grated functions makes your electronics cooling even more versatile and competitive. Vario-Pro ensures a fresh economic breeze for all demanding cooling tasks – e.g. where greater reliability, more flexibility and intelligent function features such as alarm function, speed control etc. are required. The successful concept of Vario-Pro is: Tailor-made software instead of fixed hardware, because pro- grammed software modules for motor control and application intelligence are responsible for the work that analogue components were responsible for in the past. This central control unit of the Vario-Pro comprises a microcontroller and an EEPROM, on which all characteristics are stored. 7. Protection against environmental influences Some applications place particular demands on the fans' resistance to ambient influences, such as dust, moisture, water and salt. ebm-papst offer solutions for adapting fans to these ambient condi- tions. Technical information InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans

Condition: Isink Speed signal US High Condition: Isource Sensor operating voltage UBS Perm. sink current Isink max. Pulses per revolution Fan descriptionSignal data Electrical connection sU s n sU t t t U U n n min max

2 Pulse / Rotation

Signal frequenzy [F]= 2 x n/60 Hz

1 Rotation

3 Pulse / Rotation

Signal frequenzy [F]= 3 x n/60 Hz t t t t Signal output voltage Standard signal for all models (exceptions see below) only for 4100 NH7 and NH8 Fa n Speed sU t U

6 Pulse / Rotation

Signal frequenzy [F]= 6 x n/60 Hz

6200 NTD, 6400 TD, DV 6200 TD, DV 6400 TD, RER / RG 160 NTD

(+) Power output Fan Customer (-) Power Isink UB +UBS US UB All voltages measured to ground. External load resistor Ra /U S /U BS required. – Speed-proportional rectangular pulse for external speed monitoring of fan motor. – 2, 3 or 6 pulses per revolution. – Open collector signal output. – Extremely wide operating voltage range. – Easy adaptation to user interface. – Connection via separate lead. – The sensor signal also serves as a major comparison variable for setting and maintaining the setpoint speed for interactive or controlled cooling with one or several interconnected fans. Type VDC mA VDC mA VDC mA Page 250 ≤ 0,4 ≤ 23 0 0 ≤ 30 2 2 23

400 F ≤ 0,4 1 30 0 ≤ 30 ≤ 222 4

400 ≤ 0,4 1 30 0 ≤ 30 ≤ 222 5

400 J ≤ 0,4 2 30 0 ≤ 30 ≤ 422 6

500 F ≤ 0,4 1 30 0 ≤ 30 ≤ 222 7

600 F ≤ 0,4 1 30 0 ≤ 30 ≤ 222 8

620 ≤ 0,4 2 30 0 ≤ 30 ≤ 422 9

630 U ≤ 0,4 2 30 0 ≤ 30 ≤ 423 0

600 N ≤ 0,4 2 28 0 ≤ 28 ≤ 423 1

600 J ≤ 0,4 2 30 0 ≤ 30 ≤ 423 3

700 F ≤ 0,4 2 30 0 ≤ 30 ≤ 423 4

8450 ≤ 0,4 2 28 0 ≤ 28 ≤ 423 5

8400 N ≤ 0,4 2 28 0 ≤ 28 ≤ 423 6

8400 N VARIOFAN ≤ 0,4 2 30 0 ≤ 30 ≤ 423 7

8300 ≤ 0,4 2 30 0 ≤ 30 ≤ 423 8

8200 J ≤ 0,4 2 30 0 ≤ 30 ≤ 423 9

3400 N ≤ 0,4 2 28 0 ≤ 28 ≤ 424 0

3400 N VARIOFAN ≤ 0,4 2 30 0 ≤ 30 ≤ 424 1

3300 ≤ 0,4 2 30 0 ≤ 30 ≤ 424 2

3212 J / 3214 J ≤ 0,4 2 30 0 ≤ 30 ≤ 424 3

3218 J ≤ 0,4 2 60 0 ≤ 60 ≤ 424 3

4412 F / 4414 F ≤ 0,4 2 30 0 ≤ 30 ≤ 424 4

4418 F ≤ 0,4 2 60 0 ≤ 60 ≤ 424 4

4400 FN ≤ 0,4 2 30 0 ≤ 30 ≤ 424 5

4312 / 4314 ≤ 0,4 2 30 0 ≤ 30 ≤ 424 6 4318 ≤ 0,4 2 60 0 ≤ 60 ≤ 424 6 4312 / 4314 VARIOFAN ≤ 0,4 2 30 0 ≤ 30 ≤ 424 7

4318 VARIOFAN ≤ 0,4 2 60 0 ≤ 60 ≤ 424 7

4400 ≤ 0,4 2 30 0 ≤ 30 ≤ 424 8

4100 N ≤ 0,4 2 30 0 ≤ 30 ≤ 424 9

4100 NHH...NH6 ≤ 0,4 2 ≤ 60 0 ≤ 60 ≤ 10 2 50 4100 NH7...NH8 ≤ 0,4 2 ≤ 60 0 ≤ 60 ≤ 20 3 51 DV 4100 ≤ 0,4 2 30 0 ≤ 30 ≤ 425 2

5200 N ≤ 0,4 2 30 0 ≤ 30 ≤ 425 3

All TD fans. Ex.: 6400 TD

Type VDC mA VDC mA VDC mA Page DV 5200 ≤ 0,4 2 30 0 ≤ 30 ≤ 425 4

5112 N ≤ 0,4 2 15 0 ≤ 5 ≤ 20 2 55

5114 N / 5118 N ≤ 0,4 2 60 0 ≤ 60 ≤ 20 2 55

5300 ≤ 0,4 2 ≤ 72 0 ≤ 72 ≤ 425 6

5300 TD ≤ 0,4 2 72 0 ≤ 72 ≤ 20 6 57

7112 N / 7118 N ≤ 0,4 2 60 0 ≤ 60 ≤ 20 2 58

7114 N ≤ 0,4 2 30 0 ≤ 30 ≤ 20 2 58

7200 N ≤ 0,4 2 15 0 ≤ 15 ≤ 20 2 59

6300 ≤ 0,4 2 ≤ 72 0 ≤ 72 ≤ 20 2 61

6300 TD ≤ 0,4 2 72 0 ≤ 72 ≤ 20 6 62

DV 6200 ≤ 0,4 2 30 0 ≤ 60 ≤ 20 2 64 6400 ≤ 0,4 2 60 0 ≤ 60 ≤ 20 2 66

2200 FTD ≤ 0,4 2 72 0 ≤ 72 ≤ 20 6 70

RL 48 ≤ 0,4 2 3 0 ≤ 30 ≤ 428 1 RL 65 ≤ 0,4 2 30 0 ≤ 30 ≤ 428 2 RL 90 N ≤ 0,4 2 30 0 ≤ 30 ≤ 428 3 RLF 100 ≤ 0,4 2 30 0 ≤ 30 ≤ 428 4 RG 90 N ≤ 0,4 2 30 0 ≤ 30 ≤ 428 5 RG 125 N ≤ 0,4 2 30 0 ≤ 30 ≤ 428 6 RG 160 N ≤ 0,4 2 30 0 ≤ 30 ≤ 20 2 87 RG 160 TD ≤ 0,4 2 60 0 ≤ 60 ≤ 20 6 88 RG 190 TD ≤ 0,4 2 72 0 ≤ 72 ≤ 20 6 89 RG 220 TD ≤ 0,4 2 72 0 ≤ 72 ≤ 20 6 90 RG 225 TD ≤ 0,4 2 72 0 ≤ 72 ≤ 20 6 91 RET 97 TD ≤ 0,4 2 72 0 ≤ 72 ≤ 20 6 92 REF 100 ≤ 0,4 2 30 0 ≤ 30 ≤ 429 3 RER 120 TD ≤ 0,4 2 72 0 ≤ 72 ≤ 20 6 95 RER 133 TD ≤ 0,4 2 72 0 ≤ 72 ≤ 20 6 97 RER 160 TD ≤ 0,4 2 60 0 ≤ 60 ≤ 20 6 99 REF 175 TD ≤ 0,4 2 72 0 ≤ 72 ≤ 20 6 100 RER 175 TD ≤ 0,4 2 72 0 ≤ 72 ≤ 20 6 101 RER 190 TD ≤ 0,4 2 72 0 ≤ 72 ≤ 20 6 102 RER 220 TD ≤ 0,4 2 72 0 ≤ 72 ≤ 20 6 103 RER 225 TD ≤ 0,4 2 72 0 ≤ 72 ≤ 20 6 104 Speed signal USL o w Condition: Isink Speed signal U S High Condition: Isource Sensor operating voltage U BS Perm. sink current Isink max. Pulses per revolution Fan descriptionSignal data Attention: With these fan options, deviations in regard to temperature range, voltage range and power consumption are possible compared with standard fan data. Available on request: – Electrically isolated sensor and signal circuit. – Varying voltage potentials for power and logic circuit. InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans

Type VDC mA VDC mA mA Page Speed signal /12 sU s n sU t t t U U n n min max Signal frequenzy [F]= 2 x n/60 Hz Signal frequenzy [F]= 3 x n/60 Hz t t t t Signal output voltage Standard signal for all models (exceptions see below) only for 4100 NH7 and NH8 Fa n Speed sU t U Signal frequenzy [F]= 6 x n/60 Hz (+) Power output (-) Power US UB Fan Customer All voltages measured to ground. Speed signal USL o w Condition: Isink Speed signal US High Condition: Isource Perm. sink current Isink max. Fan descriptionSignal data – Speed-proportional rectangular pulse for external speed monitoring of fan motor. – 2, 3 or 6 pulses per revolution. – TTL-compatible. – Integrated pull-up resistor. – Connection via separate lead. – The sensor signal also serves as a major comparison variable for setting and maintaining. the setpoint speed for interactive or controlled cooling with one or more interconnected fans.

614 N/12 GM ≤ 0,4 1 2,5–5,5 1 1 31

618 N/12 N ≤ 0,4 1 2,5–5,5 1 1 31

8412 N/12 H ≤ 0,4 1 2,5–5,5 1 1 36

4412 F/12 GM ≤ 0,4 1 2,5–5,5 1 1 44

4418 F/12 ≤ 0,4 1 2,5–5,5 1 1 44

4312 /12 M ≤ 0,4 1 2,5–5,5 1 1 46 4314 /12 ≤ 0,4 1 2,5–5,5 1 1 46

4182 N/12 X ≤ 0,4 1 2,5–5,5 1 1 49

Attention: With these fan options, deviations in regard to temperature range, voltage range and power consumption are possible compared with standard fan data.. All TD fans. Ex.: 6400 TD

Type VDC mA VDC mA mA Page

7214 N/12 ≤ 0,4 2 2,5–5,5 1 ≤ 20 59

DV 6224 /12 ≤ 0,4 2 4,5–5,25 2 ≤ 12 64 6424 /12 H ≤ 0,4 2 2,5–5,5 1 ≤ 20 66 DV 6424 /12 ≤ 0,4 2 4,5–5,25 2 ≤ 12 68 DV 6448 /12 ≤ 0,4 2 4,5–5,25 2 ≤ 12 68 RG 125-19/12N/12 ≤ 0,4 1 2,5–5,5 1 ≤ 18 6 RG 160-28/12N/12 ≤ 0,4 2 2,5–5,5 1 ≤ 58 7 RG 160-28/18N/12 ≤ 0,4 2 2,5–5,5 1 ≤ 20 87 RER 125-19/12N/12 ≤ 0,4 1 2,5–5,5 1 ≤ 19 6 RER 160-28/12N/12 ≤ 0,4 2 2,5–5,5 1 ≤ 59 8 RER 160-28/18N/12 ≤ 0,4 2 2,5–5,5 1 ≤ 20 98 Speed signal USL o w Condition: Isink Speed signal US High Condition: Isource Perm. sink current Isink max. Fan descriptionSignal data Available on request: – Electrically isolated sensor and signal circuit. – Varying voltage potentials for power and logic circuit. Attention: With these fan options, deviations in regard to temperature range, voltage range and power consumption are possible compared with standard fan data. InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans

U= UAHigh BA UALow n>nG n<nG*) n>nG n>nG UB n nG UA t t t Speed Alarm Signal locked n=0 min-1 Supply Voltage (+) Power output Fan Customer (-) Power Isink UB +UBS US UB t2 = Alarm signal suppression during start-up * n < speed limit nG by braking or locking. All voltages measured to ground. External load resistor Ra from UA to UBA required. With VARIOFANs with external temperature sensor for controlling the motor speed, the NTC sensor is not included in the scope of delivery. Temperature sensor LZ 370, see Accessories. Electrical connection 8318 /17 ≤ 0 , 4 n<n G 2 6 0 n>n G 0 ≤ 60 20 ≤ 15 * 1500 ± 100 38 8318 /17 H ≤ 0 , 4 n<n G 2 6 0 n>n G 0 ≤ 60 20 ≤ 15 * 1500 ± 100 38 3314 /17 ≤ 0 , 4 n<n G 2 6 0 n>n G 0 ≤ 60 20 ≤ 15 * 1500 ± 100 42 3318 /17 H ≤ 0 , 4 n<n G 2 6 0 n>n G 0 ≤ 60 20 ≤ 15 * 1500 ± 100 42 4318 /17 ≤ 0 , 4 n<n G 2 6 0 n>n G 0 ≤ 60 20 ≤ 15 * 850 ± 100 46

4184 N /17 X ≤ 0 , 4 n<n G 2 6 0 n>n G 0 ≤ 60 20 ≤ 15 * 1500 ± 100 49

Type VDC mA VDC mA VDC mA S min –1 Page Alarm signal data Attention: With these fan specials, deviations as regards temperature range, voltage range and power consumption are possible compared with standard fans. – Alarm signal for speed monitoring. – Signal output via open collector. – The fan emits a high continuous signal during trouble-free operation within the permissible voltage range. – Low signal when speed limit is not reached. – After elimination of fault, the fan returns to its setpoint speed; the alarm signal reverts to high. Alarm output voltage UAL o w Condition: Condition: Isink = Alarm output- voltage UA High Condition: Condition: Isource Alarm operating- voltage UBA max. Max. permissible Sink current Alarm delay time t2 Condition: Speed limit nG Fan description

4312/17 MV ≤ 0 , 4 n<n G 2 6 0 n>n G 0 ≤ 60 20 ≤ 15 * 1500 ± 100 47 VARIOFAN 4312/17 T ≤ 0 , 4 n<n G 2 6 0 n>n G 0 ≤ 60 20 ≤ 15 * 1500 ± 100 47 VARIOFAN 4314/17 T ≤ 0 , 4 n<n G 2 6 0 n>n G 0 ≤ 60 20 ≤ 15 * 1150 ± 100 47 VARIOFAN 4318/17 V ≤ 0 , 4 n<n G 2 6 0 n>n G 0 ≤ 60 20 ≤ 15 * 850 ± 100 47 VARIOFAN

7214 N/17 ≤ 0 , 4 n<n G 2 6 0 n>n G 0 ≤ 60 15 ≤ 15 * 1330 ± 60 59

  • After switching on UB Type VDC mA VDC mA VDC mA S min –1 Page Attention: With these fan specials, deviations as regards temperature range, voltage range and power consumption are possible compared with standard fans. Available on request: – With integrated signal latching for subsequent recognition of short-time faults. – Alarm circuit open collector or TTL. – Electrically isolated for maximum device safety; Defects in the power circuit do not affect the alarm circuit. Alarm signal data InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans Alarm output voltage UAL o w Condition: Condition: Isink = Alarm output- voltage UA High Condition: Condition: Isource = Alarm operating- voltage UBA max. Max. permissible Sink current Alarm delay- time t2 Condition: Speed limit nG Fan description

U= UAHigh BA UALow n>nG n<nG*) n>nG n>nG UB nG UA t t t locked n=0 min-1 Speed Alarm Signal Supply Voltage (+) Power output Fan Customer (-) Power Isink UB +UBS US UB All voltages measured to ground. External load resistor Ra from UA to U BA required. Electrical connection t2 = Alarm signal suppression during start-up. * n < Speed limit nG by braking or locking. 8314 /19 H ≤ 0 , 4 n>n G 2 6 0 n<n G 0 ≤ 60 20 ≤ 15 * 1500 ± 100 38 4312 /19 ≤ 0 , 4 n>n G 2 6 0 n<n G 0 ≤ 60 20 ≤ 15 * 1500 ± 100 46

7214 N /19 ≤ 0,4 n > nG 2 60 n < nG 0 4,5–60 10 10 ± 4 * 1800 ± 20 59

RLF 100-11/14 /19 ≤ 0,4 n > nG 2 ≤ 28 n < nG 0 16–28 10 10 ± 4 * 1900 ± 100 84 RER 101-36/18N /19 HH ≤ 0,4 n > nG 2 ≤ 28 n < nG 0 16–28 10 10 ± 4 * 1900 ± 100 94 * After switching on UB Type VDC mA VDC mA VDC mA S min –1 Page Alarm signal data Attention: With these fan specials, deviations as regards temperature range, voltage range and power consumption are possible compared with standard fans. Available on request: – With integrated signal latching for subsequent recognition of short-term faults. – Alarm circuit open collector or TTL. – Electrically isolated for max. device safety; defects in power circuit have no effect on the alarm circuit. – Alarm signal for speed monitoring. – Signal output via open collector. – The fan emits a low continuous signal during trouble-free operation within the permissible voltage range. – High signal when speed limit is not reached. – After elimination of fault, the fan returns to its setpoint speed; the alarm signal reverts to low. Alarm output voltage UAL o w Condition: Condition: Isink = Alarm output voltage UA High Condition: Condition: Isource = Alarm operating- voltage UBA max. Max. permissible Sink current Alarm delay- time t2 Condition: Speed limit nG Fan description

n>nG n>nG UB UA t t t *) locked n=0 min-1 Supply Voltage Speed Alarm Signal nG (+) Power output Fan Customer (-) Power Isink UB +UBS US UB All voltages measured to ground. External load resistor Ra from UA to UBA required. Electrical connection t2 = Alarm signal suppression during start-up. * n < Speed limit nG by braking or locking.

8412 N/37 GMLV ≤ 0,4 n ≤ n G 2 2 8 n>n G 0 ≤ 28 10 <1 * 03 6

3412 N/37 GV ≤ 0,4 n ≤ n G 2 2 8 n>n G 0 ≤ 28 10 <1 * 04 0

  • After switching on UB Type VDC mA VDC mA VDC mA S min –1 Page Alarm signal data Attention: With these fan specials, deviations as regards temperature range, voltage range and power consumption are possible compared with standard fans. – Alarm signal for speed monitoring. – Signal output via open collector. – The fan emits a high continuous signal during trouble-free operation within the permissible voltage range. – Low signal when speed limit is not reached. – After elimination of fault, the fan returns to its setpoint speed; the alarm signal reverts to high. Available on request: – Alarm circuit TTL compatible. N G InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans Alarm output voltage UAL o w Condition: Condition: Isink = Alarm output voltage UA High Condition: Condition: Isource = Alarm operating- voltage UBA max. Max. permissible Sink current Isink Alarm delay- time t2 Condition: Speed limit nG Fan description

n>nG UB UA t t t UAHigh *) locked n=0 min-1 Supply Voltage Speed Alarm Signal nG (+) Power output Fan Customer (-) Power Isink UB +UBS US UB All voltages measured to ground External load resistor Ra from UA to UBA required. t2 = Alarm signal suppression during start-up * n < Speed limit nG by braking or locking 412 /39 ≤ 0 , 5 n>n G 2 2 8 n=n G 0 ≤ 28 10 <1 * 02 5

612 F/39 H ≤ 0 , 5 n>n G 2 2 8 n=n G 0 ≤ 28 10 <1 * 02 8

614 N /39 M ≤ 0 , 5 n>n G 2 2 8 n=n G 0 ≤ 28 10 <1 * 03 1

618 N /39 N ≤ 0 , 5 n>n G 2 2 8 n=n G 0 ≤ 28 10 <1 * 03 1

3412 N/39 H ≤ 0 , 5 n>n G 2 2 8 n=n G 0 ≤ 28 10 <1 * 04 0

3414 N/39 HH ≤ 0 , 5 n>n G 2 2 8 n=n G 0 ≤ 28 10 <1 * 04 0

4412 F/39 GL ≤ 0 , 5 n>n G 2 2 8 n=n G 0 ≤ 28 10 <1 * 04 4

4412 F/39 M ≤ 0 , 5 n>n G 2 2 8 n=n G 0 ≤ 28 10 <1 * 04 4

4414 F/39 ≤ 0 , 5 n>n G 2 2 8 n=n G 0 ≤ 28 10 <1 * 04 4

4414 FN/39 H ≤ 0,4 n > nG 2 ≤ 3 0 n=n G 0 ≤ 30 4 <1 * 0 44

  • after switching on UB Type VDC mA VDC mA VDC mA S min –1 Page Alarm signal data Attention: With these fan specials, deviations as regards temperature range, voltage range and power consumption are possible compared with standard fans. – Alarm signal for speed monitoring. – Signal output via open collector. – The fan emits a low continuous signal during trouble-free operation within the permissible voltage range. – High signal when speed limit is not reached. – After elimination of fault, the fan returns to its setpoint speed; the alarm signal reverts to low. N G Alarm output voltage UAL o w Condition: Condition: Isink = Alarm output voltage UA High Condition: Condition: Isource = Alarm operating- voltage UBA max. Max. permissible Sink current Isink Alarm delay- time t2 Condition: Speed limit nG Fan description

Vario-Pro® – ”Software instead of hardware“ – aptly describes the unique fan concept, equipped at the plant with tailor-made intelligence for cooling electronics. – Flexible configuration using software, allows quicker availability, sampling from the factory and the ability to supply customer-specific solutions in any quantity. 620 29

8400 N 36

8200 J 39

3400 N 40

3200 J 43

4400 FN 45

4100 N 49

4100 NH 50

4100 NH 7-8 51

5200 N 53

5100 N 55

7100 N 58

7200 N 59

– Speed setting via temperature, PWM or analogue control voltage. See page 120 (Speed setting). – Description of speed curve with up to 14 selectable interpolation points. Linear interpolation between the points. – Zero speed possible. – Recognition of sensor failure: In case of loss of sensor, the fan operates at programmable (fail-safe) speed. Alarm and tachometer functions – Optional alarm and/or tachometer function – Selectable alarm speed limit (with hysteresis) and alarm delay time – Latching of alarm signal – Delay only when starting or permanently active – ”High“ or ”Low“ output signal in case of alarm – Optional alarm if temperature sensor fails. – Optional alarm in case of excess temperature. Motor management – High control accuracy due to digital motor management – Higher operating efficiency due to optimum adaptation of motor hardware and software. InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans

Speed setting via temperature sensor – The control variable is a temperature sensor that is either integrated into the fan or con- nected to an additional control wire. (+) Power CustomerFan (+) Internal Ref. (-) 0V Ground NTC Input External temperature sensor Type T – Ext. NTC type LZ370 is required (not included in the standard scope of delivery). nmin ≈ 800 1/min nmax model-dependent Tmin ≈ 5° C T max ≤ 85 °C, model-dependent nmin ≈ 1/2 nmax Tmin ≈ 30 °C; Tmax = 50 °C Internal temperature sensor Type I – NTC integrated in fan hub. Standard speed-temperature curve for type T and type I Optionally available with user-selectable temperature-speed curve control 30°C 50°C nmax nmin TT nmax max nmin min (+) Power CustomerFan (+) Internal Ref. (-) 0V Ground NTC Input T I

with control voltage or PWM – The control variable is a PWM signal or analogue control voltage. – Standard PWM signal in 2 versions a) PWM frequency 2kHz (0-100%), Open collector input b) 4-Wire interface to Intel specification for 12 VDC fan, PWM frequency 20 kHz, incl. speed signal /2 CustomerFan (+) Power (-) 0V Ground Input CustomerFan (+) Power (-) 0V Ground Input (+) Power CustomerFan (+) Internal Ref. (-) 0V Ground Input Speed setting via PWM Type P Speed setting via control voltage Type A Standard curve P / A Optional – selectable curve P / A A5V (Optional) 10 V 05 1 0 PW M100%90 nmax nmin A5V (Optional) 10 V 100 % P WM nmax nmin A PWM InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans

Speed setting via multi-option control input – Customer can operate input either with PWM signal, analogue voltage, external temperature control module or resistor. – The control signal-speed characteristics of the fan differ from the standard curve of the A and P inputs (see p. 121). – To attain the maximum speed, the control wire must be switched against UB. – The control input is usually combined with an open collector tachometer (Type /2, see page 110). Speed setting via multi-option control input PWM U violet Temperature control module 50002-1-0174 50003-1-0174 Speed setting P W M1-1 0k H z Speed setting with potentiometer Full speed 100% PWM -> n=max approx. 10% PWM -> n=min < 10% PWM -> n=0 start up at > 14 % Speed setting 1V-1 0V

10 V -> n=max

approx. 1 V -> n=min < 1 V -> n=0 start up at > 1.4 V 33 K 4.7 K 10 K PWM

12 V 12 V Speed display

± 3.5% Tach output pulses per revolution GND I sink max. 10 mA Customer circuit Notes on various control possibilities and their applications Connection Fan Lin/PWM control input 0-10 VDC / PWM

1 Tach white

0-10 V / PWM violet Control input (Impedance 100 kΩ) Tach output: 3 pulses / revolution 0-10 V PWM Tach GND Line Connection Colour Assignment / function Line Connection Colour Assignment / function 1 + red Maximum ripple ± 3.5 % GND blue GND Line 1 red violet whiteblue

against environmental influences – Meeting special requirements for a broad range of applications. – Resistant to environmental influences, such as dust, splash water, humidity, spray water and salt spray fog. – Highly competent solutions for adapting fans to environmental conditions. The solutions that are available and in use can differ depending on size. We would be glad to devel- op solutions tailored to the demands of your application. Moisture protection A coating on the motor and printed circuit board protects against humidity and condensation. IP 54 protection The motor and circuit board are coated to pro- tect them against splash water and humidity. High protection classes up to IP 67 are available on request. Salt spray fog protection Salt spray fog is extremely demanding on the resistance of the product. ebm-papst makes use of technologies that protect fans and blow- ers from salt spray fog reliably and durably. Stainless steel bearings Special bearings made of stainless steel provide additional protection. HP IP54IP54/c219 SP InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans

ACmaxx / i-maxx technical information 126 ACmaxx / i-maxx overview 130 ACmaxx / i-maxx axial fans 131 DC axial fans InformationDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans

Progress made by ebm-papst The best example: The ACmaxx fans from ebm-papst, which, thanks to an ingenious yet simple improvement over conventional AC fans, provide substantial benefits. The aim in developing the new ACmaxx series was to raise the technology standard of the conventional AC fan significantly and, in the process, facil- itate the transition to the new technology by retaining the overall mount- ing dimensions. In short, to ensure the fans can be replaced 1:1 without any peripheral changes or changes to the voltage situation. ebm-papst offers two generations of ACmaxx products that meet different needs. Long service life The efficiency of ACmaxx and i-maxx motors is up to 75% higher than that of conventional AC fan variants. This not only saves energy, it also means less intrinsic heating in the motor. The reduced heating has a direct, positi- ve effect on the bearing system, which is why the fans have a service life that is up to 85% longer! This also lengthens the service and maintenance intervals significantly. The expense of replacement fans, and even more expensive downtimes, are kept to a manageable minimum. Technical information AC Standard Service Life 10000 20000 30000 40000 50000 60000 70000 80000 ACmaxx 70000 37500 88% increase in life time h 126 What ACmaxx and i-maxx have in common: Energy efficiency The drive concept is based on state-of-the-art GreenTech EC technology with outstanding motor efficiency. Compared to AC fans of the same size, ACmaxx energy consumption is up to 77% lower–for higher cooling capa- city! The energy balance alone means that the products pay for themsel- ves after only a few months. The savings over the entire service life, espe- cially in systems with multiple fans, is considerable. 0 231 [ EUR ] Years AC 4000 N AC 4300 ACi 4400 Independent of mains frequency and mains voltage The ACmaxx and i-maxx fans are prepared for direct connection to all AC voltages and frequencies. The speed, and thus important properties of the fan such as air flow and noise, are independent of the power frequency and do not change, even within the defined voltage range. Voltage fluctua- tions in the power system are automatically compensated for. AC ACmaxx i-maxx

  • Safety certifications: UL, CSA and VDE 0805 / EN60950. VDE 0700 / EN60335 on request.
  • Our fans have the CE mark of conformity.
  • EMC protection: > EN61000-4-4 Level 1 (1 kV or 2 kV)B > EN61000-4-2 Level 8 kV/15 kV or 4 kV/8 kV > EN61000-4-3 > EN61000-4-6 > EN61000-4-8 > EN55022 Class B Ambient influences AC fans are extremely common and are used in a wide variety of applica- tions. In control cabinet cooling, beer coolers, cooling cabinets, wood-bur- ning stoves, medical devices – all have different requirements for resi- stance to ambient influences. ACmaxx and i-maxx fans offer the same features for protection against moisture, splash water and rough ambient conditions. Particular design features of the i-maxx (ACi 4400): i-maxx is more compact! As large as existing AC fans – and not a bit larger. This is the most out- standing feature of the new i-maxx ACi 4400. Even in the hub area, the fan does not differ from typical 119x119x38 mm AC fans. Out with the AC, in with the i-maxx ACi 4400 – it's that simple. i-maxx is more efficient! ACmaxx saves energy, and the i-maxx generation saves even more. While an AC fan at 50 Hz can barely reach an overall efficiency of 5-6%, the ACmaxx makes it to approx. 20-25%. With the new i-maxx ACi 4400, a remarkable level of up to 30% is reached. This is the result of the optimi- sation of the entire package made up of drive, electronics, AC/DC conver- sion and aerodynamics. Thus the new i-maxx series boasts energy savings of almost 75% compared to the corresponding AC fan, thus providing signi- ficantly higher savings than the 40% level of the old AC 4300 generation. AC 4000 N [%] AC 4300 ACi 4400 Saving Use Saving Use Use i-maxx is quieter! The i-maxx ACi 4400 is quieter! Quieter than AC fans and quieter than the existing ACmaxx generation. The reason for this is the optimised aerody- namics and the drive, which is optimised for minimum structure-borne noise. Thus the fan is only half as loud at comparable air performance, and is up to 6 dB(A) quieter at some operating points. Speed independent of voltage and frequency For the i-maxx ACi 4400, the speed, and thus the air flow and operating noise, are independent of the supply voltage and power frequency. Versions are available for 115 VAC with a voltage range from 85 to 132 VAC and 230 VAC with a voltage range of 195 to 265 VAC. Voltage fluctua- tions and frequency differences in the power system are compensated for automatically. ACmaxx i-maxx DC axial fans InformationDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans

Particular design features of the ACmaxx: Prepared for all AC voltages These models have a very wide voltage range from 85 to 265 VAC – the global voltage range, so to speak. This enables the fan to be used around the world, opening up large savings potentials. In addition to reduced logi- stics effort and stock-keeping, worldwide availability is key. ACmaxx is compatible with every supply voltage–no switching needed. From 85 to 265 volts and mains frequencies of 50 and 60 hertz. Voltage fluctuations in the power system are automatically compensated for. Higher performance Unlike conventional AC technology, the state-of-the-art drive concept of this fan series is not linked to a fixed power frequency. This allows the motor speed to be increased over a wide range. Thus ACmaxx provides significantly higher air flow and significantly increased pressure. ACmaxx 120 mm 100 150 150 200 100 125 250 Standard AC fans 120 mm 0 30 60 90 120 150 0,50,40,30,20,1 m³/h Pa CFM [in H2O] You can find further information about these fan options in the "Specialised fans" chapter, starting on page 107. Or you can simply contact our application engineers to discuss your ideal ACmaxx or i-maxx fan. Higher flexibility The flexibility of ACmaxx is one-of-a-kind. With its intelligent features, ACmaxx can be individually adapted to the specific application: standby mode, overload mode at peak times or night reduction all the way to tem- perature-controlled quiet operation are all possible. From speed setting to alarm or speed signal outputs, ACmaxx offers optional interfaces with which you can quickly and easily implement operation monitoring.

DC axial fans InformationDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans Optional special versions Information on pictograms Speed signal The fan uses a separate wire to output information about its speed, and thus about the speed of the rotor. For technical details, please refer to page 110. On the pages of the catalogue and on the following overview pages, the pictograms illustrated below provide information about technically possi- ble special versions in the fan line presented. Please note that these special versions are not possible for all voltages and speeds, and not in all combinations. The special versions are designed for specific customers and projects and are not usually available off the shelf. Go / No-go alarm The fan uses a separate wire to output a static signal when it is stationary, thus providing information about whether or not the rotor is turning. For technical details, please refer to page 117. Alarm with limit speed If the speed drops below a certain level defined in the fan's electronics, the fan will emit a static signal, thus providing information about whether or not the rotor is turning. For technical details, please refer to page 114. External temperature sensor An NTC is connected to the fan via a separate wire and the fan changes its speed depending on the temperatu- re at the NTC. For technical details, please refer to page 120. Internal temperature sensor In this case, the NTC is integrated into the fan and the fan changes its speed depending on the temperature at the NTC. For technical details, please refer to page 120. PWM control input The speed of the fan can be changed via a pulse-width- modulated signal. This signal is applied to a specially provided wire. For technical details, please refer to page 121. Analogue control input The speed of the fan can be changed via a control volta- ge. This control voltage is applied to a specially provided wire. For technical details, please refer to page 121. Protection against moisture Protection for the fan's electronics against moisture and condensation. For technical details, please refer to page 123. IP 54 Protection of motor and PCB board against splashed water and humidity. For technical details, please refer to page 123. Protection against salt spray fog Protection of fan against the damaging effects of salt spray fog. For technical details, please refer to page 123. N G T I PWM A HP IP54IP54/c219 SP Multi-option control input The fan has a control input that the user can trigger eit- her using a PWM signal, an analogue signal or a resistor. For technical details, please refer to page 122.

/boxopen80 x 32 AC 8300 H 80 108 131 /boxopen92 x 38 AC 3200 J 144 109 132 /boxopen119 x 25 AC 4400 FN 205 110 133 /boxopen119 x 32 AC 4300 H 204 134 NEW /boxopen119 x 38 ACi 4400 100..180 135 1 7 2Øx5 1 A C 6100 N 350 136 1 7 2Øx5 1 A C 6200 N 350 137 NEW 98,5 Ø x 130 AC 100 NR 80..135 138 10 40 50 60 70 80 9020 30 100 400 500 600 700 800 900200 300 1000 2000 3000 ACmaxx / i-maxx Axial fans Series mm OPTIONAL P . PageIP >= IP54 Overview of air performance Overview of technically feasible designs Please note that these special versions are not possible for all voltages and speeds, and not in all combina- tions. The special versions are designed for specific customers and projects. As a rule they are not available off the shelf and are tied to minimum volumes. Please consult your customer support representative about the feasibility of your special variant. Multi-option control input Sleeve bearings Ball bearings – not yet available

  • available * Partially granted, partially in registration stage. Sintec sleeve bearings / ball bearingsVDE, UL, CSADimension Sensor Go / No-go alarmAlarm with limit speedExternal temperature sensorInternal temperature sensorPWM control inputAnalogue control inputHumidity protectionSalt spray fog protection

Highlights: – Universally suitable for all AC voltages between 85 and 265 V. – Fan speed not dependent on line frequency. – Significantly reduced power consumption compared to conventional AC fans. – Open loop speed control, sensor and alarm signal possible on request. General attributes: – Material: fibreglass-reinforced plastic. PA impeller, PBTP housing. – Fully integrated electronic commutation. – Protected against locking. – Connection via single strands AWG 22, TR 64. Bared and tin-plated. – Air exhaust over struts. Direction of rotation clockwise, seen on rotor. – Mass: 325 g. ACmaxx axial fans Series AC 8300 H 80 x 80 x 32 mm Nominal voltage Air flow Air flow Frequency Voltage range Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10at 40 °C at Tmax Curve 10 20 30 40 50 60 100 120 0 8 16 24 32 40 0,40,30,20,1 m³/h Pa CFM [in H2O] Nominal data Type m 3/h CFM V Hz VAC dB(A) Bel(A) / Watts RPM °C Hours Hours Speed variants available on request. + 0,3 52 2 + 0,5 HP A SP IP54IP54/c219 PWM I T N G max. 80 m3/h Sound pressure level Sound power level DC axial fans InformationDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans

– Universally suitable for all AC voltages between 85 and 265 V. – Fan speed independent of power frequency. – Significantly reduced power consumption compared to conventional AC fans. – Open loop speed control, sensor and alarm signal possible on request. – Rigid compression curve for high air flow at high back pressure. – Innovative impeller with winglets for low noise levels. General attributes: – Material: fibreglass-reinforced plastic. PA impeller, PBTP housing. – Fully integrated electronic commutation. Protected against locking. – Connection via single strands AWG 22, TR 64. Bared and tin-plated. – Air exhaust over struts. Direction of rotation clockwise, seen on rotor. – Mass: 325 g. ACmaxx axial fans Series AC 3200 J 92 x 92 x 38 mm Nominal voltage Air flow Air flow Frequency Voltage range Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10at 40 °C at Tmax CurveNominal data Type m 3/h CFM V Hz VAC dB(A) Bel(A) / Watts RPM °C Hours Hours Speed variants available on request. 20 40 160 200 120 100 120 0 1 53 04 56 07 5 0,70,60,50,40,30,20,1 m³/h Pa CFM [in H2O] 61.7+ 0.2 54.2 + 0.15 70.7 + 0.8 0.3 + 0.5 6+ 0.3 6+ 0.3 HP A SP IP54IP54/c219 PWM I T N G max. 144 m3/h Sound pressure level Sound power level

Service life L10at 40 °C at Tmax Curve 50 100 150 150 200 100 125 250 0 30 60 90 120 150 0,50,40,1 0,2 0,3 m³/h Pa CFM [in H2O] Highlights: – Universally suitable for all AC voltages between 85 and 265 V. – Fan speed independent of power frequency. – Significantly reduced power consumption compared to conventional AC fans. – Open loop speed control, sensor and alarm signal possible on request. – Rigid compression curve for high air flow at high back pressure. – Innovative impeller with winglets for low noise levels. General attributes: – Material: fibreglass-reinforced plastic. PA impeller, PBTP housing. – Fully integrated electronic commutation. Protected against locking. – Connection via single strands AWG 22, TR 64. Bared and tin-plated. – Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor. – Mass: 370 g.. ACmaxx axial fans Series AC 4400 FN 119 x 119 x 25 mm Nominal data Type m 3/h CFM V Hz VAC dB(A) Bel(A) / Watts RPM °C Hours Hours HP A PWM I T N G max. 205 m3/h Speed variants available on request. 57.957.9 25.425.4 + 0.5+ 0.5 + 0.15+ 0.15 Sound pressure level Sound power level DC axial fans InformationDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans

Service life L10at 40 °C at Tmax Curve 0 1 53 04 56 07 59 0 25 50 75 100 125 150 0,30,20,1 m³/h Pa CFM [in H2O] Highlights: – Universally suitable for all AC voltages between 85 and 265 V. – Fan speed independent of power frequency. – Significantly reduced power consumption compared to conventional AC fans. – Open loop speed control, sensor and alarm signal possible on request. General attributes: – Material: fibreglass-reinforced plastic. PA impeller, PBTP housing. – Fully integrated electronic commutation. – Protected against locking. – Connection via single strands AWG 22, TR 64. Bared and tin-plated. – Air exhaust over struts. Direction of rotation clockwise, seen on rotor. – Mass: 325 g. ACmaxx axial fans Series AC 4300 119 x 119 x 32 mm Nominal data Type m 3/h CFM V Hz VAC dB(A) Bel(A) / Watts RPM °C Hours Hours Speed variants available on request. 52,7 54O O + 0,6 Rotorüberstand max. 0,4 mm HP A SP IP54IP54/c219 PWM I T N G max. 204 m3/h Sound pressure level Sound power level Rotor protrudes

max. 180 m3/h i-maxx axial fans Series ACi 4400 119 x 119 x 38 mm m³/h Pa CFM [in H2O] 200 100 0,10 0,20 40 60 80 100 15050 Type m 3/h CFM VAC VAC dB(A) Bel(A) / Watts RPM °C Hours Hours Nominal data Nominal voltage Air flow Air flow Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10 (40 °C) ebm-papst Standard Service life L10 (Tmax) ebm-papst Standard Life expectancy L10Δ (40 °C) Curve Highlights: – Energy efficient AC fan with EC technology. – Conversion and drive electronics fully integrated. – Significant lower power consumption than existing AC fans. – Significantly lower noise than existing AC fans. – Significant higher service life than existing AC fans. – Fan speed not dependent on line frequency. General characteristics: – Material: fibreglass-reinforced plastic. Impeller PA, housing PBT. – Electronic locked rotor protection. – Electrical connection via 2 flat plugs 2,8 x 0,5 mm, flying leads optional. – Air exhaust over struts, direction of rotation clockwise, seen on rotor. – Mass: 250 g. HP SP IP54IP54/c219 +0,3 +0,3 +0,5 DC axial fans InformationDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans

Service life L10at 40 °CNominal data at Tmax Curve Type m 3/h CFM V Hz VAC dB(A) Bel(A) / Watts RPM °C Hours Hours Speed variants available on request. Highlights: – Universally suitable for all AC voltages between 85 and 265 V. – Fan speed independent of power frequency. – Significantly reduced power consumption compared to conventional AC fans. – Open loop speed control, sensor and alarm signal possible on request. General attributes: – Material: fibreglass-reinforced PA housing and impeller. – Fully integrated electronic commutation. – Protected against locking. – Connection via single strands AWG 22, TR 64. Bared and tin-plated. – Air exhaust over struts. Direction of rotation clockwise, seen on rotor. – Mass: 760 g. ACmaxx axial fans Series AC 6100 N 17 2øx5 1m m HP A SP IP54IP54/c219 PWM I T N G max. 350 m3/h 100 200 100 125 150 300 0 40 80 120 160 200 0,50,40,30,20,1 m³/h Pa CFM [in H2O] 50.8+0.2(32.5) Förderrichtung 3+0.2 83.3+0.6 27.5 Sound pressure level Sound power level

Service life L10at 40 °CNominal data at Tmax Curve Type m 3/h CFM V Hz VAC dB(A) Bel(A) / Watts RPM °C Hours Hours Highlights: – Universally suitable for all AC voltages between 85 and 265 V, 50-60 Hz. – Fan speed independent of power frequency. – Significantly reduced power consumption compared to conventional AC fans. – Open loop speed control, sensor and alarm signal possible on request. General attributes: – Material: aluminium housing, fibreglass-reinforced PA impeller. Housing with grounding lug for screw M4x8( T orx). – Fully integrated electronic commutation. – Protected against locking. – Connection via single strands AWG 22, TR 64. Bared and tin-plated. – Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor. – Mass: 900 g. ACmaxx axial fans Series AC 6200 N 17 2øx5 1m m Speed variants available on request. 30,5 83,3 +0,2 +0,6 7,5 7,5 0,80,8 1010 166 63,7 50 100 1500 100 200 100 300 0,40,30,20,1 m³/h Pa CFM [in H2O] HP A SP IP54IP54/c219 PWM I T N G max. 350 m3/h Sound pressure level Sound power level DC axial fans InformationDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans

Highlights: – Highest energy efficiency thanks to EC technology. – Protection class IP44 (IP45 possible depending on mounting position). – Speed-boost function via mains voltage switch. – Vibration-isolated motor. – Global voltage - one product applicable for all line voltages and frequencies between 85-265 VAC and 50/60 Hz. Fan speed independent from power frequency. General features: – Material: fibreglass-reinforced plastic, housing PP , impeller PA. – Electrical connection via 3-pole terminal block, max. 1.5 mm 2. – Protection class 2. – Approvals: VDE 60335-3-80. UL, CE, CSA on request. – Mass: 400 g. ACmaxx in-line duct fan Series AC 100 NR Ø 98,5 x 130 mm Nominal voltage Air flow Air flow Frequency Voltage range Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10at 40 °C at Tmax Curve 20 40 60 800 20 40 60 80 100 120 0,12 0,160,08 m³/h Pa CFM [in H2O] Nominal data HP IP44IP44/c219 max. 135 m3/h Optional: Max. speed at 135 m3/h (Curve 3). AC 100 NR 80 47,1 115/230 50-60 85...265 35 4,7 2,5 2 750 -10...+55 70 000 / 40 000 105 61,8 42 5,3 4,5 3 500 2 nominal boost Type m 3/h CFM V Hz VAC dB(A) Bel(A) / Watts RPM °C Hours Hours Sound pressure level Sound power level NEW

N L N L N L N L InformationDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans Highest energy efficiency: 0.03 - 0.045 W/m3/h free air (Specific fan power). Boost speed setting: 2 speed settings possible via boost function. Vibration isolation: Reduced transmission of vibrations from motor to housing. Intelligence: Speed settings and control outputs optional. Connection Scope of delivery Example 1: Continuous operation at nominal speed boost speed via light switch. Example 2: Nominal speed via light switch, separate boost switch. Example 3: Simple connection, nominal speed without switching. Example 4: Simple connection, boost speed without switching.

InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans

The renowned ebm-papst AC fans are used when DC voltage is not available. The AC range of fans is based on experience gained from decades of development activity, millions of units in series production and competence in innovation of a world-wide technological leader. A wide range of fans for AC operation is pre- sented in this catalogue. In addition to complete device fans, you will also find fans without external housing, providing a particularly eco- nomical advantage when the air duct can be integrated in the respective device. Variety of sizes AC fans are available in a variety of sizes with either air exhaust or air intake over struts. Silent running models with sleeve bearings or for extreme ambient conditions; fans with ball bearings are available with plug connection or external leads. Shaded-pole or capacitor motors Fan drives by shaded-pole or capacitor motors, most of which incorporate the world-famous ebm-papst external rotor principle: The fan blades are directly attached to the external rotor of the external rotor motor, thus combining both high performance and profitability. Flat built AC fans ebm-papst also has particularly flat built AC fans with internal rotor motor. Their advantage: quick start to full speed. A plastic impeller and the both smaller and lighter internal rotor motor lead to a lower moment of inertia. Bearings AC fans with sleeve bearings are powered by Class E insulated motors. Fans with ball bearings are equipped with Class B, E or F insulated motors. Protection class All ebm-papst fans conform to the requirements of IP 20. Fans conforming to IP 54 and special types of protection class are also available. AC voltage The line of AC fans for Euro voltage according to IEC 60038 (230 V+6% ,- 1 0% )i s basically also available for 115 V. Frequencies AC fans can be operated at frequencies of 50 Hz or 60 Hz. However, their technical data then changes accordingly. Capacitor Fans driven by capacitor external motors provide particularly high operating efficiency. Generally, the required operating capacitor is already integrated in the fan housing. Overloading Almost all AC fans are protected against over- loading (e.g. due to locked rotor) the drive motors are either impedance protected (marked “Impedance protected”, and/or “Z.P .”) or are equipped with a thermal switch (marked “Thermally protected” or “Th.P .”). The model designation of these fans ends with “S”. Technical information

Axial fans for AC operation Overview of technically feasible designs Overview of air performanceDimension Series Air flow Page mm m 3/h /boxopen80 x 38 8000 A 29...57 144 /boxopen80 x 38 8000 N 30...61 145 Ø 76 x 37 8000 TA 23...45 146 Ø 76 x 37 8000 TV 24...47 147 /boxopen92 x 25 3900 31...70 148 /boxopen92 x 38 3000 49...89 149 /boxopen119 x 25 9900 84...135 150 /boxopen119 x 38 4000 N 80...180 151 /boxopen119 x 38 4000 Z 100...180 152 Ø 113 x 37 4600 TA 138...147 153 Ø 108 x 37 4600 TZ 125...140 154 /boxopen127 x 38 5900 150...206 129 155 /boxopen135 x 38 5600 235...270 156 150 x 172 x 38 7000 330...390 157 Ø 150 x 55 7800 325...380 158 Ø 150 x 55 7400 390...445 159 Ø 172 x 51 6000 375...500 160 Ø 225 x 80 W**200 450...1030 161 /boxopen280 x 80 W2E 250 1865 162 10 40 50 60 70 80 9020 30 100 400 500 600 700 800 900200 300 1000 2000 3000 Axial fans Series mm OPTIONAL P .

8000 A 80 x 80 x 38 yes / – ••• 144

8000 N 80 x 80 x 38 yes / – ••• 145

8000 TA 76 Ø x 37 yes / – ••• 146

8000 TV 76 Ø x 37 yes / – ••• 147

3900 92 x 92 x 25 yes / – • – – 148 3000 92 x 92 x 38 yes / – ••• 149 9900 119 x 119 x 25 yes / – • – – 150

4000 N 119 x 119 x 38 yes / •• • • 151

4000 Z 119 x 119 x 38 yes / •• • • 152

4600 TA 113 Ø x 37 yes / – ••• 153

4600 TZ 108 Ø x 37 yes / – ••• 154

5900 127 x 127 x 38 yes / – • – – 155 5600 135 x 135 x 38 yes – ••• 156 7000 150 x 172 x 38 yes – – – – 157 7800 150 Ø x 55 yes • – – – 158 7400 150 Ø x 55 yes – – – – 159 6000 17 2¯x5 1 y e s – – – – 1 6 0 IP >= IP54

  • available – not yet available Sleeve bearings Ball bearings Information on pictograms On the pages of the catalogue and on the following overview pages, the pictograms illustrated below provide information about technically pos- sible special versions in the fan line presented. Please note that these special versions are not possible for all voltages and speeds, and not in all combinations. The special versions are designed for specific customers and projects and are not usually available off the shelf. HP IP54IP54/c219 SP InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans Sintec sleeve bearings/ball bearings PageVDE, UL, CSADimension Speed sensorHumidity protectionSalt spray fog protection Speed signal The fan uses a separate wire to output information about its speed, and thus about the speed of the rotor. For technical details, please refer to page 110. Protection against moisture Protection for the fan's electronics against moisture and condensation. For technical details, please refer to page 123. IP 54 Protection of motor and PCB board against splashed water and humidity. For technical details, please refer to page 123. Protection against salt spray fog Protection of fan against the damaging effects of salt spray fog. For technical details, please refer to page 123.

– AC fans with external rotor shaded-pole motor. Impedance protected against overloading. – Metal fan housing and impeller. – Air intake over struts. Direction of rotation clockwise, seen on rotor. – Electrical connection via 2 flat plugs 2.8 x 0.5 mm. – Fan housing with grounding lug and screw M 4 x 8 (TORX). – Mass: 490 g. – Optionally available with electrical connection via leads. – Optionally available with air exhaust over struts and clockwise direction of rotation. – Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. AC axial fans Series 8000 A 80 x 80 x 38 mm Nominal voltage Air flow Air flow Frequency Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10at 40 °CNominal data 0 5 10 15 20 25 30 10 20 30 40 50 2 5 3 6

50 Hz 60 Hz

0,150,100,05 m³/h Pa CFM [in H2O] at Tmax Curve Type m 3/h CFM V Hz dB(A) Bel(A) / Watts RPM °C Hours Hours 8880 A 29 17,1 230 50 26 4,1 / 9,0 1 750 -10...+80 60 000 / 25 000 1 8850 A 36 21,2 230 50 31 4,6 / 12,5 2 150 -10...+70 52 500 / 25 000 2 8550 A 48 28,3 230 50 36 5,0 / 12,0 2 700 -10...+70 52 500 / 25 000 3 8556 A 48 28,3 230 50 37 5,1 / 12,0 2 800 -40...+90 52 500 / 15 000 3 8830 A 34 20,0 115 60 29 4,3 / 8,0 1 950 -10...+80 62 500 / 25 000 4 8800 A 45 26,5 115 60 34 4,8 / 11,0 2 500 -10...+70 55 000 / 27 500 5 8500 A 57 33,5 115 60 41 5,5 / 11,0 3 200 -10...+75 55 000 / 25 000 6 8506 A 57 33,5 115 60 42 5,7 / 11,0 3 300 -40...+95 55 000 / 15 000 6 SP IP54IP54/c219 HP max. 57 m3/h Series 8000 A with reinforced flanges Sound pressure level Sound power level

Service life L10at 40 °CNominal data at Tmax Curve Type m 3/h CFM V Hz dB(A) Bel(A) / Watts RPM °C Hours Hours 8880 N 30 17,7 230 50 18 3,3 / 9,0 1 750 -10...+80 60 000 / 25 000 1 8850 N 37 21,8 230 50 24 3,9 / 12,5 2 150 -10...+70 52 500 / 25 000 2 8550 N 50 29,4 230 50 30 4,4 / 12,0 2 700 -10...+70 52 500 / 25 000 3 8556 N 50 29,4 230 50 31 4,5 / 12,0 2 800 -40...+90 52 500 / 15 000 3 8830 N 36 21,2 115 60 21 3,7 / 8,0 1 950 -10...+80 62 500 / 25 000 4 8800 N 47 27,7 115 60 28 4,3 / 11,0 2 500 -10...+70 55 000 / 27 500 5 8500 N 61 35,9 115 60 34 4,8 / 11,0 3 200 -10...+75 55 000 / 25 000 6 8506 N 61 35,9 115 60 35 5,0 / 11,0 3 300 -40...+95 55 000 / 15 000 6 – AC fans with external rotor shaded-pole motor. Impedance protected against overloading. – Metal fan housing and impeller. – Air exhaust over struts. Direction of rotation clockwise, seen on rotor. – Electrical connection via 2 leads. Bared and tin-plated. – Fan housing with grounding lug for screw M 4 x 8 (TORX). – Mass: 490 g. – Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. AC axial fans Series 8000 N 80 x 80 x 38 mm 10 20 30 40 50 2 5 0 5 10 15 20 25 30 0,200,150,100,05 m³/h Pa CFM [in H2O] SP IP54IP54/c219 HP max. 61 m3/h Fan type Lead wires

8830 N 8800 N 8550 N 8500 N 310 mm long AWG 18, TR 64

8880 N 310 mm long AWG 18, TR 64

8556 N 8506 N 310 mm long AWG 22

8850 N 440 mm long AWG 18, TR 64

InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans

– AC fans with external rotor shaded-pole motor. Impedance protected against overloading. – Impeller and mounting bracket of metal. – Air intake over mounting bracket. Direction of rotation clockwise, seen on rotor. – Electrical connection via 2 leads. Bared and tin-plated. – Mass: 370 g. – Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. AC axial fans Series 8000 TA 7 6Øx3 7m m Nominal voltage Air flow Air flow Frequency Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10at 40 °CNominal data 90° ø75,8 101 6 325 3,7 R43 37 0,3 0,15+ 0,2+ 10+ at Tmax Curve Type m 3/h CFM V Hz dB(A) / Watts RPM °C Hours Hours 8880 TA 23 13,5 230 50 15 / 9,0 1 650 -10...+80 60 000 / 25 000 – 8850 TA 30 17,7 230 50 19 / 12,0 2 100 -10...+70 52 500 / 25 000 – 8550 TA 38 22,4 230 50 25 / 12,0 2 650 -10...+70 52 500 / 25 000 – 8556 TA 38 22,4 230 50 26 / 12,0 2 750 -40...+90 52 500 / 15 000 – 8830 TA 26 15,3 115 60 18 / 8,0 1 850 -10...+80 62 500 / 25 000 – 8800 TA 34 20,0 115 60 23 / 11,0 2 450 -10...+70 55 000 / 27 500 – 8500 TA 45 26,5 115 60 30 / 11,0 3 150 -10...+75 55 000 / 25 000 – 8506 TA 45 26,5 115 60 31 / 11,0 3 250 -40...+95 55 000 / 15 000 – SP IP54IP54/c219 HP max. 45 m3/h The air flow and noise level of fans without external hou- sing depends on the installation conditions. The stated air flow and noise has been measured with an orifice 76.5 mm Ø at a distance of approx. 17 mm from the mounting bracket. Under exceptionally favourable mounting condi- tions, the air flow of fan series 8000 A is achievable. The noise in the optimal operating range can only be measured for these fans in a specific application. Fan type Lead wires

8880 TA 8850 TA 8830 TA 8800 TA 325 mm long AWG 18, TR 64

8550 TA 8500 TA 325 mm long AWG 18, TR 64

8556 TA 8506 TA 325 mm long AWG 18

Service life L10at 40 °CNominal data at Tmax Curve Type m 3/h CFM V Hz dB(A) / Watts RPM °C Hours Hours 8880 TV 24 14,1 230 50 15 / 9,0 1 650 -10...+80 60 000 / 25 000 – 8850 TV 31 18,2 230 50 20 / 12,0 2 100 -10...+70 52 500 / 25 000 – 8550 TV 40 23,5 230 50 27 / 12,0 2 650 -10...+70 52 500 / 25 000 – 8556 TV 40 23,5 230 50 28 / 12,0 2 750 -40...+90 52 500 / 15 000 – 8830 TV 27 15,9 115 60 18 / 8,0 1 850 -10...+80 62 500 / 25 000 – 8800 TV 36 21,2 115 60 24 / 11,0 2 450 -10...+70 55 000 / 27 500 – 8500 TV 47 27,7 115 60 32 / 11,0 3 150 -10...+75 55 000 / 25 000 – 8506 TV 47 27,7 115 60 33 / 11,0 3 250 -40...+95 55 000 / 15 000 – – AC fans with external rotor shaded-pole motor. Impedance protected against overloading. – Impeller and mounting bracket of metal. – Air exhaust over mounting bracket. Direction of rotation clockwise, seen on rotor. – Electrical connection via 2 leads. Bared and tin-plated. – Mass: 370 g. – Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. AC axial fans Series 8000 TV 7 6Øx3 7m m ø75,8 6 325 3 37 0,3 10+ 90° 101 3,7 0,15+ 0,2+ SP IP54IP54/c219 HP max. 47 m3/h The air flow and noise level of fans without external hou- sing depends on the installation conditions. The stated air flow and noise has been measured with an orifice 76.5 mm Ø at a distance of approx. 17 mm from the mounting bracket. Under exceptionally favourable mounting condi- tions, the air flow of fan series 8000 N is achievable. The noise in the optimal operating range can only be measured for these fans in a specific application. Fan type Lead wires

8880 TV 8850 TV 8830 TV 8800 TV 325 mm long AWG 18, TR 64

8550 TV 8500 TV 325 mm long AWG 18, TR 64

8556 TV 8506 TV 325 mm long AWG 18

InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans

– AC fans with internal rotor shaded-pole motor. Impedance protected against overloading. – Metal fan housing, impeller of mineral-reinforced plastic PA. – Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor. – Electrical connection via 2 flat plugs 2.8 x 0.5 mm. – Fan housing with grounding lug for screw M4. – Mass: 280 g. – Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. AC axial fans Series 3900 92 x 92 x 25 mm Nominal voltage Air flow Air flow Frequency Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10at 40 °CNominal data 0 1 02 03 0 10 20 30 40 50 111 114 0,200,150,100,05 m³/h Pa CFM [in H2O] at Tmax Curve Type m 3/h CFM V Hz dB(A) Bel(A) / Watts RPM °C Hours Hours 3950 L 31 18,2 230 50 24 3,8 / 6,0 1 550 -10...+80 70 000 / 27 500 1 3956 L 31 18,2 230 50 24 3,8 / 6,0 1 550 -40...+80 70 000 / 27 500 1 3950 M 45 26,5 230 50 29 4,2 / 6,0 2 150 -10...+80 70 000 / 27 500 2 3956 M 45 26,5 230 50 29 4,2 / 6,0 2 150 -40...+80 70 000 / 27 500 2 3950 59 34,7 230 50 35 4,7 / 11,0 2 650 -20...+80 55 000 / 20 000 3 3956 59 34,7 230 50 35 4,7 / 11,0 2 650 -40...+80 55 000 / 20 000 3 3900 L 39 23,0 115 60 27 4,0 / 5,0 1 850 -10...+80 70 000 / 27 500 4 3906 L 39 23,0 115 60 27 4,0 / 5,0 1 850 -40...+80 70 000 / 27 500 4 3900 M 53 31,2 115 60 34 4,6 / 5,0 2 600 -10...+80 70 000 / 27 500 5 3906 M 53 31,2 115 60 34 4,6 / 5,0 2 600 -40...+80 70 000 / 27 500 5 3900 70 41,2 115 60 40 5,1 / 9,0 3 150 -20...+80 60 000 / 22 500 6 3906 70 41,2 115 60 40 5,1 / 9,0 3 150 -40...+80 60 000 / 22 500 6 HP max. 70 m3/h Sound pressure level Sound power level

Service life L10at 40 °CNominal data at Tmax Type m 3/h CFM V Hz dB(A) Bel(A) / Watts RPM °C Hours Hours 3850 49 28,8 230 50 24 3,7 / 9,0 1 750 -10...+75 60 000 / 27 500 1 3856 54 31,8 230 50 26 3,9 / 9,0 1 950 -40...+90 60 000 / 20 000 2 3550 67 39,4 230 50 32 4,4 / 8,5 2 300 -10...+80 60 000 / 25 000 3 3556 67 39,4 230 50 33 4,5 / 8,5 2 400 -40...+90 60 000 / 20 000 3 3650 75 44,1 230 50 36 4,8 / 12,0 2 650 -10...+55 52 500 / 37 500 4 3656 75 44,1 230 50 37 4,9 / 12,0 2 700 -40...+75 52 500 / 22 500 4 3800 54 31,8 115 60 26 3,9 / 8,0 1 900 -10...+80 62 500 / 25 000 5 3806 60 35,3 115 60 29 4,2 / 8,0 2 150 -40...+95 62 500 / 17 500 6 3500 73 43,0 115 60 35 4,6 / 8,0 2 500 -10...+80 62 500 / 25 000 7 3506 73 43,0 115 60 36 4,7 / 8,0 2 600 -40...+95 62 500 / 17 500 7 3600 89 52,4 115 60 41 5,1 / 11,0 3 100 -10...+65 55 000 / 30 000 8 3606 89 52,4 115 60 42 5,2 / 11,0 3 200 -40...+75 55 000 / 25 000 8 – AC fans with external rotor shaded-pole motor. Impedance protected against overloading. – Metal fan housing and impeller. – Air exhaust over struts. Rotational direction CW looking at rotor. – Electrical connection via 2 leads. Bared and tin-plated. – Fan housing with grounding lug and screw M 4 x 8 (TORX). – Mass: 420 g. – Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. AC axial fans Series 3000 92 x 92 x 38 mm 01 0 2 0 30 40 10 20 30 40 50 0,2 0,250,150,100,05 m³/h Pa CFM [in H2O] Curve SP IP54IP54/c219 HP max. 89 m3/h Fan type Lead wires With sleeve bearings 310 mm long AWG 18, TR 64 With ball bearings 310 mm long AWG 18 Sound pressure level Sound power level InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans

– AC fans with external rotor shaded-pole motor. Protected against overloading by thermal cut-out. – Metal fan housing and impeller. – Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor. – Electrical connection via 2 flat plugs 2.8 x 0.5 mm. – Fan housing with grounding lug and screw M 4 x 8 (TORX). – Mass: 320 g. – Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. AC axial fans Series 9900 119 x 119 x 25 mm Nominal voltage Air flow Air flow Frequency Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10at 40 °CNominal data 0 1 53 04 56 0 20 40 60 80 100 0,150,100,05 m³/h Pa CFM [in H2O] at Tmax Curve Type m 3/h CFM V Hz dB(A) Bel(A) / Watts RPM °C Hours Hours 9956 L 84 49,4 230 50 29 4,4 / 9,5 1850 -40...+80 57 500 / 22 500 1 9956 M 104 61,2 230 50 35 4,7 / 10,0 2250 -40...+80 57 500 / 22 500 2 9950 117 68,9 230 50 37 5,0 / 14,0 2450 -20...+70 47 500 / 22 500 3 9956 117 68,9 230 50 37 5,0 / 14,0 2450 -40...+70 47 500 / 22 500 3 9906 L 100 58,9 115 60 34 4,6 / 8,0 2100 -40...+80 62 500 / 25 000 4 9906 M 111 65,3 115 60 37 5,0 / 8,0 2450 -40...+80 62 500 / 25 000 5 9900 135 79,5 115 60 42 5,4 / 12,0 2850 -20...+70 52 500 / 25 000 6 9906 135 79,5 115 60 42 5,4 / 12,0 2850 -40...+70 52 500 / 25 000 6 HP max. 135 m3/h Sound pressure level Sound power level

Service life L10at 40 °CNominal data at Tmax Curve Type m 3/h CFM V Hz dB(A) Bel(A) / Watts RPM °C Hours Hours 4890 N 80 47,1 230 50 25 4,0 / 11,0 1 550 -10...+70 55 000 / 27 500 1 4850 N* 100 58,9 230 50 32 4,4 / 10,0 1 800 -10...+70 57 500 / 27 500 2 4580 N* 123 72,4 230 50 41 5,2 / 18,0 2 350 -10...+55 40 000 / 27 500 3 4550 N* 145 85,3 230 50 44 5,4 / 16,5 2 550 -10...+55 42 500 / 30 000 4 4650 N 160 94,2 230 50 46 5,4 / 19,0 2 650 -10...+55 37 500 / 27 500 5 4656 N 160 94,2 230 50 47 5,5 / 19,0 2 650 -40...+85 37 500 / 15 000 5 4840 N 85 50,0 115 60 26 4,1 / 10,0 1 650 -10...+75 57 500 / 25 000 6 4800 N* 97 57,1 115 60 32 4,3 / 9,0 1 750 -10...+75 60 000 / 27 500 7 4530 N* 151 88,9 115 60 45 5,4 / 16,0 2 700 -10...+65 42 500 / 25 000 8 4500 N* 169 99,5 115 60 48 5,7 / 15,0 3 000 -10...+65 47 500 / 25 000 9 4600 N 180 105,9 115 60 50 5,7 / 18,0 3 100 -10...+60 40 000 / 25 000 10 4606 N 180 105,9 115 60 51 5,8 / 18,0 3 100 -40...+90 40 000 / 15 000 10 – AC fans with external rotor shaded-pole motor. Impedance protected against overloading. – Metal fan housing and impeller – Air intake over struts. Direction of rotation clockwise, seen on rotor. Types 4890 N and 4840 N air exhaust over struts. – Electrical connection via 2 flat plugs 3.0 x 0.5 mm. – Impeller with 3 or 5 blades, see note for fan type. – Optionally available: Models with reinforced flanges and single leads. – Fan housing with grounding lug for screw M 4 and UNC. – Mass: 550 g. – Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. AC axial fans Series 4000 N 119 x 119 x 38 mm 0 2 04 06 08 0 50 75 100 125 50 Hz 0,30,20,1 m³/h Pa CFM [in H2O] SP IP54IP54/c219 HP max. 180 m3/h 50 75 100 125 60 Hz 0 2 04 06 08 0 0,30,20,1 m³/h Pa CFM [in H2O] * Fan with 3 blades. Sound pressure level Sound power level InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans 230 V and 115 V versions are rated for both 50 Hz and 60 Hz operation. For 60 Hz data, please refer to the corresponding 115 V 60 Hz model, for 50 Hz data please refer to the corresponding 230 V 50 Hz model.

– AC fans with external rotor shaded-pole motor. Impedance protected against overloading. – Metal fan housing and impeller. – Air exhaust over struts. Direction of rotation clockwise, seen on rotor. – Electrical connection via 2 flat plugs 2.8 x 0.5 mm. – Optionally available: Models with reinforced flanges and single leads. – Fan housing with grounding lug and screw M 4 x 8 (TORX). – Mass: 540 g. – Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. AC axial fans Series 4000 Z 119 x 119 x 38 mm Nominal voltage Air flow Air flow Frequency Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10at 40 °CNominal data 0 2 04 06 08 0 1 0 0 25 50 75 100 125 1 4 0,20 0,250,150,100,05 m³/h Pa CFM [in H2O] at Tmax Curve Type m 3/h CFM V Hz dB(A) Bel(A) / Watts RPM °C Hours Hours 4850 Z 100 58,9 230 50 26 4,0 / 13,0 1 700 -10...+65 50 000 / 27 500 1 4856 Z 100 58,9 230 50 26 4,0 / 13,0 1 700 -40...+75 50 000 / 20 000 1 4580 Z 115 67,7 230 50 30 4,3 / 13,0 1 900 -10...+65 50 000 / 27 500 2 4586 Z 115 67,7 230 50 30 4,3 / 13,0 1 900 -40...+75 50 000 / 20 000 2 4650 Z 160 94,2 230 50 40 5,3 / 19,0 2 650 -10...+50 37 500 / 30 000 3 4656 Z 160 94,2 230 50 40 5,3 / 19,0 2 650 -40...+75 37 500 / 17 500 3 4800 Z 105 61,6 115 60 28 4,1 / 12,0 1 800 -10...+70 52 500 / 25 000 4 4806 Z 105 61,6 115 60 28 4,1 / 12,0 1 800 -40...+75 52 500 / 17 500 4 4530 Z 120 70,6 115 60 32 4,4 / 12,0 2 000 -10...+70 52 500 / 25 000 5 4536 Z 120 70,6 115 60 32 4,4 / 12,0 2 000 -40...+75 52 500 / 17 500 5 4600 Z 180 105,9 115 60 45 5,6 / 18,0 3 100 -10...+60 40 000 / 25 000 6 4606 Z 180 105,9 115 60 45 5,6 / 18,0 3 100 -40...+85 40 000 / 15 000 6 SP IP54IP54/c219 HP max. 180 m3/h Sound pressure level Sound power level

Service life L10at 40 °CNominal data at Tmax Type m 3/h CFM V Hz dB(A) / Watts RPM °C Hours Hours 4650 TA 138 81,2 230 50 41 / 19,0 2 550 -10...+45 37 500 / 32 500 – 4656 TA 138 81,2 230 50 42 / 19,0 2 550 -40...+75 37 500 / 17 500 – 4600 TA 147 86,5 115 60 43 / 18,0 2 900 -10...+50 40 000 / 32 500 – 4606 TA 147 86,5 115 60 44 / 18,0 2 900 -40...+80 40 000 / 17 500 – – AC fans with external rotor shaded-pole motor. Impedance protected against overloading. – Impeller and mounting bracket of metal. – Air intake over mounting bracket. Direction of rotation clockwise, seen on rotor. – Electrical connection via 2 leads. Bared and tin-plated. – Mass: 430 g. – Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. AC axial fans Series 4600 TA 11 3Øx3 7m m R4 3 16 37 0,5 90° 375 ø112,5 148,2 0,3+ 10+ 0,2+ 0,3+ 4,3 0,15+ Curve SP IP54IP54/c219 HP max. 147 m3/h The air flow and noise level of fans without external hou- sing depends on the installation conditions. The stated air flow and noise has been measured with an orifice 109 mm Ø at a distance of approx. 17 mm from the mounting bracket. Under exceptionally favourable mounting conditions, the air flow of fan series 4600 N is achievable. The noise in the optimal operating range can only be measured for these fans in a specific appli- cation. Fan type Lead wires

4650 TA 4600 TA AWG 22, TR 32

4656 TA 4606 TA AWG 18

InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans

– AC fans with external rotor shaded-pole motor. Impedance protected against overloading. – Impeller and mounting bracket of metal. – Air exhaust over mounting bracket. Direction of rotation clockwise, seen on rotor. – Electrical connection via 2 leads. Bared and tin-plated. – Mass: 430 g. – Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. AC axial fans Series 4600 TZ 10 8Øx3 7m m Nominal voltage Air flow Air flow Frequency Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10at 40 °CNominal data 337 0,5 375 ø108 0,3 10+ 0,3+R4 90° 148,2 0,2+ 4,3 0,15+ at Tmax Curve Type m 3/h CFM V Hz dB(A) / Watts RPM °C Hours Hours 4650 TZ 125 73,6 230 50 42 / 19,0 2 600 -10...+50 37 500 / 37 500 – 4656 TZ 125 73,6 230 50 42 / 19,0 2 600 -40...+65 37 500 / 20 000 – 4600 TZ 140 82,4 115 60 45 / 18,0 2 950 -10...+50 40 000 / 32 500 – 4606 TZ 140 82,4 115 60 45 / 18,0 2 950 -40...+75 40 000 / 17 500 – SP IP54IP54/c219 HP max. 140 m3/h The air flow and noise level of fans without external housing depends on the installation conditions. The sta- ted air flow and noise has been measured with an orifi- ce 109 mm Ø at a distance of approx. 17 mm from the mounting bracket. Under exceptionally favourable mounting conditions, the air flow of fan series 4000 Z is achievable. The noise in the optimal operating range can only be measured for these fans in a specific appli- cation. Fan type Lead wires

4650 TZ 4600 TZ AWG 22, TR 32

4656 TZ 4606 TZ AWG 18

Service life L10at 40 °CNominal data at Tmax Type m 3/h CFM V Hz dB(A) Bel(A) / Watts RPM °C Hours Hours 5988 150 88,3 230 50 37 4,9 / 13,0 2 250 -30...+55 35 000 / 20 000 1 5950 180 105,9 230 50 43 5,4 / 18,0 2 700 -20...+50 40 000 / 32 500 3 5958 180 105,9 230 50 44 5,5 / 18,0 2 750 -30...+60 40 000 / 25 000 3 5938 162 95,3 115 60 40 4,9 / 12,0 2 500 -30...+55 35 000 / 20 000 2 5900 206 121,2 115 60 46 5,7 / 17,0 3 050 -20...+55 42 500 / 30 000 4 5908 206 121,2 115 60 47 5,8 / 17,0 3 100 -30...+75 42 500 / 20 000 4 – AC fans with internal rotor shaded-pole motor. Impedance protected against overloading. – Metal fan housing and impeller of fibreglass-reinforced plastic PA. – Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor. – Electrical connection via 2 flat plugs 2.8 x 0.8 mm. – Fan housing with grounding lug and screw M4 x 6. – Mass: 570 g. – Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. AC axial fans Series 5900 127 x 127 x 38 mm 25 50 75 100 125 0,20 0,250,150,100,05 m³/h Pa CFM [in H2O] Curve HP max. 206 m3/h Sound pressure level Sound power level InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans

– AC fans with external rotor shaded-pole motor. Protected against overloading by thermal cut-out. – Metal fan housing and impeller. – Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor. – Electrical connection via 2 flat plugs 2.8 x 0.5 mm. – Fan housing with grounding lug and screw M 4 x 8 (TORX). – Mass: 800 g. – Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. AC axial fans Series 5600 135 x 135 x 38 mm Nominal voltage Air flow Air flow Frequency Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10at 40 °CNominal data 0 40 80 120 50 100 150 200 250 0,30,20,1 m³/h Pa CFM [in H2O] at Tmax Curve Type m 3/h CFM V Hz dB(A) Bel(A) / Watts RPM °C Hours Hours 5656 S 235 138,3 230 50 46 5,9 / 30,0 2 700 -35...+70 45 000 / 20 000 1 5606 S 270 158,9 115 60 50 6,2 / 26,0 3 100 -35...+80 47 500 / 20 000 2 SP IP54IP54/c219 HP max. 270 m3/h Sound pressure level Sound power level

Service life L10at 40 °CNominal data at Tmax Curve Type m 3/h CFM V Hz dB(A) Bel(A) / Watts RPM °C Hours Hours 7056 ES 320 188,3 230 50 51 6,4 / 27,0 2 800 -25...+55 60 000 / 32 000 1 7006 ES 380 223,6 115 60 56 6,8 / 28,0 3 350 -25...+65 55 000 / 18 000 2 – AC fans with external rotor capacitor motor. Protected against overloading by integrated thermal cut-out. – Metal fan housing and impeller. – Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor. – Electrical connection via 2 flat plugs 2.8 x 0.5 mm. – Fan housing with grounding lug and screw M4 x 6. – Mass: 900 g. – Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. AC axial fans Series 7000 150 x 172 x 38 mm 0 40 80 120 160 200 50 100 120 150 200 250 0,60,50,40,30,20,1 m³/h Pa CFM [in H2O] max. 380 m3/h Minimum ambient temperature -15 °C. Sound pressure level Sound power level InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans

– AC fans with external rotor shaded-pole motor. Protected against overloading by integrated thermal cut-out. – Metal fan housing and impeller. – Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor. – Electrical connection via 2 leads. Bared and tin-plated. – Fan housing with grounding lug and screw M4 x 6. – Mass: 1.1 kg. – Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. AC axial fans Series 7800 15 0Øx5 5m m Nominal voltage Air flow Air flow Frequency Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10at 40 °CNominal data 50 100 100 150 200 250 0 40 80 120 160 200 0,4 0,50,30,20,1 m³/h Pa CFM [in H2O] at Tmax Curve Type m 3/h CFM V Hz dB(A) Bel(A) / Watts RPM °C Hours Hours 7855 ES 325 191,3 230 50 49 6,0 / 45,0 2 800 -25...+50 60 000 / 47 000 1 7856 ES 325 191,3 230 50 49 6,0 / 45,0 2 800 -25...+70 60 000 / 23 000 1 7805 ES 380 223,7 115 60 53 6,4 / 38,0 3 250 -25...+70 60 000 / 47 000 2 7806 ES 380 223,7 115 60 53 6,4 / 38,0 3 250 -25...+90 60 000 / 18 000 2 max. 380 m3/h Minimum ambient temperature -15 °C, admissible for a short time at -30 °C; without condensation. Sound pressure level Sound power level

Service life L10at 40 °CNominal data at Tmax Type m 3/h CFM V Hz dB(A) Bel(A) / Watts RPM °C Hours Hours 7450 ES 380 223,6 230 50 60 6,8 / 47,0 2 700 -25...+50 63 000 / 50 000 1 7400 ES 425 250,1 115 60 62 6,9 / 46,0 3 050 -25...+70 50 000 / 24 000 2 – AC fans with external rotor shaded-pole motor. Protected against overloading by integrated thermal cut-out. – Metal fan housing and impeller. – Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor. – Electrical connection via 2 leads. Strand ends with brass lead tips. – Fan housing with grounding lug and screw M4 x 6. – Mass: 1.1 kg. – Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. AC axial fans Series 7400 15 0Øx5 5m m 100 200 300 400 100 0,40,30,20,1 m³/h Pa CFM [in H2O] Curve max. 425 m3/h Minimum ambient temperature -15 °C, admissible for a short time at -30 °C; without condensation. Sound pressure level Sound power level InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans

– AC fans with external rotor capacitor motor. Protected against overloading by integrated thermal cut-out. – Metal fan housing and impeller. – Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor. – Electrical connection via 2 flat plugs 2.8 x 0.5 mm. – Fan housing with grounding lug and screw M4 x 6. – Mass: 1.0 kg. – Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. AC axial fans Series 6000 17 2Øx5 1m m 0 40 80 120 160 200 240 100 200 300 400 120 m³/h Pa CFM [in H2O] max. 500 m3/h Nominal voltage Air flow Air flow Frequency Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10at 40 °CNominal data at Tmax Curve Minimum ambient temperature -15 °C, admissible for a short time at -30 °C; without condensation. Type m 3/h CFM V Hz dB(A) Bel(A) / Watts RPM °C Hours Hours 6058 ES 375 220,7 230 50 55 5,9 / 24,0 2 800 -25...+70 62 000 / 31 000 1 6078 ES 420 247,2 230 50 54 6,3 / 26,0 2 800 -25...+60 62 000 / 39 000 2 6008 ES 440 259,0 115 60 60 6,4 / 26,0 3 300 -25...+70 57 000 / 28 000 3 6028 ES 500 284,3 115 60 58 6,7 / 29,0 3 300 -25...+75 57 000 / 22 000 4 Sound pressure level Sound power level

– External-rotor single-phase motor.* / External rotor shaded-pole motor. – Motor protection: TOP wired internally. – Material: Wall ring die-cast aluminium, seven blades of sheet steel. Blades and rotor coated in black. – Direction of air flow “V”, air exhaust over struts. Direction of rotation: counter-clockwise, seen on rotor. – Electrical connection: Terminal strip (operating capacitor connected). – Continuous operation (S1). – Insulation class: “F” – Mass: 2 kg. – Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. AC axial fans W 200 225 x 225 x 80 mm Nominal voltage Air flow Air flow Frequency Sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10at 40 °CNominal data at Tmax Curve Type m 3/h CFM V Hz dB(A) Bel(A) / Watts RPM °C Hours Hours W2E200-HK86-01* 1030 606,2 115 60 61 6,7 / 80,0 2800 -25...+65 60 000 / 58 000 2 W2E200-HK38-01* 880 517,9 230 50 58 6,6 / 64,0 2550 -25...+60 63 000 / 60 000 2 W4S200-HK04-01** 450 264,9 230 50 40 4,7 / 30,0 1370 -25...+70 85 000 / 80 000 1 max. 1030 m3/h 200 400 600 800 0 100 300 400 200 500 100

60 Hz50 Hz

0,40,30,20,1 m³/h Pa CFM [in H2O] 50 Hz 200100 300 400 100 150 200 250 0,200,150,10,05 m³/h Pa CFM [in H2O] InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans Sound pressure level Sound power level

– External-rotor single-phase motor. – Motor protection: TOP wired internally. – Material: Wall ring die-cast aluminium, seven blades of sheet steel. Blades and rotor coated in black. – Direction of air flow “V”, air exhaust over struts. Direction of rotation: counter-clockwise, seen on rotor. – Electrical connection: Terminal strips (operating capacitor connected). – Continuous operation (S1). – Insulation class: “F” – Mass: 2 kg. – Please note our new ACmaxx series. With identical mounting dimensions and voltages, this series achieves higher energy efficiency. AC axial fans W2E 250 280 x 280 x 80 mm Nominal voltage Air flow Air flow Frequency Sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10at 40 °CNominal data at Tmax Curve Type m 3/h CFM V Hz dB(A) Bel(A) / Watts RPM °C Hours Hours W2E 250-HL06-01 1865 1077,1 230 50 66 7,2 / 127,0 2 550 -25...+60 63 000 / 70 000 3 max. 1865 m3/h 400 800 1200 1600 0 200 0,4 0,50,30,20,1 400 800 600 100 120 140 m³/h Pa CFM [in H2O] Sound pressure level Sound power level

AC centrifugal fan overview 165 AC centrifugal fans 166 AC centrifugal fans InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans

The renowned ebm-papst AC fans are used when DC voltage is not available. The AC range of fans is based on experience gained from decades of development activity, millions of units in series production and competence in innovation of a world-wide technological leader. A wide range of fans for AC operation is pre- sented in this catalogue. In addition to complete device fans, you will also find fans without external housing, providing a particularly eco- nomical advantage when the air duct can be integrated in the respective device. Variety of sizes AC fans are available in a variety of sizes with either air exhaust or air intake over struts. Silent running models with sleeve bearings or for extreme ambient conditions; fans with ball bearings are available with plug connection or external leads. Shaded-pole or capacitor motors Fan drives by shaded-pole or capacitor motors, most of which incorporate the world-famous ebm-papst external rotor principle: The fan blades are directly attached to the external rotor of the external rotor motor, thus combining both high performance and profitability. Flat built AC fans ebm-papst also has particularly flat built AC fans with internal rotor motor. Their advantage: quick start to full speed. A plastic impeller and the both smaller and lighter internal rotor motor lead to a lower moment of inertia. Bearings AC fans with sleeve bearings are powered by Class E insulated motors. Fans with ball bearings are equipped with Class B, E or F insulated motors. Protection class All ebm-papst fans conform to the requirements of IP 20. Fans conforming to IP 54 and special types of protection class are also available. AC voltage The line of AC fans for Euro voltage according to IEC 60038 (230 V+6% ,- 1 0% )i s basically also available for 115 V. Frequencies AC fans can be operated at frequencies of 50 Hz or 60 Hz. However, their technical data then change accordingly. Capacitor Fans driven by capacitor external motors provide particularly high operating efficiency. Generally, the required operating capacitor is already integrated in the fan housing. Overloading Almost all AC fans are protected against over- loading (e.g. due to locked rotor) the drive motors are either impedance protected (marked “Impedance protected”, and/or “Z.P .”) or are equipped with a thermal switch (marked “Thermally protected” or “Th.P .”). The model designation of these fans ends with “S”. Technical information

Centrifugal fans for AC operation Overview of air prformanceDimension Series Air flow Page mm m 3/h /boxopen121 x 37 RL 90 40...42 166 /boxopen135 x 38 RG 90 47...54 167 /boxopen180 x 40 RG 125 86...94 168 /boxopen220 x 56 RG 160 202...223 169 Ø 138 x 40 RER 125 104...115 170 Ø 176 x 54 RER 160 234...274 171 10 40 50 60 70 80 9020 30 100 400 500 600 700 800 900200 300 1000 2000 3000 Centrifugal fans Series mm OPTIONAL P . RL 90 121 x 121 x 37 yes / – ••• 166 RG 90 135 x 135 x 38 yes / – ••• 167 RG 125 180 x 180 x 40 yes – ••• 168 RG 160 220 x 220 x 56 yes – ••• 169 RER 125 138 Ø x 40 yes – ••• 170 RER 160 176 Ø x 54 yes – ••• 171 InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans Information on pictograms On the pages of the catalogue and on the following overview pages, the pictograms illustrated below provide information about technically pos- sible special versions in the fan line presented. Please note that these special versions are not possible for all voltages and speeds, and not in all combinations. The special versions are designed for specific customers and projects and are not usually available off the shelf. HP IP54IP54/c219 SP Speed signal The fan uses a separate wire to output information about its speed, and thus about the speed of the rotor. For technical details, please refer to page 110. Protection against moisture Protection for the fan's electronics against moisture and condensation. For technical details, please refer to page 123. IP 54 Protection of motor and PCB board against splashed water and humidity. For technical details, please refer to page 123. Protection against salt spray fog Protection of fan against the damaging effects of salt spray fog. For technical details, please refer to page 123. Overview of technically feasible designs IP >= IP54

  • availabe – not yet available Sleeve bearings Ball bearings Sintec sleeve bearings/ball bearings PageVDE, UL, CSADimension Speed sensorHumidity protectionSalt spray fog protection

Service life L10at 40 °CNominal data at Tmax Curve Type m 3/h CFM V Hz Bel(A) / Watts RPM °C Hours Hours RL 90-18/50 40 23,5 230 50 5,6 / 20,0 2 450 -10...+50 37 500 / 30 000 1 RL 90-18/56 40 23,5 230 50 5,6 / 20,0 2 450 -30...+70 37 500 / 20 000 1 RL 90-18/00 42 24,7 115 60 6,0 / 19,5 2 550 -10...+60 37 500 / 25 000 2 RL 90-18/06 42 24,7 115 60 6,0 / 19,5 2 550 -30...+85 37 500 / 15 000 2 SP IP54IP54/c219 HP max. 42 m3/h – AC centrifugal fan with external rotor shaded-pole motor. Impedance protected against overloading. – Spiral housing and impeller of fibreglass-reinforced plastic. Housing base of galvanised steel plate. Housing base with flat plug 6.3 x 0.8 mm for protective earth. – Direction of air flow radial, through housing port. Direction of rotation clockwise, seen on rotor. – Electrical connection via 2 leads. Bared and tin-plated. – Mass: 680 g. AC centrifugal fans Series RL 90 121 x 121 x 37 mm 0 4 8 12 16 20 5 10 15 20 100 0,40,30,20,1 m³/h Pa CFM [in H2O] Fan type Lead wires RL 90-18/50 RL 90-18/00 AWG 18, TR 32 RL 90-18/56 RL 90-18/06 AWG 22

Service life L10at 40 °CNominal data at Tmax Curve Type m 3/h 10 -3 m3/s V DC Hz dB(A) Bel / Watts RPM °C Hours HoursType m 3/h CFM V Hz Bel(A) / Watts RPM °C Hours Hours RG 90-18/50 54 31,8 230 50 5,8 / 22,0 2 200 -30...+60 35 000 / 20 000 1 RG 90-18/56 54 31,8 230 50 5,8 / 22,0 2 200 -30...+60 35 000 / 20 000 1 RG 90-18/00 47 27,7 115 60 6,2 / 22,0 1 900 -30...+65 35 000 / 20 000 2 RG 90-18/06 47 27,7 115 60 6,2 / 22,0 1 900 -30...+65 35 000 / 20 000 2 SP IP54IP54/c219 HP max. 54 m3/h – AC centrifugal fan with external rotor shaded-pole motor. Impedance protected against overloading. – Spiral housing and impeller of fibreglass-reinforced plastic. Housing base of galvanised steel plate. – Direction of air flow radial, through housing port. Direction of rotation clockwise, seen on rotor. – Electrical connection via 2 leads AWG 22. Bared and tin-plated. – Mass: 560 g. AC centrifugal fans Series RG 90 135 x 135 x 38 mm 0 5 10 15 20 25 30 10 20 30 40 50 0,40,30,20,1 m³/h Pa CFM [in H2O] InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans

Type m 3/h CFM V Hz Bel(A) / Watts RPM °C Hours Hours RG 125-19/56 86 50,6 230 50 5,8 / 20,0 2 550 -30...+70 37 500 / 20 000 1 RG 125-19/06 94 55,3 115 60 6,0 / 19,0 2 750 -30...+80 40 000 / 15 000 2 SP IP54IP54/c219 HP max. 94 m3/h Nominal voltage Air flow Air flow Frequency Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10at 40 °CNominal data at Tmax Curve – AC centrifugal fan with external rotor shaded-pole motor. Impedance protected against overloading. – Spiral housing and impeller of fibreglass-reinforced plastic. Housing base of galvanised steel plate. – Direction of air flow radial, through housing port. Direction of rotation clockwise, seen on rotor. – Electrical connection via 2 leads AWG 22. Bared and tin-plated. – Mass: 850 g. AC centrifugal fans Series RG 125 180 x 180 x 40 mm 0 1 02 03 04 05 0 20 40 100 60 80 0,60,40,2 m³/h Pa CFM [in H2O]

Service life L10at 40 °CNominal data at Tmax Curve Typ m 3/h 10 -3 m3/s V DC Hz dB(A) Bel / Watts RPM °C Hours HoursType m 3/h CFM V Hz Bel(A) / Watts RPM °C Hours Hours RG 160-28/56S 202 118,9 230 50 6,6 / 47,0 2 750 -30...+70 30 000 / 15 000 1 RG 160-28/06S 223 131,3 115 60 6,9 / 50,0 3 050 -30...+80 27 500 / 12 500 2 SP IP54IP54/c219 HP max. 223 m3/h – AC centrifugal fan with external rotor shaded-pole motor. Thermal contactor as protection against thermal overloading. – Spiral housing and impeller of fibreglass-reinforced plastic. Housing base of galvanised steel plate. – Direction of air flow radial, through housing port. Direction of rotation counter-clockwise, seen on rotor. – Electrical connection via leads AWG 18. Bared and tin-plated. – Mass: 1.7 kg. AC centrifugal fans Series RG 160 220 x 220 x 56 mm 0 2 04 06 08 0 1 0 0 1 2 0 50 100 100 150 200 1,20,80,4 m³/h Pa CFM [in H2O] InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans

max. 115 m3/h Nominal voltage Air flow Air flow Frequency Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L10at 40 °CNominal data at Tmax Curve Type m 3/h CFM V Hz Bel(A) / Watts RPM °C Hours Hours RER 125-19/56 104 61,2 230 50 6,2 / 19,0 2 600 -30...+60 37 500 / 22 500 1 RER 125-19/06 115 67,7 115 60 6,5 / 18,0 2 850 -30...+70 40 000 / 20 000 2 – AC centrifugal fan with external rotor shaded-pole motor. Impedance protected against overloading. – Impeller of fibreglass-reinforced plastic, with steel plate reinforced. – Direction of air flow radial. Direction of rotation clockwise, seen on rotor. – Electrical connection via leads AWG 22. Bared and tin-plated. – Mass: 500 g. AC centrifugal fans Series RER 125 13 8Øx4 0m m 0 1 02 03 04 05 06 0 20 40 60 80 100 0,30,20,1 m³/h Pa CFM [in H2O] The air flow and noise level of fans without external housing depend on the installation conditions. The stated air flow and noise levels have been measured under the following conditions: Centrifugal fan mounted on a base plate 220 x 220 mm. Cover plate 220 x 220 mm with an air inlet of Ø 86 mm, concentric to the impeller.

Service life L10at 40 °CNominal data at Tmax Curve Typ m 3/h 10 -3 m3/s V DC Hz dB(A) Bel / Watts RPM °C Hours HoursType m 3/h CFM V Hz Bel(A) / Watts RPM °C Hours Hours RER 160-28/56S 234 137,7 230 50 6,6 / 45,0 2 800 -30...+60 30 000 / 20 000 1 RER 160-28/06S 274 161,3 115 60 6,8 / 46,0 3 250 -30...+70 30 000 / 15 000 2 SP IP54IP54/c219 HP max. 274 m3/h – AC centrifugal fan with external rotor shaded-pole motor. Impedance protected against overloading. – Impeller of fibreglass-reinforced plastic, with steel plate reinforced. – Direction of air flow radial. Direction of rotation counter-clockwise, seen on rotor. – Electrical connection via leads AWG 18. Bared and tin-plated. – Mass: 1.0 kg. AC centrifugal fans Series RER 160 17 6Øx5 4m m 0 30 60 90 120 150 50 100 150 200 250 0,80,60,40,2 m³/h Pa CFM [in H2O] The air flow and noise level of fans without external housing depend on the installation conditions. The stated air flow and noise levels have been measured under the following conditions: Centrifugal fan mounted on a base plate 260 x 260 mm. Cover plate 260 x 260 mm with an air inlet of Ø 100 mm, concentric to the impeller. InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans

Fan filter guard grilles 180 Inlet nozzles 182 Connection cables / Accessories 183 Everything that you need for your fan. ebm-papst provides an extensive range of accessories for optimum fan operation: From temperature sensing for speed- controlled fans to finger guards of all types, switched-mode power supply, connecting cable, filter, screens, spacers and assembly parts. In addition to the accesso- ries and assembly parts listed in this catalogue, ebm-papst also supplies numerous special parts for fan operation. The sales experts at ebm-papst will be happy to assist you in your enqui- ries concerning fan assembly and application. From selection to accessories: Insist on the efficient and reliable service provided by ebm-papst. InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans

– Guard grille acc. to DIN EN ISO 13857 (previously EN 294), made of galvanised or nickel- plated and passivated steel wire for device fans. – Additional guard grilles that do not conform to DIN EN ISO 13857 are available on request. – Our guard grilles are specially designed for use with ebm-papst fans. Their design ensures maximum safety with minimum effect on the operating noise level. Note that when using guard grilles from other manufacturers, compliance with safety-related distances will not always be present. Guard grilles LZ29-1 Fan size 40 x 40 4,2+1 +0,3 +0,54,2 ±0,5 LZ28-1 Fan size 60 x 60 82,5 82,5 4,3 0,2+ _192 40 1+ 4,7 0,3+ LZ23-1 Fan size 92 x 92 4,7 0,3+ 71,5 71,5 78,2 4,3 0,2+ 0,5± 40 1+ LZ32-4 Fan size 80 x 80 119 51,5+1 4,7 +0,3 104,8 104,8 4,3 0,2+ LZ30-4 Fan size 119 x 119 4,8 1,8 4,5 LZ31 Fan size 50 x 50

400 LZ29-1

500 LZ31

600 LZ28-1

3000 LZ23-1

8000 LZ32-4 / LZ22-2

9000 LZ30-4 / LZ 30

4000 LZ30-4 / LZ 30

5100 LZ25

5600 LZ25

5200 LZ35

5300 LZ53

5900 LZ35

7000 LZ36

6300 LZ37

6400 LZ38

4,3 5 +0,2 +1 ±0,25 115 153,5 LZ30 Fan size 119 x 119 136,5 6,45 1+ 0,2++ 124,5 0,2+ LZ53 Fan size 140 x 140 4,3 2,5+0,2 +0,3 105,5 +0,5 LZ22-2 Fan size 80 x 80 LZ25 Fan size 135 x 135 LZ35 Fan size 127 x 127 LZ36 Fan size 150 x 172 LZ37 Fan size 17 2Øx5 1 LZ38 Fan size 17 2Øx5 1 LZ39 Fan size 17 2Øx5 1 199,5 186,5 )( 8,45 27,5 0,5 10,2 148,5 LZ22 Fan size 200 x 51 InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans

51,5 4,7 4,3 119 104,8 +1 +1 +0,3 +0,2 104,8 LZ30-9 Fan size 119 X 119 – Guard grille acc. to DIN EN ISO 13857 (previously EN 294), made of galvanised or nickel- plated and passivated steel wire for device fans. – The guard grilles shown on this page are designed specially for ACmaxx series fans and are installed on the outlet side. ACmaxx guard grilles AC 8300 LZ32-4 Intake side s.P .174 AC 8300 H LZ32-7 Outlet side AC 3200 J LZ23-1 Intake side s.P .174 AC 3200 J LZ23-6 Outlet side AC 4400 FN LZ30-4 Intake side s.P .174 AC 4400 FN LZ30-9 Outlet side AC 4300 LZ30-4 Intake side s.P .174 AC 4300 LZ30-9 Outlet side ACi 4400 LZ30 Intake side s.P .175 ACi 4400 LZ30 Outlet side s.P .175 Fan series Guard grilles AC 6200 N LZ37 Intake side s.P .175 AC 6200 N LZ37-2 Outlet side AC 6100 N LZ37 Intake side s.P .175 AC 6100 N * Outlet side Fan series Guard grilles *Outlet-side grilles on request 51,5 162 Ø158,9 4,3 6 2,5 ±0,2 +0,5 ±0,3 ±0,5 LZ37-2 Fan size 17 2ØX5 1 61,1 0,25+ 79,8 0,5 4,5 0,1+ 12,9 6,3 0,3 0,3 71,5 0,2+ LZ32-7 Fan size 80 x 80 63,7 4,5 0,1+ 82,5 0,2+ 7,3 LZ23-6 Fan size 92 x 92

– Steel wire, plastic-coated, silver-metallic gloss. Guard grilles 78128-2-4039 Size 200 09418-2-4039 Size 250 W1G 200 78128-2-4039 W1G 250 09418-2-4039 W2E 200 78128-2-4039 Fan series Guard grilles W4S 200 78128-2-4039 W2E 250 09418-2-4039 Fan series Guard grilles InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans

– Guard grille acc. to DIN EN ISO 13857 (previously EN 294), made of fibreglass-reinforced plastic. – Plastic grilles must not be used for the following models:

8200 JH3 / JH4

3200 JH3 / JH4

4100 NH5 - NH8

Suitable for bore diameters 4.3 - 4.7 only. Guard grilles LZ30-5 A2 119 -0,5 105±0,2 6,5 50 LZ30-6 A4 119 -0,5 105±0,2 6,5 50 LZ33-1 A2 127 -0,5 113,5±0,2 6,5 50 LZ33-2 A4 127 -0,5 113,5±0,2 6,5 50 Guard grilles Mounting B C D E LZ32-2 A1 80 -0,5 71,5±0,2 7,0 34 LZ32-3 A3 80 -0,5 71,5±0,2 7,0 34 LZ23-2 A1 92,5 -0,5 82,5±0,2 6,5 46 LZ23-3 A3 92,5 -0,5 82,5±0,2 6,5 46 Guard grilles Mounting B C D E LZ32P Fan size 80 x 80 LZ32-2 / LZ32-3 Size 80 x 80 LZ23-2 / LZ23-3 Size 92 x 92 LZ30-5 / LZ30-6 Size 119 x 119 LZ33-1 / LZ33-2 Size 127 x 127 LZ30P Fan size 119 x 119 Screw connection Barbed inserts

– PA plastic 6, fibreglass-reinforced Guard grilles for compact centrifugal modules RG 190 LZ46 133 9,0 RG 220 LZ47 166 8,7 RG 225 LZ48 158 8,7 Fan series Guard grilles a b InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans

– Filter guard grilles consist of a mounting plate, filter and screen. – Screen LZ40 N made of black, fibreglass-reinforced plastic with inserted wire netting LZ60. – Filter LZ60 made of Nirosta stainless steel wire netting. – Mounting plate LZ40-1 for installation. Fan filter guard grilles LZ40N Screen LZ40-1 Bracket LZ60 Filter 4400 F 4400 FN 4300 4300 N 4400 4200 4100 N Fan series DC AC 4300 9900 4000 N 4000 Z Fan series AC

B D D FF92 / FF 119 – Filter guard grille suitable for attachment to axial fan series of size 60 mm, 80 mm, 92 mm, 119 mm, ø 172 mm. All filter units fit directly onto the existing installation holes of the fans. – Filter guard grille consisting of 3 parts: outer grille barrier, inner fastening plate and repla- ceable filter mat. – Grille barrier made of moulded polycarbonate (PC), with matted surface. – Fast and easy exchange of filter mat via a quick release on the grille barrier. – Fastening plate made of wire netting, with black powder coating. – Filter mat can be replaced while the fan is running, protection provided by welded wire netting. – Filter mat made of white, synthetically bonded fibres. Fan filter guard grilles Filter capacity A fan filter guard filters out up to 75% of dust particles up to a size of 5-10 microns and withstands temperatures of up to 100°C. Flame retardant in accordance with DIN 53438, grade F1. For installed, clean filters, an air flow reduction of 20 – 30% can be assumed. AC B D D FF60 / FF80 Fan size: 60 x 60 mm 8 0x8 0m m * Replacement filters only in packs of 5. Fan size: 92 x 92 mm 119 x 119 mm A C B D FF 172 Fan size: ¯172 mm FF60 60 x 60 mm 65 65 13,5 50,0 RF 60 FF80 80 x 80 mm 85 85 14,0 71,5 RF 80 FF92 92 x 92 mm 125 105 17,5 82,5 RF 92 FF119 119 x 119 mm 162 136 18,5 104,5 RF 119 FF172 ø 172 mm 226 190 19,5 162,0 RF 172 Protection filter Fan size A B C D Replacement filter* InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans

– Material: Sheet steel, galvanised Inlet nozzles for centrifugal fans Fan Vers. k m o q r 1 s t u No.: RET 97 (S) 1 116,0 80,0 10,0 0,80 10,0 108,0 3x4,5 – LZ 1000-097 RER 120 (P) 1 146,0 94,4 18,0 0,80 16,0 134,0 4x4,5 126,0 LZ 1000-120 RER 133 (P) 1 129,0 87,0 13,0 1,00 8,0 118,0 4x4,5 103,0 LZ 1000-133 RER 175 / 190 (P) 1 170,0 125,5 14,0 1,25 10,0 158,0 4x4,5 146,0 LZ 1000-175 RER 220 (P) 2 252,0 155,0 21,0 0,80 22,0 – – 199,0 LZ 1000-220 RER 225 (P) 1 223,0 146,0 28,0 1,50 25,0 210,0 4x4,5 196,0 LZ 1000-225 (P) = plastic, (S) = sheet steel q Øu Øk Øm t 5,5 6 x 60° 45° 4 x 90° 118 4,3 245Øs 242 Vers. 2Vers. 1

– Connector cable with injection-moulded plug in various lengths. – Strand ends with core-crimping sleeve, core-end sleeve or tin-plated. – Straight or angled plug. – For all types of fan with flat plug 2.8 / 3.0 x 0.5. Connector cables LZ120 610 0,5 mm 2 G C black/black 2,8 x 0,5 AC LZ120-4 2 000 0,5 mm 2 G A black/black 2,8 x 0,5 AC LZ120-5 380 0,5 mm 2 W B red/black 2,8 x 0,5 DC LZ120-6 610 0,5 mm 2 W B red/black 2,8 x 0,5 DC LZ120-11 2 000 0,5 mm 2 G A red/black 2,8 x 0,5 DC LZ120-16 800 0,5 mm 2 G B black/black 2,8 x 0,5 AC LZ120-18 4 000 0,5 mm 2 G A black/black 2,8 x 0,5 AC LZ126 1 000 0,5 mm 2 G C black/black 2,8 x 0,5 AC LZ127 1 600 0,5 mm 2 G B black/black 2,8 x 0,5 AC LZ130-1 610 0,82 mm 2 G C black/black 2,8 x 0,5 AC LZ140 610 0,73 mm 2 G B black/black 2,8 x 0,8 AC Plug model L1 (mm) Leads Plug Leads end Lead colour Receptacle for tabs Application Connector cable Straight plug (G) Connector cable Angled plug (W) 7,5 16,5 22,5 31 L1 8,5 ±0,1 –0,5 7,5

20 L1+0,5

8,5 ±0,2 ±0,1 43,5 –0,25 5,5 –0,25 /c187Ø1,5 Core crimp sleeve Leads end A Tin-plated Leads end B /c187Ø1,5 Core end sleeve Leads end C InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans

In addition to the accessories and assembly parts listed in this catalogue, ebm-papst also supplies numerous special parts for fans. The sales experts at ebm-papst will be happy to assist you in your enquiries concerning fan assembly and application. LZ212 LZ260/LZ261 LZ210 Required performance data: R B-value P = 0,25 Wmax = 100 K 5% @25°C = 4190 2% LZ370 Ø 6,6 (2x) Ø 4 Ø1 1 (2x) 0,5x45° 50° 0,5 6,9 ±0,1 11±0,3 LZ550

8300 LZ212 / LZ260

8400 N LZ261

3300 LZ212 / LZ260

3400 N LZ261

9000 LZ210

4000 LZ210

4300 LZ212 / LZ260

8300 LZ212

5100 LZ210

5600 LZ210

5200 LZ210

5900 LZ210

7000 LZ210

Screw clip of stainless steel. For mounting fans with threaded pin 3.5 DIN EN ISO 1478 (7970). Screw clip of hardened steel. For mounting fans with threaded pin 6-32 UNC and/or 3.5 DIN 7970. Temperature sensor for speed-controlled Rubber anti-vibration mounts for fans with a hole ø of 4.3 ±0.2 mm and flange thickness of 3 - 5.5 mm. For a carrier plate with a hole ø of 6.5 ±0.15 mm and plate thickness of1-2m m . Spacer of fibreglass reinforced plastic. For screw mounting over both fan mounting flanges.

InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans

Dipl.-Ing. Mark Gartner Gehrweg 12 D-74199 Unterheinriet Phone +49 7130 404569-1 Fax +49 7130 404569-2 Mark.Gartner@de.ebmpapst.com Kassel Dipl.-Ing. (FH) Ralph Brück Hoherainstraße 3 b D-35075 Gladenbach Phone +49 6462 4071-10 Fax +49 6462 4071-11 Ralph.Brueck@de.ebmpapst.com Koblenz Winfried Schaefer Hinter der Kirch 10 D-56767 Uersfeld Phone +49 2657 16-96 Fax +49 2657 16-76 Winfried.Schaefer@de.ebmpapst.com Munich Dipl.-Wirt.-Ing. (FH) Jens Peter Uhlandstraße 6 D-74427 Fichtenberg Phone +49 7971 260-180 Fax +49 7971 260-221 Jens.Peter@de.ebmpapst.com Nuremberg Dipl.-Wirt.-Ing. (FH) Axel Resch Steinsfeldstraße 80 D-74626 Bretzfeld Phone +49 7946 94401-02 Fax +49 7946 94401-03 Axel.Resch@de.ebmpapst.com Offenburg Dipl.-Ing. (FH) Ralf Braun Hubeneck 21 D-77704 Oberkirch Phone +49 7802 9822-52 Fax +49 7802 9822-53 Ralf.Braun@de.ebmpapst.com Stuttgart Dipl.-Ing. (FH) Rudi Weinmann Hindenburgstraße 100/1 D-73207 Plochingen Phone +49 7153 9289-80 Fax +49 7153 9289-81 Rudi.Weinmann@de.ebmpapst.com Ulm M.Sc. Reinhard Sommerreißer Am Silbermannpark 10 D-86161 Augsburg Phone +49 821 6610-7023 Fax +49 821 6610-7024 Reinhard.Sommerreisser@de.ebmpapst.com Distributors Burgdorf ETB Electronic Team Beratungs- u. Vertriebs GmbH Wundramweg 1

31303 Burgdorf

info@etb-electronic.de www.etb-electronic.de Frankfurt R.E.D. Handelsgesellschaft mbH Gutenbergstraße 3 D-63110 Rodgau - Jügesheim Phone +49 6106 841-0 Fax +49 6106 841-111 info@red-elektromechanik.de www.red-elektromechanik.de Arrow Central Europe GmbH Max-Planck-Straße 1-3

63303 Dreieich

spoerle@spoerle.e-mail.com www.spoerle.com Hamburg Breuell + Hilgenfeldt GmbH Grützmühlenweg 40 D-22339 Hamburg Phone +49 40 538092-20 Fax +49 40 538092-84 info@breuell-hilgenfeldt.de Walter Kluxen GmbH Neuer Höltigbaum 6

20097 Hamburg

Dipl.-Ing. (TH) Jens Duchow Händelstraße 7 D-16341 Panketal Phone +49 30 944149-62 Fax +49 30 944149-63 Jens.Duchow@de.ebmpapst.com Bielefeld Dipl.-Ing. (FH) Wolf-Jürgen Weber Niehausweg 13 D-33739 Bielefeld Phone +49 5206 91732-31 Fax +49 5206 91732-35 Wolf-Juergen.Weber@de.ebmpapst.com Dortmund Dipl.-Ing. (FH) Hans-Joachim Pundt Auf den Steinern 3 D-59519 Möhnesee-Völlinghausen Phone +49 2925 800-407 Fax +49 2925 800-408 Hans-Joachim.Pundt@de.ebmpapst.com Frankfurt Dipl.-Ing. Christian Kleffmann Dr.-Hermann-Krause-Straße 23 D-63452 Hanau Phone +49 6181 1898-12 Fax +49 6181 1898-13 Christian.Kleffmann@de.ebmpapst.com Halle Dipl.-Ing. (TU) Michael Hanning Lercheneck 4 D-06198 Salzatal / OT Lieskau Phone +49 345 55124-56 Fax +49 345 55124-57 Michael.Hanning@de.ebmpapst.com Hamburg Ingenieurbüro Breuell GmbH Ing. Dirk Kahl Elektroingenieur Grützmühlenweg 40 D-22339 Hamburg Phone +49 40 538092-19 Fax +49 40 538092-84 Dirk.Kahl@de.ebmpapst.com ebm-papst in Germany Germany ebm-papst Mulfingen GmbH & Co. KG Bachmühle 2 D-74673 Mulfingen Phone +49 7938 81-0 Fax +49 7938 81-110 info1@de.ebmpapst.com www.ebmpapst.com ebm-papst St. Georgen GmbH & Co. KG Hermann-Papst-Straße 1 D-78112 St. Georgen Phone +49 7724 81-0 Fax +49 7724 81-1309 info2@de.ebmpapst.com www.ebmpapst.com ebm-papst Landshut GmbH Hofmark-Aich-Straße 25 D-84030 Landshut Phone +49 871 707-0 Fax +49 871 707-465 info3@de.ebmpapst.com www.ebmpapst.com fan agent compact fan agent motor specialist motor agent

Beratungs- u. Vertriebs GmbH Zossener Straße 27

15838 Klausdorf

info@etb-electronic.de www.etb-electronic.de Munich A. Schweiger GmbH Ohmstraße 1 D-82054 Sauerlach Phone +49 8104 897-0 Fax +49 8104 897-90 info@schweiger-gmbh.de www.schweiger-gmbh.com Multi-Bauelemente-Service Vertrieb von elektr. Bauelementen GmbH Römerstraße 8

85661 Forstinning

multi.bauelemente@mbs.to (1 to 5 pieces) North Breuell + Hilgenfeldt GmbH Grützmühlenweg 40 D-22339 Hamburg Phone +49 40 538092-20 Fax +49 40 538092-84 ebmpapst@breuell-hilgenfeldt.de South Scheffel elektrotechnischer Vertrieb GmbH Aischbach 1

70839 Gerlingen

info@ebmpapst-service.de Europe Austria ebm-papst Motoren & Ventilatoren GmbH Straubingstraße 17 A-4030 Linz Phone +43 732 321150-0 Fax +43 732 321150-20 info@at.ebmpapst.com www.ebmpapst.at Avnet Time Vienna Diefenbachgasse 35/2 A-1150 Vienna Phone +43 1 8664 20 Fax +43 1 8664 2250 TimeAustria@avnet.com www.avnettime.com Belarus ebm-papst Bel AgmbH P .O. Box 117 BY-220138 Minsk Phone +375 17 3851556 Fax +375 17 3851556 info@by.ebmpapst.com www.ebmpapst.by Belgium ebm-papst Benelux B.V. Sales office Belgium-Luxemburg Romeinsestraat 6/0101 Research Park Haasrode B-3001 Heverlee-Leuven Phone +32 16 396-200 Fax +32 16 396-220 info@be.ebmpapst.com www.ebmpapst.be Avnet Time Diegem Eagle Building Kouterveldstraat 20 B-1831 Diegem Phone +32 27 099003 Fax +32 27 099801 TimeBe@avnet.com www.avnettime.com Bulgaria ebm-papst Romania S.R.L. Str. Tarnavei Nr. 20 RO-500327 Brasov Phone +40 268 312-805 Fax +40 268 312-805 dudasludovic@xnet.ro Compex Ges.m.b.H Wurlitzergasse 10/3 A -1160 Wien Phone +43 1 4804223 Fax +43 1 4864230 compex.wien@utanet.at Croatia ebm-papst Industries Kft. Ezred u. 2. H-1044 Budapest Phone +36 1 8722-190 Fax +36 1 8722-194 office@hu.ebmpapst.com Compex Ges.m.b.H Wurlitzergasse 10/3 A -1160 Wien Phone +43 1 4804223 Fax +43 1 4864230 compex.wien@utanet.at Czech Republic / Slovakia ebm-papst CZ s.r.o. Kaštanová 34a CZ-620 00 Brno Phone +420 544 502-411 Fax +420 547 232-622 info@ebmpapst.cz www.ebmpapst.cz InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans ebm-papst in Germany and Europe

ebm-papst Industries Kft. Ezred u. 2. H-1044 Budapest Phone +36 1 8722-190 Fax +36 1 8722-194 office@hu.ebmpapst.com Compex KFT. Elete út 56/B H-1115 Budapest Phone +36 12 0657 25 Fax +36 12 0657 71 compex@vnet.hu Iceland RJ Engineers Stangarhyl 1a IS-110 Reykjavik Phone +354 567 8030 Fax +354 567 8015 rj@rj.is www.rj.is Ireland ebm-papst UK Ltd. Chelmsford Business Park GB-Chelmsford Essex CM2 5EZ Phone +44 1245 468555 Fax +44 1245 466336 sales@uk.ebmpapst.com www.ebmpapst.co.uk AuBren Limited Portlaoise Business & Technology Park Mountrath Road IRL-Portlaoise, Co. Laois Phone +353 57 8664343 Fax +353 57 8664346 sales@ie.aubren.com www.aubren.com Italy ebm-papst Srl Via Cornaggia 108 I-22076 Mozzate (Co) Phone +39 0331 836201 Fax +39 0331 821510 info@it.ebmpapst.com www.ebmpapst.it Macedonia ebm-papst Industries Kft. Ezred u. 2. H-1044 Budapest Phone +36 1 8722-190 Fax +36 1 8722-194 office@hu.ebmpapst.com Netherlands ebm-papst Benelux B.V. Engelseweg 127 NL-5705 AC Helmond Phone +31 492 502-900 Fax +31 492 502-950 verkoop@nl.ebmpapst.com www.ebmpapst.nl Avnet Time Breda Takkebijsters 2 NL-4817 BL Breda Phone +31 765 722300 Fax +31 765 722303 Time NL@avnet.com www.avnettime.com Norway ebm-papst AS P .B. 173 Holmlia N-1203 Oslo Phone +47 22 763340 Fax +47 22 619173 mailbox@ebmpapst.no www.ebmpapst.no Poland ebm-papst Polska Sp. z o.o. ul. Annopol 4A PL-03236 Warszawa Phone +48 22 6757819 Fax +48 22 6769587 office@ebmpapst.pl www.ebmpapst.pl Compex Ges.m.b.H Wurlitzergasse 10/3 A -1160 Wien Phone +43 1 4804223 Fax +43 1 4864230 compex.wien@utanet.at Denmark ebm-papst Denmark ApS Vallensbækvej 21 DK-2605 Brøndby Phone +45 43 631111 Fax +45 43 630505 mail@dk.ebmpapst.com www.ebmpapst.dk Estonia ebm-papst Oy, Eesti Filiaal Kesk tee 13 Aaviku küla, Jüri Tehnopark EST-75301 Rae Vald, Harjumaa Phone +372 65569-78 Fax +372 65569-79 www.ebmpapst.ee Finland ebm-papst Oy Puistotie 1 FIN-02760 Espoo Phone +358 9 887022-0 Fax +358 9 887022-13 mailbox@ebmpapst.fi www.ebmpapst.fi France ebm-papst SARL ZI Nord - rue A. Mohler BP 62 F-67212 Obernai-Cedex Phone +33 820 326266 Fax +33 3 88673883 info@ebmpapst.fr www.ebmpapst.fr Greece Helcoma Th. Rotas & Co OE Davaki 65 GR-17672 Kallithea-Attiki Phone +30 210 9513-705 Fax +30 210 9513-490 contact@helcoma.gr www.helcoma.gr Assimacopoulos S.A. 11, Karitsi Square GR-10561 Athen Phone +30 10 322 1737 Fax +30 10 322 5708 assimac@interagora.gr www.assimacopoulos.gr ebm-papst in Europe fan agent compact fan agent motor specialist motor agent

ebm-papst (Portugal), Lda. Centro Empresarial de Alverca Rua de Adarse, Vale D’Ervas Corpo D / Fracção 3 P-2615-178 Alverca do Ribatejo Phone +351 218 394 880 Fax +351 218 394 759 info@pt.ebmpapst.com www.ebmpapst.pt Romania ebm-papst Romania S.R.L. Str. Tarnavei Nr. 20 RO-500327 Brasov Phone +40 268 312-805 Fax +40 268 312-805 dudasludovic@xnet.ro Compex Ges.m.b.H Wurlitzergasse 10/3 A -1160 Wien Phone +43 1 4804223 Fax +43 1 4864230 compex.wien@utanet.at Russia ebm-papst Ural GmbH Posadskaja-Strasse, 23(E), 3 RU-620102 Ekaterinburg Phone +7 343 2338000 Fax +7 343 2337788 Konstantin.Molokov@ru.ebmpapst.com www.ebmpapst.ur.ru ebm-papst Rus GmbH proezd 4529, vladenie 5, stroenie 1 RU-141000 Mytistschi, Oblast Moskau Phone +7 495 9807524 Fax +7 495 5140924 info@ebmpapst.ru www.ebmpapst.ru Serbia & Montenegro ebm-papst Industries Kft. Ezred u. 2. H-1044 Budapest Phone +36 1 8722-190 Fax +36 1 8722-194 office@hu.ebmpapst.com Spain ebm-papst Ibérica S.L. Avda. del Sistema Solar, 29 E-28830 San Fernando de Henares (Madrid) Phone +34 91 6780894 Fax +34 91 6781530 ventas@ebmpapst.es Sweden ebm-papst AB Äggelundavägen 2 S-17562 Järfälla Phone +46 8 7619400 Fax +46 8 362306 info@ebmpapst.se www.ebmpapst.se Switzerland ebm-papst AG Rütisbergstrasse 1 CH-8156 Oberhasli Phone +41 44 73220-70 Fax +41 44 73220-77 verkauf@ebmpapst.ch www.ebmpapst.ch Omni Ray AG Im Schörli 5 CH-8600 Dübendorf Phone +41 44 802 2880 Fax +41 44 802 2828 r.borner@omniray.ch www.omniray.ch Turkey Akantel Elektronik San. Tic. LTD. Sti. Atatürk Organize Sanayi Bölgesi 10007 SK. No.:6 TR-35620 Cigli-Izmir Phone +90 232 3282090 Fax +90 232 3280270 akantel@akantel.com.tr www.ebmpapst.com.tr Ukraine ebm-papst Ukraine LLC Lepse Boulevard, 4, Building 47 UA-03067 Kiev Phone +38 044 2063091 Fax +38 044 2063091 mail@ebmpapst.ua www.ebmpapst.ua United Kingdom ebm-papst UK Ltd. Chelmsford Business Park GB-Chelmsford Essex CM2 5EZ Phone +44 1245 468555 Fax +44 1245 466336 sales@uk.ebmpapst.com www.ebmpapst.co.uk ebm-papst Automotive & Drives (UK) Ltd. The Smithy Fidlers Lane GB-East Ilsley, Berkshire RG20 7LG Phone +44 1635 2811-11 Fax +44 1635 2811-61 A&Dsales@uk.ebmpapst.com www.ebmpapst-ad.com InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans ebm-papst in Europe

ebm-papst de Argentina S.A. Hernandarias 148 Lomas del Mirador Pcia. de Buenos Aires (1752) Phone +54 11 46576135 Fax +54 11 46572092 ventas@ar.ebmpapst.com www.ebmpapst.com.ar Brasil ebm-papst Motores Ventiladores Ltda. Av. José Giorgi, 301 Galpões B6+B7 Condominio Logical Center BR-06707-100 Cotia - São Paulo Phone +55 11 4613-8700 Fax +55 11 3164-8924 vendas@br.ebmpapst.com www.ebmpapst.com.br Canada ebm-papst Canada Inc.

1800 Ironstone Manor, Unit 2

CDN-Pickering, Ontario, L1W3J9 Phone +1 905 420-3533 Fax +1 905 420-3772 sales@ca.ebmpapst.com www.ebmpapst.ca Mexico Paseo de Tamarindos 400-A-5 to Piso Col. Bosques de las Lomas MEX-Mexico 05120, D.F. Phone +52 55 3300-5144 Fax +52 55 3300-5243 sales@mx.ebmpapst.com www.ebmpapst.com.mx USA ebm-papst Inc. P .O. Box 4009

100 Hyde Road

USA-Farmington, CT 06034 Phone +1 860 674-1515 Fax +1 860 674-8536 sales@us.ebmpapst.com www.ebmpapst.us ebm-papst Automotive & Drives, Inc.

3200 Greenfield, Suite 255

USA-Dearborn, MI 48120 Phone +1 313 406-8080 Fax +1 313 406-8081 automotive@us.ebmpapst.com www.ebmpapst-automotive.us Africa South Africa ebm-papst South Africa (Pty) Ltd. P .O. Box 3124

1119 Yacht Avenue

info@za.ebmpapst.com www.ebmpapst.co.za Retron CC P .O. Box 3 94 48, Bramley, 2018 SSF-Building, 706 - 4th Street, Wynberg ZA-Johannesburg Phone +27 11 7860553 Fax +27 11 4408275 Asia China ebm-papst Ventilator (Shanghai) Co., Ltd. No. 418, Huajing Road WaiGaoQiao Free Trade Zone No. 2001, Yang Gao (N) Road VRC-200131 Shanghai, P .R. of China Phone +86 21 5046-0183 Fax +86 21 5046-1119 sales@cn.ebmpapst.com www.ebmpapst.com.cn Hong Kong ebm-papst Hong Kong Ltd. Unit No. 13,9 / F Technology Park, 18 On Lai Street Siu Lek Yuen, Shatin N.T. Hong Kong - P .R. of China Phone +852 2145-8678 Fax +852 2145-7678 info@hk.ebmpapst.com India ebm-papst India Pvt. Ltd. 26/3, G.N.T. Road, Erukkencherry IND-Chennai-600118 Phone +91 44 25372556 Fax +91 44 25371149 sales@in.ebmpapst.com www.ebmpapst.in Indonesia ebm-papst Indonesia Representative Office German Centre, 4th Floor, Suite 4470 Jl. Kapt. Subijono Dj. Bumi Serpong Damai RI-15321 Tangerang Phone +62 21 5376250 Fax +62 21 5388305 salesdept@id.ebmpapst.com Israel Polak Bros. Import Agencies Ltd.

9 Hamefalsim Street

IL-Kiryat Arie, Petach-Tikva 49514 Phone +972 3 9100300 Fax +972 3 5796679 polak@polak.co.il www.polak.co.il ebm-papst in America, Africa and Asia fan agent compact fan agent motor specialist motor agent

ebm-papst Industries Japan K.K. 12 Floor, Benex S-3 Bldg. 3-20-8 Shinyokohama, Kohoku-ku J-222-0033 Yokohama Phone +81 45 47057-51 Fax +81 45 47057-52 info@jp.ebmpapst.com www.ebmpapst.jp Korea ebm-papst Korea Co. Ltd. 6F, Trutec Bldg. B 6-2, Digital Media City (DMC) Sangam-Dong, Mapo-Gu ROK-Seoul 121-270 Phone +82 2 366213-24 Fax +82 2 366213-26 info@kr.ebmpapst.com www.ebmpapst.co.kr Malaysia ebm-papst Malaysia Representative Office Unit 12-2, Jalan USJ Sentral 3 Persiaran Subang, Selangor Darul Ehsan MAL-47600 Subang Jaya Phone +60 3 8024-1680 Fax +60 3 8024-8718 salesdept@my.ebmpapst.com Singapore ebm-papst SEA Pte. Ltd. No. 23 Ubi Road 4 #06-00 Olympia Industrial Building SGP-Singapore 408620 Phone +65 65513789 Fax +65 68428439 salesdept@sg.ebmpapst.com Taiwan ETECO Engineering & Trading Corp. 10F-I, No. 92, Teh-Wei Str. RC-Tsow-Inn District, Kaohsiung Phone +886 7 557-4268 Fax +886 7 557-2788 eteco@ms22.hinet.net www.ebmpapst.com.tw Thailand ebm-papst Thailand Co., Ltd. 99/349 Na-Nakorn Bldg., 4th Floor Chaeng Wattana Road, Thungsonghong, THA-10210 Laksi, BKK Phone +66 2 57615-24 Fax +66 2 57615-42 salesdept@th.ebmpapst.com United Arab Emirates ebm-papst Middle East FZE PO Box 17755 Jebel Ali Free Zone / FZS1 / AP05 UAE-Dubai Phone +971 4 88608-26 Fax +971 4 88608-27 info@ae.ebmpapst.com www.ebmpapst.ae Vietnam ebm-papst Vietnam Representative Office Room #102, 25 Nguyen Van Thu Street District 1 VN-Ho Chi Minh City Phone +84 8 39104099 Fax +84 8 39103970 linh.nguyen@vn.ebmpapst.com Australia Australia ebm-papst A&NZ Pty Ltd.

10 Oxford Road

AUS-Laverton North, Victoria, 3026 Phone +61 3 9360-6400 Fax +61 3 9360-6464 sales@ebmpapst.com.au www.ebmpapst.com.au New Zealand ebm-papst A&NZ Pty Ltd.

102 Henderson Valley Road

NZ-Henderson, Auckland 1230 Phone +64 9 837-1884 Fax +64 9 837-1899 sales@ebmpapst.com.au www.ebmpapst.com.au InformationDC axial fansDC fans - specialsACmaxx / i-maxxAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans ebm-papst in Asia and Australia

Mulfingen GmbH & Co. KG Bachmühle 2 D-74673 Mulfingen Phone +49 7938 81-0 Fax +49 7938 81-110 info1@de.ebmpapst.com ebm-papst St. Georgen GmbH & Co. KG Hermann-Papst-Straße 1 D-78112 St. Georgen Phone +49 7724 81-0 Fax +49 7724 81-1309 info2@de.ebmpapst.com www.ebmpapst.com ebm-papst Landshut GmbH Hofmark-Aich-Straße 25 D-84030 Landshut Phone +49 871 707-0 Fax +49 871 707-465 info3@de.ebmpapst.com L1136 · 980 0000 047 Printed in Germany