Ḥ Murata Power Solutions’ ACM20 series AC power meters display the most critical measurements in mains-powered equipment: voltage, amperage, active power (watts), and power factor. A front panel selector-switch provides two modes of operation: a fi xed reading of any of the four parameters, or a continuous cycling through all four measurements. An optional model displays line frequency with 0.1Hz resolution. All ACM20 multi-function power meters include built-in current transformers—no other user-supplied components are required. ACM20 series AC power meters are available in a choice of two input ranges: 0-32A 85-264Vac (47-63Hz) operating supply range makes these power meters perfect for worldwide power monitoring applications. And, unlike conventional, average-responding products, ACM20 power meters can accurately display the true-rms voltage and current values of triangle waves, square waves, and other irregularly shaped waveforms, with an accuracy of ±1% of full scale. Their large (0.36"/9.2mm), bright red LED display makes ACM20 AC power meters easily readable from as far as 15 feet (5 meters). All units are packaged in a one-piece, vibration resistant, polycarbonate housing that can be installed in vertical ‘0U’ and ‘1U’ rack spaces. Their miniature size is perfect for UPS power sources, power strips, labora- tory instrumentation, alternative energy applications, and any other products that require precise monitoring of AC power. PRODUCT OVERVIEW
FEATURES
/g132/g3Displays AC Volts, Amps, Watts, and Power Factor /g132/g3User-selectable display modes: continuous auto cycling, or fi xed reading /g132/g3Universal 85-264Vac (47-63Hz) operating range /g132/g3Built-in current transformers simplify installation; choice of 32A or 100A ranges /g132/g3Ideal for power distribution units (PDUs) and power strips /g132/g3True-rms readings of complex voltage and current waveforms /g132/g3Low-power consumption: less than ¼watt from 120Vac /g132/g3One-piece polycarbonate housing fi ts ‘0U’ & ‘1U’ racks /g132/g3Surface mount design occupies minimal panel space /g132/g3Bright red LED-display with four annunciators /g132/g3Optional Frequency reading models (0.1Hz resolution) Actual size SIMPLIFIED SCHEMATIC DIAGRAM A B 85-264 Vac 47-63 Hz AC/DC CONVERTER MICRO- CONTROLLER SEL +5V +5V +5V A/D CONVERTER LOAD CURRENT VOLTS AMPS WATTS PF ACM20 Series Four-Function AC Power Meters For full details go to www.murata-ps.com/rohs www.murata-ps.com/dpm www.murata-ps.com email: sales@murata-ps.com 08 Oct 2009 MPM_ACM20 Series.A03 Page 1 of 6
Measurement Limits Min. Typ. Max. Units AC Voltage 85.0 - 264.0 Volts AC Current, 32A models ➀ 0.00 - 32.00 Amperes AC Current, 100A models ➀ 0.0 - 100.0 Amperes Active Power: 32A models Active Power: 100A models 9999 26.4 Watts kW Frequency 47.0 - 63.0 Hz Power Factor .00 1.00 - - Overcurrent Rating ➁ 1.5 x rated full-scale current Performance Sampling Rate 2-3 samples / sec Voltage Accuracy ➂ ±1% Current Accuracy ➂ ±1% Power Accuracy ➂ ±2% Frequency Accuracy ➂ ±0.1 Hz Power Factor Accuracy ±3% Measurement Bandwidth 140Hz (Voltage), 14kHz (Current) Temperature Drift (0 to 60ºC) 0.5 Counts/ºC Zero-Current Reading (within 2 sec.) 0.00 Amps Zero-Power Reading (within 2 sec.) 0 Watts Supply Voltage (TB1) All Models – 47-63 Hz 85 120 264 Vac Supply Current ➃ All Models 35 50 110 mA Power Supply Terminal Block Wire Size 16-22AWG, solid or stranded Insulation Strip Length 6.4mm (0.250 in) Screw Tightening Torque 0.4Nm (3.6 lb-in) Rated Voltage 300Vac Display Display Type and Size 4 Digit LED, 9.14mm (0.36in) high Overrange Indication Flashing ‘9999’ Decimal Point Selection Automatically Set Physical/Environmental Operating Temperature 0 – +60 °C Storage Temperature –40 – +75 °C Humidity (non-condensing) 0 – 85 % Dimensions See mechanical specifi cations Weight: 32A models Weight: 100A models 1.3oz (37.9g) 1.5oz (43.5g) ① Specifi ed full-scale currents are those passing through the power meter’s built-in current transformer’s primary load-circuit. ➁ The overcurrent rating of 1.5 x the rated full-scale current is a continuous rating and applies to the current passing through the built in current transformer. Accuracy is guaranteed up to the rated current. ➂ ACM20 Power Meters are calibrated with near full-scale 60Hz sine-wave inputs. ➃ All specifi ed maximum supply currents are steady state; larger surge currents can occur at initial application of line power. Performance/Functional Specifi cations Typical at TA=+ 25ºC, 120Vac @ 60Hz, unless otherwise noted
ORDERING INFORMATION
ACM20-4-AC1-R-C 100A, 85-264Vac Supply (Power Factor Reading) ACM20-5-AC1-R-C 32A, 85-264Vac Supply (Power Factor Reading) ACM20-4-AC1-R-F-C 100A, 85-264Vac Supply (Frequency Reading) ACM20-5-AC1-R-F-C 32A, 85-264Vac Supply (Frequency Reading) TECHNICAL NOTES IMPORTANT! To ensure safe and reliable operation, ACM20 power meters must be installed and serviced by qualifi ed technical person- nel. Contact Murata Power Solutions if there is any doubt regarding their installation or operation. 1. Measurement Type : ACM20 series multi-function AC power meters employ a precision energy metering integrated circuit and a low- power microcontroller to measure and display the rms voltage and current, active(real) power, power factor (or line frequency on ‘–F’ suffi x models) of ac mains supplies from 47-63Hz. Please note, ACM20 power meters use the voltage present at their TB1 terminal block and the secondary current of their built-in current transformer L1 to calculate and then display VOLTS, WATTS, power factor (PF), or line frequency on ‘-F’ HERTZ models. 2. Basic Operation : Upon application of ac power to TB1, the unit will fi rst perform a self-test routine and then continuously display ac volts with the VOLTS LED annunciator illuminated. The display will remain in the VOLTS mode as long as the front panel 'SEL' button is not touched. After the unit powers up to normal operation in the VOLTS reading mode, momentarily (approximately one second) touching the ‘SEL’ button on the unit’s front panel three times in succession will cycle the display to AMPS, WATTS, and end at PF (or HERTZ for ‘–F’ mod- els). Momentarily touching ‘SEL’ a fourth time will return the display back to the VOLTS reading mode. Holding the 'SEL' button down for 3 seconds will place the unit in a continuous auto-cycling mode, and the display will repetitively scroll through all four measurements, with each measurement remaining displayed for 3 seconds. When the continuous auto-cycling mode is initially selected, the unit will briefl y display ‘Auto On’ before continuous cycling begins. Mo- mentarily touching the ‘SEL’ button again will cause the unit to briefl y display ‘Auto OFF’ before it returns to the fi xed VOLTS reading mode. 3. Calibration: Due their digital design, ACM20 power meters cannot be calibrated in the fi eld. ACM20 power meters are factory-calibrated to meet their specifi ed accuracies with the supplied L1 current trans- former. Use of any other current transformer will produce signifi cant errors for the Amps, Watts, and Power Factor measurements. Contact Murata Power Solutions if additional information is required regarding calibration, setup, or any other technical issue pertaining to ACM20 power meters. ACM20 Series Four-Function AC Power Meters www.murata-ps.com/dpm email: sales@murata-ps.com 08 Oct 2009 MPM_ACM20 Series.A03 Page 2 of 6
- Wiring: All power supply wiring must be rated for the voltages and
- Supply Fusing, and Grounding: ACM20 power meters are not inter-
nection is required to earth/chassis ground. line voltage is initially applied to TB1.
- Current Transformer Polarity: In order to perform accurate Watts
the line voltage connected to TB1-A and TB1-B.
120 Vac (50/60 Hz)
Figure 1. Wiring diagram for 110/120V single phase systems wire passing through the hole in L1.
- Connector Torque Ratings: I t is important to tighten TB1’s, screw-
- Isolation: Except for the 2-56 thread metallic mounting studs, all of
TYPICAL WIRING DIAGRAMS, CONT.
220 Vac (50/60 Hz)
Figure 2. Wiring diagram for 220/240V systems with no neutral Figure 3. Wiring diagram for 220/240V systems with neutral (monitoring L1) Figure 4. Wiring diagram for 220/240V systems with neutral (monitoring L2)
ing all safety measures applicable to the user’s installation. to current transformer L1, TB1, or to the ACM20 power meter itself. adequate strain reliefs be used for all wiring. installation and/or adversely affect the reliability of the installation. ammeter cutouts, allowing for easy upgrading of existing installations. Figure 5. Panel Installation
1.43 (36.3) 2.10 (53.3) Front View B B A A TB1 Lead Length 2.0 (50.5) min. Dia 32A models: 0.35 (8.9) 100A models: 0.57 (14.5) aamemeter: Back View 0.51 (12.95) 1.07 (27.20) 0.40 (10.16) 0.12 (3.05) (min) 0.12 (3.05) (min) Side View 1.63 (41.4)
0.086 DIA (REF)
0.33 (8.39) (min) 0.22 (5.59) (min) 0.60 (15.24) (max) Bottom View Dimensions are in inches (mm). Components are shown for reference only. Tolerances (unless otherwise specified): .XX ± 0.02 (0.51) Angles ± 2˚ ACM20 Series Four-Function AC Power Meters Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifi cations are subject to change without notice. © 2009 Murata Power Solutions, Inc. www.murata-ps.com/locations email: sales@murata-ps.com Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfi eld, MA 02048-1151 U.S.A. ISO 9001 and 14001 REGISTERED 08 Oct 2009 MPM_ACM20 Series.A03 Page 6 of 6