Technical content

Flexible LIN alternator regulator IC family The Infineon alternator control ICs are monolithic full featured regulators specifically de- signed for closed loop voltage control for 12 V automotive multi-phase alternators with a rotating field winding. They are qualified according to AEC-Q100 and tailored to withstand the harsh conditions of the automotive environment. The regulators are able to commu- nicate with an engine management or engery management ECU through a standard LIN interface (LIN 1.3/LIN 2.1/LIN 2.2 – see product table on page 2). The battery voltage is regulated at a precise value between 10.6 V and 16 V. By using free-adjustable parame- ters, the regulators are able to operate even without any communication interface. The family is compliant to various LIN alternator regulator specifications (see product table on page 2) and thus qualified and released by leading OEMs. The output driver stage consists of a high-side DMOS for up to 12 A excitation current to the field winding. The product family provides 8 kV ESD protection for all alternator lines. The EEPROM with adjustable parameters offers a customization of the alternator to the specific OEM or application needs. The TLE8881-2, latest addition to the Infineon LIN alternator regulator IC family, builds upon the success of the existing ICs (TLE8880, TLE8881, TLE8886) while also offering several advantages: › Easy switch from existing applications using MFC or LIN interface › Flexibility (LIN interface and enhanced EEPROM) › Enhanced regulation behavior.

Applications

› 12 V automotive alternators with LIN interface › 12 V truck alternators with LIN interface › 12 V aftermarket alternators › 12 V industrial generators › Full digital and fast PI regulation › High-side DMOS with RDS(on) of 60 mΩ › LIN 1.3, LIN 2.1, LIN2.2 › Very low stand-by current of 60 µA typ. › Reverse battery protected up to -2.5 V › High ESD resistivity of 8 kV › Duty cycle-range from 0 to 100 percent › Load Response Control (LRC) › Temperature range -40°C to 175°C › Digital temperature compensation › Available in TO-220-5-12 with straight leads Easy switch › Assisting functions to simplify design-in into existing applications with MFC interface › Compatible to existing Infineon LIN alternator ICs › Compliant to various LIN generator regulator specifications Flexibility › LIN 1.3, LIN 2.1 & LIN 2.2 › Fully configurable LIN IDs and filters › Enhanced EEPROM for customer specific adjustments Enhanced regulation behavior › Speed dependent current limitation › Speed and voltage dependent regu- lation parameter settings › Adapting overvoltage protection at low speed (Low HEO) Key features TLE888x family Key benefits TLE8881-2TN www.infineon.com/alternator

81726 Munich, Germany

© 2019 Infineon Technologies AG. All Rights Reserved. Order Number: B126-H9851-V1-7600-EU-EC-P Date: 09 / 2019 Please note! THIS DOCUMENT IS FOR INFORMATION PURPOSES ONLY AND ANY INFORMATION GIVEN HEREIN SHALL IN NO EVENT BE REGARDED AS A WARRANTY, GUARANTEE OR DESCRIPTION OF ANY FUNCTIONALITY, CONDITIONS AND/OR QUALITY OF OUR PRODUCTS OR ANY SUITABILITY FOR A PARTICULAR PURPOSE. WITH REGARD TO THE TECHNICAL SPECIFICATIONS OF OUR PRODUCTS, WE KINDLY ASK YOU TO REFER TO THE RELEVANT PRODUCT DATA SHEETS PROVIDED BY US. OUR CUSTOMERS AND THEIR TECHNICAL DEPARTMENTS ARE REQUIRED TO EVALUATE THE SUITABILITY OF OUR PRODUCTS FOR THE INTENDED APPLICATION. WE RESERVE THE RIGHT TO CHANGE THIS DOCUMENT AND/OR THE INFORMATION GIVEN HEREIN AT ANY TIME. Additional information For further information on technologies, our products, the application of our products, delivery terms and conditions and/or prices, please contact your nearest Infineon Technologies office (www.infineon.com). Warnings Due to technical requirements, our products may contain dangerous substances. For information on the types in question, please contact your nearest Infineon Technologies office. Except as otherwise explicitly approved by us in a written document signed by authorized representatives of Infineon Technologies, our products may not be used in any life- endangering applications, including but not limited to medical, nuclear, military, life-critical or any other applications where a failure of the product or any consequences of the use thereof can result in personal injury. Block diagramApplication support State machine diagnosis Battery measurement Registers LIN protocol handler Phase monitoring LIN transceiverEEPROM Digital core VBA EXC + Failure detections LIN Digital block Regulation block LIN interface EXC (Excitation) PH (Alternator phase) VBA (Battery) GND (Ground) › PI regulator › Filter, measurement units › Low excitation on, high excitation off, phase signal boost, excitation current limitation regulation, load response control › PEM signal generation Product family Product OPN Description LIN interface TLE8880TN TLE8880TNAKSA1 Compliant to LIN VDA specification LIN 1.3 (Datalink layer) LIN 2.1 (Physical layer) TLE8881TN TLE8881TNAKSA1 Compliant to LIN HKMC specification LIN 1.3 (Datalink layer) LIN 2.1 (Physical layer) TLE8886TN Variant 1 TLE8886TNAKSA1 Compliant to LIN Renault Nissan specification LIN 2.1 (Datalink layer) TLE8886TN Variant 2 TLE8886TNAKSA2 Compliant to LIN VDA specification LIN 2.1 (Datalink layer) TLE8881-2TN TLE88812TNAKSA1 Compliant to LIN VDA, Renault Nissan and HKMC specification LIN 1.3 (Datalink layer), LIN 2.1, LIN 2.2 (Datalink and Physical layer) ACIC BOARD ACICBOARDTOBO1 Interface board for Infineon LIN alternator control IC family – Infineon also provides an interface board (ACIC Board) together with interface software › Reliable and simple for fast design-ins › Easy EEPROM programming › Strong customer support TLE888x Flexible LIN alternator regulator IC family