WEBSITE: www.jdsu.com COMMUNICATIONS TEST & MEASUREMENT SOLUTIONS E t h e r N I D E E E t h e r n e t S e r v i c e s D e m a r c a t i o n P o i n t T h e A c c e d i a n E t h e r N I D ™ E E D e m a r c a t i o n D e v i c e ( E D D ) o f f e r s t h e s o l u t i o n t o t h e s e c h a l l e n g e s b y i m p l e m e n t i n g s t a n d a r d s b a s e d O A M a n d l o o p - b a c k c a p a b i l i t i e s . P r o v i d i n g a P e r f o r m a n c e A s s u r a n c e A g e n t ™ ( P A A ™ ) a l l o w s m e a s u r i n g a n d t r a c k i n g E n d - t o - E n d S L A p a r a m e t e r s s u c h a s L a t e n c y , J i t t e r , P a c k e t L o s s a n d A v a i l a b i l i t y i n a c o n t i n u o u s m a n n e r , w h i l e t h e s e rv i c e i s r u n n i n g . A c t i n g a s a n e l e c t r i c a l p o r t e x t e n s i o n t o b a s e m e n t - l o c a t e d A c c e s s P l a t f o r m s t h e E t h e r N I D ™ E E i s t h e i d e a l v e h i c l e t o d e f i n e a c l e a r n e t w o r k b o u n d a r y a t t h e c u s t o m e r p r e m i s e s o f m u l t i - t e n a n t c o m m e r c i a l e n v i r o n m e n t s . T h e E t h e r N I D ™ i s a l s o u s e d a t i n t e r - c a r r i e r h a n d o f f p o i n t s t o s e c t i o n a l i z e E - L i n e s t h a t s p a n a c r o s s m u l t i p l e s e r v i c e p r o v i d e r s , t h u s e l i m i n a t i n g f i n g e r p o i n t- i n g . F u r t h e r m o r e , t h e E t h e r N I D ™ E E ' s h i g h - p e r f o r m a n c e F a s t - T h r u ™ e n g i n e m i n i m i z e s i n t r i n s i c p a c k e t - j i t t e r a n d l a t e n c y o f t h e d e v i c e , t h u s a l l o w i n g t h e d e p l o y m e n t o f m u l t i p l e u n i t s a l o n g a n E n d - t o - E n d E t h e r n e t S e rv i c e P a t h w i t h o u t i n t r o d u c i n g a n y s i g n i f i c a n t l a t e n c y o r j i t t e r t o t h e s e r v i c e i t s e l f . T h e E t h e r N I D ™ E E ' s p o r t s c a n a l s o b e c o n f i g u r e d f o r M o n i t o r i n g w h e r e e x t e r n a l t e s t d e v i c e s c a n b e c o n n e c t e d t o p e r f o r m n o n - i n t r u s i v e , i n - s e r v i c e t r o u b l e s h o o t i n g , t h u s o f f e r i n g L a y e r 1 t o 4 v i s i b i l i t y i n e a c h d i r e c t i o n i n d e p e n d e n t l y o r c o m b i n e d , a f u n c t i o n t h a t c a r r i e r s a r e u s e d - t o w i t h t r a d i t i o n a l d e m a r c a t i o n d e v i c e s b u t l a c k i n g f r o m c u r r e n t E t h e r n e t s e rv i c e d e l i v e r y m e t h- o d s . F u r t h e r m o r e , i n t e l l i g e n t w i r e - s p e e d f i l t e r s c a n b e a p p l i e d t o s e l e c t i v e l y m o n i t o r s p e c i f i c t r a f f i c . A d d i t i o n a l l y , t h e E t h e r N I D ™ E E c a n b e o p t i o n a l l y l i n e - p o w e r e d u s i n g P o w e r o v e r E t h e r n e t ( P o E ) a n d o f f e r s a f a i l - o v e r b y p a s s c i r c u i t r y ( e l e c t r i c a l ) f o r a d d e d r e l i a b i l i t y . T h e E t h e r N I D ™ E E i n t e r a c t s s e a m l e s s l y w i t h E t h e r n e t O A M c o m p l i a n t d e v i c e s , s u p p o r t s S N M P , c o m e s w i t h a n e m b e d d e d W e b G U I a n d c a n b e o p t i o n a l l y m a n a g e d v i a a M a n a g e m e n t V L A N . D e s i g n e d v e r y c o s t e f f e c t i v e l y f o r v o l u m e d e p l o y m e n t , t h e E t h e r N I D ™ E E u n l o c k s t h e b u s i n e s s - c a s e f o r H i g h - P e r f o r m a n c e , m a n a g e a b l e M e t r o E t h e r n e t s e r v i c e d e l i v e r y i n t h e l a s t - m i l e . The growing demand for Ethernet Services is exploding everywhere. C a r r i e r s c o n t e n d i n g i n t h i s c o m p e t i t i v e m a r k e t s p a c e a r e f a c e d w i t h s e v- e r a l c h a l l e n g e s :

  • Setting a clear Demarcation Point between the Customers' and the Carriers' Ethernet Network
  • Implementing Operations, Administration and Maintenance (OAM), to reduce OPEX and minimize truck-roll
  • Assuring End-to-End Service Level Agreement (SLA) parameters
  • Offering Carrier-Grade Reliability All of this while avoiding any impact on network performance and keeping CAPEX at a minimum Key features

F e a t u r e s a n d B e n e fi t s Ethernet OAM & loop-backs B e t t e r v i s i b i l i t y , e a s i e r m a i n t e n a n c e , r e d u c e d t r u c k - r o l l s Dual Tap/Monitoring ports A l l o w s n o n - i n t r u s i v e M o n i t o r i n g A c c e s s t o l i v e t r a f f i c , a v o i d s c h a s i n g “ g h o s t s ” Traffic Filtering/Policing A l l o w s b l o c k i n g u n w a n t e d t r a f f i c t y p e s ( e . g . B P D U / S T P / L 2 C P ) a n d c o n t r o l l i n g w h i c h V L A N s a r e a l l o w e d Per-Flow Statistics A l l o w s t r a c k i n g b a n d w i d t h u t i l i z a t i o n o f e v e r y s t r e a m / E V C d e l i v e r e d

  • Customer Premises Located Intelligent Ethernet Demarcation Device
  • Inter-Carrier Handoff Demarcation
  • End-to-End SLA-Meter™
  • Intelligent extension to Metro Access Platforms
  • Wire-speed Remote Loop-back responder to Portable or Centralized Ethernet Test-sets
  • Intelligent Wire-speed Ethernet Monitor/Tap troubleshooting device Multi-carrier Performance Assurance Agent™ (PAA™) Application
  • Assures in-service, End-to-End SLA across Multi-Vendor/Multi-Carrier and Layer 1-2-3 networks Business Multi-Tenant Building Application NID Accedian EtherNID™ CPE Customer Provided Equipment

Connector: RJ-45 (Auto-negotiation/Auto MDIX) Client-side interface 10/100BaseTX Connector: RJ-45 (Auto-negotiation/Auto MDIX) NID features IEEE 802.3ah Ethernet OAM Implements a Two-Port MAC Relay (TPMR) function aligned with IEEE's 802.1aj, 802.1ad, and 802.1ag/ITU-T Y.1731 drafts Loop-backs: – Layer 1, Layer 2 (MAC Swap), Layer 3 (IP Swap), Layer 4 (TCP/UDP Port Swap) – Automatically reacts to in-band loop-back commands of industry-popular Ethernet test- sets – Individual VLAN loop-backs – Loop-back on specific MAC source and/or destination address – Loop-back on specific IP source and/or desti- nation address Thru-Traffic Per-flow statistics (per VLAN, per Ethertype, per ToS, per CoS, per MAC, per IP , etc.) VLAN Tagging/De-tagging VLAN Stacking (.1Q in .1Q) Through Traffic Wire-Speed Filtering (L2CP , BPDU, per-VLAN, Ethertype, Protocol type,MAC, IP ,User Defined) Dual Monitor Access Ports providing individual access to both ignal directions, combined access to both directions, Layer 1 apping and intelligent filtering Integrated Copper TDR cable integrity testing Dying Gasp (via 802.3ah or SNMP traps) Supports packet sizes up to 1800 bytes Fault Propagation Performance Assurance Agent™ (PAA™) Constant in-service monitoring of SLA param- eters including: Packet loss – Two-way delay (Round-trip Latency) – Two-way delay variation (Round-trip Jitter) – One-way delay variation (One-way Jitter) – Continuous End-to-End path Continuity Check High Precision measurements: 1 microsecond accuracy Works at Layer 2 and Layer 3 Assures SLAs per VLAN/per CoS/per ToS/per EVC Can work in point-to-point or point-to-multi- point Multiple Instance capable (Multi-SLA™) User settable SLA threshold crossing alerts using SNMP traps Inline transparent performance Throughput: wire-speed (100Mb/s at 100% utilization) Intrinsic Passthrough Traffic Latency: <8 micro- second (at all packet sizes) Intrinsic Passthrough Traffic Jitter: <1 microsec- ond (at all packet sizes) Intrinsic Latency for Intelligent Loopback: <8 microsecond (at all packet sizes) Intrinsic Jitter for Intelligent Loopback: <1 microsecond (at all packet sizes) Optional Network-Client Power Fail-over bypass mode Physical 1.60" H x 5.34" W x 5.80" D Mounting: – Desktop – Wall-mount – Rack-mount (2 units side-by-side in 1U) – 12 position, high-density, 19” central office shelf (4U): EtherSHELF™ Management In-band remote management over the Ethernet customer line via Network-side inter- face Local Management craft port: 10/100BaseT, RJ-45 connector Serial RS-232 Management port: RJ-45 con- nector Secure Web GUI via SSL Secure CLI command prompt via SSH SNMP V1,V2C Management VLAN 802.3ah EFM OAM NTP client Remote and Local Syslog Radius Authentication DNS Client DHCP Client Config. import/export FTP ,TFTP , SFTP , HTTP Power options all included as standard and redundant between each other External AC/DC adapter (120-240 Vac auto- sensing, 50-60 Hz), 5 Vdc input to unit Dual (A/B) -48Vdc Central Office Supply inputs PoE from RJ-45 (802.3af ) Power Consumption: 5 watts Cooling: convection cooled (no fans) Regulatory IEC 60950 FCC Part 15 Class A Industry Canada CS-03 CE Mark Operating Temperature 0-50 degree C Storage Temperature -40 to 70 degree C Humidity 5-95% non-condensing

All statements, technical information and recommendations related to the products herein are based upon infor - mation believed to be reliable or accurate. However, the accuracy or completeness thereof is not guaranteed, and no responsibility is assumed for any inaccuracies. The user assumes all risks and liability whatsoever in connec- tion with the use of a product or its applications. JDSU reserves the right to change at any time without notice the design, specifications, function, fit or form of its products described herein, including withdrawal at any time of a product offered for sale herein. JDSU makes no representations that the products herein are free from any intellectual property claims of others. Please contact JDSU for more information. JDSU and the JDSU logo are trademarks of JDS Uniphase Corporation. Other trademarks are the property of their respective holders. Test & Measurement Regional Sales NORTH AMERICA TEL: 1 866 228 3762 FAX: +1 301 353 9216 LATIN AMERICA TEL:+55 11 5503 3800 FAX:+55 11 5505 1598 ASIA PACIFIC TEL:+852 2892 0990 FAX:+852 2892 0770 EMEA TEL:+49 7121 86 2222 FAX:+49 7121 86 1222 WEBSITE: www.jdsu.com ETHERNID EE Model number Product name Description ACC701-000 EtherNID™ EE 10/100Mb/s Electrical-to-Electrical Ethernet Demarcation Device. Accessories ACC704-000 EtherSHELF™ Rackmount 4U Vertical Mounting Shelf, fits 12 EtherNID™ units individually fused, -48V (A/B) redundant power feeds, can mix and match EE, OE, and GE models. ACC706-000 2 Unit Rackmount Bracket Rackmount 1U Horizontal Mounting Bracket, fits 2 EtherNID™ units. ACC705-000 1 Unit Rackmount Bracket Rackmount 1U Horizontal Mounting Bracket, fits 1 EtherNID™ unit.

Related products

ACC703-000 EtherNID™ GE 10/100/1000Mb/s Ethernet Demarcation Device. ACC702-000 EtherNID™ OE 10/100Mb/s Optical to Electrical Ethernet EtherNID EE EtherNID GE EtherNID OE