Datasheet search site | www.alldatasheet.com

Document overview

  • PDF pages: 2

Technical content

© 2016 Littelfuse Protection Relays & Controls Protection Relays Pump Controls and Liquid Level Controls www.littelfuse.com/acbc120 Rev: 1-A-062716 Alarm Controller and Battery Charger for pump control panels ACBC-120 SERIES Wiring Diagram

Description

The ACBC-120 Series is a dual purpose alarm controller/battery charging unit. When there is a loss of 120VAC power, the ACBC-120’s primary function as an alarm controller activates. When this power loss occurs, input power is switched to a 12VDC, lead-acid, rechargeable backup battery and a 12VDC alarm consisting of a strobe light and/or a horn is activated. The horn follows a 2 second on/2 second off pattern with a “horn silence” option to turn the sound off. An LED indicator on the unit also signals that the device has entered the alarm mode. When 120VAC input is present the alarm circuit can be tested and the unit’s secondary function as a 12VDC backup battery charger is activated. In fast charge mode, the unit has the capability to source up to 100mA of charging current. However, the device normally charges at a current of 14mA in maintenance mode. The alarm circuit can be tested by pressing the “test” button located on the front of the unit or by activating an external switch via the “alarm contact” pin. The device has the ability to signal low battery voltage if the voltage drops below 10.5VDC. The device can also detect if no battery is present or if the battery is connected backwards. In either of these cases, the ACBC-120 will signal a battery error and will not attempt to charge. Must use Model SD12-PC socket for UL Rating! *Note: Manufacturer’s recommended screw terminal torque for the SD Series Sockets is 12 in.-lbs. Features & Benefits FEATURES BENEFITS Controls 12VDC alarm circuit Activates strobe and/or horn when power loss occurs Selectable fast charge mode Unit sources higher charging current up to 100mA (normal mode is 14mA) T rip delay timer Prevents nuisance tripping Battery fault detection and reverse polarity protection Signals if battery voltage drops below 10.5VDC and can detect if no battery is present or if the battery is connected backwards LED indication Visual indication of unit status or trip T est button Preventative maintenance check of the alarm circuit by pressing the test button on the unit or externally through alarm contact connection Accessories SD12-PC 12-pin Rectangle Socket Rectangle Socket for the ACBC-120. 12-pin surface mountable.

Ordering Information

ACBC-120 120VAC Does not include SD12-PC socket for mounting ACBC-120-SD 120VAC Includes SD12-PC socket for mounting

© 2016 Littelfuse Protection Relays & Controls Protection Relays Pump Controls and Liquid Level Controls www.littelfuse.com/acbc120 Rev: 1-A-062716 Specifications Input Characteristics Supply Voltage AC Input Voltage 120V +/-10% Frequency 50/60Hz AC Input Current 0.018A (max.) 0.003 (typical) AC Input Power 2.4W (max.) fast charge current 0.4W (typical) maint. charge current Functional Characteristics Battery Charging Characteristics Acceptable Battery Type 12V lead-acid rechargeable Fast Charge Current 100mA +/-10% Maintenance Charge Current 14mA +/-50% Low Battery Alert Level 10.5V Output Characteristics Strobe Light Alarm Output 12VDC@1A (max.) Horn Alarm Output 12VDC@1A (max.) General Characteristics Temperature Range -40° to 60°C (-40° to 140°F) ACBC-120 SERIES Standards Passed Electrostatic Discharge (ESD) IEC 61000-4-2, Level 3, 6kV contact, 8kV air Radio Frequency, Radiated 150MHz, 10V/m Fast Transient Burst IEC 61000-4-4, Level 4, 4kV input lines; 4kV signal lines Safety Marks UL (SD12-PC socket required) UL508 (File #E68520) Dimensions H 44.45 mm (1.75”); W 60.325 mm (2.375”); D 104.775 mm (4.125”) (with socket) Mounting Method Surface mount with #8 or #10 screws (plug into SD12-PC socket) Socket Available Model SD12-PC (UL Rating 600V) The 600V socket can be surface mounted