200 Watt Single Output U Frame
Input Characteristics AC Input Voltage Frequency Inrush Current EMI Isolation Leakage Current 90 ~ 264Vac 47 to 63Hz 6 0 A M a x . CISPR/FCC Class B Input to output = 4,242Vdc 3 . 5 m A m a x . Output Characteristics Total Rated Output Power Current Share Remote Voltage Sense Hold-up Time Over Voltage Protection Over Temperature Protection Short Circuit Protection 200W (with 30CFM air flow or optional fan) Single wire current sharing Compensates for wire voltage drop 16mS typ. Recycle AC input to restart Auto Recovery Auto Recovery Environmental Characteristics Operating Temperature Storage Temperature 0 ~ 70 degrees C 50~70 C with 2.5%/ degrees C derating PSU will be in thermal protection for exceeding the rated power output or the operating temperature -20 ~ 85 C Mechanical Outline Standard U Frame 150mmx100mmx38.1mm 1.5” Low Profile, 4”X6” Footprint Universal Input : 90 ~ 264Vac Active PFC Meets EN61000-3-2 EMI Meets CISPR/FCC Class B High Efficiency at 80% Typical Current Share Remote Voltage Sense AC OK Signal (Logic High) DC OK Signal (Logic High) PS ON/OFF Remote Control (Inhibit PSU by adding Logic High) NOTE 1: Optional function can be added when ordering: Top Cover with Fan (when forced air is needed) 2: Add a 0.1uF ceramic capacitor and a 47uF E.L. capacitor to output for Ripple & Noise measuring @ 2 0 M H z B W . 3: Voltage accuracy is set at 60% rated load and 25℃ Ta. 4: Line regulation is measured from High Line to Low Line with rated load. 5: Load regulation is measured at 60%±40% rated load. 6: Dimensions tolerance : +/- 1mm. 7: Connectors: CN1(AC Input) : Molex 5273-05A or equivalent CN2(DC Output) : Molex 38700-7504 or equivalent CN6(Signals) : Molex 70247-10 or equivalent CN3,CN4,CN5(FAN) : Molex 5045-02A or equivalent With Optional Fan 150mmx101.6mmx58.5mm BAUART TYPE APPROVED GEPRUFT . . Output Output Current (A) Ripple Voltage Line Load Model Voltage Rated Min. & Noise Accuracy Reg. Reg. Typical @25℃, 230Vac and 60% rated load, unless otherwise specified.
DRAWINGS: (Preliminary) CN1 Fig.1. Mechanical Outline of AC200 Unit: inch (mm) Fig.2. Mechanical Outline of AC200-F (With Optiona1 Fan) Unit: inch (mm) PIN CONNECTION: PIN9: NCPIN10: NC PIN5: +V VS PIN7: +V CSW PIN3: AC OK PIN1: GND PIN4: PS ON/OFF PIN2: DC OK PIN8: NC CN6(Signals) PIN6: +V GS CN1 (AC Input) PIN NO. ASSIGNMENT
1 Earth Ground
3 Neutral
5 Line
CN2 (DC Output, T.B.) PIN NO. ASSIGNMENT 1 +V 2 +V
3 PWR GND
4 PWR GND
CN3,CN4,CN5 (FAN Output) PIN NO. ASSIGNMENT 1 +12V(FAN)
2 GND(FAN)
Note: VS means Remote Sense ”+” GS means Remote Sense “Return” Fig.3. Output Derating Curve 2006/11/06 Ver. 19.0 100 125 150 175 200 0 1 02 03 04 05 06 07 08 0 Ambient Temperature (Deg.C) Rated Load (W With 30CFM Forced Air Convection Cool