Features

  • 1.5V to 5.5V Input Voltage Range
  • Very Low RDS(ON), Typically 80mW (5V)
  • Slew Rate Limited Turn-On Time Options ▪ 4.5ms ▪ 1ms ▪ 0.5µs ▪ 100µs
  • Fast Shutdown Load Discharge Option
  • Low Quiescent Current ▪ 25nA (typ)
  • TTL/CMOS Input Logic Level
  • Temperature Range: -40ºC to +85°C
  • 3kV ESD Rating
  • SC70JW-8, SOT23-6, and WLCSP-5 Packages

Applications

  • Cellular Telephones
  • Digital Still Cameras
  • Hot Swap Supplies
  • LCD Panels
  • Notebook Computers
  • Personal Communication Devices
  • Personal Digital Assistants (PDAs) Typical Application AAT4280A COUT 0.1µF CIN 1µF OUTIN GND VOUT GNDGND VIN ON/OFF GND IN ON

Slew Rate Controlled Load Switch Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 202230A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • July 31, 2012 Pin Descriptions Pin # Symbol FunctionSC70JW-8 SOT23-6 WLSCP-5 1, 5, 6, 7, 8 4, 6 1, 4 IN This pin is the input to the P-channel MOSFET source. Bypass to ground through a 1.0µF capacitor. 2 1 5 OUT This pin is the P-channel MOSFET drain connection. Bypass to ground through a 0.1µF capacitor. 3 3 2 ON/OFF Enable input. 4 5 3 GND Ground connection. Pin Configuration SC70JW-8 SOT23-6 WLCSP-5 (Top View) (Top View) (Top View) OUT ON/OFF GND IN IN IN IN IN 1 GND IN GND INON/OFF OUT 1 3 4 IN OUT45 IN GND ON/OFF1

Slew Rate Controlled Load Switch Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 202230A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • July 31, 2012 Selector Guide Part Number Slew Rate (typ) Active Pull Down Enable AAT4280A-1 1ms Active High AAT4280A-2 0.5µs Active High AAT4280A-3 100µs  Active High AAT4280A-4 4.5ms  Active High Absolute Maximum Ratings1 TA = 25°C, unless otherwise noted. Symbol Description Value Units VIN IN to GND -0.3 to 6 V VON ON/OFF to GND -0.3 to 6 V VOUT OUT to GND -0.3 to VIN + 0.3 V IMAX Maximum Continuous Switch Current 2.3 A IDM Maximum Pulsed Current IN ≥ 2.5V 6 A IN < 2.5V 3 A TJ Operating Junction Temperature Range -40 to 150 °C TS Storage Temperature Range -65 to 150 °C TLEAD Maximum Soldering Temperature (at leads) 300 °C VESD ESD Rating2 - HBM 3000 V Thermal Characteristics Symbol Description Package Value Units PD Maximum Power Dissipation SC70JW-83,4 714 mWSOT23-63,5 833 WLCSP-53,6 352 θJA Thermal Resistance SC70JW-8 140 °C/WSOT23-6 120 WLCSP-5 284 1. Stresses above those listed in Absolute Maximum Ratings may cause permanent damage to the device. Functional operation at condition other than the operating conditions specified is not implied. Only one Absolute Maximum Rating should be applied at any one time. 2. Human body model is a 100pF capacitor discharged through a 1.5kΩ resistor into each pin. 3. Mounted on an FR4 board; for the WLCSP package, use the NSMD (non-solder mask defined) pad style for tighter control on the copper etch process. 4. Derate 7.14mW/°C above 25°C. 5. Derate 8.33mW/°C above 25°C. 6. Derate 3.52mW/°C above 25°C.

Slew Rate Controlled Load Switch Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 202230A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • July 31, 2012

Electrical Characteristics

Unless otherwise noted, VIN = 5V, TA = -40°C to +85°C; typical values are T A = 25°C. Symbol Description Conditions Min Typ Max Units AAT4280A All Versions VIN Operation Voltage 1.5 5.5 V IQ Quiescent Current ON/OFF = Active 1 µA IQ(off) Off Supply Current ON/OFF = Inactive, OUT = Open 1 µA ISD(off) Off Switch Current ON/OFF = Inactive, VOUT = 0 1 µA RDS(on) On Resistance VIN = 5V, TA = 25°C 80 120 mW VIN = 4.2V, TA = 25°C 85 130 VIN = 3V, TA = 25°C 100 150 VIN = 1.8V, TA = 25°C 160 250 VIN = 1.5V, TA = 25°C 200 300 TCRDS On Resistance Temperature Coefficient 2800 ppm/°C VIL ON/OFF Input Logic Low Voltage VIN = 1.5V to 5.5V1 0.4 V VIH ON/OFF Input Logic High Voltage VIN = 1.5V to 2.7V 1.4 VVIN = 2.7V to 3.3V 1.5 VIN = 3.3V to 4.2V 1.6 VIN = 4.2V to 5.5V 2.4 ISINK ON/OFF Input Leakage VON/OFF = 5.5V 1 µA AAT4280A-1 TD(ON) Output Turn-On Delay VIN = 5V, RLOAD = 10W, TA = 25°C 20 40 µs TON Output Turn-On Rise Time VIN = 5V, RLOAD = 10W, TA = 25°C 1000 1500 µs TD(OFF) Output Turn-Off Delay Time VIN = 5V, RLOAD = 10W, TA = 25°C 4 10 µs AAT4280A-2 TD(ON) Output Turn-On Delay VIN = 5V, RLOAD = 10W, TA = 25°C 0.5 2 µs TON Output Turn-On Rise Time VIN = 5V, RLOAD = 10W, TA = 25°C 0.5 1 µs TD(OFF) Output Turn-Off Delay Time VIN = 5V, RLOAD = 10W, TA = 25°C 4 10 µs AAT4280A-3 TD(ON) Output Turn-On Delay VIN = 5V, RLOAD = 10W, TA = 25°C 20 40 µs TON Output Turn-On Rise Time VIN = 5V, RLOAD = 10W, TA = 25°C 100 150 µs TD(OFF) Output Turn-Off Delay Time VIN = 5V, RLOAD = 10W, TA = 25°C 4 10 µs RPD Output Pull-Down Resistance During OFF ON/OFF = Inactive, TA = 25°C 150 250 W AAT4280A-4 TD(ON) Output Turn-On Delay Time VIN = 3.3V, RLOAD = 10W, TA = 25°C 20 40 µs TON Output Turn-On Rise Time VIN = 3.3V, RLOAD = 10W, TA = 25°C 2000 4500 µs TD(OFF) Output Turn-OFF Delay Time VIN = 3.3V, RLOAD = 10W, TA =25°C 4 10 µs RPD Output Pull-Down Resistance During OFF ON/OFF = Inactive, TA = 25°C 150 250 W 1. For VIN outside this range, consult typical ON/OFF threshold curve.

Slew Rate Controlled Load Switch Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 202230A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • July 31, 2012 Typical Characteristics Unless otherwise noted, VIN = 5V, TA = 25°C. Quiescent Current vs. Temperature Temperature (°C) Quiescent Current (nA) -40 -20 02 04 06 08 0 100 RDS(ON) vs. Input Voltage Input Voltage (V) RDS(ON) (mΩ) 110 130 150 170 190 210 230 250 270 500mA 100mA RDS(ON) vs. Temperature 100 110 120 -40 -20 02 04 06 08 0 100 Temperature (°C) RDS(ON) (mΩ ) VIN = 5V VIN = 3V ON/OFF Threshold vs. Input Voltage Input Voltage (V) ON/OFF Threshold (V)0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 VIH VIL Off-Switch Current vs. Temperature 0.001 0.010 0.100 1.000 -40 -20 02 04 06 08 0 100 Temperature (°C) Off-Switch Current (µA)

Slew Rate Controlled Load Switch Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 202230A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • July 31, 2012 Typical Characteristics—AAT4280A-1 Unless otherwise noted, VIN = 5V, TA = 25°C. AAT4280A-1 Turn-On (VIN = 3V; RL = 6Ω) Time (500µs/div) ON/OFF (5V/div) VOUT (2V/div) IIN (200mA/div) AAT4280A-1 Turn-On (VIN = 5V; RL = 10Ω) Time (500µs/div) ON/OFF (5V/div) VOUT (2V/div) IIN (200mA/div) AAT4280A-1 Turn-Off (VIN = 3V; RL = 6Ω) Time (10µs/div) ON/OFF (5V/div) VOUT (2V/div) IIN (200mA/div) AAT4280A-1 Turn-Off (VIN = 5V; RL = 10Ω) Time (10µs/div) ON/OFF (5V/div) VOUT (2V/div) IIN (200mA/div)

Slew Rate Controlled Load Switch Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 202230A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • July 31, 2012 Typical Characteristics—AAT4280A-2 Unless otherwise noted, VIN = 5V, TA = 25°C. AAT4280A-2 Turn-On (VIN = 3V; RIN = 6Ω) Time (5µs/div) ON/OFF (5V/div) VOUT (2V/div) IIN (200mA/div) AAT4280A-2 Turn-On (VIN = 5V; RL = 10Ω) Time (5µs/div) ON/OFF (5V/div) VOUT (2V/div) IIN (200mA/div) AAT4280A-2 Turn-Off (VIN = 3V; RL = 6Ω) Time (5µs/div) ON/OFF (5V/div) VOUT (2V/div) IIN (200mA/div) AAT4280A-2 Turn-Off (VIN = 5V; RL = 10Ω) Time (5µs/div) ON/OFF (5V/div) VOUT (2V/div) IIN (200mA/div)

Slew Rate Controlled Load Switch Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 202230A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • July 31, 2012 Typical Characteristics—AAT4280A-3 Unless otherwise noted, VIN = 5V, TA = 25°C. AAT4280A-3 Turn-On (VIN = 3V; RL = 6Ω) Time (50µs/div) ON/OFF (5V/div) VOUT (2V/div) IIN (200mA/div) AAT4280A-3 Turn-On (VIN = 5V; RL = 10Ω) Time (50µs/div) ON/OFF (5V/div) VOUT (2V/div) IIN (200mA/div) AAT4280A-3 Turn-Off (VIN = 3V; RL = 6Ω) Time (5µs/div) ON/OFF (5V/div) VOUT (2V/div) IIN (200mA/div) AAT4280A-3 Turn-Off (VIN = 5V; RL = 10Ω) Time (5µs/div) ON/OFF (5V/div) VOUT (2V/div) IIN (200mA/div)

Slew Rate Controlled Load Switch Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 202230A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • July 31, 2012 Typical Characteristics—AAT4280A-4 Unless otherwise noted, VIN = 5V, TA = 25°C. AAT4280A-4 Turn-On (VIN = 3V; RL = 10Ω) Time (2ms/div) EN (2V/div) VOUT (2V/div) IIN (200mA/div) AAT4280A-4 Turn-On (VIN = 5V; RL = 10Ω) Time (2ms/div) EN (5V/div) VOUT (5V/div) IIN (500mA/div) AAT4280A-4 Turn-Off (VIN = 3.3V; RL = 10W) Time (10µs/div) EN (2V/div) VOUT (2V/div) IIN (200mA/div) AAT4280A-4 Turn-Off (VIN = 5V; RL = 10Ω) Time (10µs/div) EN (5V/div) VOUT (5V/div) IIN (500mA/div)

Slew Rate Controlled Load Switch Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 202230A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • July 31, 2012 Functional Description The AAT4280A is a family of flexible P-channel MOSFET power switches designed for high-side load switching applications. There are three versions of the AAT4280A with different turn-on and turn-off characteristics to choose from, depending upon the specific requirements of an application. The first version, the AAT4280A-1, has a moderate turn-on slew rate feature, which reduces inrush current when the MOSFET is turned on. This func- tion allows the load switch to be implemented with either a small input capacitor or no input capacitor at all. During turn-on slewing, the current ramps linearly until it reaches the level required for the output load condi - tion. The proprietary turn-on current control method works by careful control and monitoring of the MOSFET gate voltage. When the device is switched ON, the gate voltage is quickly increased to the threshold level of the MOSFET. Once at this level, the current begins to slew as the gate voltage is slowly increased until the MOSFET becomes fully enhanced. Once it has reached this point, the gate is quickly increased to the full input voltage and RDS(ON) is minimized. The second version, the AAT4280A-2, is a very fast switch intended for high-speed switching applications. This version has no turn-on slew rate control and no special output discharge features. The third switch version, the AAT4280A-3, has the addition of a minimized slew rate limited turn-on function and a shutdown output discharge circuit to rapidly turn off a load when the load switch is disabled through the ON/OFF pin. The final switch version, the AAT4280A-4, features a very slow turn-on slew rate with a typical value of 4.5ms for LCD panel applications. All versions of the AAT4280A operate with input voltages ranging from 1.5V to 5.5V. All versions of this device have extremely low operating current, making them ideal for battery-powered applications. The ON/OFF con- trol pin is TTL compatible and will also function with 2.5V to 5V logic systems, making the AAT4280A an ideal level-shifting load switch. Functional Block Diagram Level Shift IN ON/OFF OUT GND Turn-On Slew Rate Control *AAT4280A-3 and -4 only

Slew Rate Controlled Load Switch Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 202230A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • July 31, 2012 Applications Information Input Capacitor A 1µF or larger capacitor is typically recommended for CIN in most applications. A C IN capacitor is not required for basic operation; however, CIN is useful in preventing load transients from affecting upstream circuits. C IN should be located as close to the device VIN pin as practi- cally possible. Ceramic, tantalum, or aluminum electro - lytic capacitors may be selected for C IN. There is no specific capacitor ESR requirement for C IN; however, for higher current operation, ceramic capacitors are recom - mended for CIN due to their inherent capability over tan- talum capacitors to withstand input current surges from low impedance sources, such as batteries in portable devices. Output Capacitor For proper slew operation, a 0.1µF capacitor or greater between V OUT and GND is recommended. The output capacitor has no specific capacitor type or ESR require - ment. If desired, COUT may be increased without limit to accommodate any load transient condition without adversely affecting the device turn-on slew rate time. Enable Function The AAT4280A features an enable / disable function. This pin (ON/OFF) is compatible with both TTL or CMOS logic. Reverse Output-to-Input Voltage Conditions and Protection Under normal operating conditions, a parasitic diode exists between the output and input of the load switch. The input voltage should always remain greater than the output load voltage, maintaining a reverse bias on the internal para - sitic diode. Conditions where VOUT might exceed VIN should be avoided since this would forward bias the internal para- sitic diode and allow excessive current flow into the V OUT pin and possibly damage the load switch. In applications where there is a possibility of V OUT exceeding V IN for brief periods of time during normal operation, the use of a larger value C IN capacitor is highly recommended. A larger value of C IN with respect to COUT will effect a slower C IN decay rate during shut - down, thus preventing VOUT from exceeding VIN. In appli- cations where there is a greater danger of VOUT exceeding VIN for extended periods of time, it is recommended to place a Schottky diode from V IN to VOUT (connecting the cathode to V IN and anode to V OUT). The Schottky diode forward voltage should be less than 0.45V. Thermal Considerations and High Output Current Applications The AAT4280A is designed to deliver a continuous output load current. The limiting characteristic for maximum safe operating output load current is package power dis- sipation. In order to obtain high operating currents, careful device layout and circuit operating conditions need to be taken into account. The following discussions will assume the load switch is mounted on a printed circuit board utilizing the minimum recommended footprint, as stated in the Layout Considerations section of this datasheet. At any given ambient temperature (T A), the maximum package power dissipation can be determined by the fol- lowing equation: PD(MAX) [TJ(MAX) - TA] θJA Constants for the AAT4280A are maximum junction tem- perature, T J(MAX) = 125°C, and package thermal resis - tance, θJA = 120°C/W. Worst case conditions are calcu- lated at the maximum operating temperature where TA = 85°C. Typical conditions are calculated under normal ambient conditions where TA = 25°C. At TA = 85°C, PD(MAX) = 333mW. At TA = 25°C, PD(MAX) = 833mW. The maximum continuous output current for the AAT4280A is a function of the package power dissipation and the R DS of the MOSFET at T J(MAX). The maximum R DS of the MOSFET at T J(MAX) is calculated by increasing the maximum room temperature RDS by the RDS temperature coefficient. The temperature coefficient (T C) is 2800ppm/°C. Therefore, MAX RDS125°C = RDS25°C · (1 + TC · DT) MAX RDS125°C = 120mW · (1 + 0.0028 · For maximum current, refer to the following equation: IOUT(MAX) PD(MAX) RDS

Slew Rate Controlled Load Switch Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 202230A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • July 31, 2012 For example, if V IN = 5V, R DS(MAX) = 154m W and T A = 25°C, IOUT(MAX) = 2.3A. If the output load current were to exceed 2.3A or if the ambient temperature were to increase, the internal die temperature would increase and the device would be damaged. Higher peak currents can be obtained with the AAT4280A. To accomplish this, the device thermal resistance must be reduced by increasing the heat sink area or by oper - ating the load switch in a duty-cycle manner. High Peak Output Current Applications Some applications require the load switch to operate at a continuous nominal current level with short duration, high-current peaks. The duty cycle for both output cur - rent levels must be taken into account. To do so, first calculate the power dissipation at the nominal continu - ous current level, and then add in the additional power dissipation due to the short duration, high-current peak scaled by the duty factor. For example, a 4V system using an AAT4280A operates at a continuous 100mA load current level and has short 2A current peaks, as in a GSM application. The current peak occurs for 576µs out of a 4.61ms period. First, the current duty cycle is calculated: % Peak Duty Cycle: X/100 = 576µs/4.61ms % Peak Duty Cycle = 12.5% The load current is 100mA for 87.5% of the 4.61ms period and 2A for 12.5% of the period. Since the Electrical Characteristics do not report R DS(MAX) for 4V operation, it must be calculated approximately by con - sulting the chart of RDS(ON) vs. VIN. The RDS reported for 5V can be scaled by the ratio seen in the chart to derive the RDS for a 4V V IN: 120mW · 87m W /80mW = 130m W. De-rated for temperature: 130mW · (1 + 0.0028 · (125°C - 25°C)) = 166m W. The power dissipation for a 100mA load is calculated as follows: PD(MAX) = IOUT2 · RDS PD(100mA) = (100mA)2 · 166mW PD(100mA) = 1.66mW PD(87.5%D/C) = %DC · PD(100mA) PD(87.5%D/C) = 1.45mW The power dissipation for 100mA load at 87.5% duty cycle is 1.45mW. Now the power dissipation for the remaining 12.5% of the duty cycle at 2A is calculated: PD(MAX) = IOUT2 · RDS PD(2A) = (2A)2 · 166mW PD(2A) = 664mW PD(12.5%D/C) = %DC · PD(2A) PD(12.5%D/C) = 83mW The power dissipation for 2A load at 12.5% duty cycle is 83mW. Finally, the two power figures are summed to determine the total true power dissipation under the varied load: PD(total) = PD(100mA) + PD(2A) PD(total) = 1.45mW + 83mW PD(total) = 84.5mW The maximum power dissipation for the AAT4280A oper- ating at an ambient temperature of 85°C is 333mW. The device in this example will have a total power dissipation of 84.5mW. This is well within the thermal limits for safe operation of the device; in fact, at 85°C, the AAT4280A will handle a 2A pulse for up to 50% duty cycle. At lower ambient temperatures, the duty cycle can be further increased. Printed Circuit Board Layout Recommendations For proper thermal management and to take advantage of the low R DS(ON) of the AAT4280A, a few circuit board layout rules should be followed: VIN and V OUT should be routed using wider than normal traces, and GND should be connected to a ground plane. To maximize package thermal dispation and power handling capacity of the AAT4280A SC70JW-8 package, the ground plane area connected to the ground pins should be made as large as possible. For best performance, C IN and C OUT should be placed close to the package pins. Evaluation Board Layout The AAT4280A evaluation layout follows the printed cir - cuit board layout recommendations and can be used for good applications layout. Refer to Figures 1 through 3. Note: Board layout shown is not to scale.

Slew Rate Controlled Load Switch Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 202230A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • July 31, 2012

Ordering Information

Device Option Package Marking1 Part Number (Tape and Reel)2 AAT4280A-1 SC70JW-8 NDXYY AAT4280AIJS-1-T1 AAT4280A-2 SC70JW-8 NEXYY AAT4280AIJS-2-T1 AAT4280A-3 SC70JW-8 NFXYY AAT4280AIJS-3-T1 AAT4280A-4 SC70JW-8 3EXYY AAT4280AIJS-4-T1 AAT4280A-4 SOT23-6 3LXYY AAT4280AIGU-4-T1 AAT4280A-3 WLCSP-5 4PYW3 AAT4280AIUV-3-T1 Skyworks Green™ products are compliant with all applicable legislation and are halogen-free. For additional information, refer to Skyworks Definition of Green™, document number SQ04-0074.

Package Information

0.225 ± 0.075 0.45 ± 0.10 0.05 ± 0.05 2.10 ± 0.30 2.00 ± 0.20 7° ± 3° 4° ± 4° 0.15 ± 0.05

1.10 MAX

0.100 2.20 ± 0.20 0.048REF 0.50 BSC 0.50 BSC 0.50 BSC All dimensions in millimeters. 1. XYY = assembly and date code. 2. Sample stock is generally held for part numbers listed in BOLD. 3. YW = year code + week code.

Slew Rate Controlled Load Switch Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 202230A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • July 31, 2012 Copyright © 2012 Skyworks Solutions, Inc. All Rights Reserved. Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the information contained herein. Sky - works may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes. No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or information provided here- under, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions of Sale. THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS SHALL NOT BE LIABLE FOR ANY DAMAGES, IN - CLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury, death, physical or en- vironmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any damages resulting from such improper use or sale. Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of products outside of pub- lished parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters. Skyworks, the Skyworks symbol, and “Breakthrough Simplicity” are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands and names are for identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com, are incorporated by reference. SOT23-6

1.90 BSC

0.95 BSC

0.45 ± 0.15 0.10 BSC 2.85 ± 0.15 0.075 ± 0.075 0.40 ± 0.10 × 6 1.575 ± 0.125 1.20 ± 0.25 1.10 ± 0.20 2.80 ± 0.20 4° ± 4° 10° ± 5° 0.15 ± 0.07 GAUGE PLANE

0.60 REF

Slew Rate Controlled Load Switch Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 202230A • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • July 31, 2012 Copyright © 2012 Skyworks Solutions, Inc. All Rights Reserved. Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the information contained herein. Sky - works may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes. No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or information provided here- under, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions of Sale. THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS SHALL NOT BE LIABLE FOR ANY DAMAGES, IN - CLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury, death, physical or en- vironmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any damages resulting from such improper use or sale. Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of products outside of pub- lished parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters. Skyworks, the Skyworks symbol, and “Breakthrough Simplicity” are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands and names are for identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com, are incorporated by reference. WLSCP-5 0.725 ± 0.025

0.400 BSC

60° 0.945 ± 0.025

0.693 BSC

0.337 ± 0.025 0.120 ± 0.018 0.250 0.050 0.100 Line_1 Line_2 ø 0.1 (Ref.) Pin 1 indication Bottom View Top ViewSide View 0.457 ± 0.043 0.190 ± 0.029 End View All dimensions in millimeters.