1 POLE - TOGGLE

1 POLE - PUSH TO RESET

2 POLE - HANDLE

Carling Technologies, Inc.

60 Johnson Avenue • Plainville, CT 06062-1177

Phone: (860) 793-9281 • Fax: (860) 793-9231 Email: sales@carlingtech.com • www.carlingtech.com Well known for their proven reliability, the A-Series hydraulic/magnetic circuit breakers are compact, temperature stable and designed for precision operation in OEM markets requiring general purpose as well as full load amp applications. The A-Series circuit breakers are offered with ratings from 0.02 to 50 amps, up to 277VAC or 80VDC and are available with several choices of pole configurations, time delays, terminals, with a wide range of standard colors, imprinting and actuator styles. Actuator styles include handle for 1-6 poles and rocker for 1-3 pole construction. When front panel operation and aesthetics demand a clean, contemporary design, a two- color or solid color Visi-Rocker actuator, indicating either the ON mode or the TRIPPED/OFF mode, is ideally suitable. The new Rockerguard bezel and push-to-reset bezel, which help prevent inadvertent actuation, is also available. Features: Š Meets CSA Standard 22.2 No. 100 for the Generator & Welder markets Š Specially constructed version available for applications requiring CE markings Applications: Š Marine Š Telecommunications Š Military Š Renewable Energy Systems Š Generators & Welder Agency Certifications: Š UL Recognized – UL Standard 508, 1077, 1500 Š UL Listed – UL Standard 489A Š CSA Accepted Š TUV Certified Š VDE Certified

60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231

Email: sales@carlingtech.com • www.carlingtech.com 2 | RESISTANCE PER POLE VALUES from Line to Load Terminals (Values Based on Series Trip Circuit Breaker) A-Series Circuit Breaker - General Specifications Mechanical Physical Environmental Electrical Maximum Voltage Current Ratings Standard Voltage Coils Auxiliary Switch Rating Insulation Resistance Dielectric Strength Resistance, Impedance Pulse Tolerance Curves Number of Poles Internal Circuit Config. Weight Standard Colors Shock Vibration Moisture Resistance Salt Spray Thermal Shock Operating Temperature Ingress Protection Designed and tested in accordance with requirements of specification MIL-PRF-55629 & MIL-STD-202 as follows: 277VAC 50/60 Hz, 80VDC Standard current coils: 0.100, 0.250, 50.0. Other ratings available - consult ordering scheme. DC-6V, 12V; AC-120V, Other ratings available, consult ordering scheme. SPDT; 10.1 A - 250VAC, 1.0 A-65VDC/0.5 A - 80 VDC, 0.1A - 125VAC (with gold contacts). Minimum: 100 Megohms at 500 VDC UL, CSA - 1500V 60 Hz for one minute between all electrically isolated terminals. A-Series rocker circuit breakers comply with the 8mm spacing & 3750V dielectric requirements from hazardous voltage to operator accessible surfaces per EN 60950 and VDE 0805. Values from Line to Load Terminal - based on Series Trip Circuit Breaker. 1 - 6 Poles (handle) and 1-3 poles (rocker) at 30 Amps or less. Series, (with or without auxiliary switch), Shunt and Relay with current or voltage trip coils, Dual Coil, Switch Only with or without auxiliary switch. Approximately 65 grams/pole. (Approximately 2.32 ounces/pole) Housing - Black; Actuator- See Ordering Scheme. Withstands 100 Gs, 6ms, sawtooth while carrying rated current per Method 213, Test Condition “I”. Instantaneous and ultra-short curves tested @ 90% of rated current. Withstands 0.060” excursion from 10-

55 Hz, and 10 Gs 55-500 Hz, at rated

current per Method 204C, Test Condition A. Instantaneous and ultrashort curves tested at 90% of rated current. Method 106D; ten 24-hour cycles @ + 25°C to +65°C, 80-98% RH.56 days @ +85°C, 85% RH. Method 101, Condition A (90-95% RH @ 5% NaCl Solution, 96 hrs). Method 107D, Condition A (Five cycles @ -55°C to +25°C to +85°C to +25°C). -40°C to +85°C. For Sealed Toggle only. Meets MIL- PRF-55629 Requirements. ±15 PSI when installed in a panel. *Manufacturer reserves the right to change product specification without prior notice. Endurance 6,000 ON-OFF operations @ 6 per minute; with rated Current & Voltage. Additional 4,000 ON-OFF mechanical. Trip Free All A-Series Circuit Breakers will trip on overload, even when the actuator is forcibly held in the ON position. Trip Indication The operating actuator moves positively to the OFF position when an overload causes the circuit breaker to trip. When mid-trip handle is specified, the handle moves to the mid position on electrical trip of the circuit breaker. When mid-trip handle with alarm switch is specified, the handle moves to the mid position & the alarm switch actuates when the circuit breaker is electrically tripped.

Email: sales@carlingtech.com • www.carlingtech.com Email: sales@carlingtech.com • www.carlingtech.com | 3 Handle A-Series Circuit Breaker - General Specifications Electrical Tables Table A: Lists UL Recognized & CSA Accepted configurations and performance capabilities as a Component Supplementary Protector. Notes: 1 Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse (15A minimum) at no more than 4 times the rating of the protector. 2 Same as note 1, except that backup fuse is limited to 80 A maximum. 3 2 pole protector required (with one pole per power line) for: 125/250 VAC, 1 pole protector required for : 125 VAC, 1Ø Power System. 4 Meets the requirements of CSA 22.2 No. 100-04 - Motors and Generators.

Email: sales@carlingtech.com • www.carlingtech.com 4 | A-Series Circuit Breaker - General Specifications Electrical Tables Table B: Lists UL Recognized, CSA Accepted, VDE & TUV Certified configurations & performance capabilities as a Component Supplementary Protector. Notes: 1 General Purpose Ratings for UL/CSA Only. 2 Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse (15A minimum) at no more than 4 times the rating of the protector. 3 Same as note 2, except that backup fuse is limited to 80 A maximum. 4 Meets the requirements of CSA 22.2 No. 100-04 - Motors and Generators.

Email: sales@carlingtech.com • www.carlingtech.com Email: sales@carlingtech.com • www.carlingtech.com | 5 SERIES 14 1 DC --- 0.02 - 50 5000 TC1,OL1,U1 TC1,OL1,U1 32 1 DC --- 0.02 - 50 5000 TC1,OL1,U2 TC1,OL1,U2 65 DC --- 0.02 - 50 3000 TC1,OL1,U1 TC1,OL1,U1 1255 0 / 60 10 .02 - 50 3000 TC1,OL1,U2 TC1,OL1,U2 125 / 2505 0 / 60 1 2 0.02 - 50 3000 TC1,OL1,U2 TC1,OL1,U2 2505 0 / 60 10 .02 - 30 1500 TC1,OL1,U1 TC1,OL1,U1 Notes: 1A vailable with Special Catalog Number Only (consult factory) 22 pole protector required (with one per power line) for 125 / 250 VAC. 1 pole protector required for 125 VAC 1 phase power system CSA SHORT CIRCUIT CAPACITY (AMPS) APPLICATION CODES A-SERIES TABLE C: UL1500 (Marine Ignition Protected) UL VOLTAGE CIRCUIT CONFIGURATION CURRENT RATING FULL LOAD AMPS WITHOUT BACKUP FUSEMAX. RATING FREQUENCY PHASE A-Series Circuit Breaker - General Specifications Electrical Tables Table C: Lists UL Recognized, CSA Accepted configurations and performance capabilities as Protectors, Supplementary for Marine Electrical and Fuel Systems (Guide PEQZ2, File E75596). Ignition Protected per UL 1500. UL Classified Small Craft Electrical Devices, Marine in accordance with ISO 8846 (Guide UZMK, File MQ1515) as Marine Supplementary Protectors. Table D: Lists UL Listed configurations and performance capabilities as Circuit Breakers for use in Communications Equipment (Guide DITT, File E189195), under UL489A. Notes: 1 Available with special catalog number only (consult factory). 2 2 pole protector required (with one per power line) for 125 / 250 VAC. 1 pole protector required for 125 VAC 1 phase power system Notes:

1 Parallel Pole Construction

Component Recognition Program as Protectors Supplementary (Guide CCN/QVNU2, File E75596) Switches, Industrial Control (Guide CCN/NRNT2, File E148683) Protectors, Supplementary for Marine Electrical & Fuel Systems (Guide PEQZ2, File E75596) Ignition Protection Communications Equipment (Guide CCN/DITT, File E189195) Component Supplementary Protector under Class 3215 30, File 047848 0 000 CSA Standard C22.2 No. 235 EN60934, under License No. R72040875 EN60934, VDE 0642 under File No. 10537

Email: sales@carlingtech.com • www.carlingtech.com 6 | A-Series Handle UL Recognized – Ordering Scheme Series Actuator Poles Aux/Alarm Switch Frequency & Delay Current Rating Terminal Actuator Color Mounting/ Barriers Agency Approval Circuit A A B 1 13 0 B C10 450

1 SERIES

A

2 ACTUATOR1

A Handle, one per pole B Handle, one per multipole unit S Mid-Trip Handle, one per pole T Mid-Trip Handle, one per pole & Alarm Switch

8 TERMINAL9

110 Push-On 0.250 Tab (Q.C.)

2 Screw 8-32 w/upturned lugs

311 Screw 8-32 (Bus Type)

4 Screw 10-32 w/upturned lugs

511 Screw 10-32 (Bus Type)

6 Screw 8-32 w/upturned lugs

and 30° bend

7 Screw 8-32 (Bus Type) and

30° bend

8 Screw 10-32 w/upturned lugs

and 30° bend

9 Screw 10-32 (Bus Type) and

30° bend B Screw M5 w/upturned lugs C Screw M4 w/upturned lugs E11 Screw M4 (Bus Type) F Screw M5 w/upturned lugs and 30° bend G Screw M5 (Bus Type) and 30° bend H11 Screw M5 (Bus Type) L12 0.250 Q.C./ Solder Lug M11 M6 Threaded Stud Q14 Push-In Stud R Screw M4 w/upturned lugs and 30° bend T11 Screw M4 (Bus Type) and 30° bend P13 Printed Circuit Board Terminals S13 Push-On 0.110 Tab (Q.C.)

10 MOUNTING/BARRIERS

Threaded Insert, 2 per pole 1 6-32 x 0.195 inches no A 6-32 x 0.195 inches yes

2 ISO M3 x 5mm no

B ISO M3 x 5mm (multipole only) yes Front panel Snap-In, 0.75” wide bezel 5 without Handleguard no 6 without Handleguard (multipole only) yes Front panel Snap-In, 0.96” wide bezel 7 without Handleguard, 1-pole 0.96” wide; no multipole units have .105” bezel overhang on all sides 8 without Handleguard, 1-pole 0.96” wide; yes (multipole only) .105” bezel overhang on all sides

3 POLES

1 One

2 Two

3 Three

4 Four

5 Five

6 Six

5 AUXILIARY/ALARM SWITCH 5

(Gold Contacts) (Gold Contacts) (Gold Contacts)

6 FREQUENCY & DELAY

03 DC 50/60Hz, Switch Only

10 DC Instantaneous

11 DC Ultra Short

12 DC Short

14 DC Medium

16 DC Long

30 DC, 50/60Hz Instantaneous

31 DC, 50/60Hz Ultra Short

32 DC, 50/60Hz Short

34 DC, 50/60Hz Medium

36 DC, 50/60Hz Long

427 50/60Hz Short, Hi-Inrush 447 50/60Hz Medium, Hi-Inrush 467 50/60Hz Long, Hi-Inrush

527 DC, Short,Hi-Inrush

547 DC, Medium, Hi-Inrush

567 DC, Long, Hi-Inrush

7 CURRENT RATING (AMPERES)

OR VOLTAGE COIL (NORMAL RATED VOLTAGE)6 020 0.020 025 0.025 030 0.030 035 0.035 040 0.040 045 0.045 050 0.050 055 0.055 060 0.060 065 0.065 070 0.070 075 0.075 080 0.080 085 0.085 090 0.090 095 0.095 210 0.100 215 0.150 220 0.200 225 0.250 230 0.300 235 0.350 240 0.400 245 0.450 250 0.500 255 0.550 260 0.600 265 0.650 270 0.700 275 0.750 280 0.800 285 0.850 290 0.900 295 0.950 410 1.000 512 1.250 415 1.500 517 1.750 420 2.000 522 2.250 527 2.750 430 3.000 435 3.500 440 4.000 445 4.500 450 5.000 455 5.500 460 6.000 465 6.500 470 7.000 475 7.500 480 8.000 485 8.500 490 9.000 495 9.500 610 10.000 710 10.500 611 11.000 711 11.500 612 12.000 712 12.500 613 13.000 614 14.000 615 15.000 616 16.000 617 17.000 618 18.000 620 20.000 622 22.000 624 24.000 625 25.000 630 30.000 6358 35.000 6408 40.000 6458 45.000 6508 50.000 CODE AMPERES A06 6 DC A12 12 DC A18 18 DC A24 24 DC A32 32 DC A48 48 DC A65 65 DC J06 6 AC J12 12 AC J18 18 AC J24 24 AC J48 48 AC J65 65 AC K20 120 AC L40 240 AC CODE AMPERES

11 AGENCY APPROVAL

C UL Recognized & CSA Accepted D VDE Certified, UL Recognized & CSA Accepted E TUV Certified, UL Recognized & CSA Accepted I UL Rec. STD 1077, UL Rec. 1500 (ignition protected), & CSA Accepted

9 ACTUATOR COLOR & LEGEND

Acuator Color I-O ON-OFF Dual Legend Color White A B 1 Black Black C D 2 White Red F G 3 White Green H J 4 White Blue K L 5 White Yellow M N 6 Black Gray P Q 7 Black Orange R S 8 Black Black (short handle)15 T U 9 White Notes:

1 Actuator Code:

A: Handle tie pin spacer(s) and retainers provided unassembled with multi-pole units. B: Handle location as viewed from front of breaker: 2 pole - left pole 3 pole - center pole 4 pole - two handles at center poles 5 pole - three handles at center poles 6 pole - four handles at center poles S: Handle moves to mid-position only upon electrical trip of the breaker. Available with circuit codes B, C, D, E, F, G, H and K. T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the breaker. Available with circuit codes B & C.

2 Switch Only circuits, rated up to 50 amps and 6 poles, and only available when tied to a

protected pole (Circuit Code B, C, D or H.), For .02 to 30 amps, select Current Code 630. For 35 - 50 amps, select Current Code 650. 3 Available with terminal Codes 1, 2 and 3. Current Rating limited to 50A amps maximum. 4 Consult factory for available Dual Coil options, as special catalog number is required. With Shunt construction, Dual Coils will trip instantaneously on line voltage. Dual coils require 30VA minimum power to trip and are rated for intermittent duty only.

5 Auxiliary Switch breakers with Series Trip & Switch Only circuits: ≤ 30A - supplied with

standard half shells. 35-50A - supplied with extended boat (B-Style) half shells. On multi-pole breakers, one auxilary switch is supplied, mounted in the extreme right pole. 6 Separate pole type voltage coils not rated for continuous duty. Available only with delay codes 10 and 20. 7 Available with Circuit Codes B & D only. VDE Certified to 30 amps. UL Recognized, CSA Accepted & TUV Certified to 50 amps. 8 VDE Certification available with single pole breakers with DC Delay only. UL Recognition and CSA Accepted available in one and two pole breakers. 9 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal Codes 5, 9, G, H, M and Q..

10 Terminal Code 1: VDE Certification up to 25 amps and UL Recognition and CSA

Certification up to 30 amps, but not recommended over 20 amps.

11 Terminal Codes 3, 5, E and H (Bus Type) with VDE, are supplied with Lock Washers,

and Terminal Code M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers. These breakers are only VDE Certified when the washers are used. 12 Terminal Code L: VDE Certified available up to 12A. UL Recognized & CSA Accepted available up to 30A.

13 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30 amps

with VDE Certification and 50 amps with UL Recognition and CSA Accepted, with Circuit Codes A, B and C. Two pole breakers with Terminal Code P (Printed Circuit Board) are available up to 40 amps with UL Recognition and CSA Accepted with Circuit Codes A, B and C. 14 Terminal Code Q not available with VDE certification. 15 Single pole only.

4 CIRCUIT

A2 Switch Only (No Coil) B Series Trip (Current) C Series Trip (Voltage) D3 Shunt Trip (Current) E3 Shunt Trip (Voltage) F3 Relay Trip (Current) G3 Relay Trip (Voltage) H3,4 Dual Coil with Shunt Trip Voltage Coil K3,4 Dual Coil with Relay Trip Voltage Coil

Email: sales@carlingtech.com • www.carlingtech.com Email: sales@carlingtech.com • www.carlingtech.com | 7 A-Series Handle UL489A – Ordering Scheme Series Actuator Poles Aux/Alarm Switch Frequency & Delay Current Rating Terminal Actuator Color Mounting/ Barriers Max. Appl. Rating Agency Approval Circuit A A B 1 11 0 B M T14 450 A A Handle, one per pole S Mid-Trip Handle, one per pole T Mid-Trip Handle, one per pole & Alarm Switch

8 TERMINAL5

16 Push-On 0.250 Tab (Q.C.)

37 Screw 8-32 (Bus Type)

57 Screw 10-32 (Bus Type)

and 30° bend 30° bend and 30° bend 30° bend B Screw M5 w/upturned lugs F Screw M5 w/upturned lugs and 30° bend G Screw M5 (Bus Type) and 30° bend H Screw M5 (Bus Type) M7 M6 Threaded Stud P8 Printed Circuit Board Terminals Q9 Push-In Stud Threaded Insert, 2 per pole 1 6-32 x 0.195 inches no A 6-32 x 0.195 inches yes B ISO M3 x 5mm (multipole only) yes Front panel Snap-In, 0.75” wide bezel 5 without Handleguard no 6 without Handleguard (multipole only) yes Front panel Snap-In, 0.96” wide bezel 7 without Handleguard, 1-pole 0.96” wide; no multipole units have .105” bezel overhang on all sides 8 without Handleguard, 1-pole 0.96” wide; yes (multipole only) .105” bezel overhang on all sides

3 POLES2

5 AUXILIARY/ALARM SWITCH 2

(Gold Contacts)

523 DC, Short,Hi-Inrush

543 DC, Medium, Hi-Inrush

563 DC, Long, Hi-Inrush

210 0.100 215 0.150 220 0.200 225 0.250 230 0.300 235 0.350 240 0.400 245 0.450 250 0.500 255 0.550 260 0.600 265 0.650 270 0.700 275 0.750 280 0.800 285 0.850 290 0.900 295 0.950 410 1.000 512 1.250 415 1.500 517 1.750 420 2.000 522 2.250 527 2.750 430 3.000 435 3.500 440 4.000 445 4.500 450 5.000 455 5.500 460 6.000 465 6.500 470 7.000 475 7.500 480 8.000 485 8.500 490 9.000 495 9.500 610 10.000 710 10.500 611 11.000 711 11.500 612 12.000 712 12.500 613 13.000 614 14.000 615 15.000 616 16.000 617 17.000 618 18.000 620 20.000 622 22.000 624 24.000 625 25.000 630 30.000 6353 35.000 6403 40.000 6453 45.000 6503 50.000 CODE AMPERES

12 AGENCY APPROVAL

K UL489A LISTED, VDE CERTIFIED J UL489A LISTED, TUV CERTIFIED

11 MAXIMUM APPLICATION RATING

Acuator Color I-O Dual Legend Color White B 1 Black Black D 2 White Red G 3 White Green J 4 White Blue L 5 White Yellow N 6 Black Gray Q 7 Black Orange S 8 Black Black (short handle)10 U 9 White Notes: A: Handle tie pin spacer(s) and retainers provided unassembled with multi-pole units. S: Handle moves to mid-position only upon electrical trip of the breaker. T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the breaker. 2 On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole. 3 VDE Certified to 30 amps. UL489A Listed to 50 amps. 4 VDE Certification available with single pole breakers only. UL489A Listing available with one and two pole breakers. 5 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal Codes 5, 9 G, H, M and Q.

6 Terminal Code 1 (Push-On) available up to 25 amps with VDE Certification and 30 amps with

UL489A Listing, but is not recommended over 20 amps.

7 Terminal Codes 3, 5 and H (Bus Type) with VDE, are supplied with Lock Washers, and

Terminal Code M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers. These breakers are only VDE Certified when the washers are used.

8 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30 amps

with VDE Certification and 50 amps with UL489A Listing. 9 Terminal Code Q not available with VDE certification. 10 Single pole only. B Series Trip (Current)

Email: sales@carlingtech.com • www.carlingtech.com 8 | A-Series Handle WORLD – Ordering Scheme Series Actuator Poles Aux/Alarm Switch Frequency & Delay Current Rating Terminal Actuator Color Mounting/ Barriers Agency Approval Circuit A A B 1 13 0 A P14 450 A A Handle, one per pole B Handle, one per multi-pole unit S Mid-Trip Handle, one per pole T Mid-Trip Handle, one per pole & Alarm Switch 110 Push-On 0.250 Tab (Q.C.) and 30° bend 30° bend and 30° bend 30° bend B Screw M5 w/upturned lugs C Screw M4 w/upturned lugs E11 Screw M4 (Bus Type) F Screw M5 w/upturned lugs and 30° bend G Screw M5 (Bus Type) and 30° bend H11 Screw M5 (Bus Type) R Screw M4 w/upturned lugs and 30° bend T11 Screw M4 (Bus Type) and 30° bend Threaded Insert, 2 per pole 1 6-32 x 0.195 inches no A 6-32 x 0.195 inches yes B ISO M3 x 5mm (multipole only) yes Front panel Snap-In, 0.75” wide bezel 5 without Handleguard no 6 without Handleguard (multipole only) yes Front panel Snap-In, 0.96” wide bezel 7 without Handleguard, 1-pole 0.96” wide; no multipole units have .105” bezel overhang on all sides 8 without Handleguard, 1-pole 0.96” wide; yes (multipole only) .105” bezel overhang on all sides (Gold Contacts) 427 50/60Hz Short, Hi-Inrush 447 50/60Hz Medium, Hi-Inrush 467 50/60Hz Long, Hi-Inrush OR VOLTAGE COIL (NORMAL RATED VOLTAGE)6 210 0.100 215 0.150 220 0.200 225 0.250 230 0.300 235 0.350 240 0.400 245 0.450 250 0.500 255 0.550 260 0.600 265 0.650 270 0.700 275 0.750 280 0.800 285 0.850 290 0.900 295 0.950 410 1.000 512 1.250 415 1.500 517 1.750 420 2.000 522 2.250 527 2.750 430 3.000 435 3.500 440 4.000 445 4.500 450 5.000 455 5.500 460 6.000 465 6.500 470 7.000 475 7.500 480 8.000 485 8.500 490 9.000 495 9.500 610 10.000 710 10.500 611 11.000 711 11.500 612 12.000 712 12.500 613 13.000 614 14.000 615 15.000 616 16.000 617 17.000 618 18.000 620 20.000 622 22.000 624 24.000 625 25.000 630 30.000 6358 35.000 6408 40.000 6458 45.000 6508 50.000 CODE AMPERES A06 6 DC A12 12 DC A18 18 DC A24 24 DC A32 32 DC A48 48 DC A65 65 DC J06 6 AC J12 12 AC J18 18 AC J24 24 AC J48 48 AC J65 65 AC K20 120 AC L40 240 AC CODE AMPERES P TUV Certified, UL Recognized & CSA Accepted Q UL Rec. STD 1077, UL Rec. 1500 (ignition protected), & CSA Accepted Acuator Color I-O Dual Legend Color White A 1 Black Black C 2 White Red F 3 White Green H 4 White Blue K 5 White Yellow M 6 Black Gray P 7 Black Orange R 8 Black Notes: A: Handle tie pin spacer(s) and retainers provided unassembled with multi-pole units. S: Handle moves to mid-position only upon electrical trip of the breaker. Available with circuit codes B, C, D, E, and H. T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the breaker. Available with circuit codes B & C. protected pole (Circuit Code B, C, D or H.), For .01 to 30 amps, select Current Code 630. For 35 - 50 amps, select Current Code 650. 3 Available with terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum. 4 Consult factory for available Dual Coil options, as special catalog number is required. With Shunt construction, Dual Coils will trip instantaneously on line voltage. Dual coils require 30VA minimum power to trip and are rated for intermittent duty only. 5 On multi-pole breakers, one auxilary switch is supplied, mounted in the extreme right pole. 6 Separate pole type voltage coils not rated for continuous duty. Available only with delay codes 10, 20 & 30. 7 Available with Circuit Codes B & D only. VDE Certified to 30 amps. UL Recognized, CSA Accepted & TUV Certified to 50 amps. 8 Available up to two poles with AC or DC delays. 9 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal Codes 5, 9, G and H. 10 Terminal Code 1: TUV Certification up to 30 amps, but not recommended over 20 amps. 11 Terminal Codes 3, 5 , 7, 9, E, G and H (Bus Type) are supplied with Lock Washers. These breakers are only TUV Certified when the washers are used. A2 Switch Only (No Coil) B Series Trip (Current) C Series Trip (Voltage) D3 Shunt Trip (Current) E3 Shunt Trip (Voltage) H3,4 Dual Coil with Shunt Trip Voltage Coil

Email: sales@carlingtech.com • www.carlingtech.com Email: sales@carlingtech.com • www.carlingtech.com | 9 A-Series Rocker UL489A – Ordering Scheme Series Actuator Poles Aux/Alarm Switch Frequency & Delay Current Rating Terminal Actuator Color Mounting/ Barriers Max. Appl. Rating Agency Approval Circuit A F B 1 11 0 3 M T14 450 A 16 Push-On 0.250 Tab (Q.C.) and 30° bend 30° bend and 30° bend 30° bend B Screw M5 w/upturned lugs F Screw M5 w/upturned lugs and 30° bend G Screw M5 (Bus Type) and 30° bend H Screw M5 (Bus Type) M7 M6 Threaded Stud P8 Printed Circuit Board Terminals Q9 Push-In Stud

10 MOUNTING/BARRIERS11

STANDARD ROCKER BEZEL BARRIERS Threaded Insert, 2 per pole 1 6-32 x 0.195 inches no A 6-32 X 0.195 inches (multi-pole units only) yes B ISO M3 x 5mm (multi-pole units only) yes ROCKERGUARD & PUSH-TO-RESET BEZEL Threaded Insert, 2 per pole 3 6-32 x 0.195 inches no C 6-32 x 0.195 inches (multi-pole units only) yes

4 ISO M3 x 5mm no

D ISO M3 x 5mm (multi-pole units only) yes FRONT PANEL SNAP-IN BRACKET, 0.744” [18.90mm] wide bezel 8 without Rockerguard (single pole units only) no H with Rockerguard (single pole units only) no FRONT PANEL SNAP-IN BRACKET, 0.96” [24.48mm] wide bezel 9 without Rockerguard (single pole units only) no J with Rockerguard (single pole units only) no

1 One 2 Two 3 Three

5 AUXILIARY/ALARM SWITCH 3

(Gold Contacts)

52 DC, Short,Hi-Inrush

54 DC, Medium, Hi-Inrush

56 DC, Long, Hi-Inrush

210 0.100 215 0.150 220 0.200 225 0.250 230 0.300 235 0.350 240 0.400 245 0.450 250 0.500 255 0.550 260 0.600 265 0.650 270 0.700 275 0.750 280 0.800 285 0.850 290 0.900 295 0.950 410 1.000 512 1.250 415 1.500 517 1.750 420 2.000 522 2.250 527 2.750 430 3.000 435 3.500 440 4.000 445 4.500 450 5.000 455 5.500 460 6.000 465 6.500 470 7.000 475 7.500 480 8.000 485 8.500 490 9.000 495 9.500 610 10.000 710 10.500 611 11.000 711 11.500 612 12.000 712 12.500 613 13.000 614 14.000 615 15.000 616 16.000 617 17.000 618 18.000 620 20.000 622 22.000 624 24.000 625 25.000 630 30.000 6354 35.000 6404 40.000 6454 45.000 6504 50.000 CODE AMPERES K UL489A LISTED, VDE CERTIFIED J UL489A LISTED, TUV CERTIFIED Notes: 1 Push-To-Reset actuators have OFF portion of rocker shrouded. 2 Multi-pole breakers have all breakers identical except when specifying Aux. switch and/or mixed poles, and have one rocker per breaker. 3 Auxiliary Switch breakers with Series Trip circuits: ≤ 30A, are supplied with standard half shells. 30-50A are supplied with extended boat (B-Style) half shells. 4 VDE Certification available with single pole breakers only. UL489A Listing available with one and two pole breakers. 5 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal Codes 5, 9, G, H, M and Q.

6 Terminal Code 1 (Push-On) available up to 25 amps with TUV or VDE Certification and 30

amps with UL489A Listing, but is not recommended over 20 amps.

7 Terminal Codes 3, 5 and H (Bus Type) with TUV or VDE, are supplied with Lock Washers, and

Terminal Code M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers. These breakers are only TUV or VDE Certified when the washers are used. with VDE Certification and 50 amps with UL489A Listing. 9 Terminal Code Q not available with VDE certification. 10 Color shown is Visi and Legend with remainder of rocker black. Dual = ON-OFF/I-O legend. 11 Legend on Push-to-reset bezel/shroud is white with single color actuator codes R & U. Legend on Push-To-Reset bezel/shroud matches Visi-Color of rocker with actuator codes N & O. Rockerguard available with actuator codes C through K B Series Trip (Current) C Indicate ON, vertical legend D Indicate ON, horizontal legend F Indicate OFF, vertical legend G Indicate OFF, horizontal legend Single color J Vertical legend K Horizontal legend Push-To-Reset, Visi-Rocker N Indicate OFF, vertical legend O Indicate OFF, horizontal legend Push-To-Reset , Single color R Vertical legend U Horizontal legend Actuator or Marking: Marking Color Visi-Color10 ON-OFF Dual10 Single Color Visi-Rocker White B 1 Black White Black D 2 White n/a Red G 3 White Red Green J 4 White Green Blue L 5 White Blue Yellow N 6 Black Yellow Gray Q 7 Black Gray Orange S 8 Black Orange

Email: sales@carlingtech.com • www.carlingtech.com 10 | A-Series Handle – Circuit & Terminal Diagrams Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified.

Email: sales@carlingtech.com • www.carlingtech.com Email: sales@carlingtech.com • www.carlingtech.com | 11 A-Series Handle – Circuit & Terminal Diagrams Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 3 Alarm Switch available with .110 x .020 QC & solder lug terminals only.

Email: sales@carlingtech.com • www.carlingtech.com 12 | A-Series Handle – Form & Fit Drawings Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ± 0.20 [.51] unless otherwise specified. 3 For agency code P = .150 [3.81].

Email: sales@carlingtech.com • www.carlingtech.com Email: sales@carlingtech.com • www.carlingtech.com | 13 A-Series Handle – Front Panel Snap-In Mounting Style 5 Notes: 1 All dimensions are in inches [millimeters]. 3 Tolerance ±.020 [.51] unless otherwise specified.

Email: sales@carlingtech.com • www.carlingtech.com 14 | A-Series Handle – Front Panel Snap-In Mounting Style 7 Notes: 1 All dimensions are in inches [millimeters]. 3 Tolerance ±.020 [.51] unless otherwise specified.

Email: sales@carlingtech.com • www.carlingtech.com Email: sales@carlingtech.com • www.carlingtech.com | 15 A-Series Sealed Toggle UL Recognized – Ordering Scheme Series Actuator Poles Aux/Alarm Switch Frequency & Delay Current Rating Terminal Actuator Color Mounting/ Barriers Agency Approval Circuit A M B 1 11 0 0 C10 450 A M Sealed Toggle, one per unit

1 Standard Hex Nut no

A Standard Hex Nut (multipole only) yes 427 50/60Hz Short, Hi-Inrush 447 50/60Hz Medium, Hi-Inrush 467 50/60Hz Long, Hi-Inrush C UL Recognized & CSA Accepted I UL Recognized, CSA Accepted, UL1500 Ignition Protected

9 LEGEND PLATE

0 No legend plate

Notes:

1 Actuator Code M: Handle location as viewed from front of panel:

2 pole - right pole 3 pole - center pole 2 Switch Only circuits, rated up to 50 amps and 3 poles. Only available when tied to a protected pole. For .02 to 30 amps, select Current Code 630. For 35 - 50 amps, select Current Code 650. 3 Available with terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum. 4 Consult factory for available Dual Coil options, as special catalog number is required. With Shunt construction, Dual Coils will trip instantaneously on line voltage. Dual coils require 30VA minimum power to trip and are rated for intermittent duty only. 5 Auxiliary Switch available on Series Trip & Switch Only circuits, limited to 30 amps. On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole. 6 Voltage coils not rated for continuous duty. Available only with delay codes 10 and 20. 7 Available with Circuit Codes B & D only. VDE Certified to 30 amps. UL Recognized, CSA Accepted & TUV Certified to 50 amps. 8 UL Recognition and CSA Certification available on one and two pole breakers. 9 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal Codes 5, 9, G, H, M and Q..

10 Terminal Code 1: UL Recognition and CSA Certification up to 30 amps, but not recommended

over 20 amps. 11 Terminal Code L : available up to 30A.

12 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 50 amps,

with Circuit Codes A, B and C. Two pole breakers with Terminal Code P (Printed Circuit Board) are available up to 40 amps with Circuit Codes A, B and C. A2 Switch Only (No Coil) B Series Trip (Current) C Series Trip (Voltage) D3 Shunt Trip (Current) E3 Shunt Trip (Voltage) F3 Relay Trip (Current) G3 Relay Trip (Voltage) H3,4 Dual Coil with Shunt Trip Voltage Coil K3,4 Dual Coil with Relay Trip Voltage Coil (Gold Contacts) (Gold Contacts) (Gold Contacts) OR VOLTAGE COIL (NORMAL RATED VOLTAGE)6 020 0.020 025 0.025 030 0.030 035 0.035 040 0.040 045 0.045 050 0.050 055 0.055 060 0.060 065 0.065 070 0.070 075 0.075 080 0.080 085 0.085 090 0.090 095 0.095 210 0.100 215 0.150 220 0.200 225 0.250 230 0.300 235 0.350 240 0.400 245 0.450 250 0.500 255 0.550 260 0.600 265 0.650 270 0.700 275 0.750 280 0.800 285 0.850 290 0.900 295 0.950 410 1.000 512 1.250 415 1.500 517 1.750 420 2.000 522 2.250 527 2.750 430 3.000 435 3.500 440 4.000 445 4.500 450 5.000 455 5.500 460 6.000 465 6.500 470 7.000 475 7.500 480 8.000 485 8.500 490 9.000 495 9.500 610 10.000 710 10.500 611 11.000 711 11.500 612 12.000 712 12.500 613 13.000 614 14.000 615 15.000 616 16.000 617 17.000 618 18.000 620 20.000 622 22.000 624 24.000 625 25.000 630 30.000 6358 35.000 6408 40.000 6458 45.000 6508 50.000 CODE AMPERES A06 6 DC A12 12 DC A18 18 DC A24 24 DC A32 32 DC A48 48 DC A65 65 DC J06 6 AC J12 12 AC J18 18 AC J24 24 AC J48 48 AC J65 65 AC K20 120 AC L40 240 AC CODE AMPERES 110 Push-On 0.250 Tab (Q.C.) and 30° bend 30° bend and 30° bend 30° bend B Screw M5 w/upturned lugs C Screw M4 w/upturned lugs E11 Screw M4 (Bus Type) F Screw M5 w/upturned lugs and 30° bend G Screw M5 (Bus Type) and 30° bend H11 Screw M5 (Bus Type) L12 0.250 Q.C./ Solder Lug M11 M6 Threaded Stud Q14 Push-In Stud R Screw M4 w/upturned lugs and 30° bend T11 Screw M4 (Bus Type) and 30° bend P13 Printed Circuit Board Terminals S13 Push-On 0.110 Tab (Q.C.)

Email: sales@carlingtech.com • www.carlingtech.com 16 | A-Series Sealed Toggle – Form & Fit Drawings Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified.

Email: sales@carlingtech.com • www.carlingtech.com Email: sales@carlingtech.com • www.carlingtech.com | 17 A-Series Rocker UL Recognized – Ordering Scheme Series Actuator Poles Aux/Alarm Switch Frequency & Delay Current Rating Terminal Actuator Color Mounting/ Barriers Agency Approval Circuit A F B 2 11 0 3 D24 630 A C Indicate ON, vertical legend D Indicate ON, horizontal legend E Indicate ON, no legend F Indicate OFF, vertical legend G Indicate OFF, horizontal legend H Indicate OFF, no legend Push-To-Reset, Visi-Rocker N Indicate OFF, vertical legend O Indicate OFF, horizontal legend P Indicate OFF, no legend Single color J Vertical legend K Horizontal legend L No legend Push-To-Reset , Single color R Vertical legend U Horizontal legend V No legend

10 MOUNTING/BARRIERS20

STANDARD ROCKER BEZEL,Threaded Insert, 2 per pole BARRIERS 1 6-32 x 0.195 inches no A 6-32 X 0.195 inches (multi-pole units only) yes B ISO M3 x 5mm (multi-pole units only) yes ROCKERGUARD & PUSH-TO-RESET BEZEL,Threaded Insert, 2 per pole 3 6-32 x 0.195 inches no C 6-32 x 0.195 inches (multi-pole units only) yes D ISO M3 x 5mm (multi-pole units only) yes FRONT PANEL SNAP-IN BRACKET, 0.744” wide bezel 8 without Rockerguard (single pole units only) no H with Rockerguard (single pole units only) no FRONT PANEL SNAP-IN BRACKET, 0.96” wide bezel 9 without Rockerguard (single pole units only) no J with Rockerguard (single pole units only) no 429 50/60Hz Short, Hi-Inrush 449 50/60Hz Medium, Hi-Inrush 469 50/60Hz Long, Hi-Inrush

529 DC, Short,Hi-Inrush

549 DC, Medium, Hi-Inrush

569 DC, Long, Hi-Inrush

C UL Recognized & CSA Accepted D VDE Certified, UL Recognized & CSA Accepted E TUV Certified, UL Recognized & CSA Accepted I UL Rec. STD 1077, UL Rec. 1500 (ignition protected), & CSA Accepted Actuator or Marking: Marking Color Visi-Color12 I-O ON-OFF Dual12 Single Color Visi-Rocker White A B 1 Black White Black C D 2 White n/a Red F G 3 White Red Green H J 4 White Green Blue K L 5 White Blue Yellow M N 6 Black Yellow Gray P Q 7 Black Gray Orange R S 8 Black Orange Notes: 1 Push-To-Reset actuators have OFF portion of rocker shrouded. 2 Multi-pole breakers have all breakers identical except when specifying Aux. switch and/or mixed poles, and have one rocker per breaker.

3 Switch Only circuits, rated up to 50 amps & 3 poles, are available only when tied to a protected pole

(Circuit Code B, C, D or H.), For .02 to 30 amps, select Current Code 630. For 35 - 50 amps, select Current Code 650. 4 Available with terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum. 5 Consult factory for Dual Coil options, as special catalog number is required. With Shunt construction, Dual Coils will trip instantaneously on line voltage. Dual coils require 30VA minimum power to trip and are rated for intermittent duty only.

6 Auxiliary Switch breakers with Series Trip & Switch Only circuits: ≤ 30A, are supplied with standard

half shells. 30-50A are supplied with extended boat (B-Style) half shells. 7 On multi-pole breakers, one aux. switch is supplied, mounted in the extreme right pole. 8 Separate pole type voltage coils not rated for continuous duty. Available only with delay codes 10 and 20. 9 Available with Circuit Codes B & D only. VDE Certified to 30 amps. UL Recognized, CSA Accepted & TUV Certified to 50 amps. 10 Series Trip current ratings: VDE Certification available with single pole breakers with DC Delay only. UL Recognition & CSA Accepted available in one and two pole breakers. 11 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal Codes 5, 9, G, H, M and Q.

12 Terminal Code 1: VDE Certification up to 25 amps and UL Recognition and CSA Accepted up to 30

amps, but not recommended over 20 amps.

13 Terminal Codes 3, 5 E & H (Bus Type) with VDE, are supplied with Lock Washers; Terminal Code M

(M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers. These breakers are only VDE Certified when the washers are used. 14 VDE Cert. available up to 12 amps. UL Rec. & CSA Accepted available up to 30 amps. 15 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30 amps with VDE Certification and 50 amps with UL Recognition and CSA Accepted, with Circuit Codes A, B and C. Two pole breakers with Terminal Code P (Printed Circuit Board) are available up to 40 amps with UL Recognition and CSA Certification with Circuit Codes A, B and C. 16 Terminal Code Q not available with VDE. 17 Terminal Code S used on voltage coil circuit constructions only. 18 Color shown is visi and legend with remainder of rocker black. 19 Dual = ON-OFF/I-O legend with actuator. None = no legend on actuator 20 Legend on Push-to-reset bezel/shroud is white with single color actuator codes R, & U. Legend on Push-to-reset bezel/shroud matches Visi-color of rocker with actuator codes N & O. Rockerguard available with actuator codes C through L. A3 Switch Only (No Coil) B Series Trip (Current) C Series Trip (Voltage) D4 Shunt Trip (Current) E4 Shunt Trip (Voltage) F4 Relay Trip (Current) G4 Relay Trip (Voltage) H4,5 Dual Coil with Shunt Trip Voltage Coil K4,5 Dual Coil with Relay Trip Voltage Coil

5 AUXILIARY/ALARM SWITCH 6,7

(Gold Contacts) (Gold Contacts) (Gold Contacts) OR VOLTAGE COIL (NORMAL RATED VOLTAGE)8 020 0.020 025 0.025 030 0.030 035 0.035 040 0.040 045 0.045 050 0.050 055 0.055 060 0.060 065 0.065 070 0.070 075 0.075 080 0.080 085 0.085 090 0.090 095 0.095 210 0.100 215 0.150 220 0.200 225 0.250 230 0.300 235 0.350 240 0.400 245 0.450 250 0.500 255 0.550 260 0.600 265 0.650 270 0.700 275 0.750 280 0.800 285 0.850 290 0.900 295 0.950 410 1.000 512 1.250 415 1.500 517 1.750 420 2.000 522 2.250 527 2.750 430 3.000 435 3.500 440 4.000 445 4.500 450 5.000 455 5.500 460 6.000 465 6.500 470 7.000 475 7.500 480 8.000 485 8.500 490 9.000 495 9.500 610 10.000 710 10.500 611 11.000 711 11.500 612 12.000 712 12.500 613 13.000 614 14.000 615 15.000 616 16.000 617 17.000 618 18.000 620 20.000 622 22.000 624 24.000 625 25.000 630 30.000 63510 35.000 64010 40.000 64510 45.000 65010 50.000 CODE AMPERES A06 6 DC A12 12 DC A18 18 DC A24 24 DC A32 32 DC A48 48 DC A65 65 DC J06 6 AC J12 12 AC J18 18 AC J24 24 AC J48 48 AC J65 65 AC K20 120 AC L40 240 AC

8 TERMINAL11

112 Push-On 0.250 Tab (Q.C.)

313 Screw 8-32 (Bus Type)

513 Screw 10-32 (Bus Type)

and 30° bend 30° bend and 30° bend 30° bend B Screw M5 w/upturned lugs C Screw M4 w/upturned lugs E13 Screw M4 (Bus Type) F Screw M5 w/upturned lugs and 30° bend G Screw M5 (Bus Type) and 30° bend H13 Screw M5 (Bus Type) L14 0.250 Q.C./ Solder Lug M13 M6 Threaded Stud P15 Printed Circuit BoardTerminals Q16 Push-In Stud R Screw M4 w/upturned lugs and 30° bend S17 Push-On 0.110 Tab (Q.C.) T Screw M4 (Bus Type) and 30° bend

Email: sales@carlingtech.com • www.carlingtech.com 18 | A-Series Flat Rocker UL Recognized – Ordering Scheme Series Actuator Poles Aux/Alarm Switch Frequency & Delay Current Rating Terminal Actuator Color Mounting/ Barriers Agency Approval Circuit A 1 B 2 11 0 3 E24 630 A

1 Indicate OFF, vertical legend

2 Indicate OFF, horizontal legend

3 Vertical legend

4 Horizontal legend

Push-To-Reset, Visi-Rocker

5 Indicate OFF, vertical legend

6 Indicate OFF, horizontal legend

Push-To-Reset , Single color

7 Vertical legend

8 Horizontal legend

10 MOUNTING/BARRIERS18

STANDARD ROCKER BEZEL,Threaded Insert, 2 per pole BARRIERS FLAT ROCKER ACTUATOR 1 6-32 x 0.195 inches no A 6-32 X 0.195 inches (multi-pole units only) yes B ISO M3 x 5mm (multi-pole units only) yes RECESSED OFF SIDE ROCKER ACTUATOR19 5 6-32 x 0.195 inches no E 6-32 x 0.195 inches (multi-pole units only) yes

6 ISO M3 x 5mm no

F ISO M3 x 5mm (multi-pole units only) yes PUSH-TO-RESET BEZEL,Threaded Insert, 2 per pole 3 6-32 x 0.195 inches no C 6-32 x 0.195 inches (multi-pole units only) yes D ISO M3 x 5mm (multi-pole units only) yes

106 DC Instantaneous

429 50/60Hz Short, Hi-Inrush 449 50/60Hz Medium, Hi-Inrush 469 50/60Hz Long, Hi-Inrush C UL Recognized & CSA Accepted E TUV Certified, UL Recognized & CSA Accepted I UL Rec. STD 1077, UL Rec. 1500 (ignition protected), & CSA Accepted Actuator or Marking: Marking Color Visi-Color17 I-O ON-OFF Dual17 Single Color Visi-Rocker White A B 1 Black White Black C D 2 White n/a Red F G 3 White Red Green H J 4 White Green Blue K L 5 White Blue Yellow M N 6 Black Yellow Gray P Q 7 Black Gray Orange R S 8 Black Orange Notes: 1 Push-To-Reset actuators have OFF portion of rocker shrouded. 2 Multi-pole breakers have all breakers identical except when specifying Aux. switch and/or mixed poles, and have one rocker per breaker. 3 Switch Only circuits, rated up to 50 amps & 3 poles. Only available when tied to a protected pole. For .02 to 30 amps, select Current Code 630. For 35 - 50 amps, select Current Code 650. 4 Available with terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum. 5 Consult factory for Dual Coil options, as special catalog number is required. With Shunt construction, Dual Coils will trip instantaneously on line voltage. Dual coils require 30VA minimum power to trip and are rated for intermittent duty only. 6 Auxiliary Switch breakers with Series Trip & Switch Only circuits: ≤ 30A, are supplied with standard half shells. 30-50A are supplied with extended boat (B-Style) half shells. 7 On multi-pole breakers, one aux. switch is supplied, mounted in the extreme right pole. 8 Separate pole type voltage coils not rated for continuous duty. Available only with delay codes 10 & 20. 9 Available with Circuit Codes B & D only. UL Recognized, CSA Accepted & TUV Certified to 50 amps. 10 UL Recognition, CSA Acceptance & TUV Certification available in one and two pole breakers. 11 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal Codes 5, 9, G, H, M and Q. 12 Terminal Code 1: Available up to 30 amps, but not recommended over 20 amps.

13 Terminal Codes 3, 5 E & H (Bus Type) with TUV, are supplied with Lock Washers; Terminal Code M

(M6 Threaded Stud) with TUV is supplied with Lock and Flat Washers. These breakers are only TUV Certified when the washers are used. 14 TUV Cert. available up to 12 amps. UL Rec. & CSA Accepted available up to 30 amps.

15 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 50 amps with

UL Recognition, CSA Accepted & TUV Certification, with Circuit Codes A, B and C. Two pole breakers with Terminal Code P (Printed Circuit Board) are available up to 40 amps with UL Recognition and CSA Accepted with Circuit Codes A, B and C. 16 Terminal Code S used on voltage coil circuit constructions only. 17 Color shown is visi and legend with remainder of rocker black, Dual = ON-OFF/I-O legend. 18 Legend on Push-to-reset bezel/shroud is white with single color actuator codes 7 & 8. Legend on Push-To-Reset bezel/shroud matches Visi-Color of rocker with actuator codes 5 & 6. 19 Recessed “off-side” available with actuator codes 1, 2, 3 & 4. Legends on rocker are available in ink stamping only. A3 Switch Only (No Coil) B Series Trip (Current) C Series Trip (Voltage) D4 Shunt Trip (Current) E4 Shunt Trip (Voltage) F4 Relay Trip (Current) G4 Relay Trip (Voltage) H4,5 Dual Coil with Shunt Trip Voltage Coil K4,5 Dual Coil with Relay Trip Voltage Coil (Gold Contacts) (Gold Contacts) (Gold Contacts) OR VOLTAGE COIL (NORMAL RATED VOLTAGE)8 020 0.020 025 0.025 030 0.030 035 0.035 040 0.040 045 0.045 050 0.050 055 0.055 060 0.060 065 0.065 070 0.070 075 0.075 080 0.080 085 0.085 090 0.090 095 0.095 210 0.100 215 0.150 220 0.200 225 0.250 230 0.300 235 0.350 240 0.400 245 0.450 250 0.500 255 0.550 260 0.600 265 0.650 270 0.700 275 0.750 280 0.800 285 0.850 290 0.900 295 0.950 410 1.000 512 1.250 415 1.500 517 1.750 420 2.000 522 2.250 527 2.750 430 3.000 435 3.500 440 4.000 445 4.500 450 5.000 455 5.500 460 6.000 465 6.500 470 7.000 475 7.500 480 8.000 485 8.500 490 9.000 495 9.500 610 10.000 710 10.500 611 11.000 711 11.500 612 12.000 712 12.500 613 13.000 614 14.000 615 15.000 616 16.000 617 17.000 618 18.000 620 20.000 622 22.000 624 24.000 625 25.000 630 30.000 63510 35.000 64010 40.000 64510 45.000 65010 50.000 CODE AMPERES A06 6 DC A12 12 DC A18 18 DC A24 24 DC A32 32 DC A48 48 DC A65 65 DC J06 6 AC J12 12 AC J18 18 AC J24 24 AC J48 48 AC J65 65 AC K20 120 AC L40 240 AC 112 Push-On 0.250 Tab (Q.C.) and 30° bend 30° bend and 30° bend 30° bend B Screw M5 w/upturned lugs C Screw M4 w/upturned lugs E13 Screw M4 (Bus Type) F Screw M5 w/upturned lugs and 30° bend G Screw M5 (Bus Type) and 30° bend H13 Screw M5 (Bus Type) L14 0.250 Q.C./ Solder Lug M13 M6 Threaded Stud P15 Printed Circuit BoardTerminals Q Push-In Stud R Screw M4 w/upturned lugs and 30° bend S16 Push-On 0.110 Tab (Q.C.) T Screw M4 (Bus Type) and 30° bend

Email: sales@carlingtech.com • www.carlingtech.com Email: sales@carlingtech.com • www.carlingtech.com | 19 A-Series Flat Rocker UL 489A – Ordering Scheme Series Actuator Poles Aux/Alarm Switch Frequency & Delay Current Rating Terminal Actuator Color Mounting/ Barriers Max. Appl. Rating Agency Approval Circuit A 1 B 2 11 0 3 M T14 630 A 17 Push-On 0.250 Tab (Q.C.)

38 Screw 8-32 (Bus Type)

58 Screw 10-32 (Bus Type)

and 30° bend 30° bend and 30° bend 30° bend B Screw M5 w/upturned lugs F Screw M5 w/upturned lugs and 30° bend G Screw M5 (Bus Type) and 30° bend H8 Screw M5 (Bus Type) M8 M6 Threaded Stud P9 Printed Circuit Board Terminals Q10 Push-In Stud

10 MOUNTING/BARRIERS12

STANDARD ROCKER BEZEL,Threaded Insert, 2 per pole BARRIERS FLAT ROCKER ACTUATOR 1 6-32 x 0.195 inches no A 6-32 X 0.195 inches (multi-pole units only) yes B ISO M3 x 5mm (multi-pole units only) yes RECESSED OFF SIDE ROCKER ACTUATOR 13 5 6-32 x 0.195 inches no E 6-32 x 0.195 inches (multi-pole units only) yes F ISO M3 x 5mm (multi-pole units only) yes PUSH-TO-RESET BEZEL,Threaded Insert, 2 per pole 3 6-32 x 0.195 inches no C 6-32 x 0.195 inches (multi-pole units only) yes D ISO M3 x 5mm (multi-pole units only) yes (Gold Contacts) 210 0.100 215 0.150 220 0.200 225 0.250 230 0.300 235 0.350 240 0.400 245 0.450 250 0.500 255 0.550 260 0.600 265 0.650 270 0.700 275 0.750 280 0.800 285 0.850 290 0.900 295 0.950 410 1.000 512 1.250 415 1.500 517 1.750 420 2.000 522 2.250 527 2.750 430 3.000 435 3.500 440 4.000 445 4.500 450 5.000 455 5.500 460 6.000 465 6.500 470 7.000 475 7.500 480 8.000 485 8.500 490 9.000 495 9.500 610 10.000 710 10.500 611 11.000 711 11.500 612 12.000 712 12.500 613 13.000 614 14.000 615 15.000 616 16.000 617 17.000 618 18.000 620 20.000 622 22.000 624 24.000 625 25.000 630 30.000 6354 35.000 6404 40.000 6454 45.000 6504 50.000 CODE AMPERES J UL489A LISTED, TUV CERTIFIED Notes: 1 Push-To-Reset actuators have OFF portion of rocker shrouded. 2 Multi-pole breakers have all breakers identical except when specifying Aux. switch and/or mixed poles, and have one rocker per breaker. 3 Auxiliary Switch breakers with Series Trip circuits: ≤ 30A, are supplied with standard half shells. 30-50A are supplied with extended boat (B-Style) half shells. 4 VDE Certification available with single pole breakers only. UL489A Listing available with one and two pole breakers. 5 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal Codes 5, 9, G, H, M and Q. amps with UL489A Listing, but is not recommended over 20 amps. Terminal Code M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers. These breakers are only TUV or VDE Certified when the washers are used. with VDE Certification and 50 amps with UL489A Listing. 9 Terminal Code Q not available with VDE certification. 10 Color shown is Visi and Legend with remainder of rocker black. Dual = ON-OFF/I-O legend. 11 Legend on Push-to-reset bezel/shroud is white with single color actuator codes R & U. Legend on Push-To-Reset bezel/shroud matches Visi-Color of rocker with actuator codes N & O. Rockerguard available with actuator codes C through K B Series Trip (Current) C Indicate ON, vertical legend D Indicate ON, horizontal legend F Indicate OFF, vertical legend G Indicate OFF, horizontal legend Single color J Vertical legend K Horizontal legend Push-To-Reset, Visi-Rocker N Indicate OFF, vertical legend O Indicate OFF, horizontal legend Push-To-Reset , Single color R Vertical legend U Horizontal legend Actuator or Marking: Marking Color Visi-Color11 ON-OFF Dual11 Single Color Visi-Rocker White B 1 Black White Black D 2 White n/a Red G 3 White Red Green J 4 White Green Blue L 5 White Blue Yellow N 6 Black Yellow Gray Q 7 Black Gray Orange S 8 Black Orange

Email: sales@carlingtech.com • www.carlingtech.com 20 | A-Series Rocker – Circuit & Terminal Diagrams Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 3 Schematic shown represents current trip circuit. 4 Circuits shown for >30 amps / VDE.

Email: sales@carlingtech.com • www.carlingtech.com Email: sales@carlingtech.com • www.carlingtech.com | 21 A-Series Rocker – Form & Fit Drawings Notes: 1 Dimensions apply to all variations shown. Notice that circuit breaker line & load terminal orientation on indicate OFF is opposite of indicate ON. 2 For pole orientation with horizontal legend, rotate front view clockwise 90°. 3 All dimensions are in inches [millimeters]. 4 Tolerance ± 0.20 [.51] unless otherwise specified.

Email: sales@carlingtech.com • www.carlingtech.com 22 | A-Series Rocker Snap-In Bracket – Form & Fit Drawings Notes: 1 Dimensions apply to all variations shown. Notice that circuit breaker line & load terminal 2 For pole orientation with horizontal legend, rotate front view clockwise 90°. Orientation on indicate “OFF” is opposite of indicate “ON” 3 Recommended panel thickness: .04 0 [1.02] to .100 [2.54] 4 All dimensions are in Inches [millimeters]. 5 Tolerance ±.020 [.51] unless otherwise specified.

Email: sales@carlingtech.com • www.carlingtech.com Email: sales@carlingtech.com • www.carlingtech.com | 23 A-Series Flat Rocker – Form & Fit Drawings Notes: 1 All dimensions are in inches [millimeters]. 2 For pole orientation with horizontal legend, rotate front view clockwise 90°. 3 Tolerance ± 0.20 [.51] unless otherwise specified.

Email: sales@carlingtech.com • www.carlingtech.com 24 | REV_CB_A_0712 A-Series PC Terminal Diagrams Notes: 1 Drawing illustrates A-Series with VDE certification. 2 All dimensions are in inches [millimeters]. 3 Tolerance ± 0.20 [.51] unless otherwise specified