Rocker Switch with External Reset Function for High capacity Switching
- Energy-saving reset function triggered with external signals.
- Incorporates unique switching mechanism switching 20 A with excellent inrush-current durability.
- Double-pole, double-throw (DPDT) contact.
- Contact gap of 3 mm minimum.
- UL and cUL standard approved. Conforms to EN standards. ■List of Models ■Ratings Note: 1. The non-inductive lamp load has an inrush current 10 times steady current. 2. The inductive load has a power factor of 0.4 minimum (AC). 3. The motor load has an inrush current 6 times steady current. The above ratings were tested under the following conditions: 1. Ambient temperature: 20 ±2 °C 2. Ambient humidity: 65 ±5 %RH 3. Switching frequency: 7 times/min. Reset Coil Note: 1. Current must not flow for more than 10 s, otherwise the performance of the coil may be affected. 2. If a semiconductor element is used to control the reset coil, the residual voltage caused by leakage current must be 2.4 VDC max. RoHS Compliant Caution Refer to Precautions Contact Form DPDT Quantity per box Color of cases Black 50Cap color Black Model A8G-107-1-24 Rated load Non-inductive Inductive Resistive load Lamp load Inductive load Motor load
250 VAC 20A 10A 8A 8A
(operating voltage range) Reset voltage (coil temperature: 20°C±2°C) Rated energized current (coil temperature: 20°C±2°C) Coil resistance (coil temperature: 20°C±2°C) Permissible voltage applied period
24 VDC±10%
■Approved Standards UL, cUL (UL 1054/CSA C22.2 No.55) 20A 250 VAC KEMA (EN61058-1) 20(8)A 250 VAC ■Characteristics Note: For the codition in individual standard, contact your OMRON sales representative. Contact release time is the period of time during which contacts 1 and 2 and contacts 4 and 5 are released after voltage is imposed on the coil. ■Operation Permissible operating frequency Mechanical 20 operations/min max. Electrical Switching frequency: 7 times/min.; Coil operation: 7 times/min. Insulation resistance 100 MΩ min. (500 VDC) Dielectric strength Between terminals of the same polarity 2,000 VAC, 50/60 Hz, for 1 min Between terminals of the different polarity 2,000 VAC, 50/60 Hz, for 1 min Between charged metal parts and the ground terminal 4,000 VAC, 50/60 Hz, for 1 min Vibration resistance Malfunction 10 to 55 Hz, 1.5-mm double amplitude Shock resistance Malfunction 98 m/s2 (10G) Destruction 500 m/s2 (50G) max. Durability Mechanical Switching operation 100,000 times min. Electrical Switching operation 50,000 times min. Contact release time (see note) 100 ms max. Ambient operating temperature -10 to +55 °C (with no icing or condensation) Ambient operating humidity 45 to 85 %RH Item No excitation, load 1 turned off, and load 2 turned on No excitation, load 1 turned on, and load 2 turned off Excitation, load 1 turned off, and load 2 turned on Operation Circuit configuration Moving iron Iron core Reset springCoilPermanent magnet Manual operation The pernanent magnet keeps the moving iron and iron core in contact. The coil is exited and the moving iron is reset with the reset spring. Automatic reset 546 213 Load 2Load 1 Power supply 213 546 Load 1 Load 2 Power supply
24 VDC applied to coil terminal
■Dimensions (Unit: mm) Note: Unless otherwise specified, a tolerance of ±0.8 mm applies to all dimensions. ■Operating Characteristics ■Panel Cutout Note: Recommended panel material: SPCC Consult your OMRON representative when using a panel with a thickness other than the above. When processing the panel, be sure that the Play R is on the switch operation side. Be sure that the Edge is on the reverse side of panel when processing. ■Contact Form Note: When 24 VDC is applied to the coil, contacts 2 and 3 and contacts 5 and 6 are ON. #250 Quick connect terminal (t = 0.8) (Contact terminal) # 110 Quick connect terminal (t = 0.5) (Coil terminal) 22.5 34±0.3 11.1 11.1 20.8 23.6±0.3 19.5 8.6 A8G Operating force (OF) max. 19.6 N {2,000 gf} Panel thickness X Y 1.6 to 3.0 mm 34.4 mm 24.4 mm X Y +0.2 +0.3 Play R Edge 54 6 21 3 1 to 6:Contact terminals -, +: Coil terminals
■Precautions Be sure to read the Safety precautions common to all Rocker Switches for correct use. Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. Consult your OMRON representative before using the product under conditions which are not described in the manual or applying t he product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other sys tems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product p rovide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. OMRON Corporation ELECTRONIC AND MECHANICAL COMPONENTS COMPANY Contact: www.omron.com/ecb Cat. No. A106-E1-04 1212(0207)(O) Note: Do not use this document to operate the Unit.