A7CN OMRON | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 6
Technical content
- The series includes a complete range of locking-type models that prevent accidental operation.
Ordering Information
Switches (Single Switch Units) Note: 1. The classification diagrams show 4 Switch Units combined with End Caps to create 4-digit displays. 2. The model numbers given above are for Switch Units. Accessories (Order Separately) Use accessories, such as End Caps and Spacers, with the Switch Units. Note: The @ in the Spacer model number stands for a letter in the range A to U. (Refer to the table in the following explanation about Spa cers.) * The minimum order is for 10 End Caps. Model A7CN Classification (See note 1.) Screw mounting (back mounting) Snap-in (front mounting) Output code number Terminals PCB terminals Color Light gray Black Light gray Black 06 (binary coded decimal) --- A7CN-106-1 A7CN-206 A7CN-206-1 Model A7CN-L Classification (See note 1.) Snap-in (front mounting) Locking type Output code number Terminals PCB terminals Color Light gray Black 06 (binary coded decimal) A7CN-L206 A7CN-L206-1 Classification Screw mounting (back mounting) Snap-in (front mounting) Accessory Color Black Light gray Black End Caps (1 pair) A7CN-1M-1 * A7CN-2M * A7CN-2M-1 * Spacer A7CN-1P @-1 (See note.) A7CN-2P @ (See note.) A7CN-2P @-1 (See note.)
End Caps are used on the Switch Units at each end and allow all the Switch Units to be securely mounted to a panel. They come in pairs, one for the left and one for the right. Spacers
- Spacers are used for creating extra space or gaps between the Switch Units and have the same dimensions as the Switch Units themselves.
- There are also Spacers with engraved characters or symbols that can be used for indicating units, such as time and length. (Refer to the following table.) Consult your OMRON representative for details. Specifications Symbol A B C D E F G Stamp No desig- nation SEC MIN H g kg mm Symbol H J K L Q T U Stamp cm m °CP C S x10 SEC 0 Switching capacity (resistive load) 5 to 28 VDC 1 mA to 0.1 A Continuous carry current 1A Contact resistance 200 mΩ max. Insulation resistance Between non-connected terminals 10 MΩ min. (at 250 VDC) Between terminal and non-current carrying part 100 MΩ min. (at 500 VDC) Dielectric strength Between non-connected terminals 200 VAC, 50/60 Hz for 1 min Between terminal and non-current carrying part 1,000 VAC, 50/60 Hz for 1 min Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude Shock resistance 490m/s2 min. Durability Mechanical 30,000 operations min. Electrical 20,000 operations min. Ambient temperature Operating: -10°C to 65°C (with no icing) Storage: -20 °C to 80°C Ambient humidity Operating: 35% to 85% Max. operating force 4.41 N max.
Dimensions (Unit: mm) Switches C 2.4 0.3 P=6±0.2 *5.43 A * Terminal position dimensions 18 16 2.8 6±0.1 A C B 0.6±0.2 PCB terminal P=2.54 ±0.2 1611.6 2 4.6 2 15.7 3.5 A+0.7 B 16.2+0.5 Panel thickness: 2 Tow, M2.5 or M2.6 Note: 1. The dimensions above include both End Caps, and will increase 6 mm for each Spacer inserted. 2. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. The tolerance for multiple connection is ±(number of units x 0.4) mm. Number of Switches (n) Size A (n x 6 + 6) Size B (n x 6 + 11) Size C (n x 6 + 16) 1 1 21 72 2 2 1 82 32 8 3 2 42 93 4 4 3 03 54 0 5 3 64 14 6 6 4 24 75 2 7 4 85 35 8 8 5 45 96 4 9 6 06 57 0 10 66 71 76 A7CN-106-1 PCB Terminals Note: Common terminal C is at the bottom when the Switch Unit is viewed from the front. Panel Cutout C 5.4 * B+0.7 16.2+0.6 2.4 0.3P=63 B 6±0.14 A 0.6±0.1 P=2.54 ±0.2 1611.6 2 4.9 2.2 15.5 3.5 PCB terminal Panel thickness: 1 to 2 * Terminal position dimensions ±0.2 Note: 1. The dimensions above include both End Caps, and will increase 6 mm for each Spacer inserted. 2. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. The tolerance for multiple connection is ±(number of units x 0.4) mm. Number of Switches (n) Size A (n x 6 + 8) Size B (n x 6 + 6) 11 4 1 2 22 0 1 8 32 6 2 4 43 2 3 0 53 8 3 6 64 4 4 2 75 0 4 8 85 6 5 4 96 2 6 0 10 68 66 A7CN-206(-1) PCB Terminals Note: Common terminal C is at the bottom when the Switch Unit is viewed from the front. Panel Cutout C B+0.7 16.2+0.6 2.4 0.3 P=6±0.2 5.43 B 6±0.14 A 0.6 ±0.2 P=2.54 ±0.2 1611.6 1.9 2.2 15.54.7 3.5 PCB terminal Panel thickness: 1 to 2 When setting * Terminal position dimensions Note: 1. The dimensions above include both End Caps, and will increase 6 mm for each Spacer inserted. 2. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. The tolerance for multiple connection is ±(number of units x 0.4) mm. Number of Switches (n) Size A (n x 6 + 8) Size B (n x 6 + 6) 11 4 1 2 22 0 1 8 32 6 2 4 43 2 3 0 53 8 3 6 64 4 4 2 75 0 4 8 85 6 5 4 96 2 6 0 10 68 66 A7CN-L206(-1) PCB Terminals Locking Model Note: Common terminal C is at the bottom when the Switch Unit is viewed from the front. Panel Cutout
Accessories (Order Separately) Note: Unless otherwise indicated, dimensional tole rances for dimensions in the models above are ±0.4mm. Output Codes 06 (Binary Code) Note: The solid dot ● indicates that the internal switch is ON (i.e., connected to the common terminal). Ordering Procedure Place orders as shown in the example below, specifying the model and number. Standard products are not factory-assembled for shipment. Contact your OMRON representative for details on ordering factory-assembled sets. 1. Switch Unit (snap-in mounting, black) A7CN-206-1: 4 pieces 2. Spacer (snap-in mounti ng, no designation, black) A7CN-2PA-1: 1 piece 3. End Caps (snap-in mounting, black) A7CN-2M-1: 1 pair End Caps for Push-operated Switches A7CN-1M-1 Screw Mounting Left Side Right Side 16±0.2 3±0.1 16 3 2 2 13.615.7 13.6 15.7 16 ±0.2 188 3±0.1 2.2 16 3±0.12.7 2 44 3±0.1 2.7 2.2 2.215.5 13.4 15.513.4 End Caps for Push-operated Switches A7CN-2M(-1) Snap-in Mounting Left Side Right Side 6±0.1 11.65 Spacers for Push-operated Switches A7CN-1P@-1 Screw Panel Mounting Model Note: The @ in the Spacer model number stands for a letter in the range A to U. (Refer to the table under the explanation about Spacers on page 3.) Spacers for Push-operated Switches A7CN-2P@(-1) Snap-in Mounting Model Note: The @ in the Spacer model number stands for a letter in the range A to U. (Refer to the table under the explanation about Spacers on page 3.) 6±0.1 13.4 2.25 16±0.2 Dial Terminals connected to common 1 2 4 8 1 ● 2 ● 3 ●● 4 ● 5 ●● 6 ●● 7 ●●● 8 ● 9 ●● 3 2 311
Refer to Precautions for Correct Use on in the Technical Guide for Thumbwheel Switches. Environment
- Do not use where gases are generated (ammonia, chlorine, sulfur dioxide).
- Although Switches are of nearly dust-proof construction, they are not drip-proof, therefore do not use in areas subject to water or oil exposure and do not operate with wet or oily hands.
- Provide additional dust-proofing measures, such as using a dust- proof cover, when using in sand-exposed areas. Handling
- The A7CN cannot be connected to the A7C.
- The molded components of the Switch use polyacetal resin and polycarbonate resin. It is recommended that alcohol is used to wipe off dirt and smudges from the molded components. Take care to prevent the alcohol from getting inside. Do not use thinner or other solutions which might damage the resin.
- When changing settings, do not touch the operating buttons if your fingers are wet or there is oil or any other foreign substance on your fingers.
- Do not drop the individual Switches. Doing so may damage the resin catch (for connecting) on the side of the Switch.
- When separating Switches, use a screwdriver as shown in the figure below; disconnect them by releasing the top and bottom hooks. Be careful not to bend the hooks.
- When connecting Switches, fit the mating parts together.
- Do not push the (+) and (-) operating push-buttons at the same time. Models with PCB Terminals Do not use excessive force in handling the Switches. In particular, take care to avoid dropping them because the terminals might bend or break. Screw-mounting Models Tighten mounting screws to a torque between 0.2 to 0.24 N·m, using M2.6 screws. Use plain washers or spring washers together with the screws. Setting Numbers Locking Type
- Set with the setting button by raising it.
- Return the button to its original position after setting. It is then locked to prevent rotation, and the set numbers will not change accidentally. Soldering Note the following points when soldering printed circuit boards:
- The terminal insertion holes on the PCB must be at least 1 mm in diameter.
- Automatic Soldering Do not use dip cleaning. Doing so may result in flux penetration of the Switch interior, causing contact and rotational defects. Clean the flux as shown in Figure 1, tilting the Switch 80° or less and using a brush to apply the solvent only to the back of the board. It may also be cleaned by dipping only the back of the board into the solvent and then using a brush to clean.
- Dip Soldering When applying flux solvent, the dipping time is a maximum of 2 seconds. As shown in Figure 2, avoid flooding the top surface of the printed circuit board with flux. Using a brush to apply flux further reduces the danger of flux penetration. When cleaning flux with a brush, tilt the Switch 80° or less, as shown in Figure 1, in order to prevent flux from flowing onto the switch mounting surface. Clean flux as described above under Automatic Soldering.
- Using a Soldering Iron Use a 30-W soldering iron at a temperature of 350°C for a maximum of 3 seconds, and flush as described above. Do not apply force to the terminals during soldering and for 3 minutes after soldering is completed. Doing so may result in conduction or operation failure.
- Ensure that soldering flux and alcohol do not penetrate into the Switch interior Precautions for Correct Use Do not push here Top surface of board 80° or less Back surface of board Wipe away flux with a brush. Figure 1 Figure 2
Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
- Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
- Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations.
- Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2008.12 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2008 All Right Reserved.