Thumbwheel Switch A7 /C0106 A Wide Selection of Models: Thumbwheel- or Push-operated, Decimal or Hexadecimal A wide selection ranging from miniature models that save space to large models with enhanced readability and operability. Select models with the specifications desired, or where long life and reliability are critical. Additional new models prevent value changes due to accidental pressing of buttons. Pen-push or locking types are available.

Ordering Information

Terminals Color Output code mounting 03 (decimal code) (binary coded decimal) (binary coded decimal with component adding provision) (decimal code with component adding provision) (binary coded hexadecimal) (binary coded hexadecimal with component adding provision) A7DP-2 (pen-push) Si PCB terminal Light gray (p p ) Snap-in Black A7DP-206-1 A7D-2 Snap-in PCB terminal Light gray p Black A7D-206-1 A7D-1 Screw ti PCB terminal Light gray mounting Black A7D-106-1 A7CN Screw ti PCB terminal Light gray mounting Black A7CN-106-1 A7CN Snap-in PCB terminal Light gray p Black A7CN-206-1 A7CNL (Locking) Si PCB terminal Light gray (g ) Snap-in Black A7CN-L206-1 A7BL (locking) Snap-in Solder terminal (see note Light gray Snap-in (see note 1) Black A7BL-206-1 A7BL-207-1 A7BS Snap-in Solder terminal (see note Light gray (A7BS-203) A7BS-206 A7BS-207 (A7BS-219) A7BS-254 A7BS-255 (see note 1) Black (A7BS-203-1) A7BS-206-1 A7BS-207-1 (A7BS-219-1) A7BS-254-1 A7BS-255-1

Output codeColorTerminalsModel and mounting 55 (binary coded hexadecimal with component adding provision) (binary coded hexadecimal) (decimal code with component adding provision) (binary coded decimal with component adding provision) (binary coded decimal) (decimal code) A7BS- 20/C0106-S (with external Solder terminal (see note Light gray external Stoppers) Snap-in (see note 1) Black A7BS-206-S- A7BS-207-S- A7PS Snap-in Solder terminal (see note Light gray A7PS-203 A7PS-206 A7PS-207 A7PS-219 A7PS-254 A7PS-255 (see note 1) Black A7PS-203-1 A7PS-206-1 A7PS-207-1 A7PS-219-1 A7PS-254-1 A7PS-255-1 A7PH (long life) Snap-in Solder terminal (see note Light gray A7PH-203 A7PH-206 A7PH-207 A7PH-219 --- --- Snap-in (see note 1) Black A7PH-203-1 A7PH-206-1 A7PH-207-1 A7PH-219-1 Note: 1. Terminals for use with PCBs are also available. Inquire for details. 2. Please inquire about Code 01 models with +, – displays (-PM) and models in parentheses. Accessories (Order Separately) Applicable Switch Ui t Color End Caps Spacers (see note 1) Connectorspp Unit Solder terminals PCB terminals A7D-1 Light gray A7D-1M A7D-1PA --- --- Black A7D-1M-1 A7D-1PA-1 A7DP-2/A7D-2 Light gray A7D-2M A7D-2PA --- --- Black A7D-2M-1 A7D-2PA-1 A7CN St i Light gray --- --- --- --- Screw mounting Black A7CN-1M-1 A7CN-1P/C0106-1 A7CN/A7CN-L Si Light gray A7CN-2M A7CN-2P/C0106 --- --- Snap-in Black A7CN-2M-1 A7CN-2P/C0106-1 A7BL/A7BS/ A7BS-20/C0106-S (see Light gray A7B-M A7B-PA A7B-C A7B-CP A7BS-20/C0106-S (see note 2) Black A7B-M-1 A7B-PA-1 A7PS Light gray A7P-M A7P-PA --- --- Black A7P-M-1 A7P-PA-1 A7PH Light gray A7P-M A7P-PA --- --- Black A7P-M-1 A7P-PA-1 Note: 1. Spacers come standard without characters. Refer to page 30 for characters to be included. 2. Stopper pin comes standard. Model: A7BS-S (Stopper pins come in pairs. They are shipped free initially. Please make special arrangements for maintenance.)

Terminals Color Output code mounting 01 (binary code with +, – displayed) (decimal code) (binary coded decimal) (binary coded decimal with component adding provision) A7MD/ A7MD-/C0106/C0106-D (see note 1) PCB terminal Black --- --- A7MD-106-P-09 --- (see note 1) Fastens to panel via printed circuit board. A7MD-106-P-09-D (see note 1) A7MA-1 Screw mounting Solder terminal Black (A7MA-106-PM) (A7MA-103) A7MA-106 A7MA-107 g PCB terminal (A7MA-P2-PM) A7MA-106-P2 A7MA-107-P2 A7MA-2 Snap-in Solder terminal Light gray (A7MA-206-PM) --- A7MA-206 A7MA-207 p Black (A7MA-206-PM-1) A7MA-206-1 A7MA-207-1 PCB terminal Light gray (A7MA-206-P2-PM) A7MA-206-P2 A7MA-207-P2 Black (A7MA-206-P2- PM-1) A7MA-206-P2-1 A7MA-207-P2-1 A7SS Screw mounting Solder terminal Black (A7SS-106-PM) A7SS-103 A7SS-106 A7SS-107 A7AS Snap-in Solder terminal Light gray (A7AS-206-PM) A7AS-203 A7AS-206 A7AS-207 p Black (A7AS-206-PM-1) A7AS-203-1 A7AS-206-1 A7AS-207-1 Note: 1. Indicates models with built-in diodes. 2. Please inquire about models in parentheses. Model and ti Terminals Color Output code mounting 08 (06 + 22) (double-side d PCB version of 06) (06 with odd parity) (decimal code with component adding provision) (06 with complement ary code) (double-side d PCB verstion of 07) A7SS Screw mounting Solder terminal A7AS Snap-in Solder terminal Light gray p Black A7AS-219-1 (A7AS-222-1) Note: Inquire about models in parentheses. Accessories (Order Separately) Applicable Switch Ui t Color End Caps (left-right Spacers (see note 2) Connectorspp Unit p( g set) Solder terminal PCB terminal A7MD(-D) Black A7MD-1M A7MD-PA --- --- A7MA-1 Black A7M-1M A7M-1PA --- --- A7MA-2 Light gray A7M-2M A7M-2PA --- --- Black A7M-2M-1 A7M-2PA-1 A7SS Black A7SS-M --- --- --- A7AS Light gray A7AS-M --- --- --- Black A7AS-M-1 --- Note: 1. Spacers serve the same purpose as spare Switch Units, except that their widths differ. Refer to page 30 , Dimensions, for further information. 2. Spacers come standard without characters. Refer to page 30 for characters to be included.

The Thumbwheel Switch is generally used in the configuration shown below. 1: Switch Unit refers to the Switch itself. As each digit is independent of the others, a number of Switch Units are assembled to make up just the number of digits needed. 2: Spacers can be used in case the number of digits change due to a change in specifications. When units for time and length must be displayed, the necessary letters and symbols can be printed or stamped. The stamping shown in the following table can be produced. Inquire for details. Stamping Symbol A B C D E F G Stamp No desig- nation SEC MIN H g kg mm Symbol H J K L Q T U Stamp cm m °C PCS x 10 SEC 0 /C0083 3, 4: End Caps/Side Plates: These are used at both ends of the Switch Unit to insure a solid mount of each Switch Unit to a panel. Left and right plates make a set. 5: Connectors: Since the Switch Unit snaps right into a Connector, accomplishing both attachment and wiring in a single action, connections, maintenance and inspection are greatly simplified. Ordering Standard products such as the Switch Units and End Caps are not factory-assembled for shipment. Place orders as shown below, specifying the model and number of Switch Units. Ordering Example: Figure Product name Model Number of Units

1 Switch Unit A7BS-206-1 2

2 Spare Unit A7B-PA-1 1

3 Attachment Board A7B-M-1 1 set

5 Connector A7B-CP 2

Special Characters and Symbols for Dial Displays Dials can be ordered with special characters or symbols as well as with Stoppers attached. Ask your OMRON sales representatives. Positive, Negative Dials To order dials marked with +, –, +, –, ... in place of the numerals 0 to 9, add the suffix -PM to the model number. (Refer to page 18 for de- tails) Example: A7PS-203-PM Attaching Stoppers Stoppers are used to limit the display range from 0 to 9 down to 0 to 5, for example. Add -S/C0106/C0106 to the suffix, specifying the range in the blanks. Example: A7PS-203-S05 Units to which Stoppers can be attached are the A7DP, A7D, A7BL, A7PS, A7PH, A7SS, and A7AS. On the outside of the A7BS-/C0106-S is a Stopper Pin with which the user can make any setting. The A7CN-2, A7CN-1, A7CN-L, A7MD, and A7MA cannot be equipped with Stoppers.

/A7D-2 A7CN/A7CN-L A7BL/A7BS /A7BS-20/C0106-S A7PS A7PH Switching capacity (resistive load) 5 to 30 VDC 1 mA to 0.1 A 5 to 28 VDC 1 mA to 0.1 A

125 VAC/28 VDC

10 µA to 0.15 A Continuous carry current 100 mA 1 A max. 3 A max. Contact resistance 200 mΩ max. Insulation resistance Between non-connected terminals 10 MΩ min. (at 250 VDC) 10 MΩ min. (at 500 VDC) 100 MΩ min. (at

500 VDC)

100 MΩ min. (at 500 VDC) 1,000 MΩ min. (at 500 VDC) Dielectric strength Between non-connected terminals

250 VAC,

200 VAC,

600 VAC, 50/60 Hz for 1 min

1,000 VAC, 50/60 Hz for 1 min Vibration resistance Malfunction 10 to 55 Hz, 1.5-mm double amplitude Shock resistance Malfunction 500 m/s2 min. (approx. 50G) 490 m/s2 min. (approx. 50G) 500 m/s2 min. (approx. 50G) Life expectancy Mechanical 30,000 operations min. 100,000 operations min. 2,000,000 operations min. Electrical 20,000 operations min. 50,000 operations min. 1,000,000 operations min. Ambient temperature (with no icing) Operating: –10° C to 70°C Storage: –20° C to 80°C Operating: –10 °C to 65°C Storage: –20 °C to 80°C Ambient humidity Operating: 45% to 85% Operating: 35% to 85% Operating: 45% to 85%

Item A7MD/A7MD-/C0106/C0106-D (see note 1) A7MA-1/A7MA-2 A7SS A7AS Switching capacity (resistive load) 5 to 28 VDC 1 mA to 0.1 A

50 VAC to 28 VDC

1 mA to 0.1 A Continuous carry current 1 A max. Contact resistance 200 mΩ max., 10 Ω max. (see note 2) 200 mΩ max. Insulation resistance (see note 1) Between non-connected terminals 10 MΩ min. (at 500 VDC) Between terminal and non-current carrying part 1,000 MΩ min. (at 500 VDC) Dielectric strength (see note 1) Between non-connected terminals

200 VAC, 50/60 Hz for 1 min 600 VAC, 50/60 Hz for 1 min

1,000 VAC, 50/60 Hz for 1 min Vibration resistance Malfunction 10 to 55 Hz, 1.5-mm double amplitude Shock resistance Malfunction 200 m/s2 min. (approx. 20G) 490 m/s2 min. (approx. 50G) Life t Mechanical 30,000 operations min. 1,000,000 operations min. expectancy Electrical 20,000 operations min. 50,000 operations min. Ambient temperature (with no icing) Operating: –10 °C to 65°C Storage: –20 °C to 80°C Operating: –40 °C to 85°C Storage: –40 °C to 85°C Ambient humidity Operating: 45% to 85% Max. operating force max. 2.95 N (300 gf) 3.9 N (400 gf) Note: 1. For A7MD(-D) with diode, the dielectric strength was measured at display of “0.” Operation Output Codes Output code types are distinguished according to terminal numbers on Switch Units. How to Read Output Codes Example for Output Code 06 For example, when the dial position is “3,” the common terminal C on the Switch Unit is connected to terminals 1 and 2, as indicated by the solid dots in the output code table. The internal circuitry is shown below. Switch Reference The internal circuit with diodes for the A7MD-106-P-09 is shown here, but the output condition and concepts are the same as those to the left. Diode Switch

When a Switch is inserted into a Connector, e.g., for the A7BS, the common terminal C becomes connector terminal 2, and terminals 1 and 2 become connector terminals 4 and 5, respectively. 06: Binary-coded Decimal Output, Single-sided Board Thumbwheel Switch Unit Terminal numbers Connector Model A7BS Dial Switch Unit or Connector Common terminal number Terminals con- nected to common Switch Unit Connector C 12 4 8 456 7 /C0083 /C0083 /C0083 /C0083 /C0083 /C0083 /C0083 /C0083 /C0083 /C0083 /C0083 /C0083 /C0083 /C0083 /C0083 The solid dot /C0083 indicates that the internal switch is ON. Output Code Types Decimal Code 03: Decimal Code Output Model Switch Unit or Connector Common terminal number Terminals connected to common A7SS A7AS Switch Unit C 0 1 2 3 4 5 6 7 8 9 A7AS A7PS A7PH Connector 6 1 2 3 4 5 7 8 9 10 11 Dial 0 /C0083 1 /C0083 2 /C0083 3 /C0083 4 /C0083 5 /C0083 6 /C0083 7 /C0083 8 /C0083 9 /C0083 19: Decimal Code Output with Component-adding Provision Model Switch Unit or Connector Common terminal number Terminals connected to common A7SS A7AS Switch Unit C 0 1 2 3 4 5 6 7 8 9 A7AS A7PS A7PH Connector 6 1 2 3 4 5 7 8 9 10 11 Dial 0 /C0083 1 /C0083 2 /C0083 3 /C0083 4 /C0083 5 /C0083 6 /C0083 7 /C0083 8 /C0083 9 /C0083 Binary Code 01: Binary Code Output (+, – Switching) Model Switch Unit or Connector Common terminal number Terminals connected to common Dial + /C0083 /C0083 – /C0083 /C0083 : : : : : + /C0083 /C0083 – /C0083 /C0083 PM Models 1. For models other than those listed on the left, use models with 2. These models end with a -PM. Example: A7BS-206-PM The output codes and terminals are the same as the A7BS-206; however, binary code output is used between output terminal 1 and the common terminal.

A7BS Switch Unit C 1 2 4 8 Connector 2 4 5 6 7 Dial + (0) – (1) /C0083 + (2) /C0083 – (3) /C0083/C0083 + (4) /C0083 + (6) /C0083/C0083 – (7) /C0083/C0083/C0083 + (8) /C0083 Note: 1. The solid dot /C0083 indicates that the internal switch is ON. 2. Numbers enclosed in parentheses are the dial displays for the A7BS-206. Connectors A7BS-206-PM Thumbwheel Switch Connector Not used Binary Code Decimal 06: Binary-coded Decimal Output, Single-sided Board Model Switch Unit or Connector Common terminal number Terminals connected to common A7BL A7BS Switch Unit C 1 2 4 8A7BL A7BS Connector 2 4 5 6 7 A7MD (see note) A7MA (see note) A7SS A7DP Switch Unit C 1 2 4 8 A7DP A7D (see note) A7CN A7CN-L A7PS A7PH Connector 3 5 7 9 11 Dial 0 1 /C0083 2 /C0083 3 /C0083/C0083 4 /C0083 5 /C0083 /C0083 6 /C0083/C0083 7 /C0083/C0083/C0083 8 /C0083 9 /C0083 /C0083 Note: There is no Connector on the A7MD, A7MA, A7D /C0106, and A7C/C0106. 22: Complementary Code of 06 Model Switch Unit or connector Common terminal number Terminals connected to common A7BS Switch Unit C 1 2 4 8A7BS Connector 2 4 5 6 7 Dial 0 /C0083/C0083/C0083/C0083 1 /C0083/C0083/C0083 2 /C0083 /C0083/C0083 3 /C0083/C0083 4 /C0083/C0083 /C0083 5 /C0083 /C0083 6 /C0083 /C0083 7 /C0083 8 /C0083/C0083/C0083 9 /C0083/C0083

07: Binary-code Decimal Output with Component-adding Provision Model Switch Unit or Connector Common terminal number Terminals connected to common A7BL A7BS Switch Unit C 1 2 4 8A7BL A7BS Connector 1, 2 4 5 6 7 A7MA (see note) A7SS Switch Unit C 1 2 4 8 A7SS A7AS A7PS A7PH Connector 1, 3 5 7 9 11 Dial 0 1 /C0083 2 /C0083 3 /C0083/C0083 4 /C0083 5 /C0083 /C0083 6 /C0083/C0083 7 /C0083/C0083/C0083 8 /C0083 9 /C0083 /C0083 Note: There is no Connector on the A7MA. Binary-coded Hexadecimal 54: Binary-coded Hexadecimal Output Model Switch Unit or Connector Common terminal number Terminals connected to common A7BS Switch Unit C 1 2 4 8A7BS Connector 2 4 5 6 7 A7PS Switch Unit C 1 2 4 8 Connector 3 5 7 9 11 Dial 0 1 /C0083 2 /C0083 3 /C0083/C0083 4 /C0083 5 /C0083 /C0083 6 /C0083/C0083 7 /C0083/C0083/C0083 8 /C0083 9 /C0083 /C0083 A /C0083 /C0083 B /C0083/C0083 /C0083 C /C0083/C0083 D /C0083 /C0083/C0083 E /C0083/C0083/C0083 F /C0083/C0083/C0083/C0083 55: Binary-coded Hexadecimal Output with Component-ad- ding Provision Model Switch Unit or Connector Common terminal number Terminals connected to common A7BS Switch Unit C 1 2 4 8A7BS Connector 1, 2 4 5 6 7 A7PS Switch Unit C 1 2 4 8 Connector 1, 3 5 7 9 11 Dial 0 1 /C0083 2 /C0083 3 /C0083/C0083 4 /C0083 5 /C0083 /C0083 6 /C0083/C0083 7 /C0083/C0083/C0083 8 /C0083 9 /C0083 /C0083 A /C0083 /C0083 B /C0083/C0083 /C0083 C /C0083/C0083 D /C0083 /C0083/C0083 E /C0083/C0083/C0083 F /C0083/C0083/C0083/C0083

Note: All units are in millimeters unless otherwise indicated. Push-operated Switches A7DP-206(-1) PCB Terminals, Pen-push Model Note: Common terminal C is at the bottom when the Switch Unit is viewed from the front. Panel Cutout Panel thickness: 1 to 2 Number of Switches (n) A (n x 5.1 + 5) B (n x 5.1 + 3) C 1 10.1 mm 8.1 mm 8.4 mm 2 15.2 mm 13.2 mm 13.5 mm 3 20.3 mm 18.3 mm 18.6 mm 4 25.4 mm 23.4 mm 23.7 mm 5 30.5 mm 28.5 mm 28.8 mm 6 35.5 mm 33.5 mm 33.9 mm 7 40.6 mm 38.6 mm 39.0 mm 8 45.7 mm 43.7 mm 44.1 mm 9 50.8 mm 48.8 mm 49.2 mm 10 55.9 mm 53.9 mm 54.3 mm Note: 1. The dimensions above include both End Caps, and will increase 5.08 mm for each Spacer inserted. 2. Unless otherwise specified, a tolerance of ±0.4 mm ap- plies to all dimensions. The tolerance for multiple connection is ±(number of units x 0.4) mm. A7D-106(-1) PCB Terminals Note: Common terminal C is at the bottom when the Switch Unit is viewed from the front. Panel Cutout Panel thickness: 2 Tow, M2.6 or 2.8 mm holes Number of Switches (n) A (n x 5.1 + B (n x 5.1 + 8.3) C (n x 5.1 + 13.3) D 1 8.1 mm 13.4 mm 18.4 mm 8.4 mm 2 13.2 mm 18.5 mm 23.5 mm 13.5 mm 3 18.3 mm 23.6 mm 28.6 mm 18.6 mm 4 23.4 mm 28.7 mm 33.7 mm 23.7 mm 5 28.5 mm 33.8 mm 38.8 mm 28.8 mm 6 33.5 mm 38.9 mm 43.9 mm 33.9 mm 7 38.6 mm 44.0 mm 49.0 mm 39.0 mm 8 43.7 mm 49.1 mm 54.1 mm 44.1 mm 9 48.8 mm 54.2 mm 59.2 mm 49.2 mm 10 53.9 mm 59.3 mm 64.3 mm 54.3 mm Note: 1. The dimensions above include both End Caps, and will increase 5.08 mm for each Spacer inserted. 2. Unless otherwise specified, a tolerance of ±0.4 mm ap- plies to all dimensions. The tolerance for multiple connection is ±(number of units x 0.4) mm.

Note: Common terminal C is at the bottom when the Switch Unit is viewed from the front. Panel Cutout A7D-206(-1) PCB Terminals Panel thickness: 1 to 2 Number of Switches (n) A (n x 5.1 + 5) B (n x 5.1 + 3) C (n x 5.1 + 3.3) 1 10.1 mm 8.1 mm 8.4 mm 2 15.2 mm 13.2 mm 13.5 mm 3 20.3 mm 18.3 mm 18.6 mm 4 25.4 mm 23.4 mm 23.7 mm 5 30.5 mm 28.5 mm 28.8 mm 6 35.5 mm 33.5 mm 33.9 mm 7 40.6 mm 38.6 mm 39.0 mm 8 45.7 mm 43.7 mm 44.1 mm 9 50.8 mm 48.8 mm 49.2 mm 10 55.9 mm 53.9 mm 54.3 mm Note: 1. The dimensions above include both End Caps, and will increase 5.08 mm for each Spacer inserted. 2. Unless otherwise specified, a tolerance of ±0.4 mm ap- plies to all dimensions. The tolerance for multiple connection is ±(number of units x 0.4) mm. Two, M2.5 or M2.6 Panel thickness: 2 Panel Cutout PCB terminal A7CN-106-1 Note: Common terminal C is at the bottom when the Switch Unit is viewed from the front. Number of Switches (n) A (n x 6 + 6) B (n x 6 + 11) C (n x 6 + 16) 1 12 mm 17 mm 22 mm 2 18 mm 23 mm 28 mm 3 24 mm 29 mm 34 mm 4 30 mm 35 mm 40 mm 5 36 mm 41 mm 46 mm 6 42 mm 47 mm 52 mm 7 48 mm 53 mm 58 mm 8 54 mm 59 mm 64 mm 9 60 mm 65 mm 70 mm 10 66 mm 71 mm 76 mm Note: 1. The dimensions above include both End Caps, and will increase 6 mm for each Spacer inserted. 2. Unless otherwise specified, a tolerance of ±0.4 mm ap- plies to all dimensions. The tolerance for multiple connection is ±(number of units x 0.4) mm.

Panel thickness: 1 to 2 Panel Cutout PCB terminal A7CN-206(-1) Note: Common terminal C is at the bottom when the Switch Unit is viewed from the front. Number of Switches (n) A (n x 6 + 8) B (n x 6 + 6) 1 14 mm 12 mm 2 20 mm 18 mm 3 26 mm 24 mm 4 32 mm 30 mm 5 38 mm 36 mm 6 44 mm 42 mm 7 50 mm 48 mm 8 56 mm 54 mm 9 62 mm 60 mm 10 68 mm 66 mm Note: 1. The dimensions above include both End Caps, and will increase 6 mm for each Spacer inserted. 2. Unless otherwise specified, a tolerance of ±0.4 mm ap- plies to all dimensions. The tolerance for multiple connection is ±(number of units x 0.4) mm. Panel thickness: 1 to 2 When setting Panel Cutout PCB terminal Note: Common terminal C is at the bottom when the Switch Unit is viewed from the front. A7CN-L206(-1) Number of Switches (n) A (n x 6 + 8) B (n x 6 + 6) 1 14 mm 12 mm 2 20 mm 18 mm 3 26 mm 24 mm 4 32 mm 30 mm 5 38 mm 36 mm 6 44 mm 42 mm 7 50 mm 48 mm 8 56 mm 54 mm 9 62 mm 60 mm 10 68 mm 66 mm Note: 1. The dimensions above include both End Caps, and will increase 6 mm for each Spacer inserted. 2. Unless otherwise specified, a tolerance of ±0.4 mm ap- plies to all dimensions. The tolerance for multiple connection is ±(number of units x 0.4) mm.

A7BL-206(-1) A7BL-207(-1) Solder Terminals, Locking Models Note: If the output code is 06, the dimension is 32.5; if the output code is 07, the dimension is 43.5. When setting Panel thickness: 1 to 3 (See note) Number of Switches (n) A (n x 8 + 8) B (n x 8 + 6) C 1 16 mm 14 mm 14.4 mm 2 24 mm 22 mm 22.4 mm 3 32 mm 30 mm 30.4 mm 4 40 mm 38 mm 38.4 mm 5 48 mm 46 mm 46.8 mm 6 56 mm 54 mm 54.8 mm 7 64 mm 62 mm 62.8 mm 8 72 mm 70 mm 70.8 mm 9 80 mm 78 mm 78.8 mm 10 88 mm 86 mm 86.8 mm Note: 1. The dimensions above include both End Caps, and will increase 8 mm for each Spacer inserted. 2. Unless otherwise specified, a tolerance of ±0.4 mm ap- plies to all dimensions. The tolerance for multiple connection is ±(number of units x 0.4) mm. Panel Cutout Solder Terminals Note: If the output code is 06 or 54, the dimension is 32.5; if the output code is 07 or 55, the dimension is 43.5. Panel thickness: 1 to 3 (See note) Number of Switches (n) A (n x 8 + 8) B (n x 8 + 6) C 1 16 mm 14 mm 14.4 mm 2 24 mm 22 mm 22.4 mm 3 32 mm 30 mm 30.4 mm 4 40 mm 38 mm 38.4 mm 5 48 mm 46 mm 46.8 mm 6 56 mm 54 mm 54.8 mm 7 64 mm 62 mm 62.8 mm 8 72 mm 70 mm 70.8 mm 9 80 mm 78 mm 78.8 mm 10 88 mm 86 mm 86.8 mm Note: 1. The dimensions above include both End Caps, and will increase 8 mm for each Spacer inserted. 2. Unless otherwise specified, a tolerance of ±0.4 mm ap- plies to all dimensions. The tolerance for multiple connection is ±(number of units x 0.4) mm.

Note: If the output code is 03, 06 or 54, the dimension is 43; if the output code is 07, 19 or 55, the dimension is 55. (See note) Panel thickness: 1 to 3 Number of Switches (n) A (n x 10 + 12) B (n x 10 + 9) 1 22 mm 19 mm 2 32 mm 29 mm 3 42 mm 39 mm 4 52 mm 49 mm 5 62 mm 59 mm 6 72 mm 69 mm 7 82 mm 79 mm 8 92 mm 89 mm 9 102 mm 99 mm 10 112 mm 109 mm Note: 1. The dimensions above include both End Caps, and will increase 10 mm for each Spacer inserted. 2. Unless otherwise specified, a tolerance of ±0.4 mm ap- plies to all dimensions. The tolerance for multiple connection is ±(number of units x 0.4) mm. Thumbwheel-operated Switches Panel Cutout A7MD-106-P-09 A7MD-106-P-09-D PCB Terminals Panel thickness: 2 P = 2.54 Number of Switches (n) 1 8 mm 10 mm 2 13 mm 15 mm 3 18 mm 20 mm 4 23 mm 25 mm 5 28 mm 30 mm 6 33 mm 35 mm 7 38 mm 40 mm 8 43 mm 45 mm 9 48 mm 50 mm 10 53 mm 55 mm Note: 1. The dimensions above include both End Caps, and will increase 6 mm for each Spacer inserted. 2. Unless otherwise specified, a tolerance of ±0.4 mm ap- plies to all dimensions. The tolerance for multiple connection is ±(number of units x 0.4) mm.

A7MA-1/C0106/C0106 Solder Terminals Note: If the output code is 06, the dimension is 19; if the output code is 07, the dimension is 31. A7MA-1/C0106/C0106-P2 PCB Terminals Note: If the output code is 06, the dimension is 19; if the output code is 07, the dimension is 31. Panel thickness: 2 (See note) Two, M2.6 (See note) Panel thickness: 2 Two, M2.6 P = 2.54 Panel Cutout Panel Cutout Number of Switches (n) A (6n + 6) B (6n + 11) C (6n + 16) 1 12 mm 17 mm 22 mm 2 18 mm 23 mm 28 mm 3 24 mm 29 mm 34 mm 4 30 mm 35 mm 40 mm 5 36 mm 41 mm 46 mm 6 42 mm 47 mm 52 mm 7 48 mm 53 mm 58 mm 8 54 mm 59 mm 64 mm 9 60 mm 65 mm 70 mm 10 66 mm 71 mm 76 mm Note: 1. The dimensions above include both End Caps, and will increase 6 mm for each Spacer inserted. 2. Unless otherwise specified, a tolerance of ±0.4 mm ap- plies to all dimensions. The tolerance for multiple connection is ±(number of units x 0.4) mm.

Note: If the output code is 06, the dimension is 19; if the output code is 07, the dimension is 31. (See note) Panel thickness: 1 to 2 Number of Switches (n) A (6n + 8) B (6n + 10) 1 14 mm 16 mm 2 20 mm 22 mm 3 26 mm 28 mm 4 32 mm 34 mm 5 38 mm 40 mm 6 44 mm 46 mm 7 50 mm 52 mm 8 56 mm 58 mm 9 62 mm 64 mm 10 68 mm 70 mm Note: 1. The dimensions above include both End Caps, and will increase 6 mm for each Spacer inserted. 2. Unless otherwise specified, a tolerance of ±0.4 mm ap- plies to all dimensions. The tolerance for multiple connection is ±(number of units x 0.4) mm. Panel Cutout Note: If the output code is 06, the dimension is 19; if the output code is 07, the dimension is 31. PCB Terminals Panel thickness: 1 to 2 (See note) P = 2.54 Number of Switches (n) A (6n + 8) B (6n + 10) 1 14 mm 16 mm 2 20 mm 22 mm 3 26 mm 28 mm 4 32 mm 34 mm 5 38 mm 40 mm 6 44 mm 46 mm 7 50 mm 52 mm 8 56 mm 58 mm 9 62 mm 64 mm 10 68 mm 70 mm Note: 1. The dimensions above include both End Caps, and will increase 6 mm for each Spacer inserted. 2. Unless otherwise specified, a tolerance of ±0.4 mm ap- plies to all dimensions. The tolerance for multiple connection is ±(number of units x 0.4) mm.

Note: If the output code is 03 or 06, the dimension is 43; if the output code is 07, the dimension is 55. (See note) Panel thickness: 3.4 Four, M3 or 3.2 holes Panel Cutout Number of Switches (n) A (12.7n + 22) B (12.7n + 14.8) C (12.7n + 10) 1 34.7 mm 27.5 mm 22.7 mm 2 47.4 mm 40.2 mm 35.4 mm 3 60.1 mm 52.9 mm 48.1 mm 4 72.8 mm 65.6 mm 60.8 mm 5 85.5 mm 78.3 mm 73.5 mm 6 98.2 mm 91.0 mm 86.2 mm 7 110.9 mm 103.7 mm 98.9 mm 8 123.6 mm 116.4 mm 111.6 mm 9 136.3 mm 129.1 mm 124.3 mm 10 149.0 mm 141.8 mm 137.0 mm Note: 1. The dimensions above include both End Caps, and will increase 12.7 mm for each additional Switch inserted (6.35-mm wide Spacers are also available). 2. Unless otherwise specified, a tolerance of ±0.4 mm ap- plies to all dimensions. The tolerance for multiple connection is ±(number of units x 0.4) mm. Solder terminals Note: If the output code is 03 or 06, the dimension is 41.5; if the output code is 07 or 19, the dimension is 55. Panel thickness: 1 to 3 (See note) Panel Cutout Number of Switches (n) A (8n + 11) B (8n + 8) C (B + 1) 1 19 mm 16 mm 17 mm 2 27 mm 24 mm 25 mm 3 35 mm 32 mm 33 mm 4 43 mm 40 mm 41 mm 5 51 mm 48 mm 49 mm 6 59 mm 56 mm 57 mm 7 67 mm 64 mm 65 mm 8 75 mm 72 mm 73 mm 9 83 mm 80 mm 81 mm 10 91 mm 88 mm 89 mm Note: 1. The dimensions above include both End Caps, and will increase 8 mm for each additional Switch inserted. 2. Unless otherwise specified, a tolerance of ±0.4 mm ap- plies to all dimensions. The tolerance for multiple connection is ±(number of units x 0.4) mm.

Accessories (Order Separately) End Caps for Push-operated Switches A7D-1M(-1) Screw Mounting (Back Mounting) Left Side Right Side A7D-2M(-1) Snap-in Mounting (Front Mounting) Left Side Right Side A7CN-1M-1 Screw Mounting Left Side Right Side A7CN-2M-1 Snap-in Mounting Left Side Right Side A7B-M(-1) Snap-in Panel Mounting Left Side Right Side A7P-M(-1) Snap-in Panel Mounting Left Side Right Side

End Caps for Thumbwheel Switches A7MD-1M PCB Mounting (Side Plate) Left Side Right Side A7M-1M Screw Panel Mounting Left Side Right Side Note: The A7MD cannot be mounted by a screw panel or snap-in panel. Fasten the PC board after mounting the A7MD to the PC board. A7M-2M(-1) Snap-in Panel Mounting Left Side A7SS-M and SRT-M Screw Panel Mounting Left SideRight Side Right Side A7AS-M(-1) Snap-in Panel Mounting Left Side Right Side Spacers for Push-operated Switches A7D-1PA(-1) Screw Mounting (Back Mounting) A7D-2PA(-1) Snap-in Mounting (Front Mounting) A7CN-1P-1 Screw Panel Mounting Model A7CN-2P-1 Snap-in Mounting Model A7B-PA(-1) Snap-in Panel Mounting A7P-PA(-1) Snap-in Panel Mounting

Spacers for Thumbwheel Switches A7MD-PA PCB Mounting A7M-1PA Screw Panel Mounting A7M-2PA(-1) Snap-in Panel Mounting Stamping When units of time or lengths are required, stamping any of the additional Switches and Spacers above with text or symbols is possible. Desig- nate the desired stamping by symbol to substitute the “A” for the “-PA” on the model numbers according to the table below. Symbol A B C D E F G H J K L Q T U Stamp No desig- nation SEC MIN H g kg mm cm m °C PCS x 10 SEC 0 /C0083 Stopper Pins (for Only the A7BS-20/C0106-S) Note: 1. Two pins constitute one set. 2. The first shipment is free and is attached to the Switch. 2.4 dia. 1.2 dia. Connectors These devices allow Switches to be quickly removed for maintenance and inspection of connectivity, and quickly re-installed. A7B-C Solder Terminals A7B-CP PCB Terminals Inserting Connectors Insert Connectors with the “UP” arrow pointing up. 3.3 dia. P = 2.54 P = 2.54 0.6 x 0.6 Connector Note: Unless otherwise indicated, dimensional tolerances for dimensions in the models above are /C00340.4 mm.

/A7D-2 (PCB terminals) A7CN-2/A7CN-1 /A7CN-L (PCB terminals) A7BL (solder terminals) A7BS/A7BS-20/C0106-S (solder terminals) A7PS/A7PH (solder terminals) 03 --- -- -- -- 22, 1-dia. holes 14, 1-dia. holes 14, 1-dia. holes 10, 1-dia. holes 07 -- -- 28, 1-dia. holes 28, 1-dia. holes 23, 1-dia. holes 19 -- -- -- -- 44, 1-dia. holes 54 -- -- -- 14, 1-dia. holes 10, 1-dia. holes 55 -- -- -- 28, 1-dia. holes 23, 1-dia. holes

(PCB terminals) A7MA-/C0106 (solder terminals) A7MA-/C0106-P2 (PCB terminals) A7SS/A7AS (solder terminals) 01 -- -- -- -- 03 -- -- -- 22, 1-dia. holes 06 (13) 10, 1-dia. holes 10, 1-dia. holes 22, 1-dia. holes 07 (36) -- 18, 1-dia. holes 18, 1-dia. holes 44, 1-dia. holes 08 -- -- -- -- -- -- -- -- 19 -- -- -- 44, 1-dia. holes 22 -- -- -- --

Switches with Component-adding Provision To add diodes or resistors to Thumbwheel Switch circuits, use models with terminals that allocate component-adding provisions (e.g., output codes 07, 19, 55, etc.). Examples Circuit example Circuit board Application example For mounting diodes Diode Thumbwheel Switch Note: Use the terminal marked with the as- terisk * if the common terminal needs no re- sistor or diode. Diode Thumbwheel Switch (e.g., A7PS-207) For Programmable Controller inputs (OMRON C500 or C2000H) Thumbwheel Switch VDC programmable controller (+24 V) (0V) +24 VDC For mounting resistors Thumbwheel Switch Thumbwheel Switch (e.g., A7PS-219) Resistor As a voltage divider or digital variable resistor Output Input Thumbwheel Switch

Do not use where gases are generated (ammonia, chlorine, sulfur dioxide). Although Switches are of nearly dust-proof construction, they are not drip-proof, therefore do not use in areas subject to water or oil exposure and do not operate with wet or oily hands. (The A7MD has a dust-proof construction on contact parts, but consider your instal- lation location carefully. The A7MA is not of dust-proof construc- tion.) Provide additional dust-proofing measure when using in sand-ex- posed areas. Setting Numbers Locking Type Set with the setting button by raising it. Return the button to its original position after setting. It is then locked to prevent rotation, and the set numbers will not change accidental- ly. Pen-push Type To set, press the setting button with a ball-point pen or other pointed object. However, avoid using pencils or mechanical pencils as bro- ken lead or lead dust may enter and damage the Switch. Handling Use alcohol to wipe off dirt and smudges from the molded-plastic cases. Take care to prevent the alcohol from getting inside. Do not use thinner or other solutions which might damage the plas- tic. When connecting Switches, fit the mating parts together. When separating Switches, use a screwdriver as shown in the fig- ure below; disconnect them by releasing the top and bottom hooks. Do not push the (+) and (–) operating push-buttons at the same time with undue force. Terminals for PCB Models When using terminals for printed circuit boards, make the terminal insertion holes in the back board (mother board) 1 mm or larger in diameter. Do not use excessive force in handling terminals for printed circuit boards. In particular, take care to avoid dropping them as the termi- nals might bend or break. Reference: Terminals can withstand a force of 0.8 g for 1 minute or more, and survive bending of 20° without breaking after returning to original position. The A7MD accommodates only printed circuit boards. When pulling out the operating surface from the back of the panel, refer to the fig- ures for panel mounting dimensions. However, it cannot be fas- tened alone to the panel. Connectors Insert Connectors while keeping the arrow pointing up (refer to page 31). Connector insertion load is about 1.5 kg for each A7B-C. Setting the Stopper (A7BS-20/C0106-S) With the A7BS-20/C0106-S, any range can be set outside with the Stop- per Pin. Insert the Stopper Pin using the following procedure: (3) Stopper Pin (upper limit) (2) Stopper Pin (lower limit) (1) Display window Example: To Display the Range 0 to 7 1. Any number within the range of (0 to 7) can be chosen to limit the numbers displayed in the display window. (In this example, 8 and 9 are outside of this range.) 2. First, insert the Stopper Pin in the hole in front of the lower limit (“0”) for the number to be defined. 3. Next, inset the Stopper Pin in the hole past the upper limit (“7”) for the number to be defined. (The Stopper Pins then surround the exact range to be defined.) 4. Confirm that the (+) push-button can no longer be pushed after reaching the upper limit of (“7”).