1SBL411001R8811 ABB | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 4

Technical content

A75-30-11 230-240V 50Hz / 240-260V 60Hz General Information Extended Product Type: A75-30-11 230-240V 50Hz / 240-260V 60Hz Product ID: 1SBL411001R8811 EAN: 3471522093882 Catalog Description: A75-30-11 230-240V 50Hz / 240-260V 60Hz Contactor Long Description: A75 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC / 1000 V AC or 220 V DC. The contactors can also be used f or many other applications such as isolation, capacitor switching, lighting. The A... series 1- stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blo cks: 3 main poles and 2 built-in auxiliary contacts, front and side-mounted add-on auxiliary contact blocks - Control circuit: AC operated with laminated magnet circuit - Accessories: a wide range of accessories is available. Additional Information ABB Industrial IT Suite: Control IT ASEFA Certificate: ASEFA_15201 Ambient Air Temperature: Close to Contactor Fitted with Thermal O/L Relay -25 ... +55 °C Close to Contactor for Storage -60 ... +80 °C Close to Contactor without Thermal O/L Relay (Uc) -40 ... +70 °C BV Certificate: BV_2634H07559D0 Block Contactor Type: 3-Pole Contactor CB Certificate: CB_FR_602227A CCC Certificate: CCC_2008010309289461 CSA Certificate: CSA_1033838_LR056745 Climatic Withstand: acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II Coil Consumption: Average Holding Value 50 / 60 Hz 18 V·A Average Holding Value 50 / 60 Hz 5.5 W Average Pull-in Value 50 Hz 190 V·A Average Pull-in Value 60 Hz 180 V·A Coil Operating Limits: Coil Voltage Code: Connecting Capacity Auxiliary Circuit: Rigid Cable 1 ... 4 mm² Connecting Capacity Main Circuit: Flexible with Cable End 6 ... 16 mm² Rigid Cable 6 ... 25 mm² Connecting terminals (delivered in open position) Built-in auxiliary terminals: M 3.5 (+,-) pozidriv 2 screws with cable clamp Connecting terminals (delivered in open position) Coils terminals: M 3.5 (+,-) pozidriv 2 screws with cable clamp Connecting terminals (delivered in open position) Main poles: M 6 (+,-) pozidriv 2 screws with 1x (13 x 10 mm) connector Conventional Free-air Thermal Current acc. to IEC 60947-4-1, Open Contactors q = 40 °C 125 A acc. to IEC 60947-5-1, q = 40 °C 16 A Country of Origin: France (FR) Customs Tariff Number: 85364900 Data Sheet, Technical Information: 1SBC100122C0202_Ch02 Declaration of Conformity - CE: 1SBD250801U1000 Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 Drop-out Voltage in % of Uc: Approximate 40 … 65 % Products Low Voltage Products and Systems Control Products Contactors Block Contactors th

Drop-out Voltage in % of Uc: Approximate 40 … 65 % EAC Certificate: EAC_RU C-FR ME77 B01010 EAN: 3471522093882 ETIM 4: EC000066 - Magnet contactor, AC-switching ETIM 5: EC000066 - Magnet contactor, AC-switching ETIM 6: EC000066 - Power contactor, AC switching Environmental Information: 1SBD250010E1003 GOST Certificate: GOST_POCCFRME77B07175 IIT Publishing Status: Level 0 - Information enabled Industrial IT Certification Level: Instructions and Manuals: FPTC407700P0003 Invoice Description: A75-30-11 230-240V 50Hz / 240-260V 60Hz Contactor LOVAG Certificate: LOVAG_FR01006a-FR01030 LR Certificate: LRS_9830011E4 Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A Maximum Electrical Switching Frequency: AC-1 600 cycles per hour AC-2 / AC-4 150 cycles per hour AC-3 600 cycles per hour Maximum Mechanical Switching Frequency: 3600 cycles per hour Maximum Operating Altitude Permissible: 3000 m Mechanical Durability: 10 million Minimum Order Quantity: 1 piece Minimum Switching Capacity: 17 / 5 volt per milliamp Mounted Auxiliary Contacts 1st Stack:

1 NO, 1 NC

Mounted Auxiliary Contacts 2nd Stack:

0 NO, 0 NC

Mounting Position: Position 1 to 5 -Ambient temperature =<55°C and control voltage 0.85 - 1.1 Uc, Ambient temp erature 55 - 70°C and control voltage equal to Uc, Position 6 - Ambient temperature =<55°C and control voltage 0.95 - 1.1 Uc, Ambient temperature >55°C unauthorised Non-overlapping Time Between N.O. and N.C. Contacts: >= 2 ms Number of Auxiliary Contacts NC: Number of Auxiliary Contacts NO: Number of Main Contacts NC: Number of Main Contacts NO: Object Classification Code: Q Operate Time: Between Coil Energization and NO Contact Closing 8 ... 27 ms Between Coil De-energization and NO Contact Opening 4 ... 11 ms Between Coil De-energization and NC Contact Closing 7 ... 14 ms Between Coil Energization and NC Contact Opening 7 ... 22 ms Order Multiple: 1 piece Package Level 1 EAN: 3471522093882 Package Level 1 Gross Weight: 1.2 kg Package Level 1 Height: 96 mm Package Level 1 Length: 146 mm Package Level 1 Units: 1 piece Package Level 1 Width: 140 mm Package Level 2 Units: 20 piece Package Level 3 Units: 160 piece Power Loss: at Rated Operating Conditions per Pole 0.1 W at Rated Operating Conditions per Pole 7 W

at Rated Operating Conditions per Pole 7 W at Rated Operating Conditions per Pole 2 W Product Main Type: A75 Product Name: Block Contactor Product Net Depth: 108 mm Product Net Height: 110 mm Product Net Weight: 1.200 kg Product Net Width: 82 mm RINA Certificate: RINA_ELE128713XG001 RMRS Certificate: RMRS_0507015250 Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: 8 x Ie AC-3 Rated Breaking Capacity acc. to IEC 60947-5-1: 10 x Ie AC-15 Rated Control Circuit Voltage (U

50 Hz 230 … 240 V

60 Hz 240 … 260 V

Rated Frequency (f): Supply Circuit 50 Hz Supply Circuit 60 Hz Rated Frequency Limits: 25 … 400 Hz Rated Impulse Withstand Voltage (U 8 kV Rated Insulation Voltage (U acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V acc. to UL/CSA 600 V Rated Making Capacity AC-3 acc. to IEC 60947-4-1: 10 x Ie AC-3 Rated Making Capacity acc. to IEC 60947- 5-1: 10 x Ie AC-15 Rated Operational Current AC-1 (I (690 V) 40 °C 125 A (690 V) 55 °C 105 A (690 V) 70 °C 85 A Rated Operational Current AC-15 (I (220 / 240 V) 4 A (24 / 127 V) 6 A (380 / 440 V) 3 A (500 V) 2 A (690 V) 2 A Rated Operational Current AC-3 (I (1000 V) 55 °C 28 A (220 / 230 / 240 V) 55 °C 75 A (380 / 400 V) 55 °C 75 A (415 V) 55 °C 72 A (440 V) 55 °C 70 A (500 V) 55 °C 65 A (690 V) 55 °C 46 A Rated Operational Current DC-13 (I (125 V) 0.55 / 69 A (24 V) 6 / 144 A (250 V) 0.3 / 75 A (48 V) 2.8 / 134 A (72 V) 1 / 72 A Rated Operational Power AC-3 (P (220 / 230 / 240 V) 22 kW (380 / 400 V) 37 kW (415 V) 40 kW (440 V) 40 kW (500 V) 45 kW (690 V) 40 kW Rated Operational Power AC-6b (P (690 V) 70 °C, 50 / 60 Hz 70 kvar (690 V) 55 °C, 50 / 60 Hz 82 kvar (690 V) 40 °C, 50 / 60 Hz 82 kvar (500 / 550 V) 70 °C, 50 / 60 Hz 51 kvar (500 / 550 V) 55 °C, 50 / 60 Hz 60 kvar c imp i e e e e e e

(500 / 550 V), 40 °C, 50 / 60 Hz 60 kvar (440 V) 70 °C, 50 / 60 Hz 45 kvar (440 V) 55 °C, 50 / 60 Hz 52 kvar (440 V) 40 °C, 50 / 60 Hz 52 kvar (400 / 415 V) 70 °C, 50 / 60 Hz 41 kvar (400 / 415 V) 55 °C, 50 / 60 Hz 48 kvar (400 / 415 V) 40 °C, 50 / 60 Hz 48 kvar (230 / 240 V) 70 °C, 50 / 60 Hz 24.5 kvar (230 / 240 V) 55 °C, 50 / 60 Hz 28 kvar (230 / 240 V) 40 °C, 50 / 60 Hz 28 kvar Rated Operational Voltage: Main Circuit 1000 V Rated Short-time Withstand Current (I at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 650 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 135 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 370 A for 0.1 s 140 A for 1 s 100 A RoHS Date: 20050501 RoHS Information: 1SBD350061R1000 RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment Selling Unit of Measure: piece Short Description: A75-30-11 230-240V 50Hz / 240-260V 60Hz Contactor Short-Circuit Protective Devices: Auxiliary Circuit - gG Type Fuses 10 A gG Type Fuses 160 A Standards: Devices complying with international standards IEC 947-1 / 947-4-1, and European standard s EN 60 947-1 / 60 947-4-1. Electromagnetic compatibility (EMC) acc. to amendment A11 to I EC 947-1; EN 60 947-1 and amendment 2 to IEC 947-4-1 Terminal Type: Screw Terminals UL Certificate: UL_20120830-E312527-10-1 UL Listing Card: UL_E312527 UNSPSC: 39121529 DNV GL Certificate: DNV-GL_TAE00000TX cw