All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft® and Trust the Shield® are trademarks of Ashcroft Inc. The following non-Ashcroft trademarks are the property of their respective owners: 17-4PH®, Aminco®, Bendix®, Hirschmann®, Tri-Clamp® and VCR®. For more information, see Ashcroft Brands & Trademarks of 4 A4 Pressure Transmitter

FEATURES

Highly configurable: wide selection of pressure ranges, pressure connections and electrical terminations Available with externally adjustable zero and span access TYPICAL USES Oil field equipment Upstream oil and gas production Natural gas compression and transfer control Alternative energy projects KEY BENEFITS

  • Provides the user with accurate, reliable, and stable output data
  • Board microprocessor provides extremely linear and precise performance over the entire pressure and temperature range
  • Ideal for a broad spectrum of pressure sensing requirements where Intrinsically safe or Non-Incendive hazardous location rating are required PERFORMANCE SPECIFICATIONS Reference Temperature: 70 °F (21 °C) Accuracy Class (Includes non-linearity): Terminal Point Method includes: hysteresis, non-repeatability, zero offset and span setting errors Best Fit Straight Line (BFSL): Add ± 0.05% for ranges >5,000 psi Durability: >10 million cycles Stability: ≤±0.25% span/year at reference conditions ENVIRONMENTAL SPECIFICATIONS Temperature Effects: -4 °F to 185 °F (-20 °C to 85 °C) ±1.0% of span for ±0.25% accuracy class ±2.0% of span for ±0.5% and ±1.0% accuracy class Temperature Limits: Storage: Operating: Compensated: -40 °F to 257 °F (-40 °C to 125 °C) -40 °F to 257 °F (-40 °C to 125 °C) -4 °F to 185 °F (-20 °C to 85 °C) Humidity Effects: 0-95% R.H. non-condensing (no effects) 0-100% R.H. with welded enclosure (no effects) FUNCTIONAL SPECIFICATIONS Response Time: < 2 ms Pressure Ranges: Vacuum, gauge, compound and absolute pressure from 0 to 5 psi through 0 to 10,000 psi (Bar ranges available) Shock: 100 g Peak, 11 ms Random Vibration: 10 g RMS, 20-2,000 Hz Sweep Vibration: 50-2,000 Hz, 5 g Peak Position Effect: ±0.02%, typical Overpressure: ≤300 psi ≥500 to ≤10,000 psi Proof: 1.5X Range 1.2X Range Burst: 2X Range 1.5X Range ELECTRICAL SPECIFICATIONS Circuit Protection: Reverse polarity and mis-wire protected Insulation Resistance (Circuit Case):

100 MΩ @ 30 Vdc

Output Signal: 4-20 mA (2 Wire) Supply Voltage: (Unregulated) Mimimum: 12 Vdc Maximum: 30 Vdc Electrical Terminations: See ordering code on page 2 for options Power Requirements: See load limitations chart on page 2 Pressure Transmitter

All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft® and Trust the Shield® are trademarks of Ashcroft Inc. The following non-Ashcroft trademarks are the property of their respective owners: 17-4PH®, Aminco®, Bendix®, Hirschmann®, Tri-Clamp® and VCR®. For more information, see Ashcroft Brands & Trademarks of 4 A4 Pressure Transmitter LOAD LIMITATIONS 4-20 mA OUTPUT ONLY HAZARDOUS AREA CERTIFICATIONS Intrinsically Safe: FM/CSA Intrinsic Safety: Class I, II and III Div. 1 and 2 Groups A, B, C, D, F and G per entity requirements see Ashcroft drawing #825A022 Non-incendive: Class I, II and III Div. 2, Groups A, B, C, D, F and G, no barriers needed WETTED MATERIAL Diaphragm Process Connection 316L Stainless steel 316L Stainless steel NON-WETTED Housing

304 Stainless steel

VdcMin = 12V + (0.022A* X (RL)) RL = RS+ RW RL = Loop Resistance (ohms) RS = Sense Resistance (ohms) RW = Wiring Resistance (ohms) * (Includes a 10% safety factor) RL-Loop Resistance (/uni03A9) PHYSICAL SPECIFICATIONS Environmental Rating: IP65, NEMA 4X

All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft® and Trust the Shield® are trademarks of Ashcroft Inc. The following non-Ashcroft trademarks are the property of their respective owners: 17-4PH®, Aminco®, Bendix®, Hirschmann®, Tri-Clamp® and VCR®. For more information, see Ashcroft Brands & Trademarks of 4 A4 Pressure Transmitter ORDERING CODE Example: A4 S A M01 42 F2 50# G –X6B Model A4 - Intrinsically safe / non-incendive pressure transmitter A4 Enclosure S - Basic S W - Welded w/out zero & span access Accuracy/Temp. Effects Pressure Connection F01 - 1/8 NPT Female F02 - 1/4 NPT Female F04 - 1/2 NPT Female F09 - 9/16-18 (1/4)-Female (Aminco ®) FRW - 7/16-20 SAE-Female M01 - 1/8 NPT Male M01 M02 - 1/4 NPT Male M04 - 1/2 NPT Male MEK - 7/16-20 SAE-Male MG2 - G1/4 Male MG4 - G1/2 Male VM2 - 9/16-18 Male nut (compatible with 1/4 VCR ® fitting) VF2 - 9/16-18 Female nut (compatible with 1/4 VCR ® fitting) S15 - Sanitary seal 11/2˝ Tri-Clamp ® S20 - Sanitary seal 2˝ Tri-Clamp ® Output Signal 42 - 4-20 mA 42 Electrical Termination Integral Cable (Pigtail) F2 - 3´ Shielded cable ( available with enclosure code S ) F2 P1 - Specify length ( available with enclosure code S ) Hirschmann ® Style Form A DIN 43650-A DN - W/o mating connection ( available with enclosure code S ) D0 - With mating connection, no cable (available with enclosure code S ) D2 - With mating connection, 3´ cable ( available with enclosure code S ) D1 - With mating connection, specify length ( available with enclosure code S ) 4-Pin Bendix ® Style B4 - W/o mating connection ( available with enclosure code S ) H1 - With mating connection, no cable (available with enclosure code S ) L1 - With mating connection, 3´ cable (available with enclosure code S ) P2 - With mating connection, specify length (available with enclosure code S ) 1/2 NPT-M Conduit Shielded Cable (NEMA Rating not valid for ranges ≤500 psi) C1 - 3´ Shielded cable (available with enclosure code W) C6 - 15´ Shielded cable ( available with enclosure code W) C7 - 30´ Shielded cable ( available with enclosure code W) P7 - Shielded cable specify length ( available with enclosure code W) 1/2 NPT-M Conduit Flying Leads (NEMA Rating not valid for ranges ≤500 psi) C2 - 3´ Flying leads ( available with enclosure code W) C5 - 10´ Flying leads ( available with enclosure code W) M12 Threaded EW - W/o mating connection ( available with enclosure code S ) E0 - With mating connection, no cable ( available with enclosure code S ) E2 - With mating connection, 3´ cable ( available with enclosure code S ) E1 - With mating connection specify length ( available with enclosure code S ) Pressure Range (see range table on page 4) 50# - 50 psi 50# Measurement Type G - Gauge pressure G Option (if including an option(s) must include an “X’’) X _ _ CL - Non-standard calibration K8 - 17-4PH® Stainless steel sensor material 6B - Cleaned for oxygen service (Not available with absolute ranges) 6B

All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft® and Trust the Shield® are trademarks of Ashcroft Inc. The following non-Ashcroft trademarks are the property of their respective owners: 17-4PH®, Aminco®, Bendix®, Hirschmann®, Tri-Clamp® and VCR®. For more information, see Ashcroft Brands & Trademarks of 4 A4 Pressure Transmitter DIMENSIONS in [ ] are millimeters Intrinsically Safe (Enclosure S, W) 3.065 4.45 0.887 4.78 3.065 0.675 1.06 DIA. [22.5] [121] [78] [17] [27] 0.50 0.885 1.06 [27] Hex. Common For All Pressure Fittings [22] [78] [113] [13] 1.06 DIA. [27] RANGE TABLE Vacuum Range Code Notes 0 psi/-14.7 psi 0#&vac 17-4PH® SS sensor not available, gauge pressure only 15 psi/-14.7 psi 15#&vac 17-4PH® SS sensor not available, gauge pressure only Compound 30 psi/-14.7 psi 30#&vac 17-4PH® SS sensor not available, gauge pressure only 45 psi/-14.7 psi 45#&vac Gauge pressure only 60 psi/-14.7 psi 60#&vac Gauge pressure only 1.5 psi 1.5# 17-4PH® SS sensor not available, gauge pressure only, available with accuracies B or C only 5 psi 5# 17-4PH® SS sensor not available, gauge pressure only 10 psi 10# 17-4PH® SS sensor not available, gauge pressure only 15 psi 15# 17-4PH® SS sensor not available Positive Pressure 30 psi 30# 17-4PH® SS sensor not available 50 psi 50# 60 psi 60# 75 psi 75# 100 psi 100# 150 psi 150# 200 psi 200# 300 psi 300# 500 psi 500# 750 psi 750# 1,000 psi 1000# 1,500 psi 1500# 2,000 psi 2000# 3,000 psi 3000# 5,000 psi 5000# 6,000 psi 6000# 7,500 psi 7500# 10,000 psi 10000# 17-4PH® SS sensor required