Enabling Grip Switch with Distinct Feel for Three Easily Discernible Positions ■ The difficult task of configuring safety circuits is now easily achieved by combining the A4EG with the G9SX-GS. ■ In addition to the standard models, the lineup also includes models with an emergency stop switch and models with a momentary operation switch. ■ An optional Holding Key (sold separately) provides a versatile method for selecting modes. ■ Equipped with conduit connector.

Ordering Information

Accessories (Order Separately) Be sure to read the “Safety Precautions” on page 12. Appearance Contact form ModelEnabling switch Monitor switch Pushbutton switch Two contacts 1NC (grip output) None A4EG-C000041 Two contacts None Emergency stop switch (2NC) A4EG-BE2R041 Two contacts None Momentary operation switch (2NO) A4EG-BM2B041 Appearance Item Model Rubber Cover (replacement part) A4EG-OP1 Mounting Bracket (for securing the A4EG) A4EG-OP2 Holding Key A4EG-OP3

Standards and EC Directives Compliance with EC Directives and International Standards

  • Low Voltage Directive
  • GS-ET-22 Certified Standards * Certification for CSA C22.2 No. 14 by UL is indicated by the . Certified Standard Ratings (Enabling Switch Section) TÜV (EN 60947-5-1) Note: Use a 10-A fuse type gI or gG that conforms to IEC 60269 as the short-circuit protection device. The fuse is not built into the Switch. UL/CSA (UL 508, CSA C22.2 No.14), CCC (GB 14048.5)
  • 24 VDC, 0.3 A (inductive load)
  • 125 VAC, 1 A (resistive load) Ratings Certifying body Standard File No. TÜV Product Service EN 60947-5-1 (certified direct opening) Ask your OMRON representative. UL * UL 508, CSA C22.2 No.14 E76675 CQC (CCC) GB 14048.5 Pending approval Item Utilization category AC-15 DC-13 Rated operating current (Ie) 0.75 A 0.55 A Rated operating voltage (Ue) 240 V 125 V Item Section Enabling switch Emergency stop switch (A4EG-BE2R041 only) Pushbutton (A4EG-BM2B041 only) Rated insulation voltage 250 V --- Rated ON current 2.5 A 5 A 0.1 A Rated load 24 VDC, 0.3 A (inductive load)

125 VAC, 1 A (resistive load)

EN certification rating: AC-15 0.75 A/240 V DC-13 0.55 A/125 V General rating:

125 VAC, 5 A (resistive load)

250 VAC, 3 A (resistive load)

30 VDC, 3 A (resistive load)

UL and cUL rating:

125 VAC, 5A

(inductive load, power factor: 0.75 to 0.8)

250 VAC, 3 A

(inductive load, power factor: 0.75 to 0.8) General rating: 125 VAC, 0.1 A (resistive load) 8 VDC, 0.1 A (resistive load) 14 VDC, 0.1 A (resistive load) 30 VDC, 0.1 A (resistive load) Minimum applicable load 24 VDC, 4 mA 5 VDC, 1 mA

Note: The timing of contact outputs for two or more circuits is not synchronized. Confirm performance before application. Item Section Enabling switch Emergency stop switch (A4EG-BE2R041 only) Pushbutton (A4EG-BM2B041 only) Degree of protection IP66 (A4EG-C000041), IP65 (A4EG-BE2R041, A4EG-BM2B041) Operating section strength Operating direction: 200 N, 1 min Operating direction: 367 N, 1 min Rotating direction: 0.49 N·m, 1 min Operating direction: 50 N, 1 min Cable pull strength 30 N, 1 min Allowable operating frequency Electrical 20 operations/minute max. 10 operations/minute max. (set/reset for one operation) 60 operations/minute max. Mechanical 20 operations/minute max. 10 operations/minute max. (set/reset for one operation) 120 operations/minute max. Electrical durability 100,000 operations min. (rated load) 100,000 operations min. (set/reset for one operation) (rated load) 100,000 operations min. (rated load) Mechanical durability OFF-ON-OFF (direct opening): 100,000 operations min. OFF-ON: 1,000,000 operations min. 100,000 operations min. (set/reset for one operation) 2,000,000 operations min.Dielectric strength Between terminals of the same polarity 2,500 VAC, 50/60 Hz, 1 minute (impulse voltage) 1,000 VAC, 50/60 Hz, 1 minute 1,000 VAC, 50/60 Hz, 1 minute Between terminals of the different polarity 2,500 VAC, 50/60 Hz, 1 minute (impulse voltage) 2,000 VAC, 50/60 Hz, 1 minute 2,000 VAC, 50/60 Hz, 1 minute Between each terminal and non-current carrying metallic parts 2,500 VAC, 50/60 Hz, 1 minute (impulse voltage) 2,000 VAC, 50/60 Hz, 1 minute 2,000 VAC, 50/60 Hz, 1 minute Insulation resistance 100 MΩ min. (at 500 VDC) Vibration resistance Malfunction 1.5 mm double amplitude, 10 to 55 Hz Shock resistance Malfunction 150 m/s2 max. Ambient operating temperature −10 to 55°C (with no icing or condensation) Ambient operating humidity 35% to 85% Ambient storage temperature −25 to 65°C (with no icing or condensation) Protection against electric shock Class II (double insulation) Pollution degree (operating environment) 3 (EN 60947-5-1) Conditional short-circuit current 100 A (EN 60947-5-1)

Structure and Nomenclature Structure Contact Forms Operating Patterns A4EG-C000041 A4EG-BE2R041 A4EG-BM2B041 * Refer to Dimensions on page 7 for information on the positions of pushbutton switches A and B. OPEN ON: CLOSED CLOSED OFF: OPEN Note: 1. The contact ON/OFF timing is not synchronized. Confirm performance before application. 2. Direct opening only during grip. Operating Characteristics Chart (Enabling Switch Section) Operating Stroke (Enabling Switch Section) Operating Force (Enabling Switch Section: Reference Values) * HF: Holding force Operating Force (Emergency Stop Switch Section: Reference Values) Operating Force (Pushbutton Switch Section: Reference Value) A4EG-C000041 A4EG-BE2R041 A4EG-BM2B041 Terminal 2 Terminal 1 Terminal 5 Terminal 6 Terminal 3 Terminal 4 Terminal 8 Terminal 7 Emergency Stop Switch Section/ Pushbutton Switch Section Terminal 2 Terminal 1 Terminal 5 Terminal 6 Terminal 3 Terminal 4 Enabling Switch Section Three Positions: OFF - ON - OFF Contact Configuration Position 1 OFF OFF Not Gripped Gripped to Middle Position Gripped past Middle Position Gripped lightly Released Released Gripped Farther Position 3Position 2 ON Enabling Switch Emergency Stop S witch P ushbutton Switch (5) (7) (6) (8) Terminal No. Terminal No. Terminal No. (5) (7) (6) (8) Terminal No. Terminal No. (1) (3) (5) (2) (4) (6)Terminal No. Terminal No. * Terminal No. (5), (6): A4EG-C000041 only Operation Terminal No. Position 1 Position 2 Position 3 Enable output 1 to 2 3 to 4 Grip output 5 to 6 Operation Terminal No. Position 1 Position 2 Position 3 Enable output 1 to 2 3 to 4 Pushbutton switch Terminal No. Operation Contact Emergency stop switch output 5 to 6 7 to 8 Operation (push) ON → OFF Reset (turn reset) OFF → ON Operation Terminal No. Position 1 Position 2 Position 3 Enable output 1 to 2 3 to 4 Pushbutton switch Terminal No. Operation Contact Pushbutton switch output 5 to 6 (pushbutton switch A) * Push OFF → ON 7 to 8 (pushbutton switch B) * Push OFF → ON Operating characteristics Specified value Enable output (ON) PT2 max. 3.6 mm Max. enable holding position TT1 Approx. 4.2 mm Enable direct opening position PT3 max. 6.0 mm Max. stroke TT2 Approx. 6.7 mm Operating characteristics Specified value Enable operating force OF1 max. 14 N Enable holding force HF * Approx. 8 N Grip operating force OF2 max. 40 N Operating characteristics Specified value Operating force OF max. 14.7 N Reset force RF max. 0.1 N·m Operating characteristics Specified value Operating force OF max. 3 N Operating stroke PT1 HF OF1 OF2 PT2 TT1 PT3 PT4 TT2 Operating force Enable output (1-2, 3-4) Grip output (5-6)

Dimensions (Unit: mm) Enabling Grip Switches Enabling switch D4NS (order separately) A4EG-OP3 Holding Key (order separately) (34) 47.6 102.6 (50) 174 (277) 54.2 76.2 Enabling switch Conduit connector MG20A-P-13B Flexible Super Gland Manufactured by AVC Corporation of Japan (included) (34) 174 (50) (262) 38 44 Holding Key Mounted A4EG-C000041 Enabling switch Emergency stop switch Conduit connector MG20A-P-13B Flexible Super Gland Manufactured by AVC Corporation of Japan (included) (34)(50) 174 (191) (279) 38 44 A4EG-BE2R041 Holding Key Mounted Enabling switch Emergency stop switch D4NS (order separately) A4EG-OP3 Holding Key (order separately) (34) 174 (191) (50) (294) 47.6 102.6 76.2 54.2

Accessories (Order Separately) Enabling switch Pushbutton switch A Pushbutton switch B Conduit connector MG20A-P-13B Flexible Super Gland Manufactured by AVC Corporation of Japan (included) (50) 174 (189) (277) (34) (34) A4EG-BM2B041 Holding Key Mounted Enabling switch D4NS (order separately) A4EG-OP3 Holding Key (order separately) (34) 174 (189) (292) 47.6 102.6 76.2 54.2 (50) 83.2 43.3 235.9 Rubber Cover (Replacement Part) A4EG-OP1 Mounting Bracket (for Securing the A4EG) A4EG-OP2 Mounting surface Two, 5.3-dia. holes (88) (82) (44) Holding Key A4EG-OP3 Enabling Grip Switch Mounted Note: The screws are not included.

Machining Equipment Maintenance Mode

  • Switching between normal operation mode and maintenance mode is performed manually.
  • In normal operation mode, the Safety Door Switch is enabled, and in maintenance mode, the Enabling Grip Switch is enabled. Basic Unit G9SX-BC Logical AND connection Emergency Stop Switch, e.g., A22E Enabling Grip Switch A4EG Key-type Selector Switch A22K Safety Guard Switching Unit G9SX-GS Conveyor Emergency Stop Switch Normal Operation Mode Maintenance Mode Door Enabling Grip Switch When pressed, processing will stop. When the door is opened, processing will stop. Emergency Stop Switch Door Enabling Grip Switch When pressed, processing will stop. The Door Switch will be disabled. The Enabling Grip Switch will be disabled. Contactor 2. Door Guard Lock Safety-door Switch, e.g., D4NL 2. Door 4. Mode Selector 1. Emergency Stop Switch 1. Emergency Stop Switch 3. Enabling Grip Switch 3. Enabling Grip Switch 4. Mode Selector Processing will be possible only when the operator is gripping the Enabling Grip Switch.

Settings (For details, refer to section 3 of the G9SX User’s Guide (Cat. No. Z255).) G9SX-BC: Manual reset, cross fault det ection: ON (category 4 wiring) G9SX-GS: Manual reset, cross fault detection: ON (categor y 4 wiring), logical AND connection setting: AND ON-delay time setting: Time is set. Switching mode: Manual External indicator diagnosis: Enabled Wiring Example S14A2 S24 L1 L2 X1 X2 T11A1 T12 T21 T22 T31 T32 T33 Y1 KM2 KM1 11 21 +24 V KM1 KM2 KM2 KM1 PLC etc. KM4 KM3 +24 V +24 V KM4 KM3 KM4KM3 PLC etc. Open Open Open OpenOpen Feedback loop Feedback loop To PLC To PLC G9SX-BC202 Control circuit S14A2 S24 S44 S54 L1 X3X2X1 X4 T11A1 T12 T21 Y1 Y3T22 T61 T62M1 M2 T71 Y2 Y4T72 T31 T32 T33 T41 T42 OFF AND Auto Manual G9SX-GS226-T15 Control circuit S3 S7 +24 V GND GND Indicator (Diagnostic check enabled) Indicator (Diagnostic check enabled) Enabling Grip Switch OPEN KM3 KM4 Stop signal Door Lock release signal UA UB +24 V Mode selector S1: Emergency Stop Switch S2, S7: Reset switches S3: Enabling Grip Switch S4: Guard lock Safety-door Switch S5: Lock release switch S6: Safety limit switch KM1 to KM4: Contactors M1 to M2: 3-phase motors Note: For this circuit example, the category is equivalent to 4.

(1) The lower unit starts in operation mode. (2) The mode switches to maintenance mode. (3) The operator opens the door and performs maintenance work. (4) The Enabling Grip Switch is gripped to the middle position. (5) The lower unit starts in maintenance mode. (6) The lower unit will stop when the Enabling Grip Switch is released or gripped. (7) The lower unit will start again after the door is closed and the mode is switched to operation mode. (8) The lower unit will stop when the do or is open while in operation mode. (9) The door is closed and the lower unit starts again. (10) The upper unit and lower unit will stop if the emergency stop is pressed. G9SX-BC202 (Upper Unit) Reset switch S2 KM1, KM2 NC contact KM1, KM2 NO contact Logical AND output L1 Logical AND input T41 Emergency stop switch S1 Guard lock safety-door switch S4 Enabling grip switch S3 KM3, KM4 NC contact Mode selection input M2 Mode selection input M1 Reset switch S7 KM5, KM6 NC contact KM3, KM4 NO contact KM5, KM6 NO contact OFF-delay timeOFF-delay time OFF-delay time OFF-delay time (8)(3) (6)(4) (1) (2) (7)(5) (9) G9SX-GS226-T15 (Lower Unit) (10)

!WARNING

  • This product is a switch for teaching the machine such as robot in hazardous area. The machine is allowed to operate only when operating the switch continuously. Configure the system so that the machine can be operated only at position 2.
  • Apply load current not to exceed the rated value.
  • Do not use the switch submerged in oil or water or in locations continuously subject to splashes of oil or water. Doing so may result in oil or water entering the switch.
  • Do not use the switch in locations where explosive or flammable gasses may be present.
  • Mount the switch securely to prevent it from falling. Otherwise, injuries may occur.
  • The durability of the switch is greatly influenced by the switching conditions. Always test the switch under actual conditions before application and use it in a switching circuit for which there are no problems with performance.
  • Always attach the cover after completing wiring and before using the switch. Electric shock may occur if the switch is used without the cover attached.
  • The user must not maintain or repair equipment incorporating the switch. Contact the manufacturer of the equipment for any maintenance or repairs required.
  • Do not disassemble or remodel the switch in any case, or the switch will not operate normally.
  • Do not override by inserting the Holding Key itself in the door switch.
  • Configure the circuit so that the machine does not operate when operating the Enabling Switch while the Holding Key is being inserted in the door switch.
  • Do not impose excessive vibration or shock on the Door Switch while the Holding Key is inserted. Excessive vibration or shock may cause the Switch to fail or break.
  • Do not incline and pull the switch body or do not impose shock on the switch body in the directions shown with the arrows in Fig.1. Otherwise, the switch may be damaged and may not operate properly.
  • Refer to the D4NS Safety-door Switch Datasheet and Instruction Sheet about the storage, ambient conditions, the details and handling of the Switch.
  • Do not hold the Enabling Switch Device at Position 2 by any other methods except for handling. Otherwise, the original function of the Enabling Switch Device is not worked. Operating Environment
  • This switch is designed for use indoors. Using the switch outdoors may damage it.
  • The switch contacts can be used with either standard loads or microloads. Once the contact be used to switch smaller loads. The contact surfaces will become rough once they have been used and contact reliability for smaller loads may be reduced.
  • Do not use the switch in the following locations.
  • Locations where the interior of the Protective Door may into direct contact with cutting chips, metal filings, oil chemicals
  • Locations subject to detergents, thinners, or other solvents
  • Locations subject to sudden temperature changes
  • Locations subject to high humidity and condensation
  • Locations subject to severe vibration
  • Do not use the switch where corrosive gasses (e.g.,H 2S, SO2, NH3,HNO3, or Cl2) are present or in locations subject to high temperature and humidity. Doing so may result in damage to the switch as a result of contact failure or corrosion.
  • Do not store the switch where corrosive gasses (e.g.,H 2S, SO2, NH3,HNO3, or Cl2) or dust are present or in high temperature and humidity.
  • If the switch is not turned ON and OFF for a long period of time, contact resistance may be increased or continuity failure may occur due to contact oxidation. Mounting Method Specified Tightening Torque Loose screws may result in malfunction. Tighten the screws at the specified torques. Cover Mounting
  • Dislocation of the seal rubber or foreign substance on the seal rubber reduces seal performance of the switch. Mount the cover after confirming that there is no abnormality on the seal rubber. If the seal rubber cracks or breaks, replace the Cover with a new one (A4EG-OP1 Rubber Cover, separately sold).
  • Do not touch the rubber boot with sharp objects. Otherwise, the rubber boot may break and the operating characteristics and the seal performance may not be satisfied. Installing Mounting Bracket
  • Securely install the Mounting Bracket using M5 screws and washers and tighten them to a torque of 2.4 to 2.8 N·m. Always verify the operation of the safety functions before starting the system. Not doing so may result in the safety functions not performing as expected if the wiring or settings are incorrect or the switches have failed. Do not drop the switch. Doing so may damage the switch and the system may continue to operate, possibly causing injury or death. Precautions for Safe Use Arrow indicates insertion-pull direction. Holding Key A4EG-OP3 (sold separately) D4NS (sold separately) A4EG No operation Insertion-pull direction (Perpendicular direction) No operation No operation No operation Top position Mounting surface Magnified View Fig. 1 Precautions for Correct Use Item Specified torque Cover mounting screw 1.1 to 1.3 N·m Terminal screw 0.4 to 0.5 N·m Holding Key mounting screw 0.5 to 0.7 N·m Conduit Connector mounting (Conforming spanner 27 mm (width across flats)) 2.0 to 2.4 N·m Mounting Bracket 2.4 to 2.8 N·m Seal Cover, A4EG-OP1 (sold separately) Rubber boot Seal rubber

Holding Key Type (sold separately)

  • Use the A4EG-OP3 Holding Key when using the A4EG combining with the door switch.
  • Use the D4NS Safety-door Switch.
  • Loose screws may result in malfunction. Tighten the screws at the specified torques. Adhesive is recommended to prevent screws from being loose. The specified torque: 0.5 to 0.7 N·m (Mounting screw, 2pcs.)
  • Do not impose excessive force on the tip of the Holding Key or do not drop the switch body when the Holding Key is mounted on the switch body. Otherwise the Holding Key may deform or break. Stop using in case that deformation or breakage of the Holding Key occurs.
  • Use the provide Spring washers and Mounting screws when mounting the Holding Key. Fit a tip of a slotted-screw driver on the head of the Mounting screw as shown in the following figure when tightening Mounting screws. The Mounting screws cannot be released once tightened.
  • As shown in figure 1 in Precautions for Safe Use, install the D4NS so that its mounting surface is above the highest part of the A4EG.
  • As shown in figure 1 in the Precautions for Safe Use, use the Holding Key inserted vertically to the insert hole. Using the A4EG-BE2R041 (Enabling Grip Switch Equipped with an Emergency Stop Button) If the A4EG is installed in a machine, do not use the A4EG alone as an emergency stop switch or as an emergency shutoff switch as specified by SEMI-S2. SEMI-S2 specifies the installation of emergency shutoff switches at specified intervals on equipment. The A4EG can be removed from the equipment, and so may not satisfy the requirements of SEMI. Use the A4EG in combination with emergency stop switches or emergency shutoff switches that are installed at fixed positions. Wiring
  • Confirm that safety is satisfied on the operation of the equipment to wire.
  • Do not put the electric power when wiring. Otherwise electric shock may occur.
  • Use an adequate diameter of cable. The seal performance is reduced when the diameter is smaller than the adequate diameter.
  • Use the conforming sizes of lead wires to the apply voltage and current. Conforming cable size Recommended multi-wire cable size: A WG20 to 18 (0.5 to 0.75 mm Recommended cable diameter: 8.0 to 13 mm (used with provided Conduit Connector)
  • Do not pull the lead wires with excessive force. Doing so may disconnect them.
  • Do not pull the cable when the Enabling Switch Device is hung on the Bracket.
  • Use crimp terminals with insulator tube for wiring. Recommended crimp terminal (Ring tongue terminal, Nylon- N1.25-3.7 (Straight Type)
  • Cut and crimp the lead wires in length as shown in the following table. Otherwise, excess length may cause the cover to rise and not fit properly.
  • Do not let particles such as small piece of lead wire in the switch body when wiring. Terminal No. and Circuit Configuration
  • Assemble all of the parts without leaving any parts as shown in the following figure when mounting Conduit Connector. Mount Rubber packing, Conduit part, Cable Seal part and Spiral Nut part in order.
  • Both of the switches is ON when pushing the two push buttons simultaneously. Confirm that safety is satisfied on the operation of the equipment to wire. (A4EG-BM2B041)
  • Perform maintenance inspections periodically. Holding Key A4EG-OP3 (sold separately)A4EG Mounting screw, 2 pcs. (provided) Spring washer, 2 pcs. (provided) Length of lead wires Terminal No. 1-4 5-8 L1/L2 (Length to the centers of crimp terminals) 40±2 mm 25 ±2 mm Model Circuit Terminal No. A4EG-C000041 Enable output 1-2, 3-4 Grip output 5-6 A4EG-BE2R041 Enable output 1-2, 3-4 Emergency Stop Pushbutton Switch output 5-6, 7-8 A4EG-BM2B041 Enable output 1-2, 3-4 Pushbutton Switch output 5-6, 7-8 Bracket A4EG-OP2 (sold separately) L l F BD dia. dz dia. t: 0.8 mm dz dia.: 3.7 mm D dia.4.0 mm B: 5.5 mm L: 15.7 mm F: 4.0 mm I: 9.0 mm Terminal 1 Terminal 2 Terminal 3 Terminal 4 Terminal 5 Terminal 6 Terminal 7 Terminal 8 Terminal ArrangementLead Wire Lengths Conduit part Rubber packing Cable seal part Spiral nut part

Authorized Distributor: Note: Specifications subject to change without notice. Regional Headquarters Cat. No. C142-E1-01 Printed in Japan 1007-?M (1007) (?) OMRON Corporation Industrial Automation Company Safety Devices Division Shiokoji Horikawa, Shimogyo-ku, Kyoto, 600-8530 Japan OMRON EUROPE B.V. Wegalaan 67-69, NL-2132 JD Hoofddorp The Netherlands OMRON ASIA PACIFIC PTE. LTD. No. 438A Alexandra Road # 05-05/08 (Lobby 2), Alexandra Technopark, Singapore 119967 Tel: (65) 6835-3011/Fax: (65) 6835-2711 OMRON (CHINA) CO., LTD. Room 2211, Bank of China Tower,

200 Yin Cheng Zhong Road,

Pu Dong New Area, Shanghai, 200120, China Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200 OMRON SCIENTIFIC TECHNOLOGIES INC.

6550 Dumbarton Circle, Fremont

CA 94555-3605 U.S.A.