FEATURES

Š High efficiency: 85% @ 1.5V/ 35A Š Size: 57.9mmx36.8mmx12.7mm Š Standard footprint Š Industry standard pin out Š Fixed frequency operation Š Metal baseplate Š Input UVLO, Output OCP, OVP, OTP Š Basic insulation Š No minimum load required Š 2:1 Input voltage range Š ISO 9001, TL 9000, ISO 14001, QS9000, OHSAS18001 certified manufacturing facility Š UL/cUL 60950 (US & Canada) Recognized, and TUV (EN60950) Certified Š CE mark meets 73/23/EEC and 93/68/EEC directives Delphi Series Q48SL, 100W Quarter Brick Family DC/DC Power Modules: 48V in, 1.5V/35A out The Delphi Series Q48SL Quarter Brick, 48V input, single o utput, isolated DC/DC converter is the latest offering from a world leader in power system and technology and m anufacturing -- Delta Electronics, Inc. This product family provides up to 100 watts of power or 35A of output current (2.5V and below) in an industry standard footprint. With creativ e design technology and o ptimization of com ponent pla cement, these conve rters possess outstanding electrical and thermal performances, as well as extremely high reliability under hi ghly stressful operating conditions. All models are fully protected fro m abno rmal input/output voltage, current, and tem perature conditions. The Delphi Series converters meet all safety requirements with basic insulation. OPTIONS Š Positive On/Off logic Š Short pin lengths available

APPLICATIONS

Š Telecom/Datacom Š Wireless Networks Š Optical Network Equipment Š Server and Data Storage Š Industrial/Testing Equipment DATASHEET DS_Q48SL1R535_01192007

(TA=25°C, airflow rate=300 LFM, Vin=48Vdc, nominal Vout unless otherwise noted.) PARAMETER NOTES and CONDITIONS Q48SL1R535 (Standard) Min. Typ. Max. Units ABSOLUTE MAXIMUM RATINGS Input Voltage Continuous 80 Vdc Transient (100ms) 100ms 100 Vdc Operating Temperature Refer to Fig.21 for measuring point -40 100 °C Storage Temperature -55 125 °C Input/Output Isolation Voltage 1 minute 1500 Vdc INPUT CHARACTERISTICS Operating Input Voltage 36 48 75 Vdc Input Under-Voltage Lockout Turn-On Voltage Threshold 33 34 35 Vdc Turn-Off Voltage Threshold 31 32 33 Vdc Lockout Hysteresis Voltage 1 2 3 Vdc Input Over-Voltage Lockout Turn-Off Voltage Threshold 81 Vdc Turn-On Voltage Threshold 79 Vdc Maximum Input Current 100% Load, 36Vin 2.1 A No-Load Input Current 100 150 mA Off Converter Input Current 3 10 mA Inrush Current(I2t) 0.015 A2s Input Reflected-Ripple Current P-P thru 12µH inductor, 5Hz to 20MHz 10 mA Input Voltage Ripple Rejection 120 Hz 55 dB OUTPUT CHARACTERISTICS Output Voltage Set Point Vin=48V, Io=Io.max, Tc=25℃ 1.47 1.50 1.53 Vdc Output Voltage Regulation Over Load Io=Io,min to Io,max ±2 ±5 mV Over Line Vin=36V to 75V ±2 ±5 mV Over Temperature Tc=-40℃ to 100℃ ±15 ±50 mV Total Output Voltage Range over sample load, line and temperature 1.43 1.57 V Output Voltage Ripple and Noise 5Hz to 20MHz bandwidth Peak-to-Peak Full Load, 1µF ceramic, 10µF tantalum 70 110 mV RMS Full Load, 1µF ceramic, 10µF tantalum 20 40 mV Operating Output Current Range 0 35 A Output DC Current-Limit Inception Output Voltage 10% Low 110 150 % DYNAMIC CHARACTERISTICS Output Voltage Current Transient 48V, 10µF Tan & 1µF Ceramic load cap, 0.1A/µs Positive Step Change in Output Current 50% Io.max to 75% Io.max 150 mV Negative Step Change in Output Current 75% Io.max to 50% Io.max 150 mV Settling Time (within 1% Vout nominal) 300 us Turn-On Transient Start-Up Time, From On/Off Control 5 10 ms Start-Up Time, From Input 5 10 ms Maximum Output Capacitance Full load; 5% overshoot of Vout at startup 10000 µF EFFICIENCY 100% Load 85 % 60% Load 86.5 % ISOLATION CHARACTERISTICS Input to Output 1500 Vdc Input to Case 1500 Vdc Output to Case 500 Vdc Isolation Resistance 10 MΩ Isolation Capacitance 1200 pF FEATURE CHARACTERISTICS Switching Frequency 230 kHz ON/OFF Control, Negative Remote On/Off logic Logic Low (Module On) Von/off at Ion/off=1.0mA 0 0.8 V Logic High (Module Off) Von/off at Ion/off=0.0 µA 2.4 15 V ON/OFF Control, Positive Remote On/Off logic Logic Low (Module Off) Von/off at Ion/off=1.0mA 0 0.4 V Logic High (Module On) Von/off at Ion/off=0.0 µA 2.4 15 V ON/OFF Current (for both remote on/off logic) Ion/off at Von/off=0.0V 1 mA Leakage Current (for both remote on/off logic) Logic High, Von/off=15V 50 uA Output Voltage Trim Range Across Pins 9 & 5, Pout ≦ max rated power -20 +10 % Output Voltage Remote Sense Range Pout ≦ max rated power +10 % Output Over-Voltage Protection Over full temp range; % of nominal Vout 115 122 130 % GENERAL SPECIFICATIONS MTBF Io=80% of Io, max; Tc=40°C 2.5 M hours Weight 55 grams Over-Temperature Shutdown Refer to Fig.21 for measuring point 110 °C DS_Q48SL1R535_01192007

The impe dance of the i nput so urce conn ecting to the DC/DC power modules will interact with the modul es and affect the st ability. A low ac-imp edance input so urce is recommended. If the source inductance is more than a few µH, we advise adding a 10 to 100 µF electrolytic capacitor (ESR < 0.7 Ω at 100 kHz) mounted close to the input of the module to improve the stability. Layout and EMC Considerations Delta’s DC/DC power modules are designed to operate in a wide vari ety of systems and appli cations. Fo r desi gn assistance wi th EMC com pliance and related PWB layou t issues, please c ontact Delt a’s tec hnical s upport team. An external inpu t filter module is available for easier EMC compliance d esign. Application note s to assi st desi gners in addressing these issues are pending release. Safety Considerations The power module must be installed in compliance with the spacing and sep aration requi rements of the end-user ’s safety agency standard, i.e., UL60950, CAN/CSA-C22.2 No. 60950-00 an d EN60 950:2000 a nd IEC6095 0-1999, if the system in which the power module is to be used must meet safety agency requirements. Basic insulation based on 75 Vdc input is provided between the input and output of the module for the purp ose o f applying insulation req uirements whe n the input to this DC-to-DC co nverter is id entified as TNV-2 or SEL V. An additional evaluation is n eeded if the source is other than TNV-2 or SELV. When the in put sou rce is SEL V circuit , the powe r module meets SELV (safety extra-low voltage) requirements. If the input source is a hazardous voltage which is greater than 60 Vdc and less than or equal to 75 Vdc, for the module’s output to meet SELV requirements, all of the following must be met: The input source must be insulated from the ac mains by reinforced or double insulation. The input terminals of the module are not operato r accessible. If the metal baseplate is grounded, one Vi pin and one Vo pin shall also be grounded. A SELV reliability test is conducted on the system where the module i s u sed, in com bination with the module, to e nsure that u nder a single fault, hazardou s voltage does not appear at the module’s output. When install ed into a Cla ss II equipment (wit hout grounding), spacing consideration should be given to the end-use installation, as the spacing between the mo dule and mounting surface have not been evaluated. The po wer module h as extra-low voltage (ELV ) o utputs when all inputs are ELV. This po wer module i s n ot internally fused. To a chieve optimum safety and system protection, an input line fuse is highly re commended. The safety a gencies req uire a normal-blow fuse with 20A maximum rating to be installed in the ungrou nded lead. A lower rate d fuse can be u sed based on the maximum inrush tran sient ene rgy and maximum input current. Soldering and Cleaning Considerations Post solder cleaning is usually the final board asse mbly process before the bo ard or system undergoes electrical testing. Inadequate cleaning and/or drying may lower the reliability of a power m odule and severely af fect the finished circu it board asse mbly test. Adequ ate clea ning and/or drying is especially important for un-encapsulated and/or open frame type power modules. For assistance on appropriate solderi ng and cleaning p rocedures, pl ease contact Delta’s technical support team. DS_Q48SL1R535_01192007

Pin No. Name Function -Vin ON/OFF +Vin +Vout +SENSE TRIM -SENSE -Vout Negative input voltage Remote ON/OFF Positive input voltage Positive output voltage Positive remote sense Output voltage trim Negative remote sense Negative output voltage Pin Specification: Pins 1-4, 6-8 1.00mm (0.040”) diameter Pins 5 & 9 1.50mm (0.059”) diameter All pins are copper with Tin plating. DS_Q48SL1R535_01192007

DS_Q48SL1R535_01192007 PART NUMBERING SYSTEM Q 48 S L 1R5 35 N R F A Type of Product Input Voltage Number of Outputs Product Series Output Voltage Output Current ON/OFF Logic Pin Length Option Code Q- Quarter Brick 48V S- Single L – IMS, Positive trim 1R5-1.5V 35-35A N-Negative P-Positive R-0.170” N-0.145” K-0.110” F- RoHS 6/6 (Lead Free) A-Standard Functions MODEL LIST Part Number INPUT OUTPUT EFF @ 100% LOAD Q48SL1R535NRFA 36V~75V 2.1A 1.5V 35A 85% Q48SL1R835NRFA 36V~75V 2.5A 1.8V 35A 87% Q48SL2R535NRFA 36V~75V 3.3A 2.5V 35A 89% Q48SL3R330NRFA 36V~75V 3.7A 3.3V 30A 91% Q48SL05020NRFA 36V~75V 3.7A 5.0V 20A 90% Q48SL12010NRFA 36V~75V 4.4A 12V 10A 91% Default remote on/off logic is negative and pin length is 0.170” For different remote on/off logic and pin length, please refer to part numbering system above or contact your local sales CONTACT: www.delta.com.tw/dcdc USA: Telephone: East Coast: (888) 335 8201 West Coast: (888) 335 8208 Fax: (978) 656 3964 Email: DCDC@delta-corp.com Europe: Phone: +41 31 998 53 11 Fax: +41 31 998 53 53 Email: DCDC@delta-es.com Asia & the rest of world: Telephone: +886 3 4526107 ext 6220 Fax: +886 3 4513485 Email: DCDC@delta.com.tw WARRANTY Delta offers a two (2) year limited warrant y. Complete warranty information is list ed on our web site or is available upon request from Delta. Information furnished by Delta is believed to be accurate and reliable. However, no responsibility is assumed by Delta for its use, nor for any infringements of patents or other rights of third parties, which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of Delta. Delta reserves the right to revise these specifications at any time, without notice.