A4558 AUK | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 4
Technical content
Features
- Power consumption as small as about 50mW (typ.)
- Built-in output short-circuit protecting circuit.
- Internal phase consumption type.
- No latch-up
- Wide same phase mode and differential voltage ranges
- High gain. low noise
Applications
- Active filters
- Audio amplifiers
- VCOs
- Other electronic circuits
Ordering Information
Type NO. Marking Package Code A4558 A4558 SOP-8 O u t l i n e D i m e n s i o n s u n i t : mm SSeemmiiccoonndduuccttoorr Block Diagram
Characteristic Symbol Ratings Unit Supply voltage V CC 20 or ±10 V Differential input voltage V IND 20 V Input voltage V IN ±10 V Power Dissipation P D 300 mW Operating temperature Topr -45 ~ +85 °C Storage temperature Tstg -55 ~ +150 °C
Electrical Characteristics
(Unless otherwise specified. VCC = +5V, VEE=-5V and Ta = 25 °C) Parameter Symbol Test Conditions Min. Typ. Max. Unit Input Offset Voltage V IOS Rg≤ 10 ㏀ 0 0.5 6 mV Input Offset Current I IOS - - 5 200 nA Input Bias Current I IB - - 60 500 nA Input Common Mode Voltage Range VICR - ±5 ±7 - V Maximum Output Voltage V OM Common Mode Rejection Ratio CMRR Rg≤ 10 ㏀ 70 90 - dB Power Supply Rejection Ratio PSRR Rg≤ 10 ㏀ - 30 150 uV/V Supply Current I CC - - 3 6 mA Slew Rate SR RL≥2㏀ - 2 - V/us Unity Gain Cross Frequency f T Open Loop - 3 - MHz Large Signal Voltage Gain G V V CC=8V, VEE=-8V, RL=2K 86 100 - dB Output Sink Current I SINK - 15 25 - mA Output Source Current I SOURCE - 15 25 - mA
Electrical Characteristic Curves Fig. 4 V OM-Vcc, VEE Fig. 3 IIB - Ta Fig. 1 GV - f Fig. 2 VOPP -f
These AUK products are intended for usage in general electronic equipments(Office and communication equipment, measuring equipment, domestic electrification, etc.). Please make sure that you consult with us before you use these AUK products in equipm- ents which require high quality and/or reliabi lity, and in equipments which could have major impact to the welfare of human life(atomic energy control, airplane, spaceship, traffic signal, combustion central, all types of safety device, etc.). AUK cannot accept liability to any damage which may occur in case these AUK products were used in the mentioned equipments without prior consultation with AUK.