AC-3 ABB | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 25
Technical content
M R R 2...6.3 E16 DU ... -10 7.5...11 10...14 13...19 18...25 24...32 TA 25 DU ... 22...32 29...42 TA 42 DU ... A 9A 12 A 16 A 26 A 30 A 40 AL 9A L 12 AL 16 AL 26 AL 30 AL 40 a.c. Circuit Switching Switched-on current Switched-off current = In Time Time Switched-off current = In Switched-on current 6 x In a.c. Circuit Switching Switching of 3-phase Cage Motors IEC AC-3 Power θ < 55 °C, 400 V kW 4 5.5 7.5 11 15 18.5rating Rated θ < 55 °C, 400 V A 91 2 1 72 6 3 2 3 7 AC-3 operational θ < 55 °C, 415 V A 91 2 1 72 6 3 2 3 7 current θ < 55 °C, 690 V A 79 1 0 1 7 * 21* 25* Switching of Resistive Circuits IEC * For AL 26 ... AL 40 see "Technical Data" Rated θ < 40 °C, 690 V A 25 27 30 45 55 60 AC-1 operational θ < 55 °C, 690 V A 22 25 27 40 55 60 current θ < 70 °C, 690 V A 18 20 23 32 39 42
- With conductor cross-sectional area mm2 2.5 4 4 6 10 16
- Rated operational voltage V 690 UL/CSA 3-phase Motor-rating Motor-rating 480 V hp 5 7.5 10 20 25 30 General Use Rating Amp-rating 600 V A 21 25 30 40 50 60 Nema Size 00 0 – 11 P – AC-3 utilization category When making , the motor current is about 6 x In. Breaking while the motor is running at In motor F.L.C. AC-1 utilization category When making , the switched-on current is equal to the In load rated current with cos ϕ ≥ 0.95. TP 40 DA, TP 180 DA Direct timing - Front mounting TP 40 IA, TP 180 IA TE5S Direct timing - Separate mounting VE 5-1 VM 5-1 RV 5 RC 5-1 RT 5 1 x N.O. 1 x N.C. A 9-30-10 A 26-30-10 a.c. Control supply range Types A 12-30-10 A 30-30-10 AL 9-30-10 AL 26-30-10 d.c. Control supply range Types AL 12-30-10 AL 30-30-10 CA 5-10 1-pole, front mounting CA 5-01 1-pole, front mounting Selection & Ordering Select accessory type and quote required data in plain text. Selection & Ordering Select contactor type. Select contactor coil voltage on cover folding page 0/1, according to control circuit supply. (Please quote coil voltage in plain text). Note: The AF contactor range, with a.c./d.c. Electronic Coil Interface, is available from AF 50 up to AF 1650. Timers TP.., Pneumatic TE.., Electronic Supply voltages: 24 V a.c./d.c., Interlocks VE 5-., Mechanical / Electrical Types VM..., Mechanical mounting between 2 contactors suppressors RC.., (Capacitor) a.c. Types RT.., (Transil diode) d.c. Contactor Main Accessories Contactor Main Accessories 3-pole Contactors3-pole Contactors Selection & Ordering Select O/L relay type and setting range according to motor F.L.C. setting range in Amps >> Description pages 2/6, 2/10 2/18, 2/20 2/14 2/14 2/34, 2/38 2/44 2/46 >> Ordering Details pages 2/7, 2/11 2/19, 2/21 2/15, 2/16 2/15, 2/16 2/35, 2/39 2/45 2/47 O/L relays TA..DU.., Thermal O/L relay Types E..DU.., Electronic O/L relay Standard starting time 2 ... 10 s tripping class 10 A Protection of 3-phase motorsProtection of 3-phase motors For further information: For further information: Auxiliary CA 5-.., 1-pole, Types contacts CAL ..-.., 2-pole Page extracted from eCatalogue: Contactors - Sales Engineer Version - Page 2 of 25
250...800 E 200 DU TA 75 DU ... 29...42 36...52 45...63 60...80 60...80 65... 90 80...110 TA 200 DU ... 130...175 150...200 60...200 TA 450 DU ... 165...235 220...310 E 320 DU E 800 DU TA 80 DU ... TA 110 DU ... 375...1250 E 1250 DU bar / mm A 50 A 63 A 75 A 95 A 110 A 145 A 185 A 210 A 260 A 300 AF 400 AF 460 AF 580 AF 750 AF 1350 AF 1650AE 50 AE 63 AE 75 AE 95 AE 110 AF 145 AF 185 AF 210 AF 260 AF 300 bar / mm bar / mm 22 30 37 45 55 75 90 110 140 160 200 250 315 400 475 560 50 65 75 96 110 145 185 210 260 305 400 460 580 750 860 1050 50 65 75 96 110 145 185 210 260 300 400 460 580 750 860 1050 35 43 46 65 82 120 170 210 220 280 350 400 500 650 800 950 100 115 125 145 160 250 275 350 400 500 600 700 800 1050 1350 1650 85 95 105 135 145 230 250 300 350 400 500 600 700 875 1150 1450 70 80 85 115 130 180 180 240 290 325 400 480 580 720 1000 1270 35 50 50 50 70 120 150 185 240 300 2 x 185 2 x 240 2x240 2x50x8 2//100x5 3//100x5 1000 690 1000 40 60 60 60 75 100 125 150 200 250 350 400 500 600 800 900 80 90 105 125 140 230 250 300 350 400 550 650 750 900 1350 1650 Inverse timing - Front mounting – TE5S Direct timing - Separate mounting TE5S Sep. mounting RV 5 RC 5-2 RT 5 VE 5-2 VM 300H VM 750H A 50-30-00 A 95-30-00 A 145-30-11 A 210-30-11 AF 400-30-11 AF 580-30-11 AF 1350-30-11 A 63-30-00 A 110-30-00 A 185-30-11 A 260-30-11 AF 460-30-11 AF 750-30-11 AF 1650-30-11 A 75 30-00 A 300-30-11 AE 50-30-00 AE 95-30-00 AF 145-30-11 AF 210-30-11 AF 400-30-11 AF 580-30-11 AF 1350-30-11 AE 63-30-00 AE 110-30-00 AF 185-30-11 AF 260-30-11 AF 460-30-11 AF 750-30-11 AF 1650-30-11 AE 75-30-00 AF 300-30-11 CAL 5-11 2-pole, side mounting VM 1650H The AF 50 ... AF 1650 contactors are equipped with a built-in electronic coil interface which eliminates the need of extra surge suppressors - For A 145 ... A 300 use RC-EH 300 about: Information about: CAL 18-11 2-pole, side mounting CAL 18-11 B (1st block) (2 nd block) 3-pole Contactors 3-pole Contactors Page extracted from eCatalogue: Contactors - Sales Engineer Version - Page 3 of 25
A 9 ... A 110 3-pole Contactors a.c. Operated Application
Description
The A... series 3-pole contactors are of the block type design.
- Main poles and auxiliary contact blocks A 9 ... A 40 1-stack contactors: –3 main poles, –1 built-in auxiliary contact, – front and side mounted add-on auxiliary contact blocks. A 9 ... A 40 2-stack contactors: –1 st stack with 3 main poles and 1 built-in auxiliary contact, –2 nd stack with 4 built-in auxiliary contacts, – side mounted add-on auxiliary contact blocks. The built-in auxiliary contact elements are mechanically linked. A 50 ... A 110 contactors: –3 main poles, – front and side mounted add-on auxiliary contact blocks.
- Control circuit: a.c. operated with laminated magnet circuit.
- Accessories: a wide range of accessories is available Variants
- magnetically latched contactors (AM... types). Location of surge suppressors. Clear marking of coil voltages and frequencies. Quick fixing on mounting rail according to IEC 60715, EN 60715 standards: – 35 x 7.5 mm for A 9 ... A 40 contactors, – 35 x 15 mm for A 9 ... A 75 contactors, – 75 x 25 mm for A 50 ... A 110 contactors. Location of side-mounted accessories (on right or left hand side). Holes for screw fixing (screws not supplied). Terminals delivered in open position with captive screws. Screwdriver guidance for all terminals. Degree of protection (IP...) of terminals according to IEC 60947-1: –A 9 ... A 40 contactors: IP 20 for main and auxiliary terminals. –A 50 ... A 110 contactors: IP 10 for main terminals, IP 20 for auxiliary terminals. Stops for attaching front mounted acces- sories. Location of function marker. Terminal marking according to IEC 60947-4-1, EN 50005, EN 50012 and NEMA standards. Connecting point for control leads in top part of main terminals of A 50 ... A 110 contactors Terminal screws: –A 9 ... A 16 contactors: M3.5 Pozidriv (+,-) No. 2 for all terminals, –A 26 contactors: M4 Pozidriv (+,-) No. 2 for main and auxiliary terminals, M3.5 Pozidriv (+,-) No. 2 for coil terminals, –A 30, A 40 contactors: M5 Pozidriv (+,-) No. 2 for main terminals, M3.5 Pozidriv (+,-) No. 2 for auxiliary and coil terminals, –A 50 ... A 75 contactors: M6 Pozidriv (+,-) No. 2 for main terminals, M3.5 Pozidriv (+,-) No. 2 for coil terminals, –A 95 ... A 110 contactors: M8 Hexagon socket (s = 4 mm) for main terminals, M3.5 Pozidriv (+,-) No. 2 for coil terminals. Page extracted from eCatalogue: Contactors - Sales Engineer Version - Page 4 of 25
IEC UL/CSA Auxiliary Type Order code Weight contacts kg Rated Rated 3-Phase General fitted power current motor use 1st stack 2 nd stack
400 V θ < 40°C rating rating
AC-3 AC-1 480 V 600 V state coil voltage state coil voltage code Packing kW A hp A (see table below) (see table below) 1 piece 1– –– A 9-30-10 1SBL 141 001 R 10 0.340 42 552 1 –1 –– A 9-30-01 1SBL 141 001 R 01 0.340 –– 22 A 9-30-22 1SBL 141 001 R 22 0.400 1– 22 A 9-30-32 1SBL 141 001 R 32 0.400 1– –– A 12-30-10 1SBL 161 001 R 10 0.340 5.5 27 7.5 25 –1 –– A 12-30-01 1SBL 161 001 R 01 0.340 –– 22 A 12-30-22 1SBL 161 001 R 22 0.400 1– 22 A 12-30-32 1SBL 161 001 R 32 0.400 1– –– A 16-30-10 1SBL 181 001 R 10 0.340 7.5 30 10 30 –1 –– A 16-30-01 1SBL 181 001 R 01 0.340 –– 22 A 16-30-22 1SBL 181 001 R 22 0.400 1– 22 A 16-30-32 1SBL 181 001 R 32 0.400 1– –– A 26-30-10 1SBL 241 001 R 10 0.600 11 45 20 40 – 1 – – A 26-30-01 1SBL 241 001 R 01 0.600 1– 22 A 26-30-32 1SBL 241 001 R 32 0.660 1– –– A 30-30-10 1SBL 281 001 R 10 0.710 15 55 25 50 – 1 – – A 30-30-01 1SBL 281 001 R 01 0.710 1– 22 A 30-30-32 1SBL 281 001 R 32 0.770 1– –– A 40-30-10 1SBL 321 001 R 10 0.710 18.5 60 30 60 – 1 – – A 40-30-01 1SBL 321 001 R 01 0.710 1– 22 A 40-30-32 1SBL 321 001 R 32 0.770 –– –– A 50-30-00 1SBL 351 001 R 00 1.160 22 100 40 80 1 1 – – A 50-30-11 1SBL 351 001 R 11 1.200 –– 22 A 50-30-22 1SBL 351 001 R 22 1.230 –– –– A 63-30-00 1SBL 371 001 R 00 1.160 30 115 60 90 1 1 – – A 63-30-11 1SBL 371 001 R 11 1.200 –– 22 A 63-30-22 1SBL 371 001 R 22 1.230 –– –– A 75-30-00 1SBL 411 001 R 00 1.160 37 125 60 105 1 1 – – A 75-30-11 1SBL 411 001 R 11 1.200 –– 22 A 75-30-22 1SBL 411 001 R 22 1.230 –– –– A 95-30-00 1SFL 431 001 R 00 2.000 45 145 60 125 1 1 – – A 95-30-11 1SFL 431 001 R 11 2.040 –– 22 A 95-30-22 1SFL 431 001 R 22 2.070 –– –– A 110-30-00 1SFL 451 001 R 00 2.000 55 160 75 140 1 1 – – A 110-30-11 1SFL 451 001 R 11 2.040 –– 22 A 110-30-22 1SFL 451 001 R 22 2.070 Coil voltages and codes Voltage Voltage Code V - 50Hz V - 60Hz 24 24 8 1 48 48 8 3 110 110 ... 120 8 4 Other voltages: page 0/1. A 9 ... A 110 3-pole Contactors a.c. Operated 3-pole Contactors3-pole Contactors Page extracted from eCatalogue: Contactors - Sales Engineer Version - Page 5 of 25
RV 5/.. CAL 5-11 TA 25 DU.. A 26-30-10 CA 5-10 CA 5-31M TP 40 DA A 9 ... A 110 3-pole Contactors Main Accessories Fitting Details - For Ordering Details, see "Accessories" Many configurations of accessories are possible depending on whether these are front mounted or side mounted. Contactor Main Available Front mounted accessories Side mounted accessories types poles auxiliary contacts Auxiliary contact Auxiliary contact 1-pole CA 5-.. Auxiliary contact Pneumatic timer 2-pole CAL.. Interlock unit A 9 ... A 16 3 0 2 2 –– –1 to 2 x CAL 5-11 or 1 x VM 5-1 or VE 5-1 A 9 ... A 26 3 0 3 2 + 1 x CAL 5-11 A 30, A 40 3 0 1 0 1 to 5 x CA 5-.. or 1 x CA 5-.. (4-pole) or 1 x TP .. A + 1 to 2 x CAL 5-11 or 1 x VM 5-1 or VE 5-1 A 30, A 40 3 0 3 2 (5) 1 x CA 5-.. –– + 1 to 2 x CAL 5-11 or 1 x VM 5-1 or VE 5-1 (or 1 x CE 5-..) (4) + 1 x CAL 5-11 or 1 x TP .. A + 1 to 2 x CAL 5-11 or 1 x VE 5-2 (1 to 2 x CE 5-.. max.) + 1 x CAL 5-11 A 95, A 110 3 0 0 0 1 to 6 x CA 5-.. or 1 x CA 5-.. (4-pole) – + 1 to 2 x CAL 18-11 or 1 x VE 5-2 A 95, A 110 3 0 1 1 1 to 6 x CA 5-.. or 1 x CA 5-.. (4-pole) A 95, A 110 3 0 2 2 1 to 2 x CA 5-.. –– + 1 to 2 x CAL 18-11 or 1 x VE 5-2 (4) CE 5-.. auxiliary contacts not allowed in mounting position 5. (6) A 9, A 12, A 16-30-01 in mounting position 5, TP..DA not allowed. Contactor and main accessories For mounting position diagram, see "Technical Data" (other accessories available) The accessories provided for the A 50 ... A 110 contactors can be used for the AF 50 ... AF 110 types. Page extracted from eCatalogue: Contactors - Sales Engineer Version - Page 6 of 25
RV 5/.. CAL 5-11 TA 25 DU.. A 26-30-10 CA 5-31M TP 40 DA CA 5-10 VE 5-1 Fitting Details - For Ordering Details, see "Motor Protection" The addition of a thermal O/L relay on the contactor does not prevent fitting of many other accessories as shown below. Contactor Thermal O/L relays - No mounting kit required, direct mounting types TA 25 DU.. TA 42 DU TA 75 DU TA 80 DU TA 110 DU A 30, A 40 TA 25 DU.. (1) or TA 42 DU.. (1) ––– A 95, A 110 –– – TA 80 DU.. (1) or TA 110 DU.. (1) (1) According to the current value. Contactor and O/L relay The O/L relays provided for the A 50 ... A 110 contactors can be used for the AF 50 ... AF 110 types. A 9 ... A 110 3-pole Contactors Thermal O/L Relays 3-pole Contactors3-pole Contactors Page extracted from eCatalogue: Contactors - Sales Engineer Version - Page 7 of 25
M M Technical Data Main Pole - Utilization Characteristics acc. to IEC Contactor types: A... 9 12 16 26 30 40 45 50 63 75 95 110 Rated operational voltage Ue max. V 690 1000 (690 for AF ... contactors) 1000 Rated frequency limits Hz 25 ... 400 Conventional free-air thermal current Ith acc. to IEC 60947-4-1, open contactors, θ ≤ 40 °C A 26 28 30 45 65 65 100 100 125 125 145 160 with conductor cross-sectional area mm2 4 446 1 6 16 35 35 50 50 50 70 Rated operational current Ie / AC-1 for air temperature close to contactor θ ≤ 40 °CA 2 5 27 30 45 55 60 70 100 115 125 145 160 Ue max. 690 V - 50/60 Hz θ ≤ 55 °C A 22 25 27 40 55 60 60 85 95 105 135 145 θ ≤ 70 °C (3) A 18 20 23 32 39 42 50 70 80 85 115 130 with conductor cross-sectional area mm2 2.5 4 4 6 10 16 25 35 50 50 50 70 Utilization category AC-3 for air temperature close to contactor < 55 °C Max. rated operational current I e AC-3 (1) 220-230-240 V A 91 2 1 72 6 3 34 04 05 3 6 57 5 9 6 1 1 0 3-phase motors 380-400 V A 91 2 1 72 6 3 23 73 75 0 6 57 5 9 6 1 1 0
415 V A 91 2 1 72 6 3 23 73 75 0 6 57 5 9 6 1 1 0
440 V A 91 2 1 62 6 3 23 73 74 5 6 57 0 9 3 1 0 0
500 V A 91 2 1 42 2 2 83 33 34 5 5 56 5 8 0 1 0 0
690 V A 79 1 0 1 7 (4) 21 (4) 25 (4) 25 35 43 46 65 82
Rated operational power AC-3 (1) 1500 r.p.m. 50 Hz 220-230-240 V kW 2.2 3 4 6.5 9 11 11 15 18.5 22 25 30 3-phase motors 415 V kW 4 5.5 9 11 15 18.5 18.5 25 37 40 55 59 440 V kW 4 5.5 9 15 18.5 22 22 25 37 40 55 59 500 V kW 5.5 7.5 9 15 18.5 22 22 30 37 45 55 59 690 V kW 5.5 7.5 9 15 (4) 18.5 (4) 22 (4) 22 30 37 40 55 75 Rated operational current Ie / AC-8a without thermal O/L relay - Ue 400 V - θ ≤ 40 °C A 12 16 22 30 40 50 – 63 85 95 120 140 Rated making capacity AC-3 10 x Ie AC-3 acc. to IEC 60947-4-1 Rated breaking capacity AC-3 8 x Ie AC-3 acc. to IEC 60947-4-1 Short-circuit protection for contactors without thermal O/L relay - Motor protection excluded (2) Ue < 500 V a.c. - gG type fuse A 25 32 32 50 63 80 100 125 160 160 200 Rated short-time withstand current Icw at 40 °C ambient temp., 1 s A 250 280 300 400 600 1000 1320 1320 in free air, 10 s A 100 120 140 210 400 650 800 800 from a cold state 30 s A 60 70 80 110 225 370 500 500 1 min A 50 55 60 90 150 250 350 350 15 min A 26 28 30 45 65 110 110 135 135 160 175 Maximum breaking capacity (5) cos ϕ = 0.45 at 440 V A 250 420 820 (5) 900 1300 1160 (cos ϕ = 0.35 for Ie > 100 A) at 690 V A 90 (5) 170 (5) 340 (5) 490 630 800 Max. electrical switching frequency – for AC-2, AC-4 cycles/h 300 150 150 Mechanical durability – max. switching frequency cycles/h 3600 (300 for AF ... contactors) (1) For the corresponding kW/A or hp/A values of motors, see "Motor Rated Operational Powers and Currents". (2) For the protection of motor starters against short circuits, see "Coordination with Short-circuit Protection Devices". (6) AF... contactors excluded. Technical Data Types AL 26 AL 30 AL 40 TAL 26 TAL 30 TAL 40 Rated current Ie A 13 18 21 Rated power kW 11 15 18.5 Types AL 9 ... AL 16 AL 26 AL 30, AL 40 TAL 9 ... TAL 16 TAL 26 TAL 30, TAL 40
440 V A 250 420 470
690 V A 100 106 175
Page extracted from eCatalogue: Contactors - Sales Engineer Version - Page 8 of 25
M M B2A A B1 E0202D1 ABB Main Pole - Utilization Characteristics acc. to UL/CSA Contactor types: A... 9 12 16 26 30 40 45 50 63 75 95 110 NEMA size 00 0–1 1 P –22 –3 – – General use rating Amp-rating 600 V A 21 25 30 40 50 60 80 80 90 105 125 140 3-phase motor rating Amp-rating (1) 220-240 V A 6.8 9.6 15.2 28 28 42 54 54 68 80 80 104 440-480 V A 7.6 11 14 27 34 40 52 52 77 77 77 96 550-600 V A 91 1 1 72 7 3 24 15 25 2 7 77 7 7 7 9 9 Motor power (1) 200-208 V hp 2 35 7.5 10 10 15 15 20 25 30 30 220-240 V hp 2 351 0 1 0 1 52 02 0 2 53 0 3 0 4 0 440-480 V hp 5 7.5 10 20 25 30 40 40 60 60 60 75 550-600 V hp 7.5 10 15 25 30 40 50 50 75 75 75 100 Short-circuit protection for contactors without thermal O/L relay - Motor protection excluded Fuse rating A 35 35 60 90 150 150 175 175 200 200 200 200 Fuse type, 600 V FRS-R J Max. electrical switching frequency General Technical Data Contactor types: A... 9 12 16 26 30 40 45 50 63 75 95 110 Rated insulation voltage Ui according to IEC 60947-4-1 V 1000 according to UL/CSA V 600 Rated impulse withstand voltage Uimp. kV 8 Standards Devices complying with IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1 Air temperature close to contactor see "Conditions for use", for control voltage limits and authorized mounting positions – fitted with thermal O/L relay °C -25 to +55 – without thermal O/L relay °C -40 to +70 (1) – for storage °C -60 to +80 -40 to +70 Climatic withstand acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II acc. to IEC 68-2-30 Operating altitude m < 3000 Shock withstand acc. IEC 60068-2-27 and EN 60068-2-27 Mounting position 1 1/2 sinusoidal shock for 11 ms: no change in contact position Shock Closed Open Closed Open Closed Open Note : for A 95,direction position position position position position position AE 95, TAE 95, AF 95 A 20 g 20 g 20 g 10 g 20 g 20 g A 110, AE110,B1 10 g 5 g 15 g 5 g 10 g 5 g (2) TAE110, AF 110B2 15 g 15 g 10 g 10 g 15 g (3) 15 g (3) contactors, these C1 20 g 20 g 20 g 8 g 20 g 20 g values are not valid C2 20 g 20 g 14 g 8 g 20 g 20 g for rail mounting. (3) 10 g for AF 45-22, AE 45-22, AF 75-22 and AE 75-22 Technical Data Page extracted from eCatalogue: Contactors - Sales Engineer Version - Page 9 of 25
Magnet System Characteristics for A... Contactors Contactor types: A... 9 12 16 26 30 40 45 50 63 75 95 110 Rated control circuit voltage Uc – at 50 Hz V 24 ... 690 – at 60 Hz V 24 ... 690 (at θ < 70 °C) Please also refer to "Conditions for Use" Drop-out voltage in % of Uc approx. 40 ... 65 % Coil consumption Average pull-in value 50 Hz VA 70 120 180 350
60 Hz VA 80 140 210 450
50/60 Hz(1) VA/VA 74/70 125/120 190/180 410/365 Average holding value 50 Hz VA/W 8/2 12/3 18/5.5 22/6.5 60 Hz VA/W 8/2 12/3 18/5.5 26/8 Operating time between coil energization and: between coil de-energization and: (1) 50/60 Hz coils: see "Coil Voltage Code Table". Magnet System Characteristics for AF... Contactors Contactor types: AF... – – – – – – 45 50 63 75 95 110 Rated control circuit voltage Uc Please also refer to "Conditions for Use" Drop-out voltage in % of Uc min. 55 % Coil consumption Average pull-in value 50 Hz VA 210 350
60 Hz VA 210 350
d.c. W 190 400 Average holding value 50 Hz VA/W 7/2.8 7/3.5 60 Hz VA/W 7/2.8 7/3.5 d.c. W 2.8 2 Operating time between coil energization and: between coil de-energization and: Technical Data Page extracted from eCatalogue: Contactors - Sales Engineer Version - Page 10 of 25
Built-in Auxiliary Contacts - Other auxiliary contacts see "Accessories" Utilization characteristics acc. to IEC Rated operational voltage Ue max. V 690 Conventional free air thermal current Ith - θ < 40 °C A 16 Rated frequency limits Hz 25 ... 400 Rated operational current Ie / AC-15 according to IEC 60947-5-1 24-127 V 50/60 Hz A 6 220-240 V 50/60 Hz A 4 380-440 V 50/60 Hz A 3
500 V 50/60 Hz A 2
690 V 50/60 Hz A 2
Rated operational current Ie / DC-13 according to IEC 60947-5-1 24 V d.c. A 6 (144 W) 48 V d.c. A 2.8 (134 W) 72 V d.c. A 2 (144 W) 110 V d.c. A 1.1 (121 W) 125 V d.c. A 1.1 (138 W) 220 V d.c. A 0.55 (121 W) 250 V d.c. A 0.55 (138 W) Making capacity acc. to IEC 60947-5-1 10 x Ie / AC-15 Breaking capacity acc. to IEC 60947-5-1 10 x Ie / AC-15 Short-circuit protection gG type fuse A 10 Rated short-time withstand current Icw for 1.0 s A 100 for 0.1 s A 140 Minimum switching capacity V / mA 17 / 5 (1) Non-overlapping time between N.O. and N.C. contacts ms > 2 Heat dissipation per pole at 6 A W 0.10 Utilization characteristics acc. to UL/CSA Max. rated voltage V 600 Pilot duty A 600, P 300 Technical Data Technical DataTechnical Data Page extracted from eCatalogue: Contactors - Sales Engineer Version - Page 11 of 25
Position 1 ± 30° +30° -30° Position 6 ABB ABB ABB ABB Mounting Characteristics Contactor types: A... 9 12 16 26 30 40 45 50 63 75 95 110 Mounting positions see "Conditions for use" Mounting distances The contactors can be assembled side by side - Except for TAL... contactors: see "Dimensions" Fixing on rail 35 x 7.5 mm 35 x 15 mm according to IEC 60715, EN 60715 35 x 15 mm 75 x 25 mm 75 x 25 mm by screws (not supplied) 2 x M4 2 x M6 Conditions for Use Sustainable utilization conditions for contactors involving at the same time the Mounting position, Ambient temperature and Control voltage operating limits are summarized in the table below. Contactor types: A..., 9 12 16 26 30 40 45 50 63 75 95 110 AE... – – – – – – 45 50 63 75 95 110 Control voltage / Ambient temperature (Position 6 unauthorized for > 55 °C unauthorized Contactor types: TAL... 9 12 16 26 30 40 – – – – – – Control voltage / Ambient temperature 1, 1 + 30°, 2, 3, 4, 5 > 55 °C unauthorized Mounting pos. 6 – unauthorized Contactor types: AF ... – – – – – – 45 50 63 75 95 110 Control voltage / Ambient temperature Mounting pos. 6 – – ––– –– unauthorized Notes for 4-pole contactors Whatever the coil voltage: Pos. 5 unauthorized for AL 9-22-00, AL 16-22-00, AL 26-22-00, TAL 9-22-00, TAL 16-22-00, T AL 26-22-00, A 45-22-00, AE 45-22-00, AF 45-22-00, A 75-22-00, AE 75-22-00, AF 75-22-00 contactors. For 60 Hz coil voltage: (only for devices fitted with CA 5-.. and CAL 5-11 auxiliary contacts or TP timer) –A 45-40-00, A 50-40-00 and A 75-40-00 contactors –A 45-22-00 and A 75-22-00 contactors For mounting position 6 or ambient temperature of 55 to 70 °C the information given on this page remains applicable. Mounting Positions (see the above table for authorized positions) Technical Data Page extracted from eCatalogue: Contactors - Sales Engineer Version - Page 12 of 25
Connecting Characteristics Contactor types: A... 9 12 16 26 30 40 45 50 63 75 95 110 Main terminals with cable clamp with double with single connector with single connector (13 x 10 mm) connector 2 x (5.6 x 6.5 mm) (14 x 14 mm) Main conductors (poles) Rigid with connector Bars or lugs L mm < 7.7 10 –––– –– 3 0 (2) Capacity acc. to UL/CSA AWG 10-18 8-12 4-8 1-8 6-2/0 Auxiliary conductors (built-in auxiliary terminals + coil terminals) Lugs L mm < 7.7 (1) 8 l mm > 3.7 (1) 3.7 Capacity acc. to UL/CSA AWG 18-14 Degree of protection acc. to IEC 60947-1 / Protection against direct contact in acc. with EN 50274 EN 60947-1 and IEC 60529 / EN 60529 – Main terminals IP 20 IP 10 – Coil terminals IP 20 – Built-in auxiliary terminals IP 20 – – – – – – Screw terminals (delivered in open position, screws of unused terminals must be tightened) Main terminals (+,-) pozidriv 2 screws hexagon socket M3.5 M4 M5 M6 M8 (s = 4 mm) Coil terminals M3.5 (+,-) pozidriv 2 screws with cable clamp Built-in auxiliary terminals (+,-) pozidriv 2 screws with cable clamp – – – – – – Tightening torque Main pole terminals – recommended Nm / lb.in 1.00 / 9 1.7 / 15 2.30 / 20 4.00 / 35 6.00 / 53 Coil terminals – recommended Nm / lb.in 1.00 / 9 – max. Nm 1.20 Built-in auxiliary terminals – recommended Nm / lb.in 1.00 / 9 1.7 / 15 1.00 / 9 – – – – – – (1) L < 8 and l > 3.7 for coil terminals - L < 10 and l > 4.2 for built-in auxiliary terminals. (2) With LW 110 enlargement piece: see "Accessories". Page extracted from eCatalogue: Contactors - Sales Engineer Version - Page 13 of 25
A50 ... A110-30-22 5L3 6T3 3L2 4T2 1L1 2T1 NO NO NC NC NC NC NO NO A9 ... A16-30-22 A50 ... A110-30-22 E0325D1 5L33L2A1 A2 6T34T2 1L1 2T1 NO NO NO NO NC NC NC NC NO NO A9 ... A40-30-32 E0324D1 A9 ... A40-30-32 1L1 3L2 5L3 2T1 4T2 6T3 A1 A2 NO NO NONCNC NO 21 31 43 53 22 32 44 54 E0342D1 E0619D1 A9 ... A16-30-22 1L1 3L2 5L3 2T1 4T2 6T3 A1 A2 NCNCNO NO 13 21 31 43 14 22 32 44 1L1 2T1 13X 21X 14X 22X 3L2 5L3 4T2 6T3 NC NO NO NC E0008D2 A50 ... A110-30-11 1L1 2T1 3L2 4T2 21X NC NC 22X 5L3 6T3 13X NO NO 14X E0012D1 A50 ... A110-30-11 1L1 2T1 3L2 4T2 5L3 6T3 NO NO E0306D1 A9 ... A40-30-10 1L1 2T1 3L2 4T2 5L3 6T3 NC NC E0305D1 A9 ... A40-30-01 E0341D1 A9 ... A40-30-01 1L1 3L2 5L3 2T1 4T2 6T3 A1 A2 NC NC E0340D1 A9 ... A40-30-10 1L1 3L2 5L3 2T1 4T2 6T3 A1 A2 NO NO 1L1 3L2 5L3 2T1 4T2 6T3 E0009D2 A50 ... A110-30-00 A50 ... A110-30-00 1L1 2T1 5L3 6T3 3L2 4T2 E0011D1 1L1 3L2 5L3 2T1 4T2 6T3 E2136D AF50 ... AF110-30-00 AF50 ... AF110-30-00 1L1 2T1 5L3 6T3 3L2 4T2 E2134D AF50 ... AF110-30-11 1L1 2T1 13X 21X 14X 22X 3L2 5L3 4T2 6T3 NC NO NO NC E2137D 1L1 2T1 3L2 4T2 21X NC NC 22X 5L3 6T3 13X NO NO 14X E2135D AF50 ... AF110-30-11 Terminal Marking and Positioning Standard devices without addition of auxiliary contacts Standard devices with factory mounted auxiliary contacts Other possible contact combinations with auxiliary contacts added by the user Standard devices without addition of auxiliary contacts Standard devices with factory mounted auxiliary contacts E2306DG Combination 1L1 3L2 5L3 2T1 4T2 6T3 A50 ... A75-30-00 1L1 3L2 5L3 2T1 4T2 6T3 CA5-10 NO 5L3 6T3 3L2 4T2 1L1 2T1 NC NC NO NO NO NO NO NO Combination 21 E0627DG 5L33L2A1 A2 6T34T2 1L1 2T1 43X NO 31X NC 21X NC 13X NO NO 14X NC 22X NC 32X NO 44X Combination 22 E0623DG 5L3 6T3 3L2 4T2 1L1 2T1 NC NC NO NO Combination 11 E0622DG 1L1 2T1 13X 21X 14X 22X 3L2 5L3 4T2 6T3 43X 31X 44X 32X 1L1 2T1 3L2 5L3 4T2 6T3 13X 21X 14X 22X NC NO NO NC 43X 31X 44X 32X NC NO NO NC E0621DG A50 ... A75-30-11 CAL5-11Combination 1L1 2T1 3L2 4T2 5L3 6T3 NO NO E2322DG Combination 10 E0625DG A9 ... A40-30-10 CA5-01 CA5-10Combination = ++ NC NO 1L1 3L2 5L3 2T1 4T2 6T3 A1 A2 NO NO NONC 1L1 3L2 5L3 2T1 4T2 6T3 A1 A2 NO NO A9 ... A40-30-10 CA5-01Combination = + NC E0620DG NO NC 1L1 3L2 5L3 2T1 4T2 6T3 A1 A2 NO NO 1L1 3L2 5L3 2T1 4T2 6T3 A1 A2 NO Page extracted from eCatalogue: Contactors - Sales Engineer Version - Page 14 of 25
41.5 E0113D E0757D4.5 ø 4.5 4.5 E0101D (M4) 5.5 4 10 35 mm EN/IEC 60715 E0103D 100.5 5.5 35 mm EN/IEC 60715 E0107D 5.5 4 10 35 mm EN/IEC 60715 E0109D 107 5.5 35 mm EN/IEC 60715 E0105D 5.5 4 10 35 mm EN/IEC 60715 E0756D 127 5.5 35 mm EN/IEC 60715 E0114D 145 5.5 35 mm EN/IEC 60715 E0758D A 9, A 12 and A 16 3-pole Contactors Dimensions (in mm) A 9, A 12, A 16 A 9, A 12, A 16 + CA 5 front-mounted 1-pole auxiliary contact block A 9, A 12, A 16 A 9, A 12, A 16 + CAL 5 side-mounted 2-pole auxiliary contact block + CA 5 front-mounted 4-pole auxiliary contact block and corresponding 2-stack versions A 9, A 12, A 16 A 9, A 12, A 16 + RA 5 interface relay + TP pneumatic timer A 9, A 12, A 16 drilling plan A 9, A 12, A 16 + WB 75-A on-position latch Page extracted from eCatalogue: Contactors - Sales Engineer Version - Page 15 of 25
4.5 4.5 35 59 (M4) E0110D1 ø 4.5 103 E0115D 4.5 4.5 35 59 (M4) E0110D1 ø 4.5 133 E0759D 35 mm EN/IEC 60715 E0760D95 14* 4.5 ø 4.5 4.5 E0101D (M4) 5.5 4 10 35 mm EN/IEC 60715 E0112D 74.5 5.5 4 10 35 mm EN/IEC 60715 E0116D A 9, A 12 and A 16 3-pole Contactors Dimensions (in mm) A 9, A 12, A 16 + VE 5-1 electrical and mechanical interlock unit A 9, A 12, A 16 + VM 5-1 mechanical interlock unit A 9, A 12, A 16 + TA 25 DU thermal O/L relay * For TA 25 DU 32 only Page extracted from eCatalogue: Contactors - Sales Engineer Version - Page 16 of 25
93.6 96 . 3 4 10 35 mm EN/IEC 60715 E0119D 54 E0122D 119.8 35 mm EN/IEC 6 0715 E0123D E0124D 93.6 96 . 3 4 10 35 mm EN/IEC 60715 E0125D E0120D 126.3 9 10 35 mm EN/IEC 60715 E0121D E0761D 41.5 93.6 6.3 4 10 35 mm EN/IEC 60715 E0762D E0131D 146.3 91 0 35 mm EN/IEC 60715 E0132D ø4 . 2 4.54.5 70 80 E0117D (M4) E0763D 4 10 35 mm EN/IEC 60715 E0764D 164.3 A 26 3-pole Contactor Dimensions (in mm) A 26 A 26 + CA 5 front-mounted 1-pole auxiliary contact block A 26 A 26 + CAL 5 side-mounted 2-pole auxiliary contact block + CA 5 front-mounted 4-pole auxiliary contact block and corresponding 2-stack versions A 26 A 26 + RA 5 interface relay + TP pneumatic timer A 26 drilling plan A 26 + WB 75-A on-position latch Page extracted from eCatalogue: Contactors - Sales Engineer Version - Page 17 of 25
93.6 96 . 3 4 10 35 mm EN/IEC 60715 E0128D 4.5 45 4.5 80 E0126D (M4) ø 4.2 4.5 45 4.5 80 E0126D (M4) ø 4.2 123 E0129D 93.6 9 6.3 4 10 35 mm EN/IEC 60715 E0130D 147 E0765D 109.4 14* 15.4 93.6 E0766D 35 mm EN/IEC 60715 ø4 . 2 4.54.5 70 80 E0117D (M4) A 26 3-pole Contactor Dimensions (in mm) A 26 + VE 5-1 electrical and mechanical interlock unit A 26 + VM 5-1 mechanical interlock unit A 26 + TA 25 DU thermal O/L relay * For TA 25 DU 32 only Page extracted from eCatalogue: Contactors - Sales Engineer Version - Page 18 of 25
108.3 9 6.3 4 10 35 mm EN/IEC 60715 E0134D E0137D 134.5 35 mm EN/IEC 60715 E0138D E0139D 108.3 9 6.3 4 10 35 mm EN/IEC 60715 E0140D E0135D 141 35 mm EN/IEC 60715 E0136D 41.5 E0767D 108.3 6.3 4 10 35 mm EN/IEC 60715 E0768D 54 E0144D 161 35 mm EN/IEC 60715 E0145D ø4 . 2 4.54.5 70 80 E0117D (M4) E0769D 4 10 35 mm EN/IEC 60715 E0770D 179 A 30 and A 40 3-pole Contactors Dimensions (in mm) A 30, A 40 A 30, A 40 + CA 5 front-mounted 1-pole auxiliary contact block A 30, A 40 A 30, A 40 + CAL 5 side-mounted 2-pole auxiliary contact block + CA 5 front-mounted 4-pole auxiliary contact block and corresponding 2-stack versions A 30, A 40 A 30, A 40 + RA 5 interface relay + TP pneumatic timer A 30, A 40 drilling plan A 30, A 40 + WB 75-A on-position latch Page extracted from eCatalogue: Contactors - Sales Engineer Version - Page 19 of 25
108.3 9 6.3 4 10 35 mm EN/IEC 60715 E0143D 4.5 45 4.5 80 E0126D (M4) ø 4.2 123 E0146D 108.3 9 6.3 4 10 35 mm EN/IEC 60715 E0147D 4.5 45 4.5 80 E0126D (M4) ø 4.2 149.5 E0771D 108.3 9.7 103.7 35 mm EN/IEC 60715 14* E0772D ø4 . 2 4.54.5 70 80 E0117D (M4) 155.5 90E0773D 112.8 1.8 6 E0774D 108.3 35 mm EN/IEC 60715 ø4 . 2 4.54.5 70 80 E0117D (M4) A 30 and A 40 3-pole Contactors Dimensions (in mm) A 30, A 40 + VE 5-1 electrical and mechanical interlock unit A 30, A 40 + VM 5-1 mechanical interlock unit A 30, A 40 + TA 25 DU thermal O/L relay * For TA 25 DU 32 only A 30, A 40 + TA 42 DU thermal O/L relay Page extracted from eCatalogue: Contactors - Sales Engineer Version - Page 20 of 25
6.56 75 mm EN/IEC 60715 35 mm x15 EN/IEC 60715 108 E1516D 110 E1504D 133.9 6.56 75 mm EN/IEC 60715 35 mm x 15 EN/IEC 60715 108 E1505D 7012 110 E1501D 6.56 75 mm EN/IEC 60715 35 m m x15 EN/IEC 60715 108 E1503D 110 E1506D 6.56 75 mm EN/IEC 60715 35 mm x 15 EN/IEC 60715 140.3 108 E1507D 41.5 110 E1542D 6.56 75 mm EN/IEC 60715 35 mm x15 EN/IEC 60715 108 E1543D 110 E1510D 6.56 75 mm EN/IEC 60715 35 mm x 15 EN/IEC 60715 160.4 108 E1511D 110 E1544D 6.56 75 mm EN/IEC 60715 35 mm x15 EN/IEC 60715 178.5 E1545D E0148D ø 6.2 (M6) 100 A 50, A 63 and A 75 3-pole Contactors AF 50, AF 63 and AF 75 3-pole Contactors Dimensions (in mm) A 50, A 63, A 75, AF 50, AF 63, AF 75 A 50, A 63, A 75, AF 50, AF 63, AF 75 + CA 5 front-mounted 1-pole auxiliary contact block A 50, A 63, A 75, AF 50, AF 63, AF 75 A 50, A 63, A 75, AF 50, AF 63, AF 75 + CAL 5 side-mounted 2-pole auxiliary contact block + CA 5 front-mounted 4-pole auxiliary contact block and corresponding 2-stack versions A 50, A 63, A 75, AF 50, AF 63, AF 75 A 50, A 63, A 75, AF 50, AF 63, AF 75 + RA 5 interface relay + TP pneumatic timer A 50, A 63, A 75, AF 50, AF 63, AF 75 drilling plan A 50, A 63, A 75, AF 50, AF 63, AF 75 + WB 75-A on-position latch Page extracted from eCatalogue: Contactors - Sales Engineer Version - Page 21 of 25
(M6) E0155D ø 6.2 E0148D ø 6.2 (M6) 100 155 110 E1508D 6.56 75 mm EN/IEC 60715 35 mm x 15 EN/IEC 60715 108 E1509D 110 175.5 E1521D 6.56 75 mm EN/IEC 60715 35 mm x15 EN/IEC 60715 108 114 E1535D A 50, A 63 and A 75 3-pole Contactors AF 50, AF 63 and AF 75 3-pole Contactors Dimensions (in mm) A 50, A 63, A 75, AF 50, AF 63, AF 75 + VE 5-2 electrical and mechanical interlock unit A 50, A 63, A 75, AF 50, AF 63, AF 75 + TA 75 DU thermal O/L relay Page extracted from eCatalogue: Contactors - Sales Engineer Version - Page 22 of 25
123.5 E0784D 75 mm EN/IEC 60715 6.5 148 E0785D 123.5 E0786D 150 6.5 75 mm EN/IEC 60715 12 90 148 E0787D 123.5 E0788D 75 mm EN/IEC 60715 6.5 148 E0789D 123.5 E0790D 156,5 6.5 75 mm EN/IEC 60715 126 E0215D1 ø 6.2 (M6) 136 A 95 and A 110 3-pole Contactors AF 95 and AF 110 3-pole Contactors Dimensions (in mm) A 95, A 110, AF 95, AF 110 A 95, A 110, AF 95, AF 110 + CA 5 front-mounted 1-pole auxiliary contact block A 95, A 110, AF 95, AF 110 A 95, A 110, AF 95, AF 110 + CAL 18 side-mounted 2-pole auxiliary contact block + CA 5 front-mounted 4-pole auxiliary contact block and corresponding 2-stack versions A 95, A 110, AF 95, AF 110 drilling plan Page extracted from eCatalogue: Contactors - Sales Engineer Version - Page 23 of 25
123.5 E0794D 75 mm EN/IEC 60715 6.5 136 E0795D 126 183 ø 6.2 (M6) ø 6.2 (M6) 214 148 E0826D 123.5 114 E0827D 75 mm EN/IEC 60715 6.5 258 148 E0828D 131 123.5 E0829D 75 mm EN/IEC 60715 6.5 126 E0215D1 ø 6.2 (M6) 136 15ø 6.5 189 E0838D 174 E2049D 75 mm EN/IEC 60715 6.5 123.5 80.2 3 A 95 and A 110 3-pole Contactors AF 95 and AF 110 3-pole Contactors Dimensions (in mm) A 95, A 110, AF 95, AF 110 + LW 110 terminal enlargement A 95, A 110, AF 95, AF 110 + VE 5-2 electrical and mechanical interlock unit A 95, A 110, AF 95, AF 110 A 95, A 110, AF 95, AF 110 + TA 80 DU thermal O/L relay + TA 110 DU thermal O/L relay Page extracted from eCatalogue: Contactors - Sales Engineer Version - Page 24 of 25
10, Rue Ampère
69685 Chassieu
+33 (0)4 72 22 26 41 inside.abb.com/global/gad/gad00418.nsf/0/d298c2df4c35ddd8c1256efc004e4ad6?OpenDocument As part of its on-going product improvement, ABB reserves the right to modify the characteristics or the products described in this document. The information given is not-contractual. For further details please contact the ABB company marketing these products in your country. ABB