A2SAF0105 ASHCROFT | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 4
Technical content
All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft® and Trust the Shield® are trademarks of Ashcroft Inc. The following non-Ashcroft trademarks are the property of their respective owners: 17-4PH®, Aminco®, Bendix® , Hirschmann®, VCR®, Tri-Clamp®. For more information, see Ashcroft Brands & Trademarks of 4 A2 Pressure Transmitter
FEATURES
Highly configurable: wide selection of pressure ranges, pressure connections and electrical terminations Output: select voltage or current versions Available with externally adjustable zero and span access TYPICAL USES Test stands Compressor control Hydraulic systems Process automation Pump and pneumatic systems control KEY BENEFITS
- Provides the user with accurate, reliable, and stable output data
- Board microprocessor provides extremely linear and precise performance over the entire pressure and temperature range PERFORMANCE SPECIFICATIONS Reference Temperature: 70 °F (21 °C) Accuracy Class (Includes non-linearity): Terminal Point Method includes: hysteresis, non-repeatability, zero offset and span setting errors Best Fit Straight Line (BFSL): Add ±0.05% for ranges >5,000 psi Durability: >10 million cycles Stability: ≤±0.25% span/year at reference conditions ENVIRONMENTAL SPECIFICATIONS Temperature Effects: -4 °F to 185 °F (-20 °C to 85 °C) ±1.0% of span for ±0.25% accuracy class ±2.0% of span for ±0.5% and ±1.0% accuracy class Temperature Limits: Storage: Operating: Compensated: -40 °F to 257 °F (-40 °C to 125 °C) -40 °F to 257 °F (-40 °C to 125 °C) -4 °F to 185 °F (-20 °C to 85 °C) Humidity Effects: 0-95% R.H. non-condensing (no effects) 0-100% R.H. with welded enclosure (no effects) FUNCTIONAL SPECIFICATIONS Response Time: <2ms Pressure Ranges: Vacuum, gauge, compound and absolute pressure from 0 to 5 psi through 0 to 10,000 psi (Bar ranges available) Shock: 100g Peak, 11ms Random Vibration: 10g RMS, 20-2,000Hz Sweep Vibration: 50-2,000Hz, 5g peak Position Effect: ±0.02%, typical Overpressure: ≤300 psi ≥500 to ≤10,000 psi Proof:
1.5 X Range
1.2 X Range
Burst:
2 X Range
Circuit Protection: Reverse polarity and mis-wire protected Insulation Resistance (Circuit Case):
100 MΩ @ 30 Vdc
Output Signal: 0-5 Vdc (3 Wire) 0-10 Vdc (3 Wire) 1-5 Vdc (3 Wire) 1-6 Vdc (3 Wire) 4-20 mA (2 Wire) Supply Voltage: (unregulated) Min. Max.
12 Vdc 36 Vdc
14 Vdc 36 Vdc
10 Vdc 36 Vdc
All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft® and Trust the Shield® are trademarks of Ashcroft Inc. The following non-Ashcroft trademarks are the property of their respective owners: 17-4PH®, Aminco®, Bendix® , Hirschmann®, VCR®, Tri-Clamp®. For more information, see Ashcroft Brands & Trademarks of 4 A2 Pressure Transmitter LOAD LIMITATIONS 4-20 mA OUTPUT ONLY WETTED MATERIAL Diaphragm Process Connection 316L Stainless steel or 17-4PH® 316L Stainless Steel NON-WETTED Housing
304 Stainless steel
VdcMin = 12V + (0.022A* X (RL)) RL = RS+ RW RL = Loop Resistance (ohms) RS = Sense Resistance (ohms) RW = Wiring Resistance (ohms) * (Includes a 10% safety factor) RL-Loop Resistance (/uni03A9) Electrical Terminations: See ordering code on page 3 for options PHYSICAL SPECIFICATIONS Environmental Rating: IP65, NEMA 4X
All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft® and Trust the Shield® are trademarks of Ashcroft Inc. The following non-Ashcroft trademarks are the property of their respective owners: 17-4PH®, Aminco®, Bendix® , Hirschmann®, VCR®, Tri-Clamp®. For more information, see Ashcroft Brands & Trademarks of 4 A2 Pressure Transmitter ORDERING CODE Example: A2 S A M01 05 F2 50# G –X6B Model A2 - Industrial pressure transmitter A2 Enclosure S - Basic S Z - Zero and span access Y - Welded with zero & span access W - Welded w/out zero & span access Accuracy/Temp. Effects Pressure Connection F01 - 1⁄8 NPT Female F02 - 1/4 NPT Female F04 - 1/2 NPT Female F09 - 9⁄16-18 (1/4)-Female (Aminco ®) FRW - 7⁄16-20 SAE-Female MEK - 7⁄16-20 SAE-Male MG2 - G1/4 Male MG4 - G1/2 Male M01 - 1⁄8 NPT Male M01 M02 - 1/4 NPT Male M04 - 1/2 NPT Male VM2 - VCR® process connection 1/4˝ VCR ® gland w/ 9⁄16-18 Male nut VF2 - VCR® process connection 1/4˝ VCR ® gland w/ 9⁄16-18 Female nut S15 - Sanitary seal 11/2˝ Tri-Clamp ® S20 - Sanitary seal 2˝ Tri-Clamp ® Output Signal 05 - 0-5 Vdc 05 10 - 0-10 Vdc 15 - 1-5 Vdc 16 - 1-6 Vdc 42 - 4-20 mA Electrical Termination Integral Cable (Pigtail) F2 - 3´ shielded cable ( available with enclosure code or S, Z) F2 P1 - Specify length ( available with enclosure code or S, Z) Hirschmann ® Style Form A DIN 43650-A DN - W/o mating conn. ( available with enclosure code or S, Z) D0 - With mating conn., no cable (available with enclosure code or S, Z) D2 - With mating conn., 3´ cable ( available with enclosure code or S, Z) D1 - With mating conn., specify length (available with enclosure code or S, Z) 4-Pin Bendix ® Style B4 - W/o mating conn. (available with enclosure code or S, Z, W, Y) H1 - With mating conn., no cable (available with enclosure code or S, Z, W, Y) L1 - With mating conn., 3´ cable (available with enclosure code or S, Z, W, Y) P2 - With mating conn., specify length (available with enclosure code or S, Z, W, Y) 1/2 NPT-M Conduit Shielded Cable (NEMA Rating not valid for ranges ≤300 psi) C1 - 3´ Shielded cable (available with enclosure code W, Y) C6 - 15´ Shielded cable ( available with enclosure code W, Y) C7 - 30´ Shielded cable ( available with enclosure code W, Y) P7 - Shielded cable specify length ( available with enclosure code W, Y) 1/2 NPT-M Conduit Flying Leads (NEMA Rating not valid for ranges ≤300 psi) C2 - 3´ Flying leads ( available with enclosure code W, Y) C5 - 10´ Flying leads ( available with enclosure code W, Y) M12 Threaded EW - W/o mating conn. ( available with enclosure code or S, Z) E0 - With mating conn. no cable ( available with enclosure code or S, Z) E2 - With mating conn. 3´ cable ( available with enclosure code or S, Z) E1 - With mating conn., specify length ( available with enclosure code or S, Z) Pressure Range (see range table on page 4) 50# - 50 psi 50# Measurement Type G - Gauge pressure G Option (if including an option(s) must include an “X’’) X _ _ CL - Non-standard calibration K8 - 17-4PH® Stainless steel sensor material 6B - Cleaned for oxygen service (Not available with absolute ranges) 6B
All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft® and Trust the Shield® are trademarks of Ashcroft Inc. The following non-Ashcroft trademarks are the property of their respective owners: 17-4PH®, Aminco®, Bendix® , Hirschmann®, VCR®, Tri-Clamp®. For more information, see Ashcroft Brands & Trademarks of 4 A2 Pressure Transmitter 3.065 4.45 2.20 0.88 4.78 3.065 0.675 1.06 DIA. [22.5] [121] [78] [17] [27] 0.50 [56] 0.885 1.06 [27] Hex. Common For All Pressure Fittings [22] [78] [113] [13] 1.06 DIA. [27] Heavy Industrial (Enclosure S, Z, Y, W) RANGE TABLE Vacuum Range Code Notes 0 psi/-14.7 psi 0#&vac 17-4PH® SS sensor not available, gauge pressure only Compound 15 psi/-14.7 psi 15#&vac 17-4PH® SS sensor not available, gauge pressure only 30 psi/-14.7 psi 30#&vac 17-4PH® SS sensor not available, gauge pressure only 45 psi/-14.7 psi 45#&vac Gauge pressure only 60 psi/-14.7 psi 60#&vac Gauge pressure only 1.5 psi 1.5# 17-4PH® SS sensor not available, gauge pressure only, available with accuracies B or C only 5 psi 5# 17-4PH® SS sensor not available, gauge pressure only 10 psi 10# 17-4PH® SS sensor not available, gauge pressure only 15 psi 15# 17-4PH® SS sensor not available Positive Pressure 30 psi 30# 17-4PH® SS sensor not available 50 psi 50# 60 psi 60# 75 psi 75# 100 psi 100# 150 psi 150# 200 psi 200# 300 psi 300# 500 psi 500# 750 psi 750# 1,000 psi 1000# 1,500 psi 1500# 2,000 psi 2000# 3,000 psi 3000# 5,000 psi 5000# 6,000 psi 6000# 7,500 psi 7500# 10,000 psi 10000# 17-4PH® SS sensor required DIMENSIONS in [ ] are millimeters For reference only, consult Ashcroft for specific dimensional drawings