AC axial fanA2S130-AB03-11 ebm-papst Mulfingen GmbH & Co. KG Bachmühle 2 · D-74673 Mulfingen Phone +49 7938 81-0 Fax +49 7938 81-110 info1@de.ebmpapst.com www.ebmpapst.com Limited partnership · Headquarters Mulfingen County court Stuttgart · HRA 590344 General partner Elektrobau Mulfingen GmbH · Headquarters Mulfingen County court Stuttgart · HRB 590142 Nominal data Type A2S130-AB03-11 Motor M2S052-CA Phase 1~ 1~ Nominal voltage VAC 230 230 Nominal voltage range VAC 220 .. 240 Frequency Hz 50 60 Type of data definition fa fa Valid for approval / standard CE UL Speed min-1 2800 3250 Power input W 50 44 Current draw A 0.3 - Min. ambient temperature °C -25 -25 Max. ambient temperature °C - 60 Starting current A 0.40 ml = Max. load · me = Max. efficiency · fa = Running at free air · cs = Customer specs · cu = Customer unit Subject to alterations Item no. 10617-5-9980 · Revision 82552 · Release 2014-05-08 · Page 1 / 5
AC axial fanA2S130-AB03-11 Technical features Mass 0.9 kg Size 130 mm Surface of rotor Coated in black Material of blades Sheet steel, coated in black Number of blades 7 Direction of air flow "V" Direction of rotation Counter-clockwise, seen on rotor Type of protection IP 44 Insulation class "B" Max. permissible ambient motor temp. (transp./ storage) + 80 °C Min. permissible ambient motor temp. (transp./storage) - 40 °C Mounting position Any Condensate discharge holes None Operation mode S1 Motor bearing Ball bearing Touch current acc. IEC 60990 (measuring network Fig. 4, TN system) < 0.75 mA Motor protection Thermal overload protector (TOP) wired internally Cable exit Variable Protection class I (if earth wire is connected by customer) Product conforming to standard EN 60335-1; CE Approval CCC; CSA C22.2 Nr.100; EAC; UL 1004-1 Item no. 10617-5-9980 · Revision 82552 · Release 2014-05-08 · Page 2 / 5
AC axial fanA2S130-AB03-11 Product drawing
1 Direction of air flow "V"
2 Connection line AWG 20, 2x crimped core-end sleeves
3 Depth of screw max. 5 mm Connection screen L = black N = black TOP = Thermal overload protector Item no. 10617-5-9980 · Revision 82552 · Release 2014-05-08 · Page 3 / 5
AC axial fanA2S130-AB03-11 Charts: Air flow 50 Hz pfs @ rho=1,2 kg/m³ qv [m³/h]300250200150100500 qv [CFM] 2001801601401201008060402000pfs [Pa] 1601501401301201101009080706050403020100 pfs [InH2O] Measurement: LU-11003 Air performance measured as per ISO 5801 Installation category A. For detailed information on the measuring set-up, please contact ebm-papst. Suction-side noise levels: LwA measured as per ISO 13347 / LpA measured with 1m distance to fan axis. The values given are valid under the measuring conditions mentioned above and may vary according to the actual installation situation. With any deviation from the standard set-up, the specific values have to be checked and reviewed with the unit installed. Measured values U V 240 240 240 240 f Hz n min-1 2800 2790 2775 2760 Pe W I A 0.30 0.30 0.30 0.30 qv m3/h 325 300 265 210 pfs Pa U = Supply voltage · f = Frequency · n = Speed · Pe = Power input · I = Current draw · qv = Air flow · pfs = Pressure increase Item no. 10617-5-9980 · Revision 82552 · Release 2014-05-08 · Page 4 / 5
AC axial fanA2S130-AB03-11 Charts: Air flow 60 Hz Druck p f s[Pa]für Rho=1,2kg/m^3 qv[m^3/h]420400380360340320300280260240220200180160140120100806040200 qv[cfm] 250200150100500p f s[Pa] 18017517016516015515014514013513012512011511010510095908580757065605550454035302520151050 pfs_E[IN H2O] Air performance measured as per ISO 5801 Installation category A. For detailed information on the measuring set-up, please contact ebm-papst. Suction-side noise levels: LwA measured as per ISO 13347 / LpA measured with 1m distance to fan axis. The values given are valid under the measuring conditions mentioned above and may vary according to the actual installation situation. With any deviation from the standard set-up, the specific values have to be checked and reviewed with the unit installed. Measured values U V 230 230 230 230 f Hz n min-1 3250 3200 3165 3170 Pe W I A 0.25 0.25 0.26 0.26 qv m3/h 390 355 305 200 pfs Pa U = Supply voltage · f = Frequency · n = Speed · Pe = Power input · I = Current draw · qv = Air flow · pfs = Pressure increase Item no. 10617-5-9980 · Revision 82552 · Release 2014-05-08 · Page 5 / 5