Technical content
sickle-shaped blades (S series), single-intake A2D240-AA02-02 ebm-papst Mulfingen GmbH & Co. KG Bachmühle 2 · D-74673 Mulfingen Phone +49 7938 81-0 Fax +49 7938 81-110 info1@de.ebmpapst.com www.ebmpapst.com Limited partnership · Headquarters Mulfingen Amtsgericht (court of registration) Stuttgart · HRA 590344 General partner Elektrobau Mulfingen GmbH · Headquarters Mulfingen Amtsgericht (court of registration) Stuttgart · HRB 590142 Nominal data Type A2D240-AA02-02 Motor M2D068-CF Phase 3~ 3~ 3~ 3~ Nominal voltage VAC 230 230 400 400 Wiring Δ Δ Y Y Frequency Hz 50 60 50 60 Method of obtaining data fa fa fa fa Valid for approval/standard CE CE CE CE Speed (rpm) min-1 2550 2700 2550 2700 Power consumption W 95 125 95 125 Current draw A 0.31 0.35 0.18 0.20 Min. ambient temperature °C -25 -25 -25 -25 Max. ambient temperature °C 75 70 75 70 Starting current A 0.88 0.87 0.51 0.5 ml = Max. load · me = Max. efficiency · fa = Free air · cs = Customer specification · ce = Customer equipment Subject to change Item no. 14661-5-9980 · ENU · Change 89188 · Approved 2016-04-28 · Page 1 / 6
sickle-shaped blades (S series), single-intake A2D240-AA02-02 Technical description Weight 1.65 kg Fan size 240 mm Rotor surface Painted black Blade material Sheet steel, painted black Number of blades 5 Airflow direction "A" Direction of rotation Clockwise, viewed toward rotor Degree of protection IP44; installation- and position-dependent Insulation class "B" Moisture (F) / Environmental (H) protection class Max. permitted ambient temp. for motor (transport/storage) + 80 °C Min. permitted ambient temp. for motor (transport/storage) - 40 °C Installation position Any Condensation drainage holes None Mode S1 Motor bearing Ball bearing Touch current according to IEC 60990 (measuring circuit Fig. 4, TN system) < 0.75 mA With cable Lateral Protection class I (with customer connection of protective earth) Conformity with standards EN 60335-1, motor does not have factory-installed overheating protection; CE Item no. 14661-5-9980 · ENU · Change 89188 · Approved 2016-04-28 · Page 2 / 6
sickle-shaped blades (S series), single-intake A2D240-AA02-02 Product drawing
1 Direction of air flow "A"
2 Max. clearance for screw 5 mm 3 Cable PVC 7G 0.5 mm², 7x crimped splices Item no. 14661-5-9980 · ENU · Change 89188 · Approved 2016-04-28 · Page 3 / 6
sickle-shaped blades (S series), single-intake A2D240-AA02-02 Connection diagram Change of rotation direction by reversing two phases Three-phase motor Δ Delta connection Y Star connection L1 = U1 = black L2 = V1 = blue L3 = W1 = brown U2 green V2 white W2 yellow PE green/yellow Item no. 14661-5-9980 · ENU · Change 89188 · Approved 2016-04-28 · Page 4 / 6
sickle-shaped blades (S series), single-intake A2D240-AA02-02 Curves: Air performance 50 Hz pfs @ rho=1,2 kg/m³ qv [m³/h] 1200 1000 800 600 400 200 0 qv [CFM] 750 700 650 600 550 500 450 400 350 300 250 200 150 100 50 00 pfs [Pa] 300280260240220200180160140120100806040200 pfs [InH2O] Measurement: LU-59198-1 Air performance measured according to ISO 5801 installation category A. For detailed information on the measurement setup, contact ebm-papst. Intake sound level: Sound power level according to ISO 13347 / sound pressure level measured at 1 m distance from fan axis. The values given are valid under the specified measuring conditions and may vary due to conditions of installation. For deviations from the standard configuration, the parameters have to be checked on the installed unit. Measured values U V 400 400 400 400 f Hz n min-1 2550 2515 2500 2490 Pe W 100 101 I A 0.18 0.18 0.18 0.18 qv m3/h 1220 1130 1010 870 pfs Pa 110 qv CFM 715 665 595 510 pfs inH2O 0.00 0.16 0.32 0.44 U = Power supply · f = Frequency · n = Speed (rpm) · Pe = Power consumption · I = Current draw · qv = Air flow · pfs = Pressure increase Item no. 14661-5-9980 · ENU · Change 89188 · Approved 2016-04-28 · Page 5 / 6
sickle-shaped blades (S series), single-intake A2D240-AA02-02 Curves: Air performance 60 Hz pfs @ rho=1,2 kg/m³ qv [m³/h] 1400 1200 1000 800 600 400 200 0 qv [CFM] 800 750 700 650 600 550 500 450 400 350 300 250 200 150 100 50 00 pfs [Pa] 300280260240220200180160140120100806040200 pfs [InH2O] Measurement: LU-59199-1 Air performance measured according to ISO 5801 installation category A. For detailed information on the measurement setup, contact ebm-papst. Intake sound level: Sound power level according to ISO 13347 / sound pressure level measured at 1 m distance from fan axis. The values given are valid under the specified measuring conditions and may vary due to conditions of installation. For deviations from the standard configuration, the parameters have to be checked on the installed unit. Measured values U V 400 400 400 400 f Hz n min-1 2700 2675 2640 2620 Pe W 125 129 133 135 I A 0.20 0.21 0.21 0.21 qv m3/h 1305 1210 1090 935 pfs Pa 120 qv CFM 770 710 645 550 pfs inH2O 0.00 0.16 0.32 0.48 U = Power supply · f = Frequency · n = Speed (rpm) · Pe = Power consumption · I = Current draw · qv = Air flow · pfs = Pressure increase Item no. 14661-5-9980 · ENU · Change 89188 · Approved 2016-04-28 · Page 6 / 6