Features

SmartScan™ is a trademark of Gamewell. 6724mod2.tif

SCE-SS and RCE-SS CS-2466 09/01/06Page 2 of 4 Specifications for SCE-SS Normal operating voltage: 15 to 32 VDC. Maximum current draw: 6.5 mA (LED on). Average operating current: 375 µA group poll (Smart Scan™ mode) with LED flashing. External supply voltage (between Terminals T3 and T4): maximum 80 volts (RMS or DC). Drain on external supply: 2 mA maxi- mum (using internal EOL relay). EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% non- condensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. Specifications for RCE-SS Normal operating voltage: 15 to 32 VDC. Maximum current draw: 6.5 mA (LED on). Average operating current: 255 µA group poll (Smart Scan™ mode) with LED flashing. EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% non- condensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. Normal operating voltage: 15 to 32 VDC. Maximum current draw: 6.5 mA (LED on). Average operating current: 255 µA group poll (Smart Scan™ mode) with LED flashing. EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% non- condensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. Product Line Information SCE-SS Intelligent Addressable Control Module. RCE-SS Intelligent Addressable Relay Module. A2143-20 Capacitor, required for Class A (Style Z) operation of speakers. SMB500 Optional Surface-Mount Backbox. CB500 Control Module Barrier — required by UL for separating power-limited and non-power-limited wiring in the same junction box as SCE-SS-1. Relay Contact Ratings for both SCE-SS and RCE-SS models Mounting Diagrams Note CB500 Module Barrier, which creates isolated quadrant. Load D escription Application Maximum Voltage Current Rating R esistive N on-coded 30 VD C 3.0 A R esistive C oded 30 VD C 2.0 A Resistive Non-coded 110 VDC 0.9 A Resistive Non-coded 125 VAC 0.9 A Inductive (L/R = 5 ms) Coded 30 VDC 0.5 A Inductive (L/R = 2 ms) Coded 30 VDC 1.0 A Inductive (P F = 0.35) Non-coded 125 VAC 0.5 A 6724mt2.wmf 6724mt1.wmf

SCE-SS and RCE-SS CS-2466 09/01/06 Page 3 of 4 Wiring Diagrams The following wiring diagrams are provided: 1) SCE-SS: Typical notification appliance circuit configuration, NFPA Style Y . 2) SCE-SS: Typical fault-tolerant notification appliance circuit configuration, NFPA Style Z. 3) SCE-SS: Typical wiring for speaker supervision and switching, NFPA Style Y . 4) SCE-SS: Typical fault-tolerant wiring for speaker supervision and switching, NFPA Style Z. 5) RCE-SS: Relay module wiring diagram. Fig. 1 SCE-SS: Typical notification appliance circuit configuration, NFPA Style Y. Fig. 2 SCE-SS: Typical fault-tolerant notification appliance circuit configuration, NFPA Style Z.  Connect modules to Listed compatible Gamewell control panels only.  All wiring shown is supervised and power limited.  Module polarities are shown in alarm.  Connect modules to Listed compatible Gamewell control panels only.  All wiring shown is supervised and power limited.  Module polarities are shown in alarm. 6827wir1.wmf 6827wir2.wmf

SCE-SS and RCE-SS CS-2466 09/01/06Page 4 of 4 Gamewell-FCI

12 Clintonville Road

Northford, CT 06472-1610 Phone: 203-484-7161 Fax: 203-484-7118 www.gamewell-fci.com A Honeywell Company © 2006 Gamewell-FCI Specifications and wiring information are provided for information only and are believed to be accurate. Gamewell-FCI assumes no responsibility for their use. Data and design are subject to change without notice. Installation and wiring instructions shipped with the product shall always be used for actual installation. For more information, contact Gamewell-FCI. Fig. 3 SCE-SS: Typical wiring for speaker supervision and switching, NFPA Style Y.  Connect modules to Listed compatible Gamewell control panels only.  All wiring shown is supervised.  Wires must be supervised per NFPA.  Module polarities are shown in alarm. Fig. 4 SCE-SS: Typical fault-tolerant wiring for speaker supervision and switching, NFPA Style Z.  Connect modules to Listed compatible Gamewell control panels only.  All wiring shown is supervised.  Wires must be supervised per NFPA.  Module polarities are shown in alarm. 6724wir3.wmf 6724wir4.wmf NOTE regarding AUDIO AMPLIFIER in Figures 3 & 4: 1) Audio circuit wiring must be twisted-pair as a minimum. See Gamewell installation manual for detailed information. Fig. 5 RCE-SS: Relay module wiring diagram.  Connect modules to Listed compatible Gamewell control panels only.  Module does NOT supervise controlled circuits. 6724wir5.wmf