"No longer for sale" replaced by A16-30-10 220-230V 50Hz / 230-240V 60Hz Contactor A16-30-10 220-230V 50Hz / 230-240V 60Hz Extended Product Type A16-30-10 220-230V 50Hz / 230-240V 60Hz Product ID 1SBL181001R8010 EAN 3471522050809 Catalog Description A16-30-10 220-230V 50Hz / 230-240V 60Hz Contactor Long Description A16 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC or 220 V DC. The contactors can also be used for many other applications such as isolation, capacitor switching, lighting. The A... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front and side-mounted add-on auxiliary contact blocks - Control circuit: AC operated with laminated magnet circuit - Accessories: a wide range of accessories is available. General Information PRODUCT-DETAILS Ordering 1 piece Minimum Order Quantity 85364900 Customs Tariff Number 1SBL171001R8010 Replacement Product ID (NEW) Popular Downloads 1SBC100122C0202_Ch02 Data Sheet, Technical Information FPTC407721P0001 Instructions and Manuals
0.34 kg Product Net Weight Technical Number of Main Contacts NO Number of Main Contacts NC Number of Auxiliary Contacts NO Number of Auxiliary Contacts NC Devices complying with international standards IEC 947-1 / 947-4-1, and European standards EN 60 947-1 / 60 947-4-1. Electromagnetic compatibility (EMC) acc. to amendment A11 to IEC 947-1, EN 60 947-1 and amendment 2 to IEC 947-4-1 Standards Auxiliary Circuit 690 V Main Circuit 690 V Rated Operational Voltage Auxiliary Circuit 50 / 60 Hz Control Circuit 50 / 60 Hz Rated Frequency (f) acc. to IEC 60947-4-1, Open Contactors q = 40 °C 30 A acc. to IEC 60947-5-1, q = 40 °C 16 A Conventional Free-air Thermal Current (I th (690 V) 40 °C 30 A (690 V) 55 °C 27 A (690 V) 70 °C 23 A Rated Operational Current AC-1 (I e (415 V) 55 °C 17 A (440 V) 55 °C 16 A (500 V) 55 °C 14 A (690 V) 55 °C 10 A (380 / 400 V) 55 °C 17 A (220 / 230 / 240 V) 55 °C 17 Rated Operational Current AC-3 (I e (415 V) 9 kW (440 V) 9 kW (500 V) 9 kW (690 V) 9 kW (380 / 400 V) 7.5 kW (220 / 230 / 240 V) 4 kW Rated Operational Power AC-3 (P e (230 / 240 V) 40 °C, 50 / 60 Hz 7.5 kvar (230 / 240 V) 55 °C, 50 / 60 Hz 7.5 kvar (230 / 240 V) 70 °C, 50 / 60 Hz 6 kvar (400 / 415 V) 40 °C, 50 / 60 Hz 12.5 kvar (400 / 415 V) 70 °C, 50 / 60 Hz 10 kvar (400 / 415 V) 55 °C, 50 / 60 Hz 12.5 kvar (440 V) 40 °C, 50 / 60 Hz 14 kvar (440 V) 55 °C, 50 / 60 Hz 14 kvar (440 V) 70 °C, 50 / 60 Hz 10.5 kvar (500 / 550 V), 40 °C, 50 / 60 Hz 15.5 kvar (500 / 550 V) 55 °C, 50 / 60 Hz 15.5 kvar (500 / 550 V) 70 °C, 50 / 60 Hz 12 kvar (690 V) 40 °C, 50 / 60 Hz 21.5 kvar (690 V) 55 °C, 50 / 60 Hz 21.5 kvar (690 V) 70 °C, 50 / 60 Hz 16.5 kvar Rated Operational Power AC-6b (P e 8 x Ie AC-3 Rated Breaking Capacity AC-3 10 x Ie AC-3 Rated Making Capacity AC-3 (500 V) 2 A (690 V) 2 A (24 / 127 V) 6 A (220 / 240 V) 4 A (380 / 400 V) 3 A Rated Operational Current AC-15 (I e Auxiliary Circuit - gG Type Fuses 10 A gG Type Fuses 32 A Short-Circuit Protective Devices A16-30-10 220-230V 50Hz / 230-240V 60Hz
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 140 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 30 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 A Rated Short-time Withstand Current Low Voltage (I cw cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A Maximum Breaking Capacity (AC-1) 600 cycles per hour (AC-2 / AC-4) 300 cycles per hour (AC-3) 1200 cycles per hour Maximum Electrical Switching Frequency (24 V) 6 / 144 A (48 V) 2.8 / 134 A (72 V) 2 / 144 A (125 V) 1.1 / 138 A (250 V) 0.55 / 138 A Rated Operational Current DC-13 (I e acc. to IEC 60947-4-1 1000 V acc. to IEC 60947-5-1 690 V acc. to UL/CSA 600 V Rated Insulation Voltage i 8 kV Rated Impulse Withstand Voltage (U imp 3600 cycles per hour Maximum Mechanical Switching Frequency 50 Hz 220 ... 230 V 60 Hz 230 ... 240 V Rated Control Circuit Voltage (U c Average Holding Value 50 / 60 Hz 8 V·A Average Pull-in Value 50 Hz 74 V·A Average Pull-in Value 60 Hz 70 V·A Coil Consumption Between Coil De-energization and NO Contact Opening 4 ... 11 ms Between Coil Energization and NO Contact Closing 10 ... 26 ms Operate Time TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 Mounting on DIN Rail 2 x M4 screws placed diagonally Mounting by Screws (not supplied) Rigid Cable 1 ... 4 mm² Connecting Capacity Main Circuit Rigid Cable 1 ... 4 mm² Connecting Capacity Auxiliary Circuit acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20 Degree of Protection M 3.5 (+,-) pozidriv 2 screws with cable clamp Connecting Terminals (delivered in open position) Main Poles Screw Terminals Terminal Type Technical UL/CSA (600 V AC) 30 A General Use Rating UL/CSA (200 ... 208 V AC) Three Phase 5 hp (220 ... 240 V AC) Three Phase 5 hp (440 ... 480 V AC) Three Phase 10 hp (550 ... 600 V AC) Three Phase 15 hp Horsepower Rating UL/CSA Environmental Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C Close to Contactor without Thermal O/L Relay (Uc) -40 ... 70 °C Close to Contactor for Storage -60 ... +80 °C Ambient Air Temperature acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II Climatic Withstand Without Derating 3000 m Maximum Operating Altitude Permissible Closed, Shock Direction: B1 10 g Open, Shock Direction: B1 5 g Shock Direction: A 20 g Resistance to Shock acc. to IEC 60068-2-27 A16-30-10 220-230V 50Hz / 230-240V 60Hz
Shock Direction: B2 15 g Shock Direction: C1 20 g Shock Direction: C2 20 g Following EU Directive 2011/65/EU RoHS Status Certificates and Declarations (Document Number) BV_2634H07559E0 BV Certificate CB_CN44759 CB Certificate CCC_2018010304059156 CCC_2004010309130463 CCC Certificate CQC2013010304615753 CQC2018010304059156 CQC2004010309130463 CQC Certificate CSA_1041746 CSA Certificate 2020980304001607 2020980304001616 2020980304001229 Declaration of Conformity - CCC 1SBD250801U1000 Declaration of Conformity - CE 1SBD250818U1000 Declaration of Conformity - UKCA DNV-GL_TAE00000TX DNV Certificate DNV-GL_TAE00000TX DNV GL Certificate EAC_RU C-FR ME77 B03599 EAC Certificate 1SBD250003E1004 Environmental Information FPTC407721P0001 Instructions and Manuals LOVAG_FR97039 LOVAG Certificate LRS_9830011E4 LR Certificate RINA_ELE172319XG001 RINA Certificate RMRS_0507015250 RMRS Certificate 2CMT2021-006277 RoHS Information UL_20160205-E312527-10-2 UL Certificate UL_E312527 UL Listing Card Container Information 1 piece Package Level 1 Units 78 mm Package Level 1 Width 76 mm Package Level 1 Depth / Length 47 mm Package Level 1 Height 0.34 kg Package Level 1 Gross Weight 3471522050809 Package Level 1 EAN box 63 piece Package Level 2 Units 300 mm Package Level 2 Width 245 mm Package Level 2 Depth / Length 308 mm Package Level 2 Height 21.42 kg Package Level 2 Gross Weight 1220 piece Package Level 3 Units Classifications Q Object Classification Code A16-30-10 220-230V 50Hz / 230-240V 60Hz
EC000066 - Magnet contactor, AC-switching ETIM 4 EC000066 - Magnet contactor, AC-switching ETIM 5 EC000066 - Power contactor, AC switching ETIM 6 EC000066 - Power contactor, AC switching ETIM 7 EC000066 - Power contactor, AC switching ETIM 8 V11.0 : 27371003 eClass 39121529 UNSPSC 4756 >> Capacitor magnet contactor IDEA Granular Category Code (IGCC) 3709218 E-Number (Finland) Block Contactors Categories A16-30-10 220-230V 50Hz / 230-240V 60Hz