A1210EKPGHT-10-B CRYDOM | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 7
Technical content
- Ratings from 10A to 40A @ 24-140 VAC
- SCR output for heavy industrial loads
- Zero voltage or instantaneous turn-on outputs
- UL/CSA/VDE Approved, CE Compliant to EN60950-1
- Improved SEMS screw and washer
- Redesigned housing with anti-rotation barriers For Generation 3 datasheet click here
- AC or DC control
- Direct bond copper substrate
- Direct power lead frame
- Epoxy free design PRODUCT SELECTION 40A25A10AControl Voltage 3-32 VDC D1210T D1225T D1240T 90-280 VAC A1210T A1225T A1240T 18-36 VAC A1210ET A1225ET A1240ET AVAILABLE OPTIONS Control Voltage A: 90-280 VAC D: 3-32 VDC AxxxxE: 18-36 VAC Rated Load Current 10: 10 Amps 25: 25 Amps 40: 40 Amps Operating Voltage 12: 24-140 VAC Overvoltage Protection Blank: Not Included P: Included Input Status LED Blank: Not Included G: Included Termination Blank: Screw F: Quick Connect (Up to 50 Amps only) K: Hex standoffs
10 EA P G12 K
Blank: Not Included H: Included H Switching Type Blank: Zero Voltage Turn-On -10: Instantaneous Turn-On Trigger Circuit T: Phototransistor (Not needed with -B suffix, included as standard) -10T Output Type -B: Normally Closed (Not available with -10 option) (3) (1) (2) (4) OUTPUT SPECIFICATIONS (5) 40A25A10ADescription Operating Voltage Range (47-63Hz) [Vrms] 24-140 VAC 24-140 VAC 24-140 VAC Transient Overvoltage [Vpk] 600 600 600 Maximum Off-State Leakage Current @ Rated Voltage [mArms] 8 8 8 Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] 500 500 500 Maximum Load Current [Arms] (2)(6) 10 25 40 Minimum Load Current [mArms] 40 40 40 Maximum 1 Cycle Surge Current (50/60 Hz) [Apk] 115/120 239/250 597/625 Maximum I²t for Fusing (50/60Hz) [A² sec] 66/60 285/259 1770/1629 Maximum On-State Voltage Drop @ Rated Current [Vrms] (7) 1.15 1.15 1.15 Thermal Resistance Junction to Case (Rjc) [°C/W] 1.03 0.8 0.5 Minimum Power Factor (at Maximum Load) 0.5 0.5 0.5 INPUT SPECIFICATIONS (5) A12xxETA12xxTD12xxTDescription Control Voltage Range 3-32 VDC 90-280 Vrms 18-36 Vrms Minimum Turn-On Voltage (8) 3.0 VDC (9) 90 Vrms 18 Vrms Must Turn-Off Voltage (10) 1 VDC 10 Vrms 4 Vrms Minimum Input Current for on-state [mA] 3.4 2 2 Maximum Input Current for on-state [mA] 24 4.9 4 Nominal Input Impedance [Ohms] 1.5K 60K 9K Maximum Turn-on Time [msec] 1/2 Cycle (11) 10 10 Maximum Turn-off Time [msec] 1/2 Cycle 40 40 Required for valid part number For options only and not required for valid part number Not all part number combinations are available. Contact Crydom Technical support for information on the availability of a specific part number. DatasheetPanel Mount Do not forget to visit us at: www.crydom.com Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
GENERAL SPECIFICATIONS (5) ParametersDescription Dielectric Strength, Input/Output/Base (50/60Hz) 4000 Vrms Minimum Insulation Resistance (@ 500 VDC) 109 Ohm Maximum Capacitance, Input/Output 8 pF Ambient Operating Temperature Range -40 to 80 °C Ambient Storage Temperature Range -40 to 125 °C Weight (typical) 2.64 oz (74.9 gr) Housing Material UL 94 V-0 Baseplate Material Aluminum Input Terminal Screw Torque Range [in-lb/Nm] 13-15 / 1.5-1.7 Output Terminal Screw Torque Range [in lb/Nm] 18-20 (2-2.2) SSR Mounting Screw Torque Range [in-lb/Nm] 18-20 / 2.0-2.2 Humidity per IEC60068-2-78 93% Non condensing LED Input Status Indicator w/”G” option (green) MTBF (Mean Time Between Failures) at 40°C ambient temperature (12) 11,641,553 hours (1,328 years) MTBF (Mean Time Between Failures) at 60°C ambient temperature (12) 7,210,376 hours (823 years) WIRING DIAGRAM S OLI D S T A T E R ELA Y OUTPUT INPUT Load (13) V 4 (– / ) 3 (+ / ) 1 ( ) 2 ( ) AC Recommended Wire Sizes Terminals Wire Size (Solid / Stranded) Wire Pull-Out Strength (lb)[N] Input Output 24 AWG (0.2 mm 2) / 0.2 [minimum] 2 x 12 AWG (3.3 mm 2) / 3.3 [maximum] 20 AWG (0.5 mm 2) / 0.518 [minimum] 2 x 10 AWG (5.3 mm 2) / 5.3 2 x 8 AWG (8.4 mm 2) / 8.4 [maximum] 10 [44.5] 90 [400] 30 [133] 110 [490] 90 [400] Input Current vs Input Voltage “T” Option - Low Voltage Output Input Current (mA) 0 5 10 15 20 25 30 DC Input Voltage Diagram: A12xxT, A12xxET Diagram: D12xxT +DC -DC AC Trigger Circuit AC (14) (15)AC/DC Converter +DC -DC AC Trigger Circuit AC (14) (15) EQUIVALENT CIRCUIT BLOCK DIAGRAMS Input/Load Terminal Screw Torque Range (in-lb/Nm) (2) w/”K” option 8-10 / 0.9-1.13 DatasheetPanel Mount Do not forget to visit us at: www.crydom.com Copyright © 2016 Crydom Inc. Specifications subject to change without notice. Input/Output Terminal Screw Thread Size #6-32 UNC / #8-32 UNC
MECHANICAL SPECIFICATIONS(5) GENERAL NOTES Screw Termination
1 OUTPUT 2
4 INPUT 3
1.1 [27.9] 0.49 [12.4] Mounting Hole/Slot 0.19 [4.9] DIA. 0.89 [22.6] 1.88 [47.6] 1.7 [43.2] 2.25 [57.3] 1.0 [25.4] 1.75 [44.5] Hex Standoff Termination (“K” Option) 1.1 [27.9] 0.49 [12.4] Mounting Hole/Slot 0.19 [4.9] DIA. 1.04 [26.4] 1.88 [47.6] 1.70 [43.2] 2.25 [57.3] 1.0 [25.4] 1.75 [44.5] 0.93 [23.6] (4 places) 1.0 [25.4] (2 places) (2) Quick Connect Termination (“F” Option) - Up to 25 Amp (1) 0.19 [4.9] DIA. 1.58 [40.2] 0.49 [12.4] Faston Terminal(16) 0.25 x 0.032 (2 places) 1.31 [33.4] 1.88 [47.6] 1.7 [43.2] 2.25 [57.3] 1.40 [35.6] 1.75 [44.5] Faston Terminal(16) 0.187 x 0.020 (2 places) 1.25 [31.8] Quick Connect Termination (“F” Option) - Up to 50 Amp (1) S OLI D S T A T E R ELA Y OUTPUT INPUT Mounting Hole/Slot 0.19 [4.9] DIA. 1.58 [40.2] 0.49 [12.4] Faston Terminal(16) 0.25 x 0.032 (4 places) 1.31 [33.4] 1.88 [47.6] 1.7 [43.2] 2.25 [57.3] 1.40 [35.6] 1.75 [44.5] Faston Terminal(16) 0.187 x 0.020 (2 places) 1.25 [31.8] 0.63 [16.0] 0.45 [11.4] (2 places) Tolerances: ±0.02 in / 0.5 mm All dimensions are in: inches [millimeters] For additional information or specific questions, contact Crydom Technical Support. DatasheetPanel Mount Do not forget to visit us at: www.crydom.com Copyright © 2016 Crydom Inc. Specifications subject to change without notice. (1) Single pair (up to 25A) Double pair* (up to 50A). *Caution: User must connect both pairs. (2) Option “K” is designed and tested for use with printed circuit boards or ring/fork terminals having a thickness between 0.031 and 0.093 inches (0.79 to 2.36 mm), and loads rated up to 50 Amps. For higher load currents, the “K” standoff temperature must not exceed 105°C. For additional application assistance please contact Crydom Technical Support. (3) Output will self trigger between 450-600Vpk, Min., not suitable for capacitive loads. (4) Instantaneous turn-on version is not recomended for capacitive loads. Use zero turn-on only. (5) All parameters at 25°C unless otherwise specified. (6) Heat sinking required, see derating curves. (7) For 40mA minimum current, the voltage drop increases over maximum rated. (8) Maximum turn-on voltage for -B option is: 1VDC for DC control, 10Vrms for AC control, and 4Vrms for E control range. (9) For relays with option “G” minimum control voltage is 4.5VDC. (10) Must turn-off voltage for -B option is: 3VDC for DC control, 90Vrms for AC control, and 18Vrms for E control range. (11) Turn-on time for Instantaneous turn-on versions is 0.02 msec (DC Control Models). (12) All parameters at 50% power rating and 100% duty cycle (contact Crydom tech support for detailed report). (13) Load can be wired to either SSR output terminal 1 or 2. (14) Elective Input Status LED, “G” option. (15) Elective Overvoltage Protection, “P” option. (16) Mechanical dimensions vary from G3 models.
0.01 0.1 1 10 Surge Current (Amp) Surge Duration (Secs) 10 A 100 150 200 250 0.01 0.1 1 10 Surge Current (Amp) Surge Duration (Secs) 25 A 100 200 300 400 500 600 0.01 0.1 1 10 Surge Current (Amp) Surge Duration (Secs) 40 A Non repetitive peak surge current at Tj initial 40ºC. THERMAL DERATE INFORMATION 20 30 40 50 60 70 80 Ambient Temperature (ºC) Load Current (Amps) 40 A 1ºC/W 1.5ºC/W 2ºC/W 3.5ºC/W 20 30 40 50 60 70 80 Ambient Temperature (ºC) Load Current (Amps) 10 A 3ºC/W 5ºC/W No Heatsink 20 30 40 50 60 70 80 Ambient Temperature (ºC) Load Current (Amps) 25 A 1.5ºC/W 2ºC/W 3ºC/W DatasheetPanel Mount Do not forget to visit us at: www.crydom.com Copyright © 2016 Crydom Inc. Specifications subject to change without notice. DatasheetPanel Mount Do not forget to visit us at: www.crydom.com Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
Part No. Thermal Resistance [ºC/W] Lug Terminal Thermal Pad KS101 HK1 HK4 TRM1 TRM6 HSP-1 HSP-2 HS501DR HS301 / HS301DR HS251 HS202 / HS202DR HS201 / HS201DR HS172 HS151 / HS151DR HS122 / HS122DR HS103 / HS103DR HS101 HS073 HS072 HS053 HS033 HS023 5.0 3.0 2.5 2.0 2.0 1.7 1.5 1.2 1.0 1.0 0.7 0.7 0.5 0.36 0.25 AGENCY APPROVALS Designed in accordance with the requirements of IEC 62314 IEC 61000-4-2 : Electrostatic Discharge – Level 3 IEC 61000-4-4 : Electrically Fast Transients – Level 3 IEC 61000-4-5 : Electrical Surges – Level 3 IEC 60068-2-6 : Vibration 0.33mm and 0.75 mm Amplitude over 10-55 Hz IEC 60068-2-27 : Shock Resistance 15g/11ms E116949 LR81689 10143 UG (Not Applicable: -B and 4D) ACCESORIES Rev. 061716 Part number: KS101 Clear plastic cover compatible with all new S1 designs. Safety covers provide added protection from electric shock when installing or checking equipment. Protective Cover Hardware Kit Part number: HK4 Bag with 2 square brass accessories and 2 screw 8-32 x 5/8 for output. Used to mount TMR1 lug terminals. New Accessories! Protective Cover & Hardware Kits DatasheetPanel Mount Do not forget to visit us at: www.crydom.com Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
DANGER / PELIGRO / DANGER /GEFAHR / PERICOLO / 危险 HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH.
- Disconnect all power before installing or working with this equipment.
- Verify all connections and replace all covers before turning on power. Failure to follow these instructions will result in death or serious injury. RIESGO DE DESCARGA ELECTRICA O EXPLOSION.
- Desconectar todos los suministros de energia a este equipo antes de trabajar con este equipo.
- Verificar todas las conexiones y colocar todas las tapas antes de energizer el equipo. El incumplimiento de estas instrucciones puede provocar la muerte o lesiones serias. RISQUE DE DESCHARGE ELECTRIQUE OU EXPLOSION
- Eteindre toutes les sources d'énergie de cet appareil avant de travailler dessus de cet appareil
- Vérifier tous connections, et remettre tous couverts en olace avant de mettre sous De non-suivi de ces instructions provoquera la mort ou des lésions sérieuses sérieuses. GEFAHR EINES ELEKTRISCHE N SCHLAGES ODER EINER EXPLOSION.
- Stellen Sie jeglichen Strom ab, der dieses Gerät versorgt, bevor Sie an dem Gerät Arbeiten durchführen
- Vor dem Drehen auf Energie alle Anschlüsse überprüfen und alle Abdeckungen ersetzen. Unterlassung dieser Anweisungen können zum Tode oder zu schweren Verletzungen führen. RISCHIO DI SCOSSA ELETTRICA O DELL’ESPLOSIONE.
- Spenga tutta l'alimentazione che fornisce questa apparecchiatura prima di lavorare a questa apparecchiatura
- Verificare tutti i collegamenti e sostituire tutte le coperture prima dell’accensione L'omissione di queste istruzioni provocherà la morte o lesioni serie 存在电击、 爆炸或电弧 闪烁危险
- 在操作此设 备之前请先 关闭电源。 若不遵守这些说明, 可能会导致严重的 人身伤害甚至死亡。 WARNING / AVERTISSEMENT / WARNUNG /ADVERTENCIA / AVVERTENZA / ࠂܯ RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE
- The product's side panels may be hot, allow the product to cool before touching.
- Follow proper mounting instructions including torque values.
- Do not allow liquids or foreign objects to enter this product. Failure to follow these instructions can result in serious injury, or equipment damage. RISQUE DE DOMMAGE MATERIEL ET DE SURCHAUFFE DU BOITIER
- Les panneaux latéraux du produit peuvent être chauds. Laisser le produit refroidir avant de le toucher.
- Respecter les consignes de montage, et notamment les couples de serrage.
- Ne pas laisser pénétrer de liquide ni de corps étrangers à l'intérieur du produit. Le non-respect de cette directive peut entraîner, des lésions corporelles graves ou des dommages matériels. Die Nichtbeachtung dieser Anweisung kann Körperverletzung oder Materialschäden zur Folge haben. GEFAHR VON MATERIALSCHÄDEN UND GEHÄUSEERHITZUNG
- Die Seitenwände können heiß sein. Lassen Sie das Produkt abkühlen, bevor Sie es berühren.
- Beachten Sie die Montageanweisungen,
- Führen Sie keine Flüssigkeiten oder Fremdkörper in das Produkt ein. Si no se respetan estas precauciones pueden producirse graves lesiones, daños materiales. RIESGO DE DAÑOS MATERIALES Y DE SOBRECALENTAMIENTO DE LA UNIDAD
- Los paneles laterales del producto pueden estar calientes. Esperar que el producto se enfríe antes de tocarlo.
- Respetar las instrucciones de montaje, y en particular los pares de apretado.
- No dejar que penetren líquidos o cuerpos extraños en el producto. La mancata osservanza di questa precauzione può causare gravi rischi per l'incolumità personale o danni alle apparecchiature. RISCHIO DI DANNI MATERIALI E D'INVOLUCRO CALDO
- I pannelli laterali dell'apparecchio possono scottare; lasciar quindi raffreddare il prodotto prima di toccarlo.
- Seguire le istruzioni di montaggio corrette.
- Non far entrare liquidi o oggetti estranei in questo apparecchio. 如不能正确执行这些操作说明, 极有可能造成严重人体伤害或者设备的损坏。 材料损坏和高温外壳的危险性
- 产品的一侧面板可能很热,在其冷却前请 不要触碰。
- 遵照正确的安装说明,包括扭矩值。
- 请勿让液体及其他异物进入本产品。 Do not forget to visit us at: www.crydom.com Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
ANNEX - ENVIROMENTAL INFORMATION The environmental information disclosed in this annex including the EIP Pollution logo are in compliance with People’s Republic of China Electronic Industry Standard SJ/T11364 – 2006, Marking for Control of Pollution Caused by Electronic Information Products. Part Name Toxic or hazardous Substance and Elements Lead Mercury Cadmium Hexavalent Polybrominated Polybrominated (Pb) (Hg) (Cd) Chromium (Cr (VI)) biphenyls (PBB) diphenyl ethers (PBDE) Semiconductor die Solder 附件 - 环保信息 ሰྛြѓሙ4+5 有毒有害物质或元素件部 名称 铅 汞 镉 六价铬 多溴联苯 多溴二苯醚 (Pb) (Hg) (Cd) (Cr (VI)) (PBB) (PBDE) 半导体芯片 焊接点 DatasheetPanel Mount Do not forget to visit us at: www.crydom.com Copyright © 2016 Crydom Inc. Specifications subject to change without notice.