  • Multi-pole and multi-position
  • Positive detent
  • Shorting & non-shorting contacts
  • Panel and PCB mounting
  • RoHS Compliant Typical Applications
  • Automotive
  • Major and small appliances
  • Industrial equipment Specifications CONTACT RATING: Q contact material: Switch - 2.5 AMPS @ 125 V AC; 350 mA @ 125 V DC (UL/CSA). Carry - 5 AMPS continuous. See page L-6 for additional ratings. ELECTRICAL LIFE: 15,000 make-and-break cycles at full load up to 300,000 detent operations. CONTACT RESISTANCE: Below 20 m Ω typ. initial @ 2-4 V DC, 100 mA, for both silver and gold plated contacts. INSULATION RESISTANCE: 10 9 Ω min. DIELECTRIC STRENGTH: 1,000 Vrms min. @ sea level. Operating and storage temp: -30º to 85ºC OPERATING & STORAGE TEMPERATURE: -30ºC to 85ºC NOTE: Any models supplied with Q, B or G contact material ar e RoHS compliant. NOTE: Specifications and materials listed above are for switches with standard options. For information on specific and custom switches, consult Customer Service Center . Materials HOUSING & BUSHING: Glass filled 6/6 nylon (UL 94V-0). ACTUATOR: Glass filled 6/6 nylon (UL 94V-0). MOVABLE CONTACTS: Q contact material: Coin silver, silver plated. See page K-6 for additional contact materials. STATIONARY CONTACTS & TERMINALS: Q contact material: Brass, silver plated. See page K-6 for additional contact materials. HARDWARE: Nut - zinc, nickel plated. Lockwasher — steel, bright zinc plated. Stop Ring - brass, nickel plated. TERMINAL SEAL: Epoxy.Build-A-Switch To order, simply select desired option from each category and place in the appropriate box. Available options are shown and described on pages K–4 through K–7. For additional options not shown in catalog, consult Customer Service Center. Switch Function A100 SP, 30° Index, 12 pos. no stops A102 SPDT, 30° Index A103 SP , 30° Index, 3 pos. A104 SP , 30° Index, 4 pos. A105 SP , 30° Index, 5 pos. A106 SP , 30° Index, 6 pos. A107 SP , 30° Index, 7 pos. A108 SP , 30° Index, 8 pos. A109 SP , 30° Index, 9 pos. A110 SP , 30° Index, 10 pos. A112 SP , 30° Index, 12 pos. A114 SP, 90° Index, 2 pos. A115 SP , 45° Index, 3 pos. A124 SP , 90° Index, 4 pos. A125 SP, 45° Index, 8 pos. A203 DP , 30° Index, 3 pos. A204 DP , 30° Index, 4 pos. A205 DP , 30° Index, 5 pos. A206 DP , 30° Index, 6 pos. A214 DP, 90° Index, 2 pos. A303 3P , 30° Index, 3 pos. A304 3P , 30° Index, 4 pos. A402 4PDT, 30° Index A403 4P , 30° Index, 3 pos Contact Material Q Silver B Gold G Gold over silver Actuator 15 1.500" high, flatted 03 .375" high, flatted 05 .500" high, flatted 14 1.500" high, flatted 42 1.654" high, metric S1 Screwdriver Slot Shorting/ Non-shorting Contacts N Non-shorting contacts S Shorting contacts (Not available with models A114, A124 & A214) Terminations Z Solder lug C PC Thru-hole MC Modular base Seal NONE No seal E Epoxy seal F Splashproof bushing seal K Epoxy & splashproof bushing seal Mounting Style R 3/8-32 threaded M M10 x .75 metric K–3 Dimensions are shown: Inch (mm) Specifications and dimensions subject to change www.ck-components.com KRotary

K–4 Dimensions are shown: Inch (mm) Specifications and dimensions subject to change www.ck-components.com A Series 1-4 Pole Rotary Switches SWITCH FUNCTION 3P MODELS SCHEMATIC 4P MODELS SCHEMATIC DP MODELS SCHEMATIC SP MODELS SCHEMATIC 3P MODELS TERMINAL NUMBERS 4P MODELS SP MODELS (omit terminals B, C & D) DP MODELS (omit terminals B & D) Terminal numbers molded on bottom of housing. All Terminals3 PositionA403 A,B,C,D,1,2,4,5,7, 8,10,114PDTA402 TERMINALSSWITCH FUNCTION MODEL NO. NO. POLES 30º INDEXING A,1,2,4,5,7,8,10,118 PositionA125 A,1,2,4*3 PositionA115 SP TERMINALSSWITCH FUNCTION MODEL NO. NO. POLES 45º INDEXING A,C,1,4,7,102 PositionA214DP A,1,4,7,104 PositionA124 A,1,4*2 PositionA114 SP TERMINALSSWITCH FUNCTION MODEL NO. NO. POLES 90º INDEXING NOTE: * These models with ‘C’ or ‘MC’ terminations have additional terminal no. 9 as switch support only. This terminal is not connected electrically inside switch. All models with all options when ordered with ‘G’ or ‘Q’ contact material, see page K-6. A,B,C,1-124 PositionA304 A,B,C,1-3,5-7 9-113 PositionA303 A,C,1-126 PositionA206 A,C,1-5,7-115 PositionA205 A,C,1-4,7-104 PositionA204 A,C,1-3,7-93 PositionA203 DP A,1-1212 PositionA112 A,1-1010 PositionA110 A,1-99 PositionA109 A,1-88 PositionA108 A,1-77 PositionA107 A,1-6*6 PositionA106 A,1-5*5 PositionA105 A,1-4*4 PositionA104 A,1-3*3 PositionA103 A,1,2*SPDTA102 A,1-1212 Position No StopsA100 SP TERMINALSSWITCH FUNCTION MODEL NO. NO. POLES 30º INDEXING

K–5 Dimensions are shown: Inch (mm) Specifications and dimensions subject to change www.ck-components.com KRotary A Series 1-4 Pole Rotary Switches ACTUATOR MOUNTING STYLE SHORTING/NON-SHORTING CONTACTS METRIC BUSHING PANEL MOUNTING 3/8 IN. BUSHING PANEL MOUNTING TYPICAL INSTALLATION NUT LOCKWASHER Maximum force to push on knob should not exceed 10 in./lbs. S SHORTING CONTACTS (make-before-break) N NON-SHORTING CONTACTS (break-before-make) R 3/8-32 THREAD M M10 x .75 METRIC Install switch with stop ring (if used) and lockwasher in back of panel. Tighten hex nut from front of panel. On PC mounted switches, use hex nut and lockwasher to hold stop ring in place. Actuation torque: 8–16 oz./in. Maximum torque: 30 oz./in. NOTE: ‘S’ shorting contacts are not available with A114, A124 and A214 models. NOTE: Actuators shown in position 1, fully CCW.

K–6 Dimensions are shown: Inch (mm) Specifications and dimensions subject to change www.ck-components.com A Series 1-4 Pole Rotary Switches PC MOUNTING 4P MODEL SP MODEL (omit terminals B, C & D) DP MODEL (omit terminals B & D) 3P MODEL Z SOLDER LUG MC MODULAR BASE (for wave soldering)C PC THRU-HOLE NOTE: Switches with ‘C’ or ‘MC’ terminations have additional terminal no. 9 as switch support only. This terminal is not connected electrically inside switch. Solder and clean switch base on PC board with other components, then snap on housing/actuator assembly. See page K-7 for installation instructions. CONTACT MATERIAL TERMINATIONS * Note: See Technical Data section of this catalog for RoHS compliant and compatible definition and specifications. 1 MOVABLE CONTACTS: Copper alloy, with gold plate over nickel plate. STATIONARY CONTACTS & TERMINALS: Brass, with gold plate over nickel plate. 2 MOVABLE CONTACTS: Coin silver, silver plated. STATIONARY CONTACTS & TERMINALS: Brass, silver plated (standard with all termination options). 3 MOVABLE CONTACTS: Coin silver, with gold plate over nickel plate over silver plate. STATIONARY CONTACTS & TERMINALS: Brass, with gold plate over nickel plate over silver plate. All models with all options when ordered with ‘G’ or ‘Q’ contact material. NOTE: ‘G’ contact material is equivalent to both ‘B’ and ‘Q” contact materials. NOTE: Any models supplied with Q, B or G contact material ar e RoHS compliant. CONTACT ANDOPTION CODE TERMINAL MATERIAL RATING Q SWITCH-2.5 AMPS @ 125 V AC; 350 mA @ 125V DC (UL/CSA). CARRY-5 AMPS CONTINUOUS. LOW LEVEL/DRY CIRCUITB SILVER 2 POWER 0.4 VA MAX. @ 20 V AC or DC MAX LOW LEVEL/DRY CIRCUIT OR POWERG GOLD 1 GOLD OVER SILVER 3 0.4 VA MAX. @ 20 V AC or DC MAX. or SWITCH-2.5 AMPS @ 125 V AC; 350 mA @ 125 V DC (UL/CSA). CARRY-5 AMPS CONTINUOUS.

K–7 Dimensions are shown: Inch (mm) Specifications and dimensions subject to change www.ck-components.com KRotary A Series 1-4 Pole Rotary Switches FUNCTION AVAILABLE HARDWARE SPLASHPROOF BUSHING SEAL (FIG. 1) (FIG. 2) (FIG. 3) REMOVABLE CLIP LOCATING TA B STANDOFF K EPOXY & SPLASHPROOF BUSHING SEALF SPLASHPROOF BUSHING SEALNONE NO SEAL E EPOXY SEAL Stop ring PART NO. 767B00201 Material: Brass Finish: Nickel plated Setting Stops on A112 and A125 Models The number of switch positions is adjustable on A112 and A125 models only by means of a stop ring provided with each switch. The number of positions is pre-set on all other models and the stop ring is factory installed. Soldering 1. Insert switch base only into PC board. 2. Do not bend terminals. 3. Wave soldering recommended at 500F solder temperature. 4. Hand solder at 500F, 10 sec. max./terminal. Switch Assembly 1. Hold housing/shaft assembly by housing. Remove protective cap by squeezing tabs and discar d. (FIG. 1) 2. Do not push on switch shaft. Detent mechanism will come apart. 3. While holding switch housing, align locating tab on base with notch on housing and engage 4 housing latches in slots on base. (FIG. 2) 4. Push firmly on housing until latches snap in place. 5. Remove clip from shaft and discard. Assembly is complete. (FIG. 3) Cleaning 1. Flux clean using vapor degreaser and forced rinse or triple bath method. 2. Do not allow switch base to ‘trap’ fluids. 3. Freon TMC, TF or Methylene Chloride give excellent results. To set stops: Turn shaft fully counter-clockwise and insert stop ring tab in desired hole. Install lockwasher and nut to retain stop ring for both PC and panel mounting. Switch without stop ring has 12 positions. Soldering, Cleaning and Assembly Instructions for ‘MC’ Termination Option