The copyright and authority for the interpretation of the products are reserved by Mornsun Specifications subject to change without notice. A_(X)T-W2 A/1-2008 Page 1 of 2 A_(X)T-W2 Series 0.25W,FIXED INPUT, ISOLATED & UNREGULATED DUAL OUTPUT, SMD DC-DC CONVERTER multi-country patent protection RoHS PRODUCT PROGRAM Input Output Voltage (VDC) Current (mA) Part Number Nominal Range Voltage (VDC) Max Min Efficiency (%, Typ.) A0505(X)T-W2 ±5 ±25 ±3 64 A0509(X)T-W2 ±9 ±14 ±2 65 A0512(X)T-W2 ±12 ±11 ±2 67 A0515(X)T-W2 5 4.5-5.5 ±15 ±9 ±1 66 A1205(X)T-W2 ±5 ±25 ±3 65 A1209(X)T-W2 ±9 ±14 ±2 64 A1212(X)T-W2 ±12 ±11 ±2 63 A1215(X)T-W2 12 10.8-13.2 ±15 ±9 ±1 64 A2405(X)T-W2 ±5 ±25 ±3 61 A2409(X)T-W2 ±9 ±14 ±2 62 A2412(X)T-W2 ±12 ±11 ±2 63 A2415(X)T-W2 24 21.6-26.4 ±15 ±9 ±1 65 Note: The A_XT-W2 series have no 3,6,8,9 pin. For example A0505XT-W2. ISOLATION SPECIFICATIONS Item Test Conditions Min Typ. Max Units Isolation voltage Tested for 1 minute and 1mA max 1000 VDC Isolation resistance Test at 500VDC 1000 M Ω OUTPUT SPECIFICATIONS Item Test Conditions Min Typ. Max Units Output power 0.25 W For Vin change of 1%(3.3V output) ±1.5 Line regulation For Vin change of 1%(Others output) ±1.2 10% to 100% load (3.3V output) 15 20 10% to 100% load (5V output) 12.8 15 10% to 100% load (9V output) 8.3 15 10% to 100% load (12V output) 6.8 15 Load regulation 10% to 100% load (15V output) 6.3 15 Output voltage accuracy See tolerance envelope graph Temperature drift 100% full load 0.03 %/°C Output ripple &Noise* 20MHz Bandwidth 50 100 mVp-p Full load, nominal input(24V input) 500 Switching frequency Full load, nominal input (others input) 110 KHz
FEATURES
Temperature Range: -40°C to +85°C Internal SMD construction No External Component Required Industry Standard Pinout RoHS Compliance
APPLICATIONS
The A_(X)T-W2 Series are specially designed for applications where a group of polar power supplies are isolated from the input power supply in a distributed power supply system on a circuit board. These products apply to: 1) Where the voltage of the input power supply is fixed (voltage variation ≤ ±10%); 2) Where isolation is necessary between input and output (isolation voltage ≤1000VDC); 3) Where t he regulation of the output voltage and the output ripple noise are not demanding. Such as: purely digital circuits, ordinary low frequency analog circuits, and IGBT power device driving circuits. MODEL SELECTION A0505(X)T-W2 Product Series Input Voltage Output Voltage Package Style Rated Power MORNSUN Science & Technology co.,Ltd. Address: 2th floor 6th building, Huangzhou Industrial District, Guangzhou, China Tel: 86-20-38601850 Fax:86-20-38601272 Http://www.mornsun-power.com *Test ripple and noise by “parallel cable ” me thod. See detailed operation instructions at Testing of Power Converter section, application notes.
The copyright and authority for the interpretation of the products are reserved by Mornsun Specifications subject to change without notice. A_(X)T-W2 A/1-2008 Page 2 of 2 COMMON SPECIFICATION APPLICATION NOTE Item Test Conditions Min Typ. Max Units Storage humidity 95 % Operating temperature -40 85 Storage temperature -55 125 Temp. rise at full load 15 25 Lead temperature 1.5mm from case for 10 seconds 260 Cooling Free air convection Case material Plastic(UL94-V0) Short circuit protection* 1 s MTBF 3500 K hours Weight 1.70 g *Supply voltage must be discontinued at the end of short circuit duration. TYPICAL CHARACTERISTICS Operating Temp.(C) o RECOMMENDED REFLOW SOLDERING PROFILE 100 150 200 250 Time (sec.) 220C o
10 MaxSec
o
90 Max
(>220C) o Sec Temperature ( C) o OUTLINE DIMENSIONS & FOOTPRINT DETAILS Vin GND -Vo 7 +Vo 6.50 2.54 0.25 4.25 1.35 0.50 5.00 。 1.85 0.25 A 6.76 7.15 11.20 15.24 10.16 2.540.10 6.257.50 0.600.05 (0.250) (0.240) (0.167) (0.100) (0.010) (0.600) (0.400) (0.295) (0.441) (0.266) (0.020) (0.053) Vin GND -Vo NC10 NC +Vo First Angle Projection RECOMMENDED FOOTPRINT Top view,grid:2.54mm(0.1inch) FOOTPRINT DETAILS Pin Function(T) Function(XT) NC:No Connection Note: Unit:mm(inch) Pin section:0.60*0.25mm(0.024*0.010inch) Pin section tolerances:0.10mm(0.004inch) General tolerances:0.15mm(0.006inch) 3689,,, NC NO PIN 1 2 3 4 5 8 7 6 A_T-W2 A_XT-W2 910 1 2 4 5 710 1.8 1.2 (0.047) Requirement on output load To ensure this module can operate efficiently and reliably, During operation, the minimum output load is not less than 10% of the full load, and that this product should never be operated under no load! If the actual output power is very small, please connect a resistor with proper resistance at the output end in parallel to increase the load. Recommended circuit If you want to further decrease the input/output ripple, an “LC” filtering network may be connected to the input and output ends of the DC/DC converter, see (Figure 1). Vin GND +Vo 0VDCC L L DC L C C -Vo (Figure 1) It should also be noted that the inductance and the frequency of the “LC” filtering network should be staggered with the DC/DC frequency to avoid mutual interference. However, the capacitance of the output filter capacitor must be proper. If the capacitance is too big, a startup problem might arise. It ’s not recommended to connect any external capacitor in the application field. Output Voltage Regulation and Over- voltage Protection Circuit The simplest device for output voltage regulation, over-voltage and over-current protection is a linear voltage regulator with overheat protection that is connected to the input or output end in series (Figure2). Vin GND Vin GND REG +Vo -Vo +Vo DCDC DCDC REG REG -Vo (Figure2) Overload Protection Under normal operating conditions, the output circuit of these products has no protection against over-current and short-circuits. The simplest method is to connect a self-recovery fuse in series at the input end or add a circuit breaker to the circuit. No parallel connection or plug and play. Note: 1. All specifications measured at Ta=25 °C, humidity<75%, nominal input voltage and rated output load unless otherwise specified. 2. Only typical models listed, specifications o f custom product may be different. Please contact our service people directly for certain conditions. 3. Operation under minimum load will not damage the converter; However, they may not meet all specification listed.