Product: A02141O TC-ER VN/PVC, 2+G C #14 Str BC, PVC-NYL Ins, E1, 1 C #14 Str BC Ins Grnd, Blk PVC Jkt, 600V TC-ER 150V NPLF 90C Dry 75C Wet SUN RES DIR BUR Product Description UL Type TC-ER (1277) PVC-Nylon/PVC, 2+G Conductor 14AWG (7x22) Bare Copper, PVC-NYL Insulation E1 Color Code, 1 Conductor 14 (7x22) Bare Copper Insulated Ground, Black PVC Outer Jacket, 600V TC-ER 150V NPLF 90C Dry 75C Wet SUN RES DIR BUR Technical Specifications Physical Characteristics (Overall) Conductor Element AWG Stranding Material No. of Conductors Conductor(s) 14 7x22 BC - Bare Copper 2 Ground 14 7x22 BC - Bare Copper 1 Conductor Count: 2 Insulation Material Nominal Diameter Nominal Wall Thickness PVC/Nylon - Polyvinyl Chloride + Nylon 0.116 in 0.0225 in PVC/Nylon - Polyvinyl Chloride + Nylon 0.116 in 0.0225 in Color Chart Number Color
1 Black
2 White
Material Nominal Diameter Nominal Wall Thickness PVC - Polyvinyl Chloride 0.344 in 0.047 in
Electrical Characteristics
2.52 Ohm/1000ft
Max. Recommended Current [A]
25 Amps per Conductor at 30ºC
UL Description UL Voltage Rating Voltage Rating [V] TC 600 V RMS (Type TC) 600 V RMS (Type TC) NPLF 150 V RMS (NPLF) Temperature Range Operating Temperature Range: -30°C to 90°C Dry, +75°C Wet
Mechanical Characteristics Bulk Cable Weight: 73 lbs/1000ft Max. Pull Tension: 97 lbs Min. Bend Radius/Minor Axis: 1.38 in Standards NEC Articles: Article 336 NEC/(UL) Compliance: NPLF, TC-ER, THWN-2 Singles Applicable Environmental and Other Programs EU Directive 2000/53/EC (ELV): Yes EU Directive 2003/11/EC (BFR): Yes EU Directive 2011/65/EU (RoHS 2): Yes EU Directive 2012/19/EU (WEEE): Yes EU Directive 2015/863/EU (RoHS 2 amendment): Yes EU Directive Compliance: EU Directive 2003/11/EC (BFR) EU CE Mark: Yes Suitability Suitability - Burial: Yes Suitability - Indoor: Yes Suitability - Outdoor: Yes Suitability - Sunlight Resistance: Yes Flammability, LS0H, Toxicity Testing UL Flammability: UL1685 UL Loading IEEE Flammability: 1202 UL voltage rating: 600 V RMS (Type TC) Related Part Numbers Variants Item # Put-Up Type A02141O 0105000 Reel History Update and Revision: Revision Number: 0.50 Revision Date: 12-22-2023 © 2024 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product.