Features

■Miniature design ■Analog output 4…20 mA ■Factory setting: 0…150 °C ■Parameterizable via IO-Link ■Analog output 4…20 mA (2-wire) ■Switching output ■Compression fitting process connection ■Bendable probe (min. bending radius: 3x outer diameter; excluding 30-mm probe tip) Wiring diagram Functional principle The TTM miniature transmitters are available with integrated probe. Due to the integrated electronics, the limited temperature range must be observed, especially in the area of the M12 connector.

TURCK Inc. | 3000 Campus Drive Minneapolis, MN 55441-2656 | Phone: 763-553-7300 | Application Support: 1-800-544-7769 | Fax 763-553-0708 | www.turck.com 2|5 TTM-206A-CF-LIUPN-H1140-L050 | 11/08/2023 00-25 | technical changes reserved Technical data Switching point accuracy ± 0.3 K Rated operational current 0.15 A Release position -210…+640 °C Switching point -200…+650 °C Switching cycles ≥ 100 mil. Analog output Current output 4…20 mA Load ≤ [(Vsupply - 10 V)/21 mA] kΩ Accuracy (Lin. + Hys. + Rep.) ± 0.3 K Remark 0.1 % of full scale applies to temperatures > +300 °C Repeatability 0.1 K IO-Link IO-Link specification V 1.1 Transmission physics corresponds to 3-wire physics (PHY2) Frame type 2.2 Transmission rate COM 2 / 38.4 kbps Process data width 16 bit Measured value information 15 bit Switchpoint information 1 bit Programming FDT / DTM Genauigkeit ± 0.2 K Included in the SIDI GSDML Yes Mechanical data Housing material Stainless-steel/Plastic, 1.4404 (AISI 316L) Process connection For compression fittings, thermowell or direct mounting Electrical connection Connector, M12 × 1 Protection class IP67 Environmental conditions Ambient temperature -40…+80 °C Storage temperature -40…+80 °C Tests/approvals Reference conditions acc. to IEC 61298-1 Temperature 15…+25 °C Atmospheric pressure 860…1060 hPa abs. Humidity 45…75 % rel.

TURCK Inc. | 3000 Campus Drive Minneapolis, MN 55441-2656 | Phone: 763-553-7300 | Application Support: 1-800-544-7769 | Fax 763-553-0708 | www.turck.com 3|5 TTM-206A-CF-LIUPN-H1140-L050 | 11/08/2023 00-25 | technical changes reserved Technical data Auxiliary power 24 VDC Temperature behaviour Temperature coefficient range TKs ± 0.1 % of full scale/10 K Temperature coefficient zero point TK0 ± 0.1 % of full scale/10 K MTTF 541 years acc. to SN 29500 (Ed. 99) 40 Technical data Type TTM-206A-CF-LIUPN-H1140-L050 ID 9910809 Temperature range Measuring range -210…650 °C Measuring range -346…1202 °F Factory setting 0…150 °C 32…302 °F Note Max. temperature of electronics: 80 °C/176 °F Accuracy ±0.15 K + 0.002 ∙|t| (-30…300 °C) Measuring element Pt-100 probe, DIN EN 60751, class A Response time t₀₅ = 1.5 s / t₀₉ = 6.0 s in water @ 0.2 m/s Immersion depth (L) 50 mm Outer diameter 6 mm Power supply Operating voltage 15…30 VDC Current consumption ≤ 20 mA Voltage drop at Ie ≤ 2 V Short-circuit/reverse polarity protection yes / yes Protection type and class IP67 / III Outputs Output 1 Switching output or IO-Link mode Output 2 Analog output Switching output Communication protocol IO-Link Output function NO/NC programmable, PNP/NPN Note Connection to PIN 1+3+4. Please use a 3-wire cable for operation on a Turck TBEN IO-Link master. Switching point accuracy ± 0.3 K Rated operational current 0.15 A Switching cycles ≥ 100 mil.

TURCK Inc. | 3000 Campus Drive Minneapolis, MN 55441-2656 | Phone: 763-553-7300 | Application Support: 1-800-544-7769 | Fax 763-553-0708 | www.turck.com 4|5 TTM-206A-CF-LIUPN-H1140-L050 | 11/08/2023 00-25 | technical changes reserved Technical data Release position -210…+640 °C Switching point -200…+650 °C Analog output Current output 4…20 mA Note Connection to PIN 1+2 Load ≤ [(Vsupply - 10 V)/21 mA] kΩ Accuracy (Lin. + Hys. + Rep.) ± 0.3 K Remark 0.1 % of full scale applies to temperatures > +300 °C Repeatability 0.1 K IO-Link IO-Link specification V 1.1 Programming FDT / DTM Transmission physics corresponds to 3-wire physics (PHY2) Transmission rate COM 2 / 38.4 kbps Process data width 16 bit Measured value information 15 bit Switchpoint information 1 bit Frame type 2.2 Genauigkeit ± 0.2 K Included in the SIDI GSDML Yes Temperature behaviour Temperature coefficient zero point TK0 ± 0.1 % of full scale/10 K Temperature coefficient range TKs ± 0.1 % of full scale/10 K Environmental conditions Ambient temperature -40…+80 °C Storage temperature -40…+80 °C Mechanical data Housing material Stainless-steel/Plastic, 1.4404 (AISI 316L) Sensor material Stainless steel, 1.4404 (AISI 316L) Process connection For compression fittings, thermowell or direct mounting Process Pressure 100 bar Electrical connection Connector, M12 × 1 Reference conditions acc. to IEC 61298-1 Temperature 15…+25 °C Atmospheric pressure 860…1060 hPa abs.

TURCK Inc. | 3000 Campus Drive Minneapolis, MN 55441-2656 | Phone: 763-553-7300 | Application Support: 1-800-544-7769 | Fax 763-553-0708 | www.turck.com 5|5 TTM-206A-CF-LIUPN-H1140-L050 | 11/08/2023 00-25 | technical changes reserved Technical data Humidity 45…75 % rel. Auxiliary power 24 VDC Tests/approvals MTTF 541 years acc. to SN 29500 (Ed. 99) 40