9910655 TURCK | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 5
Technical content
Features
■Miniature design ■Measuring range 0…X °C (special item: Measuring range must be set by customer service!) ■Parameterizable via IO-Link ■Analog output 4…20 mA (2-wire) ■Switching output ■For connection to external temperature probes Wiring diagram Functional principle TP temperature probes (PT100 4-wire) can be plugged directly or via cable to the M12 connection at the TTM100 temperature transmitter. The temperature signal is transformed into an analog output signal (2-wire 4…20mA)
TURCK Inc. | 3000 Campus Drive Minneapolis, MN 55441-2656 | Phone: 763-553-7300 | Application Support: 1-800-544-7769 | Fax 763-553-0708 | www.turck.com 2|5 TTMS-100-LIUPN-H1140/S713 | 11/08/2023 00-26 | technical changes reserved Technical data Output function NO/NC programmable, PNP/NPN Switching point accuracy ± 0.3 K Rated operational current 0.15 A Release position -210…+640 °C Switching point -200…+650 °C Switching cycles ≥ 100 mil. Analog output Current output 4…20 mA Load ≤ [(Vsupply - 10 V)/21 mA] kΩ Accuracy (Lin. + Hys. + Rep.) ± 0.3 K Remark 0.1 % of full scale applies to temperatures > +300 °C Repeatability 0.1 K IO-Link IO-Link specification V 1.1 Transmission physics corresponds to 3-wire physics (PHY2) Frame type 2.2 Transmission rate COM 2 / 38.4 kbps Process data width 16 bit Measured value information 15 bit Switchpoint information 1 bit Programming FDT / DTM Genauigkeit ± 0.2 K Included in the SIDI GSDML Yes Mechanical data Housing material Stainless steel, 1.4404 (AISI 316L) Process connection M12 × 1 Electrical connection Connector, M12 × 1 Protection class IP67 Environmental conditions Ambient temperature -40…+80 °C Storage temperature -40…+80 °C Tests/approvals Reference conditions acc. to IEC 61298-1 Temperature 15…+25 °C Atmospheric pressure 860…1060 hPa abs. Humidity 45…75 % rel. Auxiliary power 24 VDC and a switching signal. IO-Link is available for communication and programming.
TURCK Inc. | 3000 Campus Drive Minneapolis, MN 55441-2656 | Phone: 763-553-7300 | Application Support: 1-800-544-7769 | Fax 763-553-0708 | www.turck.com 3|5 TTMS-100-LIUPN-H1140/S713 | 11/08/2023 00-26 | technical changes reserved Technical data Temperature behaviour Temperature coefficient range TKs ± 0.1 % of full scale/10 K Temperature coefficient zero point TK0 ± 0.1 % of full scale/10 K MTTF 541 years acc. to SN 29500 (Ed. 99) 40 Technical data Type TTMS-100-LIUPN-H1140/S713 ID 9910655 Special version S713 corresponds to: Customer-specific adjustment of measuring range by customer service Temperature range Measuring range -210…650 °C Measuring range -346…1202 °F Factory setting 0…150 °C 32…302 °F Note Max. temperature of electronics: 80 °C/176 °F Measuring element For connection to probes of the TP series Response time depending on connected temperature probe Power supply Operating voltage 15…30 VDC Current consumption ≤ 20 mA Voltage drop at Ie ≤ 2 V Short-circuit/reverse polarity protection yes / yes Protection type and class IP67 / III Outputs Output 1 Switching output or IO-Link mode Output 2 Analog output Switching output Communication protocol IO-Link Output function NO/NC programmable, PNP/NPN Note Connection to PIN 1+3+4. Please use a 3-wire cable for operation on a Turck TBEN IO-Link master. Switching point accuracy ± 0.3 K Rated operational current 0.15 A Switching cycles ≥ 100 mil. Release position -210…+640 °C
TURCK Inc. | 3000 Campus Drive Minneapolis, MN 55441-2656 | Phone: 763-553-7300 | Application Support: 1-800-544-7769 | Fax 763-553-0708 | www.turck.com 4|5 TTMS-100-LIUPN-H1140/S713 | 11/08/2023 00-26 | technical changes reserved Technical data Switching point -200…+650 °C Analog output Current output 4…20 mA Note Connection to PIN 1+2 Load ≤ [(Vsupply - 10 V)/21 mA] kΩ Accuracy (Lin. + Hys. + Rep.) ± 0.3 K Remark 0.1 % of full scale applies to temperatures > +300 °C Repeatability 0.1 K IO-Link IO-Link specification V 1.1 Programming FDT / DTM Transmission physics corresponds to 3-wire physics (PHY2) Transmission rate COM 2 / 38.4 kbps Process data width 16 bit Measured value information 15 bit Switchpoint information 1 bit Frame type 2.2 Genauigkeit ± 0.2 K Included in the SIDI GSDML Yes Temperature behaviour Temperature coefficient zero point TK0 ± 0.1 % of full scale/10 K Temperature coefficient range TKs ± 0.1 % of full scale/10 K Environmental conditions Ambient temperature -40…+80 °C Storage temperature -40…+80 °C Mechanical data Housing material Stainless steel, 1.4404 (AISI 316L) Process connection M12 × 1 Process Pressure 100 bar Electrical connection Connector, M12 × 1 Reference conditions acc. to IEC 61298-1 Temperature 15…+25 °C Atmospheric pressure 860…1060 hPa abs. Humidity 45…75 % rel. Auxiliary power 24 VDC
TURCK Inc. | 3000 Campus Drive Minneapolis, MN 55441-2656 | Phone: 763-553-7300 | Application Support: 1-800-544-7769 | Fax 763-553-0708 | www.turck.com 5|5 TTMS-100-LIUPN-H1140/S713 | 11/08/2023 00-26 | technical changes reserved Technical data Tests/approvals MTTF 541 years acc. to SN 29500 (Ed. 99) 40