9910639 TURCK | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 3

Technical content

Features

■Pt‐100 probe acc. to DIN EN 60751 ■Vibration an shock-resistant ■Class A for temperatures < 350 °C ■Class B for temperatures > 350 °C ■Can be connected to TS, TTM, IM34, BL20, BL67 and excom ■Max. temperature connector: 120°C ■Connection mode: 4-wire connection ■Process connection via compression fitting or thermowell. Wiring diagram Functional principle Resistance thermometer are used everywhere where temperatures must be captured and monitored for the control and optimization of processes. Typical applications are process plants, manufacturing facilities and units, as well as air-conditioning systems. The core element of the temperature transmitters is a Pt 100 measuring resistor in 4-wire technology.

TURCK Inc. | 3000 Campus Drive Minneapolis, MN 55441-2656 | Phone: 763-553-7300 | Application Support: 1-800-544-7769 | Fax 763-553-0708 | www.turck.com 2|3 TPS-206A-CF-H1141-L150 | 11/08/2023 00-25 | technical changes reserved Technical data Tests/approvals Reference conditions acc. to IEC 61298-1 Temperature 15…+25 °C Atmospheric pressure 860…1060 hPa abs. Humidity 45…75 % rel. Auxiliary power 24 VDC Technical data Type TPS-206A-CF-H1141-L150 ID 9910639 Temperature range Measuring range -50…500 °C Measuring range -58…932 °F Accuracy ±0.15 K + 0.002 ∙|t| (-30…300 °C) Self-heating 0.4 K/mW at 0 °C Measuring element Pt-100 probe, DIN EN 60751, class A, connection mode: 4-wire connection Response time t 0.5 = 6 s / t 0.9 = 15 s in water at 0.2 m/ s Immersion depth (L) 150 mm Outer diameter 6 mm Short-circuit/reverse polarity protection yes Protection type and class IP67 Environmental conditions Ambient temperature -40…+120 °C Storage temperature -40…+85 °C Mechanical data Housing material Stainless steel, 1.4404 (AISI 316L) Sensor material Stainless steel, 1.4404 (AISI 316L) Process connection For compression fittings, thermowell or direct mounting Process Pressure 100 bar Electrical connection Connector, M12 × 1 Reference conditions acc. to IEC 61298-1 Temperature 15…+25 °C Atmospheric pressure 860…1060 hPa abs. Humidity 45…75 % rel. Auxiliary power 24 VDC

TURCK Inc. | 3000 Campus Drive Minneapolis, MN 55441-2656 | Phone: 763-553-7300 | Application Support: 1-800-544-7769 | Fax 763-553-0708 | www.turck.com 3|3 TPS-206A-CF-H1141-L150 | 11/08/2023 00-25 | technical changes reserved Technical data Tests/approvals