9843 BELDEN | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 3
Technical content
Part Number: 9843 RS485, 3 Pr #24 Str TC, PO Ins, OS+TC Brd, PVC Jkt, CM Product Description RS-485, 3 Pair 24AWG (7x32) Tinned Copper, PO Insulation, Overall Beldfoil®+Tinned Copper Braid(90%) Shield, PVC Outer Jacket, CM Technical Specifications Product Overview Suitable Applications: RS-485 Physical Characteristics (Overall) Conductor AWG Stranding Material No. of Pairs 24 7x32 TC - Tinned Copper 3 Conductor Count: 6 Total Number of Pairs: 3 Insulation Material Nominal Wall Thickness PE - Polyethylene 0.022 in Color Chart Number Color
1 White/Blue & Blue/White
2 White/Orange & Orange/White
3 White/Green & Green/White
Type Layer Material Material Trade Name Coverage [%] Drainwire Material Drainwire AWG Drainwire Construction n x D Tape 1 Aluminum/Polyester Beldfoil® 100 % TC - Tinned Copper 24 7x32 mm Braid 2 TC - Tinned Copper 90 % Outer Jacket Material Material Nominal Diameter Nominal Wall Thickness PVC - Polyvinyl Chloride 0.36 in 0.035 in
Electrical Characteristics
Nominal Conductor DCR Nominal Outer Shield DCR 24 Ohm/1000ft 2.3 Ohm/1000ft Capacitance Nom. Capacitance Conductor to Conductor Nom. Capacitance Conductor to Other Conductor to Shield 12.8 pF/ft 23 pF/ft Impedance Nominal Characteristic Impedance
120 Ohm
High Frequency (Nominal/Typical) Frequency [MHz] Nom. Insertion Loss 1 MHz 0.6 dB/100m Delay Max. Delay Skew Nominal Delay Nominal Velocity of Propagation (VP) [%] 66 ns/100m 1.6 ns/ft 66 % Current Max. Recommended Current [A] Per conductor @ 25°C: 1.54 A Voltage UL Description UL Voltage Rating UL AWM Style 2919 300 V RMS Temperature Range UL Temp Rating: 80°C (UL AWM Style 2919) Operating Temp Range: -30°C To +80°C Mechanical Characteristics Bulk Cable Weight: 62 lbs/1000ft Max Recommended Pulling Tension: 105.5 lbs Min Bend Radius/Minor Axis: 3.75 in Standards NEC Articles: 800 NEC/(UL) Specification: CM CEC/C(UL) Specification: CM UL AWM Style: 2919 (300 V 80°C) CPR Euroclass: Eca Applicable Environmental and Other Programs EU Directive 2000/53/EC (ELV): Yes EU Directive 2003/96/EC (BFR): Yes EU Directive 2011/65/EU (ROHS II): Yes EU Directive 2012/19/EU (WEEE): Yes EU Directive 2015/863/EU: Yes EU Directive Compliance: EU Directive 2003/11/EC (BFR) EU CE Mark: Yes EU RoHS Compliance Date (yyyy-mm-dd): 2004-01-01 CA Prop 65 (CJ for Wire & Cable): Yes MII Order #39 (China RoHS): Yes Flammability, LS0H, Toxicity Testing UL Flammability: UL1685 UL Loading ISO/IEC Flammability: IEC 60332-1-2 UL voltage rating: 300 V RMS Plenum/Non-Plenum Plenum (Y/N): No Part Number Variants Item # Color UPC Length Footnote
9843.00305 Chrome 305 m
9843 060100 Chrome 612825259589 100 ft 9843 0601000 Chrome 612825259596 1,000 ft C
9843 060500 Chrome 612825259602 500 ft C 9843 0605000 Chrome 612825259619 5,000 ft C 9843.K0305 Chrome 305 m Footnote: C - CRATE REEL PUT-UP. History Update and Revision: Revision Number: 0.325 Revision Date: 08-22-2019 © 2019 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product.