Part Number: 9841 RS485, 1 Pr #24 Str TC, PO Ins, OS+TC Brd, PVC Jkt, CM Product Description RS-485, 1 Pair 24AWG (7x32) Tinned Copper, PO Insulation, Overall Beldfoil®+Tinned Copper Braid(90%) Shield, PVC Outer Jacket, CM Technical Specifications Product Overview Suitable Applications: RS-485, DMX-512 Physical Characteristics (Overall) Conductor AWG Stranding Material No. of Pairs 24 7x32 TC - Tinned Copper 1 Conductor Count: 2 Total Number of Pairs: 1 Insulation Material Nominal Wall Thickness PE - Polyethylene 0.0225 in Color Chart Color White/Blue & Blue/White Outer Shield Material Type Layer Material Material Trade Name Coverage [%] Drainwire Material Drainwire AWG Drainwire Construction n x D Tape 1 Aluminum/Polyester Beldfoil® with shorting fold 100 % TC - Tinned Copper 24 7x32 mm Braid 2 TC - Tinned Copper 90 % Outer Jacket Material Material Nominal Diameter Nominal Wall Thickness PVC - Polyvinyl Chloride 0.232 in 0.035 in Construction and Dimensions Cabling Lay Direction Twists Filler Left Hand 4.8 twist/ft Fibrous Polypropylene

Electrical Characteristics

Nominal Conductor DCR Nominal Outer Shield DCR 24 Ohm/1000ft 3.4 Ohm/1000ft Capacitance Nom. Capacitance Conductor to Conductor Nom. Capacitance Conductor to Other Conductor to Shield

12.8 pF/ft 23 pF/ft Impedance Nominal Characteristic Impedance

120 Ohm

High Frequency (Nominal/Typical) Nom. Insertion Loss 0.6 dB/100ft Delay Nominal Delay Nominal Velocity of Propagation (VP) [%] 1.6 ns/ft 66 % Current Element Max. Recommended Current [A] 10C Temperature Rise Per conductor @ 25°C Ambient (10C temperature rise): 2.1 A Voltage UL Description UL Voltage Rating Type CM 300 V RMS (UL type CM) AWM 2919 30 V RMS (UL AWM 2919) Electrical Characteristics Notes: Attenuation @ 1 MHz: .6 dB/100 ft nominal Temperature Range UL Temp Rating: 80°C (UL AWM Style 2919) Operating Temp Range: -30°C To +80°C Mechanical Characteristics Bulk Cable Weight: 36 lbs/1000ft Max Recommended Pulling Tension: 72.3 lbs Min Bend Radius/Minor Axis: 2.5 in Standards NEC Articles: 800 NEC/(UL) Specification: CM CEC/C(UL) Specification: CM UL AWM Style: 2919 (30 V 80°C) CPR Euroclass: Eca Applicable Environmental and Other Programs EU Directive 2000/53/EC (ELV): Yes EU Directive 2003/96/EC (BFR): Yes EU Directive 2011/65/EU (ROHS II): Yes EU Directive 2012/19/EU (WEEE): Yes EU Directive 2015/863/EU: Yes EU Directive Compliance: EU Directive 2003/11/EC (BFR) EU CE Mark: Yes EU RoHS Compliance Date (yyyy-mm-dd): 2004-01-01 CA Prop 65 (CJ for Wire & Cable): Yes MII Order #39 (China RoHS): Yes Suitability Suitability - Hazardous Locations: Yes Suitability - Indoor: Yes Flammability, LS0H, Toxicity Testing UL Flammability: UL1685 (UL Loading) CSA Flammability: FT1 ISO/IEC Flammability: IEC 60332-1-2

UL voltage rating: 300 V RMS (CM) Plenum/Non-Plenum Plenum (Y/N): No Plenum Number: 82841, 89841 Part Number Variants Item # Color UPC Length Footnote

9841.0030 Chrome 30 m

9841.011000 Chrome 1,000 m

9841.01152 Chrome 152 m

9841.011525 Chrome 1,525 m

9841.012000 Chrome 2,000 m

9841.01305 Chrome 305 m

9841.019999 Chrome 151 m

9841 060100 Chrome 612825259442 100 ft 9841 0601000 Chrome 612825259459 1,000 ft C 9841 06010000 Chrome 612825259466 10,000 ft C 9841 060500 Chrome 612825259473 500 ft C 9841 0605000 Chrome 612825259480 5,000 ft 9841.K1305 Chrome 305 m

9841.031000 Violet 1,000 m

9841.03305 Violet 305 m

9841.02305 Yellow 305 m

Footnote: C - CRATE REEL PUT-UP. History Update and Revision: Revision Number: 0.311 Revision Date: 08-22-2019 © 2019 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product.