9800 BK | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 5

Technical content

Features

n 0 to 300 V, low distortion AC power source with models delivering a maximum of

1500 VA, 12 Arms / 36 Apeak

n Output frequency adjustable from

45 Hz to 500 Hz

n Select 150 V / 300 V autoranging or 300 V range operation for continuous sweep from 0 to 300 V n Displays Vrms, Irms, Ipeak, frequency, PF, apparent power, true power, and elapsed output time n Adjustable phase angle control n Programmable voltage and frequency limit settings n Built-in PLD and dimmer simulation n Voltage and frequency sweep mode n List mode: 10 user-defined programs with up to 100 programmable steps each n BNC I/O for external triggering, output status indication/control, and synchronization n Save and recall up to 100 instrument settings n Standard USB (USBTMC-compliant), RS232, LAN and GPIB* interfaces n OVP/OCP/OPP/OTP protection modes and key lock function n Pre-compliance testing for voltage dips and frequency simulations according to IEC61000-4-11 / 4-14 / 4-28 n LabVIEW driver and softpanel for remote control available * 9803 and 9805 only

Programmable AC Power Sources

9800 Series

www.bkprecision.com Front panel Rear panel Model 9801 Models 9803 & 9805 Models 9803 & 9805 Model 9801 Bright VFD display shows Vrms, Irms, Ipeak, frequency, power factor (PF), apparent power, true power and elapsed output time. BNC I/O for triggering, output status / control, and synchronization Numeric keypad for direct entry of AC output waveform parameters Function keys LAN interface RS232 interface USB interface Cooling fan AC line input AC line input 110/220 V selector BNC I/O trigger AC output terminal System BUS (not used) RS232 interface LAN interface USB interface GPIB interface Cooling fans AC output terminal Cursor keys AC output terminal Encoder knob for quick analog style control LAN interface

Programmable AC Power Sources www.bkprecision.com Flexible operation List mode List mode supports the generation of more complex sequences with varying times, amplitudes, and frequencies. Up to 100 steps in 10 groups can be saved and executed. This allows the user to build a wide range of waveforms in a sequence to simulate grid faults and disturbances. The programmed list can be triggered from the front panel or via BNC connector on the rear. List Mode Steps PLD Waveforms Power line disturbance (PLD) simulator The PLD simulator is an extended feature of list mode that provides the user with more control over the disturbance insertion into the waveform. This can be useful for evaluating a product’s immunity performance. For instance, a user could produce common waveform disturbances like surge, sag, spikes, and dropouts at user-defined locations on the waveform.

Programmable AC Power Sources www.bkprecision.com Sweep mode The sweep function is ideal for testing the efficiency of switching power supplies or capturing the maximum operating power requirements of the device under test. User-defined voltage and frequency sweeps can be created independently or combined. Up to 10 sweep profiles can be stored and recalled. Dimmer simulation The dimmer feature can be used for many test applications such as motor control and lighting. By controlling the phase cut-off of the AC sine wave’s leading or trailing edge, the dimmer simulation varies the RMS voltage supplied to the load under test. The phase cut-off can be adjusted for leading or trailing edge dimming between 0 to 180 degrees. Application software PC software is provided for front panel emulation, generating and executing list, PLD, and sweep profiles, or logging measurement data without the need to write source code. Trailing Edge Dimmer at 60°Leading Edge Dimmer at 90° Supports NI Data Dashboard for LabVIEW Voltage Sweep Frequency Sweep Voltage plus Frequency Sweep

Programmable AC Power Sources www.bkprecision.comv102319 Specifications Model 9801 9803 9805 AC Input Phase Single Voltage 110 / 220 VAC ± 10% Frequency 47 to 63 Hz Max. Current 8 A max. 15 A max. 30 A max. Power Factor 0.5 (typical) 0.7 (typical) 0.7 (typical) AC Output Max. Power 300 VA 750 VA 1500 VA Max. Current (rms) 0 to 150 V 3.0 A 6 A 12 A 0 to 300 V 1.5 A 3 A 6 A Max. Current (peak) 0 to 150 V 9 A 18 A 36 A 0 to 300 V 4.5 A 9 A 18 A Crest Factor 3 Phase Single Total Harmonic Distortion (THD) ≤0.5% at 45 to 500 Hz (Resistive load) Line Regulation 0.1% max for a ±10% line change Load Regulation ≤0.5% FS (Resistive load) Response Time <100 µs Programming Voltage (rms) Range 0 to 300 V, 150 V / 300 V (Auto) Resolution 0.1 V Accuracy ±(0.2% + 0.6 V) Frequency Range 45 to 500 Hz Resolution 0.1 Hz at 45 to 99.9 Hz

1 Hz at 100 to 500 Hz

Accuracy ±0.1 Hz (100 Hz) ±1 Hz (100 to 500 Hz) Phase Angle Range 0 to 360° Resolution 0.1° Accuracy ±1° (45 to 65 Hz) Measurements Voltage (rms) Range 0 to 300 V Resolution 0.1 V Accuracy ±(0.2% + 0.6 V) Current (rms) Range* Low: 120.0 mA / Mid: 1.200 A / High: 3.00 A Low: 120.0 mA / Mid: 1.200 A / High: 6.00 A Low: 120.0 mA / Mid: 1.200 A / High: 12.00 A Resolution Low: 0.1 mA / Mid:1 mA / High: 10 mA Accuracy Low: ±(0.2% + 0.4 mA) / Mid: ±(0.2% + 4 mA) / High: ±(0.2% + 20 mA) Current (peak) Range 0 to 9 A 0 to 18 A 0 to 36 A Resolution 0.01 A Accuracy ±(1% + 120 mA) True Power (watts) Resolution Low: 0.01 W / Mid:0.1 W / High: 1 W Accuracy (47 to 65 Hz) High: ±(0.2% + 2 W) Frequency Range 45 to 500 Hz Resolution ±0.1 Hz (45 to 99.9 Hz), ±1 Hz (100 to 500 Hz) Accuracy ±0.1 Hz Power Factor Range 0.000 to 1.000 Resolution 0.001 Apparent Power (VA) Resolution Low: 0.01 VA / Mid:0.1 VA / High: 1 VA Accuracy Voltage (rms) x Current (rms) Temperature Coefficient (typical) ±0.04% per ºC General Memory 10 Locations External BNC I/O Trigger input, sync output, output status, output indicator / control Interface LAN, USB, RS232 LAN, USB, RS232, & GPIB Operating Temperature 32 °F to 104 °F (0 °C to 40 °C) 20 - 80% R.H. Storage Temperature -4 °F to 158 °F (-20 °C to 70 °C) ≤ 85% R.H. Environmental conditions For indoor use only, max humidity 80%, no condensation Dimensions (W x H x D) 8.45” x 3.47” x 17.83” (214.5 x 88.2 x 453.5 mm) (439 x 131.4 x 535.7 mm) Weight 20.94 lb (9.5 kg) 88.2 lb (40 kg) 115 lb (52.16 kg) Warranty 2 Years Standard Accessories AC Power cord (9801 only), unterminated power cord with input connector (9803 & 9805 only), rackmount ears & handles (9803 & 9805 only), instruction manual, test report & certificate of calibration Optional Accessories IT-E151 rack mount kit (9801 only) Note: All specifications apply to the unit after a temperature stabilization time of 15 minutes over an ambient temperature range of 23 °C ± 5 °C. * The current range switches from low to mid range or mid to high range when Ipeak > 300% of the present range. When Ipeak is <80 % of the high range, the current range switches from high to mid range. When Ipeak is <20 % of the mid range, the current range switches from mid to low range. 9803 & 9805 Standard Accessories Unterminated power cord Rackmount ears with handles