Product: 9583 Electronic, 2 C #12 Sol BC, PVC Ins, OS, Red PVC Jkt, FPLR Product Description Electronic, 2 Conductor 12AWG (Solid) Bare Copper, PVC Insulation, Overall Beldfoil® Shield, Red PVC Outer Jacket, FPLR Technical Specifications Product Overview Suitable Applications: fire alarms; indoor applications; low voltage analog signals (4-20ma, 0-10v, ...); low voltage control (24v, …) Construction Details Conductor Element Number of Element Size Stranding Material Pair(s) 1 12 AWG Solid BC - Bare Copper Insulation Element Material Nom. Thickness Nom. Insulation Diameter Color Code Pair(s) PVC - Polyvinyl Chloride 0.023 in (0.58 mm) 0.127 in (3.23 mm) Black and Red Outer Shield Shield Type Material Coverage Drainwire Type Tape Bi-Laminate (Alum+Poly) 100% 16 AWG (19x29) TC Outer Jacket Material Nom. Thickness Nom. Diameter PVC - Polyvinyl Chloride 0.042 in (1.1 mm) 0.343 in Overall Cable Diameter (Nominal): 0.343 in

Electrical Characteristics

Element Nom. Conductor DCR Nom. Capacitance Cond-to-Cond Nom. Capacitance Cond-to-Other (Conds + Shield) Max. Current Pair(s) 1.6 Ohm/1000ft 86 pF/ft (280 pF/m) 160 pF/ft (520 pF/m) 21 Amps per Conductor at 25ºC Voltage UL Voltage Rating 300 V Mechanical Characteristics Temperature UL Temperature Operating 105°C -20°C To +75°C Bend Radius Stationary Min. Installation Min. 5.14 in (131 mm) 5.14 in

Max. Pull Tension: 197 lbs (89.4 kg) Bulk Cable Weight: 80 lbs/1000ft Standards and Compliance Environmental Suitability: Indoor, Outdoor, Sunlight Resistance Flammability / Reaction to Fire: UL1666 Riser, FT4 NEC / UL Compliance: Article 760, FPLR CEC / C(UL) Compliance: FAS105 European Directive Compliance: EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE) APAC Compliance: China RoHS II (GB/T 26572-2011) Other Standard Compliance(s): California State Fire Marshall Product Notes Notes: This cable passes the UL 70, 000 BTU Flame Test (comparable to the IEEE 383 Flame Test) and are listed by the California State Fire Marshall. Component Recognized UL 2464, 300V 80C. History Update and Revision: Revision Number: 0.401 Revision Date: 05-05-2023 Part Numbers Variants Item # Color UPC 9583 0021000 Red 612825256250 © 2023 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product.