CDE Cornell Dubilier • 1605 E. Rodney French Blvd. • New Bedford, MA 02744 • Phone: (508)996-8561 • Fax: (508)996-3830 Type 944U Polypropylene, DC Link Capacitors High Current, Low Profi le for Inverter Applications Type 944U is specifi cally designed for use in high power DC fi ltering applications. The low inductance internal construction utilizes low loss metallized polypropylene for high ripple current capability. Male or female terminal options off er design fl exibility in a rugged UL 94VO rated fl ame retardant plastic case and resin fi ll. High current ratings and robust mounting fl anges make the 944U suited for inverter applications in electric vehicle power inverters, wind power inverters and motor drives. Highlights - Low Inductance - Low Profi le - Low ESR - High Ripple Current - High Voltage Ratings Specifi cations Capacitance Range 33 to 220 µF Capacitance Tolerance ±10% standard Rated Voltage 800 to 1400 Vdc Operating Temperature Range -40 ºC to 85 ºC Maximum rms Current 74A @ 55 ºC Maximum rms Voltage 230 Vac Test Voltage between Terminal @ 25ºC 150% rated DC voltage for 10 s Test Voltage between Terminals & Case @ 25ºC 4 kVac @ 50/60 Hz for 60 s Life Test 5000 h @ 85 ºC, rated voltage RoHS Compliant H ±0.5 mm 5 mm 6 ±0.5 mm 20 ±0.5 mm 84.5 mm 45 ±1 mm 101 mm 71.4 mm 15 mm M8 x 1.25
8.5 Nm Max Torque
M5 x 4.0 mm
2.5 Nm Max Torque
5.5 mm
3 Nm Mounting Torque
90° Threaded Insert Threaded Stud Construction Details Case Material Plastic UL94V-0 Resin Material Dry Resin UL94V-0 Terminal Material Tin Plated Brass UL Recognized E128034 construction only - unprotected Film
CDE Cornell Dubilier • 1605 E. Rodney French Blvd. • New Bedford, MA 02744 • Phone: (508)996-8561 • Fax: (508)996-3830 Ratings Typical Performance Curves 944U 101 K 801 A A M Type Capacitance Tolerance Voltage Diameter D (mm) Height H (mm) Terminal 944U 101 = 100 µF K = ±10% 801 = 800 Vdc A = 84.5 A = 40 M = M8 Thd Stud 700 = 70 µF 102 = 1000 Vdc B = 51 I = M5 Thd Insert 470 = 47 µF 122 = 1200 Vdc C = 64 142 = 1400 Vdc Catalog Part Number Cap (µF) Rated Voltage (Vdc) H Height mm Typical ESR 10kHz (mΩ) Typical ESL (nH) Max Irms 55ºC (A) Thermal Resistance Θcc (ºC/W) Θca (ºC/W) 944U101K801AA* 100 800 40 0.5 20 74 2.8 5.2 944U161K801AB* 160 800 51 0.8 30 73 3.0 4.5 944U221K801AC* 220 800 64 1.0 40 72 3.1 4.0 944U660K102AA* 66 1000 40 0.6 20 70 2.8 5.2 944U101K102AB* 100 1000 51 0.8 30 68 3.0 4.5 944U141K102AC* 140 1000 64 1.0 40 65 3.1 4.0 944U470K122AA* 47 1200 40 0.7 20 67 2.8 5.2 944U700K122AB* 70 1200 51 1.0 30 65 3.0 4.5 944U101K122AC* 100 1200 64 1.3 40 64 3.1 4.0 944U330K142AA* 33 1400 40 0.8 20 64 2.8 5.2 944U520K142AB* 52 1400 51 1.1 30 60 3.0 4.5 944U700K142AC* 70 1400 64 1.4 40 59 3.1 4.0 * M = M8 Stud I = M5 Insert Part Numbering System 1.5 2.5 3.5 100 1000 10000 100000 ESR (mΩ) Frequency (Hz) 160 µF 800 Vdc ESR vs Frequency and Temperature 85 ºC 65 ºC 45 ºC 25 ºC 0 ºC -20 ºC -40 ºC 0.00 10.00 20.00 30.00 40.00 50.00 60.00 70.00 80.00 90.00 10 100 1000 10000 100000 Rated Ripple Current (A) Frequency (Hz) 160 µF 800 Vdc Rated Ripple Current, Still Air, 5 kh Life 45 ºC 55 ºC 65 ºC 75 ºC 85 ºC Type 944U Polypropylene, DC Link Capacitors High Current, Low Profile for Inverter Applications NOTE: Other ratings, sizes and performance specifications are available. Contact us. Film
CDE Cornell Dubilier • 1605 E. Rodney French Blvd. • New Bedford, MA 02744 • Phone: (508)996-8561 • Fax: (508)996-3830 Expected Lifetime Predictions Expected Lifetime vs Hot Spot Temperature and Applied DC Voltage 0.8 0.9 1.1 1.2 1.3 1.4 1.5 1.6 1000 10000 100000 1000000 Expected Lifetime (h) Va / Vr 50ºC 60ºC 70ºC 85ºC Type 944U Polypropylene, DC Link Capacitors High Current, Low Profile for Inverter Applications C (µF) ESR (mΩ) f (kHz) I (A rms) TA (°C) TC (°C) Θ (°C/W) Θ CA (°C/W) ΘCC (°C/W) v (m/s) V A (VDC) VR (VDC) Determine ESR at Operating Frequency Use the 10 kHz ESR from the ratings tables. For operation below 10 kHz, the ESR will need to be adjusted using the following equation: ESR - 31.83/(10C) + 31.83/(fC). Determine Thermal Resistance at Operating Frequency and Air Flow Compute Θ = Θ CC + ΘCA. In the ratings tables, ΘCA is for still air. For v = 0 to 5 m/s, Determine Expected Lifetime Look up Expected Lifetime on the graph using V A/VR and TC = TA + I2 (ESR/1000) Θ The maximum allowed temperature rise is 40 °C and the maximum allowed core temperature is 95 °C. Capacitance: Equivalent Series Resistance: Frequency: Ripple Current: Ambient Temperature: Core Temperature: Total Thermal Resistance: Thermal Resistance case-to-ambient: Thermal Resistance core-to-case: Airflow Speed: Applied Voltage: Rated Voltage: Film
Notice and Disclaimer: All product drawings, descriptions, specifications, statements, information and data (collectively, the “Information”) in this datasheet or other publication are subject to change. The customer is responsible for checking, confirming and verifying the extent to which the Information con- tained in this datasheet or other publication is applicable to an order at the time the order is placed. All Information given herein is believed to be accurate and reliable, but it is presented without any guaran- tee, warranty, representation or responsibility of any kind, expressed or implied. Statements of suitability for certain applications are based on the knowledge that the Cornell Dubilier company providing such statements (“Cornell Dubilier”) has of operating conditions that such Cornell Dubilier company regards as typical for such applications, but are not intended to constitute any guarantee, warranty or representa- tion regarding any such matter – and Cornell Dubilier specifically and expressly disclaims any guarantee, warranty or representation concerning the suitability for a specific customer application, use, storage, transportation, or operating environment. The Information is intended for use only by customers who have the requisite experience and capability to determine the correct products for their application. Any technical advice inferred from this Information or otherwise provided by Cornell Dubilier with reference to the use of any Cornell Dubilier products is given gratis (unless otherwise specified by Cornell Dubilier), and Cornell Dubilier assumes no obligation or liability for the advice given or results obtained. Although Cornell Dubilier strives to apply the most stringent quality and safety standards regarding the design and manufacturing of its products, in light of the current state of the art, isolated component failures may still occur. Accordingly, customer applications which require a high degree of reliability or safety should employ suitable designs or other safeguards (such as installation of protective circuitry or redundancies or other appropriate protective measures) in order to ensure that the failure of an electrical component does not result in a risk of personal injury or property damage. Although all product-related warnings, cautions and notes must be observed, the customer should not assume that all safety measures are indi- cated in such warnings, cautions and notes, or that other safety measures may not be required. Film