9400 MACOM | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 2
Technical content
Features
- Single-pole relay used extensively in HVAC applications.
- Multi-positional mounting without affecting operation.
- Convenient 0.250” (6.35 mm) quick connect terminals. Users should thoroughly review the technical data before selecting a product part number. It is recommended that users also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. Contact Data @ 25°C Arrangements: 1 Form X (SPST -NO-DM), 1 Form Y (SPST -NC-DB),
1 Form Z (SPDT -DM-DB) & 1 Form Z (SPDT -DM-DB)
jumpered to wire as 1 Form C (SPDT). Materials: Silver Alloy and Fine Silver. Maximum Ratings: Silver Alloy (Power) Contacts All Forms: 12 FLA, 60 LRA @ 125VAC; 18A @ 125VAC, resistive;
8 FLA, 48 LRA @ 240/277VAC;
18A @ 240/277VAC, resistive. 1 Form X only: 25A @ 240/277VAC, resistive. Fine Silver (Pilot) Contacts All Forms: 3A, 277VAC; 125VA @ 125VAC; 250VA @ 250VAC; 277VA @ 277VAC; Expected Life: 1 million ops., mechanical. 250,000 ops., at rated resistive load. 100,000 ops., at rated inductive load. Initial Dielectric Strength Initial Breakdown Voltage: 1 ,554 VAC between live parts and exposed non-current carrying metal parts. Coil Data @ 25°C Voltage: 12 & 24 VDC; 6-277 VAC, 50/60 Hz. Max. Sealed Power: 4 VA (AC coils.); 3 W (DC coils). Nominal Inrush Power: 5 VA (AC coils.); 3 W (DC coils). Insulation Class: UL Class B (130°C). Duty Cycle: Continuous. Environmental Data T emperature Range:Storage and Operating: -40°C – +65°C. Mechanical Data T ermination:0.250” (6.35 mm) quick connects, standard. Consult factory for availability of optional 0.187” (4.75 mm) quick connects. Weight: 2.88 oz. (82 g) approximately 9400 series Power Relay 1-pole, 8-12 FLA AC or DC Coil File E75492 Coil Temperature Rise (C) % Of Nominal Coil Voltage 140 120 100 0 80 100 120 130 Operate Data @ 25°C Must Operate Voltage: Approximately 85% of AC nominal coil voltage. Approximately 75% of DC nominal coil voltage. Coil T emperature Rise Above Ambient
reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. Catalog 1308242 Issued 3-03 Specifications and availability subject to change. www.tycoelectronics.com Technical support: Refer to inside back cover. 9400-03Q1999 9400-03T1999 9400-03U1999 9400-04Q1999 9400-04T1999 9400-04U1999 Standard part numbers listed below are more likely to be available from stock.
Ordering Information
T ypical Part No. B 9400 -0 3 Q 1 999 1. Series: 9400 = 1- pole, 8-12 FLA relay 2.Mounting Bracket: 1 = Standard I Bracket with mounting holes on 2.625” (66.67mm) centers 4 = Standard T Bracket with mounting holes on 1 .563” (39.70mm) centers 0 = Special I Bracket with mounting holes on 2.156” (54.76mm) centers 3. Pole Configuration: 1 = 1 Form X (SPST -NO-DM) 3 = 1 Form Z (SPDT -DM/DB) 2 = 1 Form Y (SPST -NC-DB) 4 = 1 Form Z (SPDT -DM/DB) jumpered to wire as 1 Form C. 4. Coil Voltage (50/60 Hz.): B = 12VDC Y = 6VAC P = 100VAC S = 200VAC V = 277VAC C = 24VDC Q = 24VAC T = 120VAC U = 208/240VAC QS = 24VAC, low VA 5. Contact T ype: 1 = Silver alloy power contacts 2 = Fine silver pilot contacts 6. Customer ID Suffix: 999 = Standard Model 000-998 = Factory assigned customer ID Outline Dimensions Contact Configurations
1 Form X
1 Form Y 1 Form Z Jumpered
1 .500 MAX. (38.1) 1 .265 MAX. (32.13) .625 (15.9) 1 .265 (32.13) 2.625 (66.68) 3.00 (76.2) .190 DIA (4.826) 1 .842 (46.79) 1 .842 (46.79).150 DIA (3.81) 2.156 (54.76) 2.67 (67 .8) 1 .265 (32.13) .500 (12.7) 1 .265 (32.13) .150 DIA (3.81) 1 .842 (46.79) .922 (23.42) 1 .563 (39.7) 1 .813 (46.05) .375 (9.52) 9400 Series Standard T Bracket (Code 4) Standard I Bracket (Code 1) Special I Bracket (Code 0)