0 … 5 N to 0 … 700 kN 9323_000-704e-10.22 © 2008 ... 2022 Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland ducts are protected by various intellectual property rights. For more details visit www.kistler.com This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded. Page 1/10 Type 9323A … 9393A, Type 9383AU0109 Type 9393AU0109 The sensors of the Press Force series are ideal for measuring both dynamic and quasistatic forces. The factory preloading and adaptability of these practical designs ensure readiness for immediate use. They come in five different sizes which are divided in seven measuring ranges.

  • Each individual sensor offers an extremely wide measuring range
  • Calibration certificate for 3 measuring ranges: 100 %, 10 %, 1 % and 0,1 % (Type 9323AAA only)
  • SCS calibration optional
  • Simple mechanical adaptation with flanges on both ends
  • Easily mounted in connecting rods or press plungers
  • Factor of safety against overload of up to 100 when using lowest ranges

Description

These press force sensors are based on the piezoelectric meas- uring principle. The force acting on the quartz element gener- ates at the output of the sensor a proportional electric charge, which is converted by the series-connected measuring ampli- fier (such as ICAM Type 5073A...) into a process signal suitable for evaluation (typically 0 ...10 V). Depending on the utilized type of sensor, tension forces of up to 16 % of the compres- sion force range can also be measured. Although uncalibrated, these ranges are often used for detecting tool withdrawal forc- es, for example after press-fit processes.

Applications

The flange connections at both ends allow flexible mechani- cal adaptation of the sensor to suit the particular machine environment. The included centering rings also facilitate axial adjustment. The rotationally symmetrical shape of the press force sensor makes it ideal for mounting in or on the end of connecting rods or press plungers. The piezoelectric element's special characteristic of ap- proximately constant measuring accuracy over a substantial range allows the same press force sensor to be used for a wide spectrum of forces. The feasibility of switching measur - ing range when using suitable amplifiers (such as the ICAM Type 5073A...) bolsters this advantage while accommodating the general trend towards production and measuring stations handling a greater variety of parts. However, the wide-range measuring chain also offers critical advantages in laboratory applications, where frequent changes of sensor are the order of the day. And the extremely high degree of overload protec- tion obviates involved protective measures when using the lowest measuring ranges. Fig. 1: Calibrating element with force distributing cap, flange and cable protector Fz

Press Force Sensor – 0 … 5 N to 0 … 700 kN, Type 9323A … 9393A, 9383AU0109, 9393AU0109 9323_000-704e-10.22 © 2008 ... 2022 Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland ducts are protected by various intellectual property rights. For more details visit www.kistler.com This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded. Page 2/10 Technical data Press Force Sensor Type 9323AAA 9323AA 9323A 9333A 9343A 9363A 9383A 9393A Overload Fz kN 5.5 12 24 60 84 144 360 840 Measuring ranges, calibrated Fz 0.1 % kN 0 … 0.005 Max. tension force kN 0 … –1 0 … –1 0 … –2 0 … –5 0 … –10 0 … –20 0 … –50 0 ... – 140 Linearity incl. Hysteresis 1) %FSO ≤±0.5 2) Preload force Fv kN 8.5 8.5 8.5 15 25 80 250 450 Torque max. (Fx,y = 0, Fz = 0), Mz N·m 5 5 5 14 31 145 783 1 980 Bending moment max. Mx,y Fz = 100% N·m 0.9 0.9 0.9 10 10 232 972 1 100 Fz = 0% N·m 14 23 23 65 135 638 3.407 9 940 Shear force max. 3) Crosstalk (typical) Natural frequency, fn (Fz) kHz >70 4) >74.5 >72 >55 >47 >35 >17 >11.3 Operating temperature °C –40 … 80 –40 ... 120 Temperature coefficient of sensitivity, Fz %/°C 0.02 0.05 –0.02 Insulation resistance at 23°C W ≥1·1013 ≥5·1013 ≥1013 Capacity C pF ≈202 ≈68 ≈29 ≈55 ≈65 ≈150 ≈790 ≈890 Connector KIAG 10-32 neg. Protection class EN60529 with connected cable IP 65 with cable Type 1983AD… and welded sensor IP 67 Case material DIN 1.4542 Weight g 48 50 47 137 240 800 6.490 1.8663 Tightening torque. max., MA M3 N·m 1 1 1 M4 N·m 2 M5 N·m 4 M8 N·m 21 M12 N·m 75 M16 N·m 150 1) Refering to FSO of the calibrated (!) measuring range 2) For sub-range 0.1% determined only for ascending curve, without hystheresis 3) Corresponds to lateral force at the flange 4) Calculated value

Press Force Sensor – 0 … 5 N to 0 … 700 kN, Type 9323A … 9393A, 9383AU0109, 9393AU0109 9323_000-704e-10.22 © 2008 ... 2022 Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland ducts are protected by various intellectual property rights. For more details visit www.kistler.com This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded. Page 3/10 General mounting instructions

  • The flange bearing surfaces that transmit the force to the sensor must be kept flat and free from dirt and grease
  • The centering seats on both ends of the sensor allow ve- ry accurate coaxial mounting using the supplied centering rings.
  • The sensor can be mounted using the central female thread or tapped holes of the pitch circle.
  • Do not exceed the bending moments, torques and shear force specified in the table.
  • Whenever possible the force should be transferred axially rather than laterally.
  • See pages 4 and 5 for other mounting options. Customized measuring range Types 9383A and 9393A can also be customized prestressed. The measuring range can thus be designed for a specific ten- sion-/pressure range. The type designation for the customer specific sensors will be extended with U0109. Technical data Press Force Sensor Type 9383AU0109 9393AU0109 Compression force: Measuring range Fz, max kN –50 … 500 a) –100 … 950 b) Overload Fz, max. kN –55/550 –110/1 045 Calibrated Range Fz kN customized customized Linearity incl. Hysteresis %FSO ≤±1 ≤±1 a) Minimal pretension: Fv1 = 100 kN at max. compression force of Fz = 500 kN b) Minimal pretension: Fv1 = 200 kN at max. compression force of Fz = 950 kN

Press Force Sensor – 0 … 5 N to 0 … 700 kN, Type 9323A … 9393A, 9383AU0109, 9393AU0109 9323_000-704e-10.22 © 2008 ... 2022 Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland ducts are protected by various intellectual property rights. For more details visit www.kistler.com This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded. Page 4/10 Dimensions Type 9323A/AA/AAA … 9383A Type 9323A/9333A/9343A/9363A Type 9383A Connector protector such as O-ring Type 1100A59 Accessories such as cable Type 1631C Connector protector such as O-ring Type 1100A59 Accessories such as cable Type 1631C

Press Force Sensor – 0 … 5 N to 0 … 700 kN, Type 9323A … 9393A, 9383AU0109, 9393AU0109 9323_000-704e-10.22 © 2008 ... 2022 Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland ducts are protected by various intellectual property rights. For more details visit www.kistler.com This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded. Page 5/10 Dimensions Type 9393A Connector protector such as O-ring Type 1100A59 Accessories such as cable Type 1631C Dimensions in mm Type D D1 D2 D3*  H A A1 B C E F G K P T S x y * Free passage with mounted centering rings

Press Force Sensor – 0 … 5 N to 0 … 700 kN, Type 9323A … 9393A, 9383AU0109, 9393AU0109 9323_000-704e-10.22 © 2008 ... 2022 Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland ducts are protected by various intellectual property rights. For more details visit www.kistler.com This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded. Page 6/10 A: Direct mounting using integral mounting screw and threa- ded bushing B: Direct mounting using integral fine thread Centering rings (included accessories) Standard adapter flange Customized tool adapter Allen screw (included accessory) Threaded bushing (included accessory) Integral fine thread Standard adapter flange Customized tool adapter C: Mounting using straight shank adapter D: Mounting using threaded adapter Customized tool adapter with clamping screw Straight shank adapter (pos.) Straight shank adapter (neg.) with clamping screw Adapter with female thread Type 9584A... (optional accessory) E: Mounting using adapter disk/flange F: Direct mounting using integral flange Adapter disk for in-line mounting in connecting rod Standard adapter flange Adapter with male thread Type 9586A... (optional accessory)

Press Force Sensor – 0 … 5 N to 0 … 700 kN, Type 9323A … 9393A, 9383AU0109, 9393AU0109 9323_000-704e-10.22 © 2008 ... 2022 Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland ducts are protected by various intellectual property rights. For more details visit www.kistler.com This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded. Page 7/10 G: Adapter for deep drawing tool with central ejection tool H: Adapter for punching tool with central ejection bore ToolDeep drawing tool Ejection tool Punching toolTool Ejection hole Customized bed mounting (countersunk) Customized bed mounting (countersunk) I: Adapter riveting tool J: Calibrating element with force distributing cap and flange As reference sensor under a press Riveting toolTool holder Force distributing cap Type 9582A… Flange Type 9580A… Customized bed mounting Threaded bushing Hexagon socket screw Centering rings (included accessories) Allen screw (included accessory) Threaded bushing (included accessory) Drawings of mechanical accessories (scope of delivery) Sensor Art. No D1 d1 d5 H1 P T T1 S Type 9323A/AA/ 3.315.076 – – 2,2 4,8 M5x0,5 1 – 1 AAA 9333A 3.315.053 6,5 1,1 4,3 4,5 M9x0,5 – 3 – 9343A 3.315.054 9,1 1,3 6,4 7 M13x1 – 3,5 – 9363A 3.315.055 14,5 1,6 10,5 10,5 M20x1,5 – 5 – 9383A 3.315.087 21 2,5 16,5 24,5 S28x2-8e – 5 – Sensor Art. No D1 Type 9323A/AA/ 6.120.235 M2x12 AAA 9333A 6.120.102 M4x12 9343A 6.120.122 M6x18 9363A 6.120.066 M10x25 9383A 55075248 M16x50 9393A 6.120.136 M30x60

Press Force Sensor – 0 … 5 N to 0 … 700 kN, Type 9323A … 9393A, 9383AU0109, 9393AU0109 9323_000-704e-10.22 © 2008 ... 2022 Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland ducts are protected by various intellectual property rights. For more details visit www.kistler.com This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded. Page 8/10 Flange Sensor Flange D1 d d1 d2 d3 d4 d5 d6 H2 T1 N Type Type 9323A/AA/ 9580A9 14 40 30 6 4,5 3,2 4,5 5,6 8 2 3 AAA 9333A 9580A0 21 62 50 10 5,5 4,3 8,5 7,5 11 2 5 9343A 9580A1 26 70 55 14 6,6 5,3 12 9 13 2 6 9363A 9580A2 40 100 78 21 13,5 8,4 18 14 22 2 9 9383A 9580A4 70 180 135 30 17 13 25 20 30 2,5 13 9393A 9580A6 105 220 180 52 21 17 31 26 48 2,5 17 Force distributing cap Sensor Force Distr. D1 D5 d2 d4 d6 H3 T1 N R1 Type Cap Type 9323A/AA/ 9582A9 14 20 6 3,2 5,6 8,5 2 3,5 200 AAA 9333A 9582A0 21 30 10 4,3 7,5 11 2 5 250 9343A 9582A1 26 36,5 14 5,3 9 13 2 6 300 9363A 9582A2 40 56 21 8,4 14 22 2 9 350 9383A 9582A4 70 100 30 13 20 50 2,5 13,5 550 9393A 9582A6 105 145 52 17 26 80 2,5 19 850 Centering ring Sensor Type Art. No. D2 D3* 9323A/AA 3.420.196 6 4 AAA 9333A 3.420.179 10 8 9343A 3.420.180 14 11 9363A 3.420.181 21 17 9383A 3.420.197 30 23,5 9393A 3.420.280 52 45,5 Drawings of mechanical accessories (optional) * Free passage with mounted centering rings Type 9580A9/A0/A1/A2 Type 9580A4 Type 9580A6 Type 9582A9/A0/A1/A2 Type 9582A4 Type 9582A6

Press Force Sensor – 0 … 5 N to 0 … 700 kN, Type 9323A … 9393A, 9383AU0109, 9393AU0109 9323_000-704e-10.22 © 2008 ... 2022 Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland ducts are protected by various intellectual property rights. For more details visit www.kistler.com This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded. Page 9/10 Adapter with male thread Sensor Adapter D1 D5 d2 d4 d6 H N P L T Type Type 9323A/AA/ 9586A9 14 20 6 3,2 5,6 8 3 M4 5 2 AAA 9333A 9586A0 21 30 10 4,3 7,5 11 5 M8 9 2 9343A 9586A1 26 36,5 14 5,3 9 14 7 M12 12 2 9363A 9586A2 40 56 21 8,4 14 21 9 M18 19 2 9383A 9586A4 70 100 30 13 20 30 13,5 M27 26 2,5 9393A 9586A6 105 150 52 17 26 48 17 M42 43 2,5 Adapter with female thread Sensor Adapter D1 D5 d2 d4 d6 H N P T Type Type 9323A/AA/ 9584A9 14 20 6 3,2 5,6 8 3 M4 2 AAA 9333A 9584A0 21 30 10 4,3 7,5 11 5 M8 2 9343A 9584A1 26 36,5 14 5,3 9 14 7 M12 2 9363A 9584A2 40 56 21 8,4 14 21 9 M18 2 9383A 9584A4 70 100 30 13 20 30 13,5 M27 2,5 9393A 9584A6 105 150 52 17 26 48 17 M42 2,5 Type 9584A9/A0/A1/A2 Type 9584A4 Type 9584A6 Type 9586A9/A0/A1/A2 Type 9586A4 Type 9586A6

Press Force Sensor – 0 … 5 N to 0 … 700 kN, Type 9323A … 9393A, 9383AU0109, 9393AU0109 9323_000-704e-10.22 © 2008 ... 2022 Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland ducts are protected by various intellectual property rights. For more details visit www.kistler.com This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded. Page 10/10 Sensor Connecting cable Charge amplifier maXYmos Type 9323A ... 9393A Type 1631C… Type 5073A111 2) Type 5867B… 2) Ordering code Type/Art. No. Included accessories Press Force Sensor Fz 0 ... 5 kN 9323AAA

  • Threaded bushing 3.315.076
  • Socket head cap screw M2x12 6.120.235
  • Centering ring (x2) 3.420.196 Press Force Sensor Fz 0 … 10 kN 9323AA
  • Threaded bushing 3.315.076
  • Socket head cap screw M2x12 6.120.235
  • Centering ring (x2) 3.420.196 Press Force Sensor Fz 0 … 20 kN 9323A
  • Threaded bushing 3.315.076
  • Socket head cap screw M2x12 6.120.235
  • Centering ring (x2) 3.420.196 Press Force Sensor Fz 0 … 50 kN 9333A
  • Connector protector 3.414.366
  • Threaded bushing 3.315.053
  • Socket head cap screw M4x12 6.120.102
  • Centering ring (x2) 3.420.179 Press Force Sensor Fz 0 … 70 kN 9343A
  • Connector protector 3.414.366
  • Threaded bushing 3.315.054
  • Socket head cap screw M6x18 6.120.122
  • Centering ring (x2) 3.420.180 Press Force Sensor Fz 0 … 120 kN 9363A
  • Connector protector 3.414.366
  • Threaded bushing 3.315.055
  • Socket head cap screw M10x25 6.120.066
  • Centering ring (x2) 3.420.181 Press Force Sensor Fz 0 … 300 kN 9383A Press Force Sensor 1) 9383AU0109
  • Connector protector 3.414.366
  • Threaded bushing 3.315.087
  • Socket head cap screw M16x50 55075248
  • Centering ring (x2) 3.420.197 Press Force Sensor Fz 0 … 700 kN 9393A Press Force Sensor 1) 9393AU0109
  • Connector protector 3.414.366
  • Socket head cap screw M30x40 6.120.136
  • Centering ring (x2) 3.420.280 1) Measuring and calibrated range customer-specific, on request Electrical connection We recommend using Kistler cables exclusively to prevent insulation resistance, triboelectricity and cable breakage pro- blems from the outset. Optional accessories Type
  • Connecting cable, 1631C… KIAG 10-32 pos. – BNC pos.
  • Connecting cable, 1633C… KIAG 10-32 pos. – TNC pos.
  • Connecting cable, 1635C… KIAG 10-32 pos. – KIAG 10-32 pos.
  • Connecting cable, 1939A… KIAG 10-32 pos. int. – BNC pos.
  • Connecting cable, 1941A… KIAG 10-32 pos. int. – TNC pos.
  • Connecting cable, KIAG 10-32 pos. – 1957A KIAG 10-32 pos.,with metal sheath
  • Connecting cable, KIAG 10-32 pos. – 1900A21A11... KIAG 10-32 pos., with robust metal sheath
  • Connecting cable, KIAG 10-32 pos. – 1900A21A12... BNC pos., with robust metal sheath
  • Connecting cable, KIAG 10-32 pos. – 1900A23A11... KIAG 10-32 pos., highly flexible, suitable for drag chains
  • Connecting cable, KIAG 10-32 pos. – 1900A23A12... BNC pos., highly flexible, suitable for drag chains
  • Flange 9580A…
  • Force distributing cap 9582A…
  • Adapter with female thread 9584A…
  • Adapter with male thread 9586A…
  • SCS calibration 9961F-AC