Product: RST 4L-RKT 4L-723 M12 Power Double-Ended Cordset: Male straight to Female straight, 4-pin, L-coded, blue body, 50 V AC/60 V DC, 16 A; PUR black cable, 1.50 mm² Product Description M12 Power Double-Ended Cordset: Male straight to Female straight, 4-pin, L-coded, blue body, 50 V AC/60 V DC, 16 A; PUR black cable, 1.50 mm² Technical Drawing Technical Specifications Product Description Product Family: Power Connector Brand: Lumberg Automation Connector Type: Cordset, double ended
Shielding: Unshielded Rated Voltage: 63 V Rated Voltage (UL): 63 V Rated Impulse Voltage: 1.5 kV Rated Current*: 16 A Rated Current (UL)*: 16 A Technical Data Side 1 Product Sub Family: M12 Power Type of Contact / Gender: male Connector Design: straight Attachment Type: Coupling Screw Number of Pins: 4 Coding: L Contact Resistance: ≤ 10 mOhm Insulation Resistance: ˃ 10^9 Ohm Mating Cycles: ≤ 100 Ambient Temperature (Operation)*: -40 °C to +125 °C, notice derating Protection Degree / IP Rating**: IP65, IP67, IP69K Design Standard: IEC 61076-2-111 Pollution Degree: 3 acc. to DIN EN 60664-1 (VDE 0110-1) Clearance / Creepage Distance: DIN EN 60664-1 (2008/01); VDE 0110-1 Overvoltage Category: III acc. to DIN EN 60664-1 (VDE 0110-1) Contact Base Material: CuNi Contact Plating: Cu/Au Contact Bearer Material: PBT GF Contact Bearer Color: black Flammability Class (Contact Bearer): UL 94 V-2 Molded Body Material: TPE Molded Body Color: blue Flammability Class (Molded Body): UL 94 HB Attachment Material: CuZn Attachment Plating: Cu/Ni O-Ring Material: FKM Fastening Torque (Contact Screw): M 12x1: (50-60) Ncm, hand-tight Cable Data Cable Number: 723 Conductor Size: 1.50 mm² Number of Wires: 4 Minimal Bending Radius (Fixed Inst): ˃ 4 x D Minimal Bending Radius (Flexible Inst): ˃ 7.5 x D Cycles (Bending): ˃ 10 M Conductor material: Cu Cable Jacket Material: PUR Cable Jacket Color: black Cable Diameter D: ø 7.4 ±0.20 mm Wire Insulation Material: PP Insulated Wire Diameter: ø 2.35 mm Overall Shield (Cable): - Ambient Temperature (Fixed Installation): -40 °C to +80 °C Ambient Temperature (Flex Installation): -30 °C to +80 °C Ambient Temperature (Fixed Installation short-term 100h): -40 °C to +125 °C Ambient Temperature (Drag Chain Inst): -20 °C to +60 °C UL Cable Type: AWM: 20939 Flammability Class (Cable Jacket): VDE 0482-332-1-2, DIN EN 60332-1-2 / IEC 60332-1 / UL VW-1, CSA FT1
Product Sub Family, Side 2: M12 Power Type of Contact / Gender, Side 2: female Connector Design, Side 2: straight Attachment Type, Side 2: Coupling Nut Number of Pins, Side 2: 4 Coding, Side 2: L Contact Resistance, Side 2: ≤ 10 mOhm Insulation Resistance, Side 2: ˃ 10^9 Ohm Mating Cycles, Side 2: ≤ 100 Ambient Temperature (Operation), Side 2*: -40 °C to +125 °C, notice derating Protection Degree / IP Rating, Side 2**: IP65, IP67, IP69K Design Standard, Side 2: IEC 61076-2-111 Pollution Degree, Side 2: 3 acc. to DIN EN 60664-1 (VDE 0110-1) Clearance / Creepage Distance, Side 2: DIN EN 60664-1 (2008/01); VDE 0110-1 Overvoltage Category, Side 2: III acc. to DIN EN 60664-1 (VDE 0110-1) Contact Base Material, Side 2: CuNi Contact Plating, Side 2: Cu/Au Contact Bearer Material, Side 2: PBT GF Contact Bearer Color, Side 2: black Flammability Class (Contact Bearer), Side 2: UL 94 V-2 Molded Body Material, Side 2: TPE Molded Body Color, Side 2: blue Flammability Class (Molded Body), Side 2: UL 94 HB Attachment Material, Side 2: CuZn Attachment Plating, Side 2: Cu/Ni O-Ring Material, Side 2: FKM Fastening Torque (Contact Screw), Side 2: M 12x1: (50-60) Ncm, hand-tight Approvals UL-File: E497237 UL: UL 2237; cULus VDE: Yes Safety & Environmental Compliance RoHS Compliant: Yes Resistances Halogenfree: DIN VDE 0472 T.815 Oil Resistance: HD 22.10 Appendix A, DIN EN 60811-404 Notes Note Derating: * Notice derating Product Characteristics: To ensure ingress protection, please check the O-ring’s position before connecting. Improperly positioned O-ring leads to ingress protection potential failure. Variants Item # Item Description Cable Length 934853193 RST 4L-RKT 4L-723/0,3 M 0.3 m 934853194 RST 4L-RKT 4L-723/0,5 M 0.5 m 934853195 RST 4L-RKT 4L-723/0,6 M 0.6 m
934853196 RST 4L-RKT 4L-723/1 M 1 m
934853197 RST 4L-RKT 4L-723/1,5 M 1.5 m
934853198 RST 4L-RKT 4L-723/2 M 2 m
934853199 RST 4L-RKT 4L-723/3 M 3 m
934853200 RST 4L-RKT 4L-723/5 M 5 m
934853201 RST 4L-RKT 4L-723/6 M 6 m
934853202 RST 4L-RKT 4L-723/10 M 10 m
934853203 RST 4L-RKT 4L-723/15 M 15 m
934853204 RST 4L-RKT 4L-723/20 M 20 m
© 2024 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product.