9286B KISTLER | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 4
Technical content
©2008 ... 2014, Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland Tel. +41 52 224 11 11, Fax +41 52 224 14 14, info@kistler.com, www.kistler.com Kistler is a registered trademark of Kistler Holding AG. This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded. Page 1/4 Force Multicomponent Force Plate Portable – for Applications in Biomechanics, F z 0 ... 10 kN 9286B_000-713e-02.14 Type 9286B... Portable multicomponent force plate with aluminum top plate for measuring ground reaction forces, moments and the center of pressure in biomechanics.
- Excellent accuracy of center of pressure (COP)
- Very wide measuring range
- Easy mounting
- Flexible, mobile application
- Threshold Fz <250 mN
Description
Rather than conventional frame mounted force plates, the multicomponent force plate Type 9286B... can simply be used on any flat surface. This drastically cuts installation costs. The plate's low overall height of just 35 mm and weight of under 18 kg allows flexible, portable use. The piezoelectric 3-component force sensors have very low crosstalk values and in conjunction with the special design principle ensure excellent accuracy of the center of pressure. Application This force plate is designed specifically for use in gait and bal - ance analyses. The Type 9286BA has a built-in charge amplifier compatible with all of the common motion analysis systems. Despite the very wide measuring range (0 ... 10 kN), this force plate offers excellent accuracy and linearity over the entire spectrum of applications (4 measuring ranges) and guarantees overload protection up to 12 kN. Technical Data Dimensions mm 600x400x35 Measuring range Fx, Fy kN –2,5 ... 2,5 Fz kN 0 ... 10 Overload F x, Fy kN –3/3 Fz kN 0/12 Linearity %FSO <±0,2 Hysteresis %FSO <0,3 Crosstalk F x <–> Fy % <±1,5 Fx, Fy –> Fz % <±2,0 Fz –> Fx, Fy % <±0,51) Rigidity x-axis (ay = 0) N/μm ≈12 y-axis (ax = 0) N/μm ≈12 z-axis (ax = ay = 0) N/μm ≈8 Natural frequency fn (x, y) Hz ≈350 fn (z) Hz ≈200 Operating temperature range °C 0 ... 60 Weight kg 17,5 Degree of protection EN 60529:1992 IP50/IP632) Force Plate without Charge Amplifier, Type 9286B Calibrated range Fx, Fy kN –2,5 ... 2,5 Fz kN 0 ... 5 Calibrated partial range Fx, Fy kN 0 ... 0,25 Fz kN 0 ... 1 Threshold F x, Fy, Fz mN <10 Sensitivity F x, Fy pC/N –7,8 3) Fz pC/N –3,6 3) 1) inside sensor rectangle 2) Type 9286B with charge output IP63 3) nominal value z x y
©2008 ... 2014, Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland Tel. +41 52 224 11 11, Fax +41 52 224 14 14, info@kistler.com, www.kistler.com Kistler is a registered trademark of Kistler Holding AG. This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded. Page 2/4 9286B_000-713e-02.14 Force Plate with Built-in 8 Channel Charge Amplifier, Type 9286BA Calibrated range 3 Fx, Fy kN –2,5 ... 2,5 Fz kN 0 ... 10 Calibrated partial range Fx, Fy kN 0 ... 0,25 Fz kN 0 ... 1 Sensitivity range 1 Fx, Fy mV/N ≈403) Fz mV/N ≈183) Sensitivity range 4 Fx, Fy mV/N ≈2,03) Fz mV/N ≈0,93) Ratio ranges 1:2:3:4 1 : 5 : 10 : 204) Threshold mN <2505) Drift mN/s <±10 Supply voltage V DC 10 ... 30 Supply current mA ≈45 (606) (600) (550)
4 Measuring element
3 Measuring element
x z y Measuring element 1 Measuring element 2 (350) (400) (406) (35) (34,5) (27) ø 56 Floor covering provided by user Load washer Anti-slip floor covering Output voltage V 0 ... ±5 Output current mA –2 ... 2 Control inputs (optocoupler) V 5 ... 45 mA 0,4 ... 4,4 3) nominal value 4) ±0,5 % accuracy 5) only range 1 Conforms to the ä safety standards (73/23/EG) for electrical equipment and systems: EN 60601-1:2005, EN 61010-1:2001 and the EMC standards (89/336/EG): EN 60601-1:2005 (EN 55022 Class B), EN 61000-6-3:2004 (EN 55022 Class B), EN 61000-6-4:2001 (EN 55011 Class B), EN 60601-1:2005, EN 61000-6-1:2001, EN 61000-6-2:2005 Dimensions Fig. 1: Dimensions of portable multicomponent force plate Type 9286BA Walkway Type 9401B... Four different lightweight sandwich elements are available for assembling a walkway of any length with various arrange - ments of force plates. An anti-slip floor covering provides safety on the walkway as well as on the force plate. 620 mm 1200 mm 800 mm 620 mm 200 mm 35 mm 140 mm 600m m 400m m Walkway: 1 = Type 9401B01, 2 = Type 9401B02, 3 = Type 9401B03, 4 = Type 9401B04 Fig. 2: Mounting examples
©2008 ... 2014, Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland Tel. +41 52 224 11 11, Fax +41 52 224 14 14, info@kistler.com, www.kistler.com Kistler is a registered trademark of Kistler Holding AG. This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded. Page 3/4 9286B_000-713e-02.14 BioWare provides several performance specific evaluations. Parameters of Countermovement Jump CMJ Other parameters
- Acceleration, velocity and displacement of the center of mass (COM)
- Work, energy, impulse
- Statistics, digital filters Fig. 10: Force gradient (Explosivity) Fig. 9: Jump height (COM) Fig. 8: Power Fig. 7: Jump force BioWare® BioWare software is the engine behind the force plate system. It collects data from the force plates, converts the trials into useful information and plots the results. The force plates and charge amplifiers are fully remote controlled by BioWare thus making the system extremely flexible and easy-to-use. Parameters of Gait Fig. 3: Ground reaction forces (GRF) Fig. 6: Force vector Fig. 5: Frictional torque Tz Fig. 4: Center of pressure (COP) Other functions
- Coefficient of friction (COF)
- Frequency analysis, statistics, digital filters
- Full Windows® functionality Windows® is a registered trade mark of Microsoft Corporation.
©2008 ... 2014, Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland Tel. +41 52 224 11 11, Fax +41 52 224 14 14, info@kistler.com, www.kistler.com Kistler is a registered trademark of Kistler Holding AG. This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded. Page 4/4 9286B_000-713e-02.14 Included Accessories Type/Art. No.
- 1 shim set 7.050.031
- 1 voltage equalizing cable 5.590.175 Optional Accessories Type/Art. No. For Type 9286BA with built-in charge amplifier
- 16ch DAQ-System for BioWare (USB 2.0) 5691A1
- Connection cable for 5691A, straight plug 1758A...
- Connection cable for 5691A, angle plug 1759A...
- 64ch DAQ-System for BioWare (USB 2.0) 5695B1
- Connection cable for 5695B, straight plug 1700A105B…
- Connection cable for 5695B, angle plug 1700A105A…
- External Control Unit (BNC out) 5233A2
- DAQ system BioWare (PCI-Bus) 2812A... Portable Multicomponent Force Plate with charge output – with built-in charge amplifier A Ordering Key Type 9286B Fig. 12: Configuration of a typical measuring chain Ch 1 = Fx 1+2 Ch 5 = Fz 1 Ch 2 = Fx 3+4 Ch 6 = Fz 2 Ch 3 = Fy 1+4 Ch 7 = Fz 3 Ch 4 = Fy 2+3 Ch 8 = Fz 4 Force plate with built-in charge amplifier Type 9286BA Connection cable Type 1760A... External Control Unit (8xBNC neg.) Type 5233A2 DAQ system provided by user (8 analog channels) Typical Measuring Chains Force plate with built-in charge amplifier Type 9286BA Connection cable Type 1758A... DAQ system (USB 2.0) Type 5691A1 Laptop (provided by user) with BioWare Fig. 11: Configuration of a typical measuring chain with Kistler DAQ system BioWare® BioWare® is a registered trade mark of Kistler Holding AG. For Type 9286B with charge output
- External charge amplifier 9865E...
- Connection cable, straight plug 1685B...
- Connection cable, angle plug 1686A...
- DAQ system for BioWare (PCI-Bus) 2812A... For Type 9286B...
- Walkway, central piece 9401C01
- Walkway, extension 9401C02
- Walkway, intermediary piece 9401C03
- Walkway, ramp 9401C04