©2010, Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland Tel. +41 52 224 11 11, Fax +41 52 224 14 14, info@kistler.com, www.kistler.com This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded. Page 1/3 Force Multicomponent Force Plate with Glass Top Plate for Biomechanics, Fz 0 ... 10 kN 9285BA_000-743e-02.10 Type 9285BA Multicomponent force plate with glass top plate for measuring ground reaction forces, moments and the center of pressure in biomechanics.
- Glass top plate allows recording of contact surface
- Wide measuring range
- Excellent measuring accuracy
- Good accuracy of center of pressure (COP)
- Threshold Fz <250 mN
Description
Multicomponent force plate Type 9285BA consists of a base frame on which four piezoelectric 3-component force sensors under a high preload are mounted. A 600x400 mm triple-layer composite glass plate is mounted on these sensors. The very low crosstalk values of the sensors in conjunction with the spe- cial design principle ensure very good accuracy of the center of pressure. Type 9285BA has a built-in charge amplifier compat- ible with all of the common motion analysis systems. Application This force plate is designed for special gait and balance analysis applications. The glass plate allows simultaneous force meas- urement and photographic or cinematographic recording of the contact surface from below. Despite the wide measuring range (0 ... 10 kN), this force plate offers excellent accuracy and linearity across the entire spectrum of applications and guarantees overload protection up to 12 kN. A larger force plate with external dimensions of 900x600 mm is available on request. Technical Data Dimensions mm 600x400x150,4 Range Fx, Fy kN –2,5 ... 2,5 Fz kN 0 ... 10 Overload Fx, Fy kN –6/6 Fz kN 0/12 Linearity %FSO ≤±0,5 Hysteresis %FSO ≤0,5 Crosstalk Fx <–> Fy % <±2 Fx, Fy –> Fz % <±2 Fz –> Fx, Fy % <±0,5 Rigidity x-axis (ay = 0) N/μm ≈120 y-axis (ax = 0) N/μm ≈115 z-axis (ax = ay = 0) N/μm ≈25 Natural frequency fn (x, y) Hz ≈300 fn (z) Hz ≈500 Operating temperature range °C 0 ... 60 Weight kg 45 Degree of protection EN 60529:1992 IP65 Refractive index of glass top plate n ≈1,52 z x y
©2010, Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland Tel. +41 52 224 11 11, Fax +41 52 224 14 14, info@kistler.com, www.kistler.com This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded. Page 2/3 Multicomponent Force Plate with Glass Top Plate for Biomechanics, Fz 0 ... 10 kN, Type 9285BA 9285BA_000-743e-02.10 Dimensions COP F Fig. 2: This photograph taken through the glass plate from below shows the main part of the standing phase of a step Fig. 1: Dimensions of multicomponent force plate Type 9285BA Technical Data (Cont.) Force Plate with Built-in 8-Channel Charge Amplifier (4 Measuring Ranges) Calibrated partial range F x, Fy kN 0 ... 0,25 Fz kN 0 ... 1 Calibrated range Fx, Fy kN 0 ... 1,25 Fz kN 0 ... 5 Sensitivity range 1 Fxi, Fyi mV/N ≈37,5 Fzi mV/N ≈19,0 Sensitivity range 2 Fxi, Fyi mV/N ≈7,5 Fzi mV/N ≈3,8 Sensitivity range 3 Fxi, Fyi mV/N ≈3,8 Fzi mV/N ≈1,9 Sensitivity range 4 Fxi, Fyi mV/N ≈1,9 Fzi mV/N ≈0,9 Ratio range 1:2:3:4 1:5:10:201) Threshold mN <2502) Drift Fx, Fy mN/s <5 Fx mN/s <10 Supply voltage VDC 10 ... 30 Supply current mA ≈45 Output voltage V 0 ... ±5 Output current mA –2 ... 2 Control inputs (optocoupler) V 5 ... 45 mA 0,4 ... 4,4 1) ±0,5 % accuracy 2) range 1 only Conforms to the ä safety standards (73/23/EG) for electrical equipment and systems: EN 60601-1:2005, EN 61010-1:2001 and the EMC standards (89/336/EG): EN 60601-1:2005 (EN 55022 Class B), EN 61000-6-3:2004 (EN 55022 Class B), EN 61000-6-4:2001 (EN 55011 Class B), EN 60601-1:2005, EN 61000-6-1:2001, EN 61000-6-2:2005.
©2010, Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland Tel. +41 52 224 11 11, Fax +41 52 224 14 14, info@kistler.com, www.kistler.com This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded. Page 3/3 Multicomponent Force Plate with Glass Top Plate for Biomechanics, Fz 0 ... 10 kN, Type 9285BA 9285BA_000-743e-02.10 Typical Measuring Chains Included Accessories Type/Art. No.
- 1 Set shims 7.050.011
- 4 Hexagon socket head cap screws 6.120.106 M12x25
- 1 Hexagon socket wrench 1391
- 4 Eye bolts M10 (DIN 580) 6.170.025
- 1 Sylgard 170 A&B Elastomer 6.921.001
- 1 Voltage equalizing cable 5.590.175 Optional Accessories Type/Art. No.
- Connection cable: 1758A5, Force plate –> BioWare 1758A10, 1758Asp
- DAQ system BioWare 5691A1 or 2812A...
- Connection cable: 1760A5, Force plate –> Control Unit 1760A10, 1760Asp
- Remote Control Unit 5233A2
- Mounting frame Z12627 Ordering Code
- Multicomponent force plate Type 9285BA with charge output Fig. 3: Configuration of a typical measuring chain with Kistler DAQ system BioWare® Multicomponent force plate with charge amplifier Type 9285BA Connection cable Type 1758A... DAQ system (USB 2.0) Type 5691A1 Laptop (provided by customer) with BioWare Fig. 4: Configuration of a typical measuring chain with DAQ system provided by customer Ch 1 = Fx 1+2 Ch 5 = Fz 1 Ch 2 = Fx 3+4 Ch 6 = Fz 2 Ch 3 = Fy 1+4 Ch 7 = Fz 3 Ch 4 = Fy 2+3 Ch 8 = Fz 4 Multicomponent force plate with charge amplifier Type 9285BA Connection cable Type 1760A... External Control Unit (8xBNC fem.) Type 5233A2 DAQ system provided by customer (8 analog channels)