DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 10

Technical content

Twinax • 24 AWG Stranded (19x36) .024″ Silver-coated High-Strength Copper Alloy Conductor • SCHSCA Braid Shield (93% Coverage) TFE Teflon® Insulation • Blue PFA Jacket (Color Code: White, Blue) 1000 † 304.8 16.0 7.3 (19x36) 93% Shield .024″ Coverage SCHSCA 7.3 Ω/M′ 24.0Ω/M′ 24.0Ω/km 78.7Ω/km M17/176-00002 Twinax • 20 AWG Stranded (7x28) .038″ Tinned Copper Conductor • Tinned Copper Braid Shield (85% Coverage) Polyethylene Insulation • Black Non-contaminating PVC Jacket (One conductor has bare strand for ID) (7x28) 85% Shield .038″ Coverage TC 5.3 Ω/M′ 9.5Ω/M′ 17.4Ω/km 31.2Ω/km M17/45-RG108 DCR = DC Resistance • PFA = Perfluoroalkoxy • SCHSCA = Silver-coated High-strength Copper Alloy • TC = Tinned Copper • TFE = Tetra Fluo roethylene Contact the Belden Customer Service Department for a Comprehensive Connector Cross Reference. 1-800-BELDEN-1. †Spools may contain more than one piece. Minimum length of any one piece is 50 ft. Length may vary ±10% from length shown for sp ools or reels and ±5% UnReel® cartons. Not RoHS compliant at time of printing. Please check with Belden Technical Support for current compliance information at 1-800- BELDEN-1. COAXIAL CABLES 6.81 6 • Coaxial Cables For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com MIL-C-17G QPL Cable Twinax 1 1.2 3.9 10 4.0 13.1 50 9.2 30.2 100 13.0 42.7 200 18.4 60.4 400 26.1 85.6 700 34.6 113.5 900 39.3 128.9 1000 41.4 135.8 1 .7 2.3 10 2.3 7.5 50 5.2 17.1 100 7.5 24.6 200 11.0 36.1 400 16.0 52.5 Teflon is a DuPont trademark. Shielding Materials Nom. DCR Nom. Imp. (Ω) Nominal Core OD Nominal OD Inch mm Inch mm Conductor (stranding) Diameter Nom. DCR Standard Unit WeightStandard Lengths Lbs. kgFt. m UL NEC/ C(UL) CEC Type Part No. MHz dB/ 100 Ft. dB/ 100m Nominal Attenuation Nominal Capacitance pF/mpF/Ft. Nom. Vel. of Prop.

Description

COAXIAL CABLES 6.82 For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com Miniature • 28 AWG Solid .013″ Tinned Copper Conductor • Bare Copper Braid Shield (90% Coverage) Polypropylene Insulation • Black PVC Jacket VW-1 CMH (solid) 90% Shield CEC: .013″ Coverage CMH FT1 TC 28.7 Ω/M′ 66.9Ω/M′ 94.2Ω/km 219.5Ω/km Low Noise • RG-174/U Type • 26 AWG Stranded (7x34) .019″ Bare Copper-covered Steel Conductor • TC Braid Shield (90% Coverage) Polyethylene Insulation • Conductive Layer • Black PVC Jacket 500 152.4 4.5 2.0 (7x34) 90% Shield 1000 304.8 8.0 3.6 .019 ″ Coverage BCCS 14.0 Ω/M′ 97.0Ω/M′ 45.9Ω/km 318.3Ω/km 5mV peak-to-peak max. Not recommended for RF use. Low Noise • RG-59/U Type • 22 AWG Solid .025″ Bare Copper-covered Steel Conductor • Bare Copper Braid Shield (93% Coverage) Polyethylene Insulation • Conductive Layer • Black PVC Jacket VW-1 1000 304.8 39.0 17.7 (solid) 93% Shield .025″ Coverage BCCS 2.5 Ω/M′ 54.0Ω/M′ 8.2Ω/km 177.0Ω/km 5mV peak-to-peak max. Not recommended for RF use. Low Noise • RG-58/U Type • 22 AWG Stranded (7x30) .030″ TC Conductor • Duobond® II + TC Braid Shield (95% Coverage) Polyethylene Insulation • Conductive Layer • Black PVC Jacket VW-1 500 152.4 12.0 5.4 (7x30) + 95% 1000 304.8 24.0 10.9 .030 ″ TC Braid TC 100% Shield 10.8Ω/M′ Coverage 35.4Ω/km 4.1 Ω/M′ 8mV peak-to-peak max. 13.5Ω/km Not recommended for RF use. BC = Bare Copper • BCCS = Bare Copper-covered Steel • DCR = DC Resistance • TC = Tinned Copper Contact the Belden Customer Service Department for a Comprehensive Connector Cross Reference. 1-800-BELDEN-1. *Duobond II = Bonded Duofoil® (100% coverage) + aluminum braid (67% coverage). Special Audio, Communication and Instrumentation Cable Miniature Instrumentation and Low Triboelectric Noise Coax 1 2.5 8.2 10 7.7 25.3 50 17.2 56.4 100 24.5 80.4 200 34.8 114.2 400 50.0 164.4 700 66.0 216.5 900 75.0 246.1 1000 79.0 259.2 Shielding Materials Nom. DCR Nom. Imp. (Ω) Nominal Core OD Nominal OD Inch mm Inch mm Conductor (stranding) Diameter Nom. DCR Standard Unit WeightStandard Lengths Lbs. kgFt. m UL NEC/ C(UL) CEC Type Part No. MHz dB/ 100 Ft. dB/ 100m Nominal Attenuation Nominal Capacitance pF/mpF/Ft. Nom. Vel. of Prop.

Thinnet 10Base2 Ethernet • 20 AWG Stranded (19x32) .037″ Conductor • Duobond® II + Overall TC Braid Shield (93% Coverage) Non-plenum • Foam Polyethylene Insulation • Gray PVC Jacket Style 1354 CL2 U-1000 U-304.8 24.0 10.9 (19x32) + 93% (30V 60°C) CM 1000 304.8 23.0 10.4 .037 ″ TC Braid CEC: 1640 500.0 41.0 18.6 TC 5.8 Ω/M′ 3280 1000.0 82.0 37.3 28.9 Ω/km RG-58A/U Type DEC Part No. 17-01248-00 Plenum • Foam FEP Insulation • Gray Fluorocopolymer Jacket CMP 1000 † 304.8 22.0 10.0 (19x32) + 93% CL2P 2500 † 762.0 60.0 27.3 .037 ″ TC Braid CEC: TC 5.8 Ω/M′ CMP FT6 8.8Ω/M′ 19.0Ω/km 28.9Ω/km RG-58A/U Type DEC Part No. 17-01246-00. Suitable for Outdoor applications. Plenum • FPFA Insulation • Natural Flamarrest® Jacket CMP U-1000 †† U-304.8 23.0 10.5 (19x32) + 93% CL2P 1000 † 304.8 22.0 10.0 .037 ″ TC Braid CEC: 2500 † 762.0 57.5 26.1 TC 5.8 Ω/M′ CMP FT6 8.8Ω/M′ 19.0Ω/km 28.9Ω/km RG-58A/U Type Thicknet 10Base5 Ethernet • 12 AWG Solid .086″ Bare Copper Conductor • Duobond IV Quad Shield (100% Coverage) Non-plenum • Foam Polyethylene Insulation • Yellow PVC Jacket Style 1478 CL2 1000 304.8 131.0 59.5 (solid) (Duobond II (30V 60°C) CM 1640 500.0 219.8 99.7 .086 ″ + 94% TC Braid CEC: BC + Duofoil CM 1.4Ω/M′ + 90% TC 4.7Ω/km Braid) 1.5Ω/M′ DEC Part No. 17-00451-00 5.0Ω/km Ring-band stripes marked every 2.5 meters to aid users in tap placement. Plenum • Foam FEP Insulation • Orange Fluorocopolymer Jacket CL2P 1640 † 500.0 224.7 102.1 (solid) (Duobond II CMP .086 ″ + 90% TC Braid CEC: BC + Duofoil CMP FT6 1.4Ω/M′ + 90% TC 4.7Ω/km Braid) DEC Part No. 17-00324-00 1.5Ω/M′ Ring-band stripes marked every 2.5 meters to aid users in tap placement. 5.0Ω/km Suitable for Outdoor and Direct Burial applications. BC = Bare Copper • DCR = DC Resistance • FEP = Fluorinated Ethylene Propylene • FPFA = Foam Perfluoroalkoxy • TC = Tinned Copper Contact the Belden Customer Service Department for a Comprehensive Connector Cross Reference. 1-800-BELDEN-1. For cable manufactured to latest government revision or other MIL-SPEC requirements, please contact your nearest Belden Regiona l Sales Office. *Duobond II = Bonded Duofoil® (100% coverage) + aluminum braid (67% coverage). Duobond IV = Bonded Duofoil (100% coverage) + aluminum braid (67% coverage) + Duofoil (100% coverage) + aluminum braid (46% cov erage). † Final put-up length may vary from length shown ±10% for spools and reels, ±5% for UnReel ® cartons. †† Length may vary -0/+10%. COAXIAL CABLES 6.83 6 • Coaxial Cables For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com Computer and Instrumentation Cable

50 Ohm Ethernet® Coax

1 .4 1.4 10 1.3 4.3 50 2.9 9.5 100 4.2 13.8 200 6.1 20.0 400 8.9 29.2 700 12.1 39.7 900 13.9 45.6 1000 14.8 48.6 1 .4 1.4 10 1.3 4.3 50 2.9 9.5 100 4.2 13.7 200 6.1 20.0 400 9.2 30.2 700 12.9 42.3 900 15.0 49.2 1000 16.0 52.5 1 .4 1.4 10 1.3 4.3 50 2.9 9.5 100 4.2 13.7 200 6.1 20.0 400 9.2 30.2 700 12.9 42.3 900 15.0 49.2 1000 16.0 52.5 1. 2. 6 5 .4 1.2 10 .5 1.7 50 1.2 3.9 100 1.7 5.6 200 2.6 8.4 400 3.9 12.8 700 5.5 18.1 900 6.5 21.3 1000 6.9 22.6 1. 2. 6 5 .4 1.2 10 .5 1.7 50 1.2 3.8 100 1.7 5.4 200 2.5 8.0 400 3.8 12.5 700 5.6 18.4 900 6.8 22.3 1000 7.2 23.6 For Plenum versions see 89907 or 82907. For Non-plenum version see 9907. For Non-plenum version see 9907. For Plenum version see 89880. Shielding Materials Nom. DCR Nom. Imp. (Ω) Nominal Core OD Nominal OD Inch mm Inch mm Conductor (stranding) Diameter Nom. DCR Standard Unit WeightStandard Lengths Lbs. kgFt. m UL NEC/ C(UL) CEC Type Part No. MHz dB/ 100 Ft. dB/ 100m Nominal Attenuation Nominal Capacitance pF/mpF/Ft. Nom. Vel. of Prop.

75 Ohm • 30 AWG Stranded (7x38) .012″ Silver-plated Copper-covered Steel Conductor • Silver-plated Copper Braid Shield (95% Coverage) TFE Teflon® Insulation • White TFE Tape Jacket VW-1 1000 † 304.8 11.0 5.0 (7x38) 95% Shield .012″ Coverage SPCCS 8.6 Ω/M′ 244.0Ω/M′ 28.2Ω/km 801.0Ω/km RG-187A/U Type • MIL-C-17D 75 Ohm • Dual RG-59/U Type • 23 AWG Solid .023″ Bare Copper-covered Steel Conductors • Bare Copper Braid Shield (95% Coverage) Flame-retardant Semi-foam Polyethylene Insulation • Black PVC Jacket Style 20063 CM 1000 304.8 78.0 35.4 (solid) 95% Shield xx CM BCCS 2.6 Ω/M′ 50.0Ω/M′ 8.5Ω/km 164.0Ω/km 75 Ohm • Dual RG-59/U Type • 23 AWG Solid .023″ Bare Copper-covered Steel Conductors • Bare Copper Braid Shield (97% Coverage) Plenum • FEP Insulation • Clear FEP Jacket CMP 1000 304.8 90.0 40.9 (solid) 97% Shield xx CEC: .023″ Coverage .424 10.77 CMP FT6 BCCS 2.6 Ω/M′ 50.0Ω/M′ 8.5Ω/km 164.0Ω/km Suitable for Outdoor and Direct Burial applications. 75 Ohm • RG-6/U Type • 18 AWG Solid Bare Copper-covered Steel Conductor • Duobond® IV Quad Shield (100% Coverage) Non-Plenum • Gas-injected Foam Polyethylene Insulation • Gray PVC Jacket CL2R, 2500 †† 762.2 97.5 44.3 (solid) Quad Shield CMR .040″ 3.6Ω/M′ CEC: BCCS 11.8 Ω/km CMR FT4 28.0Ω/M′ 91.9Ω/km Plenum • Foam FEP Insulation • Gray Fluorocopolymer Jacket CMP (solid) Quad Shield CEC: .040″ 7.2Ω/M′ CMP FT6 BCCS 23.6 Ω/km 28.0Ω/M′ 19.9Ω/km Suitable for Outdoor and Direct Burial applications. 75 Ohm • RG-11/U Type • 14 AWG Solid Bare Copper-covered Steel Conductor • Duobond IV Quad Shield (100% Coverage) Non-Plenum • Gas-injected Foam Polyethylene Insulation • Gray PVC Jacket CL2R, 1000 304.8 69.0 31.3 (solid) Quad Shield CEC: BCCS 4.9 Ω/km CMG FT4 11.0Ω/M′ 36.1Ω/km Tap marks every 2.6 meters to aid users in installation. BC = Bare Copper • BCCS = Bare Copper-covered Steel • DCR = DC Resistance • FEP = Fluorinated Ethylene Propylene • SPC = Silver-coated Copper • SPCCS = Silver-coated Copper-covered Steel • TFE = Tetra Fluoroethylene Contact the Belden Customer Service Department for a Comprehensive Connector Cross Reference. 1-800-BELDEN-1. * Duobond IV = Bonded Duofoil® (100% coverage) + aluminum braid (67% coverage) + Duofoil (100% coverage) + aluminum braid (46% c overage). † May contain more than one piece, minimum length of any one piece is 25 ft. †† Spools may contain more than one piece. Final put-up may vary ±10% for spools and reels and ±5% for UnReel ® cartons. 25 feet minimum length. COAXIAL CABLES 6.84 For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com Computer and Instrumentation Cable

75 Ohm Coax

1 3.0 9.8 10 5.3 17.4 50 8.5 27.9 100 10.0 32.8 200 12.5 41.0 400 16.0 52.5 700 19.7 64.6 900 22.3 73.2 1000 24.0 78.7 1 .6 2.0 10 1.1 3.6 50 2.4 7.9 100 3.4 11.2 200 4.9 16.1 400 7.0 23.0 700 9.7 31.8 900 11.1 36.4 1000 12.0 39.4 1 .5 1.6 10 1.1 3.6 50 2.5 8.2 100 3.5 11.5 200 5.1 16.7 400 7.5 24.6 700 10.4 34.1 900 12.0 39.4 1000 12.7 41.7 For Plenum version of see 89555. Sweep tested 5 MHz to 400 MHz. CPE jacket optional. For Non-plenum version see 3131A. Sweep tested 5 MHz to 400 MHz. Sweep tested 5 MHz to 400 MHz. CPE jacket optional. Shielding Materials Nom. DCR Nom. Imp. (Ω) Nominal Core OD Nominal OD Inch mm Inch mm Conductor (stranding) Diameter Nom. DCR Standard Unit WeightStandard Lengths Lbs. kgFt. m UL NEC/ C(UL) CEC Type Part No. MHz dB/ 100 Ft. dB/ 100m Nominal Attenuation Nominal Capacitance pF/mpF/Ft. Nom. Vel. of Prop. 1 .35 1.15 2 .38 1.25 5 .45 1.48 10 .59 1.94 20 .86 2.82 50 1.37 4.50 100 1.97 6.46 200 2.82 9.25 300 3.48 11.42 400 4.04 13.26 1 .36 1.18 2 .38 1.25 5 .50 1.64 10 .65 2.13 20 .95 3.12 50 1.50 4.92 100 2.12 6.96 200 2.99 9.81 300 3.66 12.01 400 4.23 13.88 1 .16 .53 2 .18 .59 5 .26 .85 10 .38 1.25 20 .55 1.81 50 .83 2.72 100 1.17 3.84 200 1.60 5.25 300 1.99 6.53 400 2.30 7.55 Teflon is a DuPont trademark.

75 Ohm • RG-11/U Type • 14 AWG Solid Bare Copper-covered Steel Conductor • Duobond IV Quad Shield (100% Coverage) Plenum • Foam FEP Insulation • Gray Fluorocopolymer Jacket CMP , (solid) Quad Shield PLTC .064″ 3.9Ω/M′ CEC: BCCS 12.8 Ω/km CMP FT6 11.0Ω/M′ Suitable for Outdoor and Direct Burial applications. 36.1Ω/km Tap marks every 2.6 meters to aid users in installation. 93 Ohm • RG-62B/U Type • 24 AWG Stranded (7x32) .024″ Bare Copper-covered Steel Conductor • BC Braid Shield (95% Coverage) Semi-solid Polyethylene Insulation • Black Non-contaminating PVC Jacket Style 1354 CMX 1000 304.8 36.0 16.3 (7x32) 95% Shield (30V 60°C) CEC: .024″ Coverage VW-1 CMX BCCS 2.9 Ω/M′ 59.0Ω/M′ 9.5Ω/km 193.6Ω/km MIL-C-17D 93 Ohm • RG-62/U Type • JAN-C-17A • 22 AWG Solid .025″ Bare Copper-covered Steel Conductor • BC Braid Shield (95% Coverage) Semi-solid Polyethylene Insulation • Black PVC Jacket 500 152.4 16.5 7.5 (solid) 95% Shield U-1000 U-304.8 35.0 15.9 .025 ″ Coverage 1000 304.8 36.0 16.3 BCCS 2.9 Ω/M′ 41.2Ω/M′ 9.5Ω/km 135.1Ω/km 93 Ohm • RG-62A/U Type • 22 AWG Solid .025″ Bare Copper-covered Steel Conductor • Bare Copper Braid Shield (95% Coverage) Semi-solid Polyethylene Insulation • Black High-density Polyethylene Jacket 80°C 1000 304.8 33.0 15.0 (solid) 95% Shield 2000 609.6 68.0 30.9 .025 ″ Coverage 5000 1524.0 170.0 77.3 BCCS 2.9 Ω/M′ 41.2Ω/M′ 9.5Ω/km 135.1Ω/km Suitable for Outdoor and Direct Burial applications. Semi-solid Polyethylene Insulation • Black PVC Jacket Style 1478 CM CL2 U-1000 U-304.8 42.0 19.1 (solid) 95% Shield (30V 60°C) CEC: 1000 304.8 44.0 20.0 .025 ″ Coverage CM 2000 609.6 88.0 40.0 BCCS 2.9 Ω/M′ 41.2Ω/M′ 9.5Ω/km 135.1Ω/km IBM P/N 5252750 • Includes Mylar ® tape as a moisture barrier for improved outdoor reliability. Style 1478 CM CL2 500 152.4 17.0 7.7 (solid) 95% Shield (30V 60°C) CEC: U-1000 ▲ U-304.8 36.0 16.7 .025 ″ Coverage CM 1000 304.8 38.0 17.2 BCCS 2.9 Ω/M′ 2000 609.6 76.0 34.5 135.1 Ω/km 3280 1000.0 121.4 55.0 5000 1524.0 185.0 84.0 IBM P/N 323921 P-MSHA SC-1823** U-1000 put-up also available in Orange, Beige or Chrome. BC = Bare Copper • BCCS = Bare Copper-covered Steel • DCR = DC Resistance • FEP = Fluorinated Ethylene Propylene Contact the Belden Customer Service Department for a Comprehensive Connector Cross Reference. 1-800-BELDEN-1. For cables manufactured to latest government revision or other MIL-SPEC requirements, please contact your nearest Belden region al Sales Office. * Duobond IV = Bonded Duofoil® (100% coverage) + aluminum braid (67% coverage) + Duofoil (100% coverage) + aluminum braid (46% coverage). ** Pennsylvania Department of Environmental Resources and United States Mine Safety and Health Administration Certification. COAXIAL CABLES 6.85 6 • Coaxial Cables For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com Computer and Instrumentation Cable

75 Ohm and 93 Ohm Coax

  1. 3. 8 10 .9 2.8 50 1.9 6.2 100 2.7 8.9 200 3.8 12.5 400 5.3 17.4 700 7.3 23.9 900 8.2 26.9 1000 8.7 28.5 1. 3. 8 10 .9 2.8 50 1.9 6.2 100 2.7 8.9 200 3.8 12.5 400 5.3 17.4 700 7.3 23.9 900 8.2 26.9 1000 8.7 28.5 1. 3. 8 10 .9 2.8 50 1.9 6.2 100 2.7 8.9 200 3.8 12.5 400 5.3 17.4 700 7.3 23.9 900 8.2 26.9 1000 8.7 28.5 1. 3. 8 10 .9 2.8 50 1.9 6.2 100 2.7 8.9 200 3.8 12.5 400 5.3 17.4 700 7.3 23.9 900 8.2 26.9 1000 8.7 28.5 For Plenum version of 9269, see 89269, 87269 and 82269. Sweep tested 5 MHz to 400 MHz. Shielding Materials Nom. DCR Nom. Imp. (Ω) Nominal Core OD Nominal OD Inch mm Inch mm Conductor (stranding) Diameter Nom. DCR Standard Unit WeightStandard Lengths Lbs. kgFt. m UL NEC/ C(UL) CEC Type Part No. MHz dB/ 100 Ft. dB/ 100m Nominal Attenuation Nominal Capacitance pF/mpF/Ft. Nom. Vel. of Prop.

1 .20 .70 10 .39 1.30 50 1.20 3.90 100 1.70 5.60 200 2.50 8.20 400 3.50 11.50 1 .3 1.0 10 .9 3.0 50 2.0 6.6 100 2.9 9.5 200 4.2 13.8 400 6.1 20.0 700 8.6 28.2 900 10.1 33.1 1000 11.1 36.4 Mylar is a DuPont trademark.

COAXIAL CABLES 6.86 For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com RG-62/U Type • 22 AWG Solid .025″ Bare Copper-covered Steel Conductor • Bare Copper Braid Shield (94% Coverage) Plenum • Semi-solid FEP Teflon® Insulation • Black or White Tint FEP Jacket CMP 500 152.4 16.5 7.5 (solid) 94% Shield CEC: 1000 304.8 33.0 15.0 .025 ″ Coverage CMP FT6 BCCS 3.4 Ω/M′ 41.2Ω/M′ 11.2Ω/km 135.2Ω/km ▲100 ft. put-up available in Black only. Suitable for Outdoor and Direct Burial applications. Plenum • Semi-solid FEP Teflon Insulation • Gray Fluorocopolymer Jacket CMP (solid) 94% Shield CEC: .025″ Coverage CMP FT6 BCCS 3.4 Ω/M′ 41.2Ω/M′ 11.2Ω/km 135.2Ω/km Suitable for Outdoor and Direct Burial applications. Plenum • Semi-solid FEP Teflon Insulation • Natural Flamarrest® Low-smoke Jacket CMP (solid) 94% Shield CEC: .025″ Coverage CMP FT6 BCCS 3.4 Ω/M′ 41.2Ω/M′ 11.2Ω/km 135.2Ω/km Plenum • Foam FEP Teflon Insulation • White Tint FEP Jacket CMP 1000 304.8 32.0 14.5 (solid) 94% Shield CEC: .025″ Coverage CMP FT6 BCCS 3.4 Ω/M′ 41.2Ω/M′ 11.2Ω/km 135.2Ω/km Suitable for Outdoor and Direct Burial applications. Plenum • Foam FEP Teflon Insulation • Natural Flamarrest Jacket CMP 1000 304.8 30.0 13.6 (solid) 94% Shield CEC: .025″ Coverage CMP FT6 BCCS 3.4 Ω/M′ 41.2Ω/M′ 11.2Ω/km 135.2Ω/km BC = Bare Copper • BCCS = Bare Copper-covered Steel • DCR = DC Resistance • FEP = Fluorinated Ethylene Propylene Contact the Belden Customer Service Department for a Comprehensive Connector Cross Reference. 1-800-BELDEN-1. Computer and Instrumentation Cable

93 Ohm Coax

1 .3 1.0 10 .9 3.0 50 1.9 6.2 100 2.7 8.9 200 3.8 12.5 400 5.3 17.4 700 7.3 23.9 900 8.2 26.9 1000 8.7 28.5 1 .3 1.0 10 .9 3.0 50 1.9 6.2 100 2.7 8.9 200 3.8 12.5 400 5.3 17.4 700 7.3 23.9 900 8.2 26.9 1000 8.7 28.5 1 .3 1.0 10 .9 3.0 50 1.9 6.2 100 2.7 8.9 200 3.8 12.5 400 5.3 17.4 700 7.3 23.9 900 8.2 26.9 1000 8.7 28.5 1 .3 1.8 10 .9 3.0 50 1.9 6.2 100 2.7 8.9 200 3.8 12.5 400 5.3 17.4 700 7.3 23.9 900 8.2 26.9 1000 8.7 28.5 1 .3 1.8 10 .9 3.0 50 1.9 6.2 100 2.7 8.9 200 3.8 12.5 400 5.3 17.4 700 7.3 23.9 900 8.2 26.9 1000 8.7 28.5 Shielding Materials Nom. DCR Nom. Imp. (Ω) Nominal Core OD Nominal OD Inch mm Inch mm Conductor (stranding) Diameter Nom. DCR Standard Unit WeightStandard Lengths Lbs. kgFt. m UL NEC/ C(UL) CEC Type Part No. MHz dB/ 100 Ft. dB/ 100m Nominal Attenuation Nominal Capacitance pF/mpF/Ft. Nom. Vel. of Prop. Teflon is a DuPont trademark.

78 Ohm • 20 AWG Stranded (7x28) .038″ Tinned Copper Conductors • Tinned Copper Braid Shield (93% Coverage) Polyethylene Insulation • Blue PVC Jacket (Color Code: Clear, Blue) Style 2092 CM U-500 U-152.4 20.0 9.1 (7x28) 93% Shield (300V 60°C) CEC: 500 152.4 18.5 8.4 .038 ″ Coverage CM U-1000 U-304.8 39.0 17.7 TC 3.4 Ω/M′ 31.2Ω/km Plenum • FEP Teflon® Insulation • Blue FEP Teflon Jacket (Color Code: Clear, Blue) CMP 1000 304.8 38.0 17.3 (7x28) 93% Shield CEC: .038″ Coverage CMP FT6 TC 3.9 Ω/M′ 9.5Ω/M′ 12.8v/km 31.2Ω/km Suitable for Aerial applications when supported by a messenger. 78 Ohm • 20 AWG Stranded (7x28) .038″ Tinned Copper Conductors • Beldfoil® (100% Coverage) + TC Braid Shield (55% Coverage) Polyethylene Insulation • Blue Sunlight-resistant PVC Jacket (Color Code: Clear, Blue) Style 2464 CM CL2 U-500 U-152.4 19.5 8.9 (7x28) + 55% TC (300V 80°C) CEC: 500 152.4 18.0 8.2 .038 ″ Braid CM U-1000 U-304.8 38.0 17.2 TC 4.1 Ω/M′ 6000 ▲† 1828.7 234.0 106.1 31.0 Ω/km 10000 ▲† 3048.0 380.0 172.4 PMSHA P-7K-SC-182141* Allen Bradley P/N 1770-CD RG-22B/U • 95 Ohm • 18 AWG Stranded (7x26) .046″ Bare Copper Conductors • Double Tinned Copper Braid Shield (95% Coverage) Polyethylene Insulation • PE Inner Jacket • Black Non-contaminating PVC Outer Jacket (Color Code: Clear, Clear) VW-1 1000 304.8 121.0 54.9 (7x26) 95% Shield .046″ Coverage BC .9 Ω/M′ 6.6Ω/M′ 3.0Ω/km 21.5Ω/km RG-22B/U Type 1 conductor has tinned center strand. Non-contaminating PVC jacket. 100 Ohm • 20 AWG Stranded (7x28) .037″ One Tinned/One Bare Copper Conductors • Duofoil® + Double TC Braid Shield (95% Coverage) Polyethylene Insulation • Black High-density Polyethylene Jacket 80°C 1000 304.8 69.0 31.4 (7x28) 95% Shield 2000 609.6 134.0 60.9 .037 ″ Coverage (1) TC, 2.0 Ω/M′ (1) BC 6.6 Ω/km 9.5Ω/M′ 31.0Ω/km BC = Bare Copper • DCR = DC Resistance • FEP = Fluorinated Ethylene Propylene • PE = Polyethylene • TC = Tinned Copper Contact the Belden Customer Service Department for a Comprehensive Connector Cross Reference. 1-800-BELDEN-1. *Pennsylvania Department of Environmental Resources and United States Mine Safety and Health Administration Certification. †Final put-up may vary from length shown. ±10% for spools or reels, ±5% for UnReel ® cartons. COAXIAL CABLES 6.87 6 • Coaxial Cables For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com Computer and Instrumentation Cable

78 Ohm, 95 Ohm and 100 Ohm Twinax

1 .6 2.0 10 2.1 6.9 50 5.0 16.4 100 7.5 24.6 200 11.0 36.1 400 16.0 52.5 1 .6 2.0 10 2.1 6.9 50 5.0 16.4 100 7.5 24.6 200 11.0 36.1 400 16.0 52.5 1 .6 2.0 10 2.1 6.9 50 3.6 11.8 100 7.5 24.6 200 11.0 36.1 400 16.0 52.5 1 .4 1.3 10 1.1 3.6 50 2.5 8.2 100 4.1 13.5 200 6.4 21.0 400 10.2 33.5 For Plenum version of 9272, see 89272. CPE jacket optional. CPE jacket optional. CPE jacket optional. Shielding Materials Nom. DCR Nom. Imp. (Ω) Nominal Core OD Nominal OD Inch mm Inch mm Conductor (stranding) Diameter Nom. DCR Standard Unit WeightStandard Lengths Lbs. kgFt. m UL NEC/ C(UL) CEC Type Part No. MHz dB/ 100 Ft. dB/ 100m Nominal Attenuation Nominal Capacitance pF/mpF/Ft. Nom. Vel. of Prop. 1 .3 1.0 10 .9 3.0 20 1.3 4.3 50 2.1 6.9 100 3.0 9.8 400 6.3 20.7 Teflon is a DuPont trademark.

COAXIAL CABLES 6.88 For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com 100 Ohm • 20 AWG Stranded (7x28) .037″ One TC/One BC Conductor • Duofoil® (100% Coverage) + TC Braid Shield (86% Coverage) Polyethylene Insulation • Polyethylene Inner Jacket • Black PVC Outer Jacket CM CL2 U-500 U-152.4 33.0 15.0 (7x28) +86% CEC: 500 152.4 34.5 15.7 .037 ″ TC Braid CMG FT4 1000 304.8 68.0 30.9 (1) TC, 1.7 Ω/M′ 1640 500.0 111.5 50.7 (1) BC 5.7 Ω/km 2000 609.6 136.0 61.8 9.5 Ω/M′ 3280 1000.0 219.8 99.9 31.0 Ω/km IBM P/N 7362211 5000 1524.0 350.0 159.1 100 Ohm • 20 AWG Stranded (7x28) .037″ One TC/One BC Conductor • Duofoil (100% Coverage) + TC Braid Shield (85% Coverage) Plenum • FEP Insulation • Black FEP Jacket CMP 500 152.4 26.0 11.8 (7x28) +85% CEC: 1000 304.8 55.0 25.0 .037 ″ TC Braid CMP FT6 (1) TC, (1) BC 2.5 Ω/M′ 9.5Ω/M′ 8.2Ω/km 31.2Ω/km 124 Ohm • 25 AWG Stranded (7x33) .021″ Tinned Copper Conductors • Beldfoil® Shield (100% Coverage) • Stranded TC Drain Wire Polyethylene Insulation • Blue PVC Jacket (Color Code: Clear, Blue) Style 2092 CM 500 152.4 12.5 5.7 (7x33) 12.0 Ω/M′ CM 1000 304.8 28.0 12.7 TC 31.8Ω/M′ 104.3Ω/km 124 Ohm • 16 AWG Solid .051″ Bare Copper Conductors • Duofoil (100% Coverage) + Tinned Copper Braid Shield (90% Coverage) Foam Polyethylene Insulation • Black PVC Jacket (Color Code: Clear, Blue) Style 2448 CMX 1000 304.8 103.0 46.8 (solid) + 90% (30V 60°C) CEC: 2000 609.6 202.0 91.8 .051 ″ TC Braid VW-1 CMX BC 1.3 Ω/M′ 4.2Ω/M′ 4.3Ω/km 13.8Ω/km 150 Ohm • 22 AWG Stranded (19x34) .031″ Tinned Copper Conductors • Duofoil Shield (100% Coverage) • Stranded TC Drain Wire Datalene® Insulation • Black PVC Jacket (Color Code: Black, Yellow) Style 2668 CMX 500 152.4 23.0 10.4 (19x34) 6.3 Ω/M′ VW-1 CEC: TC CMX 14.0Ω/M′ 45.9Ω/km Plenum • Foam FEP Teflon Insulation • Black FEP Teflon Jacket (Color Code: Black, Yellow) CMP 500 152.4 28.0 12.7 (19x34) 6.3 Ω/M′ CEC: TC CMP FT6 14.0Ω/M′ 45.9Ω/km BC = Bare Copper • DCR = DC Resistance • FEP = Fluorinated Ethylene Propylene • TC = Tinned Copper Contact the Belden Customer Service Department for a Comprehensive Connector Cross Reference. 1-800-BELDEN-1. Teflon is a DuPont trademark. Computer and Instrumentation Cable

100 Ohm, 124 Ohm and 150 Ohm Twinax

1 .6 2.0 10 1.7 5.6 50 3.6 11.8 100 5.0 16.4 200 6.9 22.6 400 9.6 31.5 1. 2. 6 10 .7 2.3 50 1.8 5.9 100 2.9 9.5 200 4.1 13.5 400 6.2 20.3 1 .4 1.3 10 1.2 3.9 50 2.7 8.7 100 4.3 14.1 200 6.2 20.3 400 8.8 28.9 1 .4 1.3 10 1.2 3.9 50 2.7 8.7 100 4.3 14.1 200 6.2 20.3 400 8.8 28.9 Shorting Fold Shorting Fold Shielding Materials Nom. DCR Nom. Imp. (Ω) Nominal Core OD Nominal OD Inch mm Inch mm Conductor (stranding) Diameter Nom. DCR Standard Unit WeightStandard Lengths Lbs. kgFt. m UL NEC/ C(UL) CEC Type Part No. MHz dB/ 100 Ft. dB/ 100m Nominal Attenuation Nominal Capacitance pF/mpF/Ft. Nom. Vel. of Prop. CPE jacket optional. CPE jacket optional. For Plenum version of 9182, see 89182. Dual version: YR41609. CPE jacket optional. 1 .3 1.0 10 1.2 3.9 50 2.8 9.2 100 4.1 13.5 200 6.4 21.0 400 10.2 33.5 1 .3 1.0 10 1.2 3.9 50 2.8 9.2 100 4.1 13.5 200 6.4 21.0 300 8.4 27.6 400 10.2 33.5 For Plenum versions see 89207. CPE jacket optional.

COAXIAL CABLES 6.89 6 • Coaxial Cables For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com Computer and Instrumentation Cable Electrical Characteristics — Twinax Attenuation Attenuation (db/100 Ft) Frequency (MHz) 9859, 9272, 9463 9271 9182 9207, 9815 9250 9860 9851 1.0 2.0 3.0 4.0 5.0 6.0 7.0 12 3 4 5 6 8 1 0 2 0 3 0 4 0 5 0 Rise Time 0 to 50% Rise Time (Microseconds) 100 200 300 400 500 1000 2000 3000 4000 5000 Transmission Distance (Feet) 9271 9859, 9272, 9463 9860 9182 9851 9250, 9450, 9815 Bit Rate Bit Rate (Megabits/Sec.) 100 200 300 400 500 1000 2000 3000 4000 5000 Transmission Distance (Feet) 9851 9860 9250, 9207, 9815 9271 9859, 9272, 9463 9182 Transfer Impedance 9271 9851 9272, 9859 9815 9463 9207 9250 9860 0.1 1.0 10.0 100.0 1000.0 .1 1.0 10.0 50.0 (Milliohms/Meter) Frequency (MHz)

COAXIAL CABLES 6.90 For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com RG-58A/U Type • 20 AWG Stranded (7x28) .037″ Tinned Copper Conductor • Double Tinned Copper Braid Shield (96% Coverage) Polyethylene Insulation • Yellow PVC Jacket (Polyethylene Insulation between Braids) U-500 U-152.4 19.5 8.8 (7x28) 96% Shield 500 152.4 20.5 9.3 .037 ″ Coverage TC Inner: 9.5Ω/M′ 4.7Ω/M′ 31.0Ω/km 15.5 Ω/km Outer: 4.3Ω/M′ 14.1Ω/km RG-8/U Type • 11 AWG Stranded (7x19) .108″ Bare Copper Conductor • Double Bare Copper Braid Shield (96% Coverage) Foam Polyethylene Insulation • Black Polyethylene Jacket (Polyethylene Insulation between Braids) 1000 304.8 140.0 63.6 (7x19) 96% Shield .108″ Coverage BC Inner: 1.2Ω/M′ 1.2Ω/M′ 3.9Ω/km 3.9 Ω/km Outer: 2.1Ω/M′ 4.9Ω/km BC = Bare Copper • DCR = DC Resistance • TC = Tinned Copper Contact the Belden Customer Service Department for a Comprehensive Connector Cross Reference. 1-800-BELDEN-1. Computer and Instrumentation Cable

50 Ohm Triax

1 .5 1.6 10 1.5 4.9 50 3.3 10.8 100 4.9 16.1 200 7.2 23.6 400 12.0 39.4 700 18.0 57.1 900 22.0 72.2 1000 24.0 78.7 1. 1. 5 10 .5 1.7 50 1.2 3.9 100 1.8 5.9 200 2.7 8.9 400 4.2 13.8 700 5.8 19.0 900 6.7 22.0 1000 7.1 23.3 Shielding Materials Nom. DCR Nom. Imp. (Ω) Nominal Core OD Nominal OD Inch mm Inch mm Conductor (stranding) Diameter Nom. DCR Standard Unit WeightStandard Lengths Lbs. kgFt. m UL NEC/ C(UL) CEC Type Part No. MHz dB/ 100 Ft. dB/ 100m Nominal Attenuation Nominal Capacitance pF/mpF/Ft. Nom. Vel. of Prop.