9213B KISTLER | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 5
Technical content
for Mold Cavity Pressure with diameter 6 mm and M2,5 thread 9213B-000-556e-01.15 ©2005 ... 2015, Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland Tel. +41 52 224 11 11, Fax +41 52 224 14 14, info@kistler.com, www.kistler.com Kistler is a registered trademark of Kistler Holding AG. This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded. Type 9213B... Quartz force sensor for the measuring range from 0 ... 2 500 N or for measuring mold cavity pressure of up to >3 000 bar dur- ing injection molding of plastics.
- Case with M2,5 mounting thread
- Replaceable cable
- Available with singlewire technology
Description
The Type 9213B… miniature sensor offers high resolution and has extremely small dimensions and a rugged, welded case. The charge signal (pC = pico coulombs) output by the force sensor is converted in the Kistler charge amplifier or in a moni- toring unit into a proportional output voltage that is largely independent of the length of the sensor cable. The maximum possible output voltage from the standard amplifier is 10 V. In the most sensitive range this gives 1 N/V. The replaceable cables allow a wide choice of connecting cables, including the singlewire version. With singlewire technology an individual cable is shortened to the required length and connected to the connector using the proven cut and grip technique. With this arrangement the mold serves as a shield for signal transmis- sion. For multi cavity applications the sensor Type 9213B... is used without the singlewire connector Typ 1839. For 4-channel applications the Sensor Type 9213B... is mounted with the Multi-Channel Connector Type 1708... and for 8-channel ap- plications with the Multi-Channel Connector Type 1710... Application Thanks to its compactness the miniature force sensor is suit- able for dynamic and quasistatic force measurements. This is particularly useful for an application like injection molding, where space is critical and forces are high. Indirect pressure measurement is particularly suitable for molds with small cavi- ties or a large number of ejectors. The sensor is positioned under the ejector pin in the ejector plate, and measures the force curve by means of the ejector. This allows calculation of the actual mold cavity pressure. Technical Data Measuring range N 0 ... 2 500 Calibrated partial range N 0 ... 250 Overload N 3 000 Threshold mN 10 Sensitivity pC/N –4,4 Linearity, all ranges %FSO ≤±1 Operating temperature range °C –40 ... 200 Insulation resistance at 20 °C Ω ≥10 at 120 °C Ω ≥10
Miniature Force Sensor – for Mold Cavity Pressure with diameter 6 mm and M2,5 thread, Type 9213B... 9213B-000-556e-01.15 ©2005 ... 2015, Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland Tel. +41 52 224 11 11, Fax +41 52 224 14 14, info@kistler.com, www.kistler.com Kistler is a registered trademark of Kistler Holding AG. This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded. Fig. 1: Force Sensor Type 9213BE with cable and connector Fig. 2: Force Sensor Type 9213Bsp with cable and connector (standard length: 0,2/0,4/0,6/0,8/1,2 m) Force Sensor Type 9213BE Indirect measuring sensor with replaceable singlewire cable. Suitable for mounting as complete module in the ejector plate. Force Sensor Type 9213Bsp with standard lengths Indirect measuring sensor with replaceable coaxial connecting cable in lengths of 0,2/0,4/0,6/0,8/1,2 m or special lengths.
1 Force sensor 4 Cavity
2 Thrust washer 5 Ejector plate
3 Ejector pin
Fig. 3: Force sensor for indirect measurement of mold cavity pressure behind an ejector pin in the mold. Computation of Sensitivity for the Pressure Measurement The front face of the ejector pin must be taken into account when mounting the force sensor for pressure measurement. The nominal sensor sensitivity (pC/N) is converted into a cor - responding pressure sensitivity using the following formula. Calculated pressure sensitivity [pC/bar] = Nominal force sensitivity [pC/N] · area of ejector pin [mm ] · 0.1 The measuring range of the sensor must be taken into account when choosing the ejector pins. The larger the ejector pin area the higher the force on the sensor. The following table shows the calculated sensitivity with the nominal sensitivity of the Type 9213B... and the maximum pressure for a selection of ejector pins. Diameter ejector pin [mm] Sensivity [pC/bar] Maximum pressure [bar] 1,6 −0,88 >3 000 2 −1,38 2,5 −2,16 3 −3,11 4 −5,53 2 000 5 −8,64 1 250 Mounting The miniature force sensor has a precision ground face. The bearing surface of the ejector pin must also be finely machined, flat, rigid and exactly parallel. A hardened thrust washer must be used when mounting in a blind hole. The sensor can be mounted from below with an M2,5 screw. Once mounted the sensor must not have any preload. A clearance of 0.03mm is recommended. When using the singlewire technology, it must be ensured that the single-wire cable is kept in the ejector plate and that the Type 1839 connector is also mounted in this plate. When installing the connector in a different plate, electrical shielding by the mold must be ensured.
Miniature Force Sensor – for Mold Cavity Pressure with diameter 6 mm and M2,5 thread, Type 9213B... 9213B-000-556e-01.15 ©2005 ... 2015, Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland Tel. +41 52 224 11 11, Fax +41 52 224 14 14, info@kistler.com, www.kistler.com Kistler is a registered trademark of Kistler Holding AG. This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded. Fig 5: Sensor Type 9213B... with monitoring system CoMo Injection Type 2869B... Cable and Amplifier for Measuring Chains with Sensor Type 9213B... Type 2869B0xx Type 2869B2xx Type 2869B1xx Type 2869B3xx Cabel Type 1667B... with BNC connector Type 5159A Kabeltyp 1667B... mit BNC-Stecker 5159A Charge Amplifier Type 5159 Sensor 1Sensor 2Sensor 1 ... 4Sensor 3Sensor 4 PressurePower / Digital I/O / Analog Output
Miniature Force Sensor – for Mold Cavity Pressure with diameter 6 mm and M2,5 thread, Type 9213B... 9213B-000-556e-01.15 ©2005 ... 2015, Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland Tel. +41 52 224 11 11, Fax +41 52 224 14 14, info@kistler.com, www.kistler.com Kistler is a registered trademark of Kistler Holding AG. This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded. Mounting Examples Fig. 7: Mounting in retaining plateFig. 6: Sensor Type 9213 with thrust washer Type 9413 Fig. 9: Mounting sensor Type 9213 with ejector pinFig. 8: Mounting bore with thrust washer Type 9413 A A0,01 0,01A +0,1 010,2 0,012 2,8 6 H7 5,7 +0,1 0,3 D* = 0,5 mm larger than the diameter of the ejector head 5,2 * Sensor should not be preloaded. Consider this value as a minimum during construction and realisation of the mold. Depending on de- formation, it could be necessary to have a bigger gap. Check clear- ance before mounting the sensor. A 0,01 A 0,01A 10,5 0,012 2,8 0,05 0,08 6 H7 5,7 +0,1 0,3
Miniature Force Sensor – for Mold Cavity Pressure with diameter 6 mm and M2,5 thread, Type 9213B... 9213B-000-556e-01.15 ©2005 ... 2015, Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland Tel. +41 52 224 11 11, Fax +41 52 224 14 14, info@kistler.com, www.kistler.com Kistler is a registered trademark of Kistler Holding AG. This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded. Accessories Included Type/Art. No. Miniature force sensor Type 9213BE with singlewire cable
- Connector 1839
- Mounting plate 3.520.328
- Thrust washer 9413
- Identification plate 3.520.235 Miniature force sensor Type 9213Bsp (standard lengths: 0,2/0,4/0,6/0,8/1,2 m) with coaxial cable and connector
- Mounting plate 3.520.328
- Thrust washer 9413
- Identification plate 3.520.235 Optional Accessories Type/Art. No. High temperature extension cable Fluoropolymer with BNC connection
- Length 2 m 1667B2
- Length 5 m 1667B5
- Length 10 m 1667B10
- Special length 1667Bsp (between 0,5 m and 8 m) Singlewire cable, L = 1,5 m E Coaxial cable with special length, specify sp cable length L in m (Lmin = 0,1 m / Lmax = 5 m*) Sensor Type 9213BE without connector G Ordering Key Type 9213B Thickness: 1 mm Accessories Included * Standard lengths: 0,2/0,4/0,6/0,8/1,2 m High temperature extension cable with metal tubing and BNC connection
- Length 2 m 1661A2
- Length 5 m 1661A5
- Length 10 m 1661A10
- Special length 1661Asp (between 0,5 m and 8 m)
- 4-channel connector 1708
- 8-channel connector 1710