Piezoelectric load cells SlimLine Piezoelectric force transducers for tensile and compression forces of up to –20 ... 75 kN 9173C_003-420e-03.20 © 2020 Kistler Group, Eulachstraße 22, 8408 Winterthur, Switzerland products are protected by various intellectual property rights. For more details visit www.kistler.com. This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded. Type 9173C, 9174C, 9175C, 9176C, 9177C Piezoelectric load cells, also known as piezoelectric force trans- ducers, are preloaded and calibrated force sensors that are de- livered ready for mounting and for the measurement of tensile and compression forces. The integrated cable is protected by a fluoroelastomer sheath. SlimLine load cells are easy to install and are immediately ready for measurements.

  • Calibrated force transducer
  • Compact design, very small dimensions
  • Integrated, non-detachable cable with fluoroelastomer sheath
  • Plug coupling with mounting plate

Description

The preloaded piezoelectric force sensor can measure tensile and compression forces and produces an electric charge that is directly proportional to the applied force. This is converted to a proportional voltage by the charge amplifier, to be con- processed further as desired. The SlimLine sensor is installed in the load cell ground-isolated, thereby largely avoiding problems with ground loops. Application Thanks to its great stiffness, the compact SlimLine force trans- ducer is especially well suited for the measurement of rapidly changing tensile and compression forces. The elastic behavior of the measurement object is not noticeably influenced. Qua- sistatic measurements, i.e., measurements with relatively large time constants, are possible. You can find specific information on the integrated sensors in the sensor data sheet for Types Application examples

  • Force measurement in robotic systems
  • Monitoring on presses and punching, stamping and welding machines
  • Clamping processes, e.g., force transducer combined with hydraulic cylinder
  • Joining technology, e.g., insertion, press-fitting of assembly parts, etc. Technical data Sensitivity pC/N ≈–3.5 Linearity, incl. hysteresis % FS0 ±1 Threshold N ≤0.02 Insulation resistance Ω ≥10 Ground isolation MΩ ≥100 Temperature coefficient %/°C –0.02 Operating temperature range °C –20 ... 80 Cable length m 0.30 Typical calibration interval (dependent year 1 on of installation and application) Fz

Piezoelectric load cells SlimLine – piezoelectric force transducers for tensile and compression forces of up to –20 ... 75 kN, Type 9173C, 9174C, 9175C, 9176C, 9177C 9173C_003-420e-03.20 © 2020 Kistler Group, Eulachstraße 22, 8408 Winterthur, Switzerland products are protected by various intellectual property rights. For more details visit www.kistler.com. This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded. Installation Before installing the force transducer, make certain that the contact surfaces are cleanly machined, flat and stiff. The threads of the fastening elements should be perfectly aligned axially. For strain relief of the integrated cable, plug coupling Type 1729A2 should always be mounted at a suitable location on the measurement object. Plug coupling Type 1729A2, KIAG 10-32 neg. on both ends for cable relief B B 4,3 2,1min. dH 7 M Dh 6 1,5 dH 7 l=0,3m 1,5 A H 10-32UNF neg. hex1 hex2 Type Range: Tensile (–) Calibrated Overload Bending moment Dimensions in mm and compression (+) range (max., Fz = 0) hex1 hex2 kN kN kN N·m D D1 d H H1 A M M1 or WAF or WAF Installation types Installation of the SlimLine force transducer in platforms or dynamometers of extremely low overall height. Measurement of tensile and compression forces. Area of application, e.g., in combination with hydraulic cylinders. 0,02 0,02 Fz Fz Plastic adapter plate Force distributing cap Type 9416A3 ... 9416A7 Sensor Cap A B C D E F Type Type 9173C 9416A3 M4x0.7 14 11.3 6 130 WAF13 9174C 9416A4 M5x0.8 18 14.3 8 150 WAF16 9175C 9416A5 M6x1.0 22 16.3 9 200 WAF20 9176C 9416A6 M8x1.25 28 18.3 9 260 WAF26 9177C 9416A7 M10x1.5 34 20.3 9.8 320 WAF32 Ball

Piezoelectric load cells SlimLine – piezoelectric force transducers for tensile and compression forces of up to –20 ... 75 kN, Type 9173C, 9174C, 9175C, 9176C, 9177C 9173C_003-420e-03.20 © 2020 Kistler Group, Eulachstraße 22, 8408 Winterthur, Switzerland products are protected by various intellectual property rights. For more details visit www.kistler.com. This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded. Accessories Type

  • Force distributing cap 9416A3 ... 9416A7
  • Cable suitable for plug connection see data sheet KIAG 10-32 neg. Delivery scope Type
  • Load cell 1729A2 including plug coupling and plastic adapter plate Load cell SlimLine Measuring range –3 ... +12 kN 3 Measuring range –5 ... +20 kN 4 Measuring range –8 ... +30 kN 5 Measuring range –16 ... +60 kN 6 Measuring range –20 ... +75 kN 7 Ordering key Type 917 C Compatibilities of cables and charge amplifiers Feed-through cable Type 1729A Compatibility List of Cables and Charge Amplifiers Aktuelle Sprache: EN Choose language EN DAQ Datasheet Page 5030A 5039A 5073A… 5074A... 5877B… 5015A… 5018A… 5080A… 5165A… 5167A… KiDAQ Channels 1‐4 1‐4 1‐8 1,4 4,8 4, … ,52 Sensors min max 1957A… PFA, steel braiding 0.1 10 KIAG 10‐32 pos. KIAG 10‐32 pos. ✓ ‐‐ ✓ ‐‐‐‐‐‐‐ 1900A23A11.. KIAG 10‐32 pos. hex KIAG 10‐32 pos. hex ✓ ‐ ‐ ✓ ‐‐‐‐‐‐‐ 1900A21A110x KIAG 10‐32 pos. hex KIAG 10‐32 pos. hex ✓ ‐‐ ✓ ‐‐‐‐‐‐‐ 1983AD… FPM 0.1 5 ‐20…200°C IP68 KIAG 10‐32 pos. int. BNC pos. ‐ ✓✓ ‐ ✓✓✓✓✓✓✓ 1 screwed: IP65 2 welded: IP67 5030A 5039A 5073A… 5074A... 5877B… 5015A… 5018A… 5080A… 5165A… 5167A… KiDAQ Channels 1‐4 1‐4 1‐8 1,4 4,8 4, … ,52 min max 1637C Extension cable, PFA, Ø2mm 0.3 5 ‐55…200°C KIAG 10‐32 neg. KIAG 10‐32 pos. screwed Industrial Amplifier Laboratory Amplifier Cable Cable Properties Length [m] Temp. Range IEC/EN

60529 Connector Sensor Connector

9313AA... 93xA... ‐55…200°C Plug screwed IP65 IP40 IP53 IP20 IP40 IP65 IP65 IP60 IP67 Plug screwed IP65 PFA superflexible, drag chain proven 0.3 20 ‐40…200°C IP67 IP40 IP67 FPM flexible steel hose ‐55…200°C Plug welded1 IP67 IP40 IP65 IP65 0.4 20 ‐20…200°C IP40 IP67 IP40 Industrial Amplifier Laboratory Amplifier Cable/Adapter Cable Properties Length [m] Temp. Range IEC/EN ‐55…200°C IP65 IP65 IP53 IP20 IP40 IP65 IP65 IP60 IP67 screwed IP65 IP65 Adapter for cables with KIAG 10‐32 pos. int. ‐55…200°C IP40 Cable gland with KIAG 10‐32 pos. int. IP65 Compatibility List of Cables and Charge Amplifiers Aktuelle Sprache: EN Choose language EN DAQ Datasheet Page 5030A 5039A 5073A… 5074A... 5877B… 5015A… 5018A… 5080A… 5165A… 5167A… KiDAQ Channels 1‐4 1‐4 1‐8 1,4 4,8 4, … ,52 Sensors min max 1957A… PFA, steel braiding 0.1 10 KIAG 10‐32 pos. KIAG 10‐32 pos. ✓ ‐‐ ✓ ‐‐‐‐‐‐‐ 1900A23A11.. KIAG 10‐32 pos. hex KIAG 10‐32 pos. hex ✓ ‐ ‐ ✓ ‐‐‐‐‐‐‐ 1900A21A110x KIAG 10‐32 pos. hex KIAG 10‐32 pos. hex ✓ ‐‐ ✓ ‐‐‐‐‐‐‐ 1983AD… FPM 0.1 5 ‐20…200°C IP68 KIAG 10‐32 pos. int. BNC pos. ‐ ✓✓ ‐ ✓✓✓✓✓✓✓ 1 screwed: IP65 2 welded: IP67 5030A 5039A 5073A… 5074A... 5877B… 5015A… 5018A… 5080A… 5165A… 5167A… KiDAQ Channels 1‐4 1‐4 1‐8 1,4 4,8 4, … ,52 min max 1637C Extension cable, PFA, Ø2mm 0.3 5 ‐55…200°C KIAG 10‐32 neg. KIAG 10‐32 pos. screwed Industrial Amplifier Laboratory Amplifier Cable Cable Properties Length [m] Temp. Range IEC/EN 9313AA... 93xA... ‐55…200°C Plug screwed IP65 IP40 IP53 IP20 IP40 IP65 IP65 IP60 IP67 Plug screwed IP65 PFA superflexible, drag chain proven 0.3 20 ‐40…200°C IP67 IP40 IP67 FPM flexible steel hose ‐55…200°C Plug welded1 IP67 IP40 IP65 IP65 0.4 20 ‐20…200°C IP40 IP67 IP40 Industrial Amplifier Laboratory Amplifier Cable/Adapter Cable Properties Length [m] Temp. Range IEC/EN ‐55…200°C IP65 IP65 IP53 IP20 IP40 IP65 IP65 IP60 IP67 screwed IP65 IP65 Adapter for cables with KIAG 10‐32 pos. int. ‐55…200°C IP40 Cable gland with KIAG 10‐32 pos. int. IP65