Technical content
Piezoelectric force sensor kit SlimLine Piezoelectric force sensor kit 9130CA_003-419e-04.21 © 2020 ... 2021 Kistler Group, Eulachstraße 22, 8408 Winterthur, Switzerland products are protected by various intellectual property rights. For more details visit www.kistler.com. This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded. 9137CA... Ready-to-connect, compact measuring kit with integrated pie- zoelectric force sensors or piezoelectric load cells in the SlimLine format. 2, 3 or 4 of the ultra-flat quartz measuring load washers are grouped together in a fixed plug connection. The measure- ment of the total force (summation signal) or of the partial force (single signal per sensor) can be performed with an appropriate connecting cable. The SlimLine kit is supplied uncalibrated. The piezoelectric force sensors must be calibrated in situ after mounting.
- Flexible, compact installation in structures
- Total or single signals
- Cable length can be chosen for each sensor
- Sensors ground to the same height
Description
The Kit 913xCA consists of 2, 3 or 4 SlimLine force sensors that are grouped into a single, permanent, plug connection. The cable lengths of the sensors can be individually selected between 0.1 m and 2 m. The total force to be measured Fz acts on the sensors through the mounting or preloading elements. Each loaded sensor pro- duces an electrical charge that is proportional to its force com- ponent. The charge signals are fed out through electrodes and integrated cables. The individual sensor cables in the SlimLine kit are guided separately and inseparably to the corresponding pin positions of the 7-pin plug connection. With connecting cables Type 1971A or Type 1973A, the signals can be summed or individu- ally passed on to the charge amplifier as necessary. Application SlimLine sensors are particularly suitable for measuring rapidly changing forces thanks to their enormous rigidity. Measure- ments over several minutes are possible. The extremely com- pact design is especially convenient for installation in structures such as force plates, fitting strips and follow-on tools. The kit is used in industrial manufacturing processes where forces are monitored or measured. In combination with a ControlMoni- tor, the kit is ideally suited for quality control and monitoring in industrial series production. Application examples
- Monitoring of pressing forces, punching forces, etc.
- Monitoring of follow-on tools
- Measurement of large forces in force shunt mode
- Installation in dynamometers with small dimensions Fz Fig. 1: SlimLine kit Connecting cable 9.0 Technical data SlimLine SlimLine Range Overload kit Sensor (kN) (kN)
Piezoelectric force sensor kit SlimLine – kit with piezoelectric ring force transducers, 9130CA_003-419e-04.21 © 2020 ... 2021 Kistler Group, Eulachstraße 22, 8408 Winterthur, Switzerland products are protected by various intellectual property rights. For more details visit www.kistler.com. This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded. 10,1 3,2 BNC pos. L Connecting cable Connecting cable for total signal (summed) Type 1971A1_, plug connection: BNC pos. Connecting cable for single signals Type 1973A_1_, plug connection: KIAG 10-32 pos. Coupling Type 1721 is supplied Compatibilities of cables and charge amplifiers Z14705-107 1721 28.1.97 Sp Zeichn. Nr. Type Datum gezeichnet Ind. Coupling Type 1721 Kompatibilitäten von Kabeln und Ladungsverstärker 5030A 5039A 5073A… 5074A... 5877B… 5015A… 5018A… 5080A… 5165A… 5167A… KiDAQ Kanäle 1‐4 1‐4 1‐8 1,4 4,8 4, … ,52 min max 1971A3x PFA 0.1 20 Fischer KE102A014‐14 5030A 5039A 5073A… 5074A... 5877B… 5015A… 5018A… 5080A… 5165A… 5167A… KiDAQ Channels 1‐4 1‐4 1‐8 1,4 4,8 4, … ,52 min max 1971A3x PFA 0.1 20 Fischer KE102A014‐14 IP65 IP60 Industrie Verstärker Labor Verstärker Ausgangs‐ signal Kabel/ Adapter Kabeleigenschaften Länge [m] Temp. Bereich IEC/EN
60529 Stecker Sensor Stecker Verstärker
1 ‐55…200°C Stecker geschraubt IP65 Fischer 7‐pol IP40 zus. Kabel notwendig einzeln PFA, PUR Schutzschlauch ‐55…200°C IP65 Fischer 7‐pol IP65 IP40 IP40 IP20 IP20 IP20 IP67 IP53 IP20 IEC/EN 60529 IP65 Adapter für Kabel mit KIAG 10‐32 pos. int. ‐55…200°C IP65 IP40 geschraubtDurchführung für Kabel mit KIAG 10‐32 pos. int. IP65 Stecker geschraubt IP65 IP65 IP60 Industrial Amplifier Laboratory Amplifier Output Signal Cable/Adapt er Cable Properties Length [m] Temp. Range IEC/EN 60529 Connector Sensor Connector Amplifier sum 1 ‐55…200°C Plug screwed IP65 Fischer 7‐pol IP40 Plug screwed IP65 IP40 IP40 IP20 IP20 IP20 IP67 IP53 IP20 IEC/EN 60529 IP65 Adapter for cables with KIAG 10‐32 pos. int. ‐55…200°C IP65 IP40 screwe d Cable gland with KIAG 10‐32 pos. int. IP65 add. Cable needed separate PFA, PUR protection tube ‐55…200°C IP65 Fischer 7‐pol IP65 For detailed technical data, please refer to the data sheet or the user manual of the Type 913xC single sensors at www.kistler.com/force
Piezoelectric force sensor kit SlimLine – kit with piezoelectric ring force transducers, 9130CA_003-419e-04.21 © 2020 ... 2021 Kistler Group, Eulachstraße 22, 8408 Winterthur, Switzerland products are protected by various intellectual property rights. For more details visit www.kistler.com. This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded. Cable lengths Standard length, 3 m, BNC pos. 11 Cable length dependent on order, BNC pos. 19 Cable length dependent on order, 29 Mini Coax neg. Cable length dependent on order, TNC pos. 49 Cable length dependent on order, 59 KIAG 10-32 pos. Ordering key for connecting cables for total signal (summed) Type 1971A Optional accessories Type
- Preloading disk for SlimLine kit 9410A0 Type 9130CA...
- Preloading disk for SlimLine kit 9410A2 Type 9132CA...
- Preloading disk for SlimLine kit 9410A3 Type 9133CA...
- Preloading disk for SlimLine kit 9410A4 Type 9134CA...
- Preloading disk for SlimLine kit 9410A5 Type 9135CA...
- Preloading disk for SlimLine kit 9410A6 Type 9136CA...
- Preloading disk for SlimLine kit 9410A7 Type 9137CA... Measuring range Kit with SlimLine sensor Type 9130C... 0 Kit with SlimLine sensor Type 9132C... 2 Kit with SlimLine sensor Type 9133C... 3 Kit with SlimLine sensor Type 9134C... 4 Kit with SlimLine sensor Type 9135C... 5 Kit with SlimLine sensor Type 9136C... 6 Kit with SlimLine sensor Type 9137C... 7 Kit with 2 sensors 2 Kit with 3 sensors 3 Kit with 4 sensors 4 Specify the cable length for each sensor separately l = 0.1 ... 2 m Ordering key for the SlimLine kit Type 913 CA 9 For number of sensors 2 sensors 2 3 sensors 3 4 sensors 4 Connector type KIAG 10-32 positive 1 Cable lengths Standard length, 3 m 1 Cable length dependent on order 9 Ordering key for connecting cables for single signals Type 1973A