9124-410G MRV | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 4

Technical content

OptiSwitch® 9124-410G Carrier-Ethernet Packet-Optical Aggregation MRV OptiSwitch ® 9124-410G is an award-winning compact Carrier-Ethernet packet-optical aggregation platform for 1 st and 2nd mile optical FE, GigE and 10GE NGN infrastructure. OptiSwitch 9124-410G provides service providers with a full suite of carrier-grade Ethernet services along with high- availability, enhanced quality of services, security, Packet-WDM and Ethernet Operation, Administration and Maintenance (OAM) support. The uniqueness of a full suite of Carrier- Ethernet tools creates flexible service awareness and rigid SLAs to enable converged Triple Play, Business and Mobile backhaul services. OptiSwitch® Metro Ethernet solution meets IEEE, ITU, IETF and MEF standards, offering complete control to simplify deployment and management, while maintaining full interoperability and guaranteed Service Level Agreements (SLAs). MRV Unified Master-OS® control plane for Metro-E services - Simplifies operation and management integration with OSS MEF CE2.0 compliant services Non-blocking hardware architecture - 24 x GigE and 4 x 10GE (LAN/WAN) o FE, GigE, 2,5G and 10GE Services Outstanding variety for Optical Layer 1 & Layer 2 VPN Services - EPL X-connect, E-Line, E-Tree and E-LAN - Point-to-point, point-to-multipoint and multipoint-to- multipoint - Any-to-any transparent cross-connect - eROADM services Flexible UNI/NNI interfaces - 100FX/1000FX/2000FX and 10GE - Same device for all aggregation scenarios - Support for jumbo frames on all ports Advanced traffic management with line rate performance - Classification, policing, metering, marking per-flow QoS - Low-latency and precise service rates Unmatched flexibility of Ethernet Virtual Circuits - Selective Q-in-Q and VLAN translation End-to-end Ethernet service OAM to monitor SLAs - Standard compliant – CFM IEEE802.1ag / PM ITU-T Y.1731 - RFC2544 throughput measurements - IP SLA measurements - EFM link OAM – IEEE802.3ah - Simplifies, monitors and troubleshoots services/applications Protection mechanism - ELPS G.8031 and ERPS G.8032 - Link Protection 1:1 (LOS) and n+1 (LAG) - Sub 50ms SONET-like recovery and deterministic SLA Multicasting service for IP-TV Triple Play Compact 2RU form factor for space saving Hot-swap fully redundant power supplies and fans Excellent price/performance for fast ROI Product highlights Supports a wide range of mission-critical revenue generating GigE and 10GE services - Triple-Play IPTV, NGN Voice services - Business services and mobile backhaul Lambda services – Fiber optimization via C/DWDM integration

Applications

Triple Play Services xWDM Services OptiSwitch 9124-410G PS2 PS1 CONSOLE EIA-232 L A 10GE-XFP L A 10GE-XFP L A 10GE-XFP L A 10GE-XFP TMP FANMGT RST MGT ETH 2423 22 24 21 2321 1413 1615 1817 2019 2221 2423 ADD DROP EXP COM MS9-OADM8 IN OUT EM9005 PS/ACEM9005 PS/DC CAUTION This assembly contains electronically sensitivecomponents 47 49 51 53 55 57 59 61 47 49 51 53 55 57 59 61 OptiSwitch 9124-410G PS2 PS1 CONSOLE EIA-232 L A 10GE-XFP L A 10GE-XFP LA 10GE-XFP L A 10GE-XFP TMP FANMGT RST MGT ETH 2423 22 24 21 232 1413 1615 1817 2019 2221 2423 ADD DROP EXP COM MS9-OADM8 IN OUT EM9005 PS/ACEM9005 PS/DC CAUTION This assembly contains electronically sensitive components 47 49 51 53 55 57 59 61 47 49 51 53 55 57 59 61 OptiSwitch 9124-410G PS2 PS1 CONSOLE EIA-232 L A 10GE-XFP L A 10GE-XFP L A 10GE-XFP L A 10GE-XFP TMP FANMGT RST MGT ETH 2423 22 24 21 2321 1413 1615 1817 2019 2221 2423 ADD DROP EXP COM MS9-OADM8 IN OUT EM9005 PS/ACEM9005 PS/DC CAUTION This assembly contains electronically sensitive components 47 49 51 53 55 57 59 61 47 49 51 53 55 57 59 61 Optical Packet Switched Network BSC/RNC/S-GW 2G/2.5G BTS End - to - end Service OAM Node B OS904-MBH MGT PWR CONSOLE EIA-232 MGT ETH L A 1 21 2 3 4 ST1 ST2 ToD 1PPS 50Ω 75Ω 50Ω 75Ω CLK OUT CLK IN CLK DS1/E1 LOS OS904-MBH MGT PWR CONSOLE EIA-232 MGT ETH L A 1 21 2 3 4 ST1 ST2 ToD 1PPS 50Ω 75Ω 50Ω 75Ω CLK OUT CLK IN CLK DS1/E1 LOS OS904-MBH MGT PWR CONSOLE EIA-232 MGT ETH L A 1 21 2 3 4 ST1 ST2 ToD 1PPS 50Ω 75Ω 50Ω 75Ω CLK OUT CLK IN CLK DS1/E1 LOS OptiSwitch 9124-410G PS2 PS1 CONSOLE EIA-232 L A 10GE-XFP L A 10GE-XFP L A 10GE-XFP L A 10GE-XFP TMP FANMGT RST MGT ETH 2423 22 24 21 232 1413 1615 1817 2019 2221 2423 ADD DROP EXP COM MS9-OADM8 IN OUT EM9005 PS/ACEM9005 PS/DC CAUTION This assembly contains electronically sensitive components 47 49 51 53 55 57 59 61 47 49 51 53 55 57 59 61 OptiSwitch 9124-410G PS2 PS1 CONSOLE EIA-232 L A 10GE-XFP L A 10GE-XFP L A 10GE-XFP L A 10GE-XFP TMP FANMGT RST MGT ETH 2423 22 24 21 232 1413 1615 1817 2019 2221 2423 ADD DROP EXP COM MS9-OADM8 IN OUT EM9005 PS/ACEM9005 PS/DC CAUTION This assembly contains electronically sensitive components 47 49 51 53 55 57 59 61 47 49 51 53 55 57 59 61 Node B Not sure which solution best fits your needs? Visit www.mrv.com or e-mail us at sales@mrv.com OS9124 - 410G

Port numbering Service Interface Options Ports 1-16 10/100/1000BaseT - RJ45 SFPs (SFP-GA-R or SFP-GC-R) 100BaseFX - SGMII 100FX SFPs 1000BaseFX - standard GigE SFPs 2.5Gbps - 2000BaseFX - Standard multi-rate SFPs Ports 17-18 10/100/1000BaseT - RJ45 SFPs (SFP-GA-R or SFP-GC-R) 100BaseFX - SGMII 100FX SFPs 1000BaseFX - standard GigE SFPs Port 19-20 100BaseFX - Standard 100FX SFPs 1000BaseFX - Standard GigE SFPs Port 21-24 Tri-mode built-in options Built-in 10/100/1000BaseT 100BaseFX - Standard 100FX SFPs 1000BaseFX - standard GigE SFPs Port 25-28 10GE LAN/WAN(STM-64/OC192) PHY - Standard XFPs Multi-Service slot WDM & CES Services ITU-T G.694.1 Standard (DWDM) ITU-T G.694.2 Standard (CWDM) OADMs, MUX/DEMUX E1/T1 CES STM-1/OC3 CES Features and Solution Benefits OS9124-410G platform is a high-performance system with non-blocking hardware and software architecture engineered for deployment in new and demanding packet-optical network environments to support the provider’s value-added services offering. By integrating packet switching and aggregation with WDM transport, the OS9124-410G enables increased efficiencies in bandwidth utilization, optimizing interface and simplifying the network by eliminating the need for dedicated hardware. For service providers who build next-generation optical networks, the consolidation of WDM services with intelligent traffic forwarding on the same platform offers significant costs savings in capital expenditure. Multipurpose Service Interfaces The platform offers a unique combination of features and optical interfaces that enable easy and flexible field configurations while making it ideal for maintenance and inventory. The integration of CWDM / DWDM SFP / XFP eliminates the need for a transponder in the network, and offers better fiber optimization along physical services separation with dedicated Gigabit or 10G rates for premium optical services with the same concept of legacy “leased-line” services.

  • All Interfaces can be configured as UNI / NNI to enable access to edge and intra-network services
  • 100FX and 1000FX interfaces can be muxponded over 10GE interface at dedicated wavelength
  • Hot Swappable XFP and SFP pluggable optics to insure diverse distance, cost and performance
  • XFP slots support distances from short to long haul and DWDM pluggable optics
  • SFP slots support distances from short to long haul, single strand and CWDM and DWDM optics
  • 10GE interfaces software configurable for 10GE LAN or WAN OC192/STM-64
  • All SFP and XFP interfaces enabled for remote Optical Level monitoring and alarm thresholds
  • Built-in RJ45 electrical interfaces enabled for remote copper-TDR cable diagnostics End-to-end Service ProVisioning and Operation, Administration & Maintenance* MRV’s Pro-Vision® software enables complete easy-to-use GUI tool to Provision and activation management for packet-optical services. Network monitoring supported by real-time sampling, or historical performance reporting for customer SLA. The system is carrier-grade UNIX-based software that supports full FCAPS industry standards to insure simplified interoperability with existing Operation Support Systems (OSS) and 3rd party Network Management Systems (NMS) through northbound protocols, such as CORBA, SNMP , TL1,HTTP and XML. End-to-end service provisioning and activation across network infrastructure* * Denotes future software release Packet WDM
  • UNI type 1 and Type 2 (MEF21)
  • External-NNI & Internal-NNI
  • EPL, E-Line, E-Tree & E-LAN – MEF9
  • EPL, E-Line, E-Tree & E-LAN Traffic Mgm. – MEF14
  • OAM Implementation Agreement (IA) – MEF17
  • All interfaces can be configured as UNI / ENNI Packet Switching Services
  • 200G (Full-duplex) non-blocking wire-speed architecture
  • Configurable jumbo frames per port / EVC
  • Packet buffer management
  • IEEE802.1Q and IEEE802.1ad provider bridges - 4K active VLANs / EVCs - Selective Q-in-Q stacking per ACL criteria - Configurable Ethertype values - Private VLAN
  • Transparent cross-connect mode - Per System, per port or per EVC non-learning mode
  • Learning table limit per VLAN/port
  • Layer 2 control protocols tunneling
  • UNI protected ports / Layer 1 filtering Packet ring and Link protection Services
  • Sub 50 ms ring and dual–homed topologies
  • ELPS G.8031 and ERPS G.8032
  • MSTP IEEE802.1s
  • Link Aggregation (LAG n+1) – static and LACP - Load balancing based on L2-3-4 headers
  • Link level 1:1 Loss of Signal (LOS) protection
  • CFM (OAM) messages for fault detection and link fallback
  • Bi-directional Link Fault Reflection
  • Link flap protection and damping
  • Unidirectional Link Detection Multicast and IP Services*
  • Wire speed multicast replication
  • IGMP v1,v2 snooping , proxy and fast leave
  • Multicast VLAN Registration (MVR) protocol*
  • Multicast routing PIM-SM*
  • Wire-speed IPv4 / IPv6* packet routing - RIP , OSPF , IS-IS, BGP-4, VRRP - Secondary interfaces - DHCP server/client/relay Layer 2.5 Services*
  • Ethernet over MPLS pseudowire with Traffic Engineering*
  • H-VPLS dual-homed spoke MTU-s (LER)* - LDP , RSVP-TE, OSPF-TE, ISIS-TE, CSPF*
  • MPLS-Transport Profile – MPLS-TP* Availability
  • 1:1 Hot-swappable dual redundant power – AC/DC mix
  • Hot-swappable fans and filter
  • Temperature sensor for environmental alerts
  • Dual image & rollback processes
  • Modular control plane - Master-OS™ Traffic Management
  • Inbound & Outbound traffic management per flow/EVC
  • In-service circuit parameters changes (hitless ACL)
  • Dual-rate 3 color rate limit per flow or aggregate - Granular CIR/EIR rates up to 10GE
  • Classification by any L2-3-4 criteria and mix - Physical port, MAC, Ethertype, VLAN, IP/TCP/UDP
  • IEEE 802.1p (VPT), DiffServ (IPv4 & IPv6 TC)
  • Marking/remarking profiles between layers - 802.1p, DSCP & MPLS EXP
  • 8 hardware queues per port & configurable SL
  • Per flow SLA metrics - per UNI, CoS, EVC, control protocols - 16,000 counters Security
  • Wire-speed ACLs on L2-3-4 headers - Up to 8K rules - Ingress and Egress ACLs - Multiple actions in single ACL
  • CPU Denial-of-Service protection
  • MAC filters and MAC limit per port/per VLAN
  • UNI Broadcast/Multicast/Unicast rate control
  • Flood limit of OAM frames
  • ARP rate control
  • DHCP option 82 & option 60
  • ACL for management sessions from NOC
  • VACM – View-based Access Control Model Management & Diagnostics Tools
  • Industry Standard CLI
  • Out-of-band management - EIA-232 console
  • Out-of-band Ethernet management - Dedicated ETH port
  • Telnet, SSH v2, SNMPv3, RMON (4 groups)
  • Port mirroring - ingress & egress traffic to analyzer port / VLAN
  • Remote service/flow mirroring per ACL
  • Ping, Trace route, DNS lookup, TCP dump (built-in sniffer)
  • Management ACL for trusted connections (Telnet/SSH/SNMP)
  • Hierarchical Administration policy
  • RADIUS / TACACS+ AAA for management sessions
  • Configuration load/save via FTP , Secure Copy (SCP)
  • NTP - Network Time Protocol
  • Internal / Remote Syslog
  • Scripting tool for macro configurations & maintenance
  • Action scheduler for automated rules (time/day/cycle)
  • Remote auto-configuration - DHCP server/client/relay
  • IPv6 management* Standard Operation, Administration & Maintenance
  • End-to-end Service OAM IEEE802.1ag - Connectivity Fault Management per service MEP/MIP - In-service EVC loopbacks, Linktrace & continuity check
  • End-to-end Performance Measurement ITU-T Y.1731 & IP SLA - Per service Jitter, Latency & Loss - nano sec’ precision - RFC2544 troughput measurements for service baseline - Scalable up to 64 measurements flows
  • EFM Link OAM - IEEE802.3ah - discovery, port-loopback, remote failure indication
  • Optical signal level monitoring (SFP SFF-8472)
  • Copper cable diagnostics on RJ45 ports
  • Remote failure notification / reflection *Future Master-OS™ Software release

Rev.3 10 -13 Copyright ©2009 MRV Communications, Inc. All Rights Reserved. P/N Description OS9124-410G OptiSwitch® 9000 Series multi-layer platform with 16 SFP (100FX/1000FX/2000FX) + 4 SFP (1000FX) + 4 x Tri-Mode RJ45 10/100/1000BaseT or SFP (100FX/1000FX) + 4 x 10GE (LAN/WAN) + Optional Multi-Service Slot (AC/DC Power supplies should be ordered separately) Hot-swappable power supplies for OS9000 series EM9005-PS/AC AC power supply for the OptiSwitch® 9000 Series (90-240V AC) EM9005-PS/DC DC power supply for the OptiSwitch® 9000 Series (-48V DC) Accessories MS9000-Blank Blank panel for multi-service slot EM9005-Blank Blank panel for Power Supply. EM9005-BR-2-C 23” mounting bracket MS9000-FG-A Fiber guard tray for OS9124-410G model EM9005-FAN-T Spare part- Fan tray for OS9124-410G model Master-OS™ - MPLS LER Software Upgrade Package for OS9124-410G SW-UPG-91MPLS* Enhanced software upgrade package for OptiSwitch® 9124-410G (Master-OS: Label Edge Router MPLS spoke VC - LDP , RSVP-TE, CR-LDP , OSPF-TE, CSPF) * For ordering codes of SFP/XFP and SGMII Pluggable optics, please refer to MRV’s web site OS9000 - CWDM fiber optimization modules O9ADCxx 1 CWDM wavelengths DF OADM module for OS9000 O9ADCxxyy 2 CWDM wavelengths DF OADM module for OS9000 O9ADCxxyyzz 3 CWDM wavelengths DF OADM module for OS9000 O9ADCxxyyzzww 4 CWDM wavelengths DF OADM module for OS9000 O9ADCDxx 1 CWDM wavelengths DF Dual Sided OADM module for OS9000 O9ADCDxxyy 2 CWDM wavelengths DF Dual Sided OADM module for OS9000 O9ADCDxxyyzz 3 CWDM wavelengths DF Dual Sided OADM module for OS9000 O9ADCDxxyyzzww 4 CWDM wavelengths DF Dual Sided OADM module for OS9000 O9ADCDSxx 1 CWDM wavelengths SF Dual Sided OADM module for OS9000 O9ADCDSxxyy 2 CWDM wavelengths SF Dual Sided OADM module for OS9000 O9ADCDSxxyyzz 3 CWDM wavelengths SF Dual Sided OADM module for OS9000 O9ADCDSxxyyzzww 4 CWDM wavelengths SF Dual Sided OADM module for OS9000 O9-Mux/Demux8 8 wavelengths CWDM Multiplexer/Demultiplexer module for OS9000 OS9000 - DWDM fiber optimization modules O9ADDxx 1 DWDM wavelengths DF Dual Sided OADM module for OS9000 O9ADDxxyy 2 DWDM wavelengths DF OADM module for OS9000 O9ADDxxyyzz 3 DWDM wavelengths DF OADM module for OS9000 O9ADDxxyyzzww 4 DWDM wavelengths DF OADM module for OS9000 O9ADDDxx 1 DWDM wavelengths DF Dual Sided OADM module for OS9000 O9ADDDxxyy 2 DWDM wavelengths DF Dual Sided OADM module for OS9000 O9ADDDxxyyzz 3 DWDM wavelengths DF Dual Sided OADM module for OS9000 O9ADDDxxyyzzww 3 DWDM wavelengths DF Dual Sided OADM module for OS9000 O9ADDDSxx 1 DWDM wavelengths SF Dual Sided OADM module for OS9000 O9ADDDSxxyy 2 DWDM wavelengths SF Dual Sided OADM module for OS9000 O9ADDDSxxyyzz 3 DWDM wavelengths SF Dual Sided OADM module for OS9000 O9ADDDSxxyyzzww 4 DWDM wavelengths SF Dual Sided OADM module for OS9000 O9-Mux/Demux8DB 8 wavelengths DWDM Multiplexer/Demultiplexer (ch#43 to ch#57) module for OS9000 O9-Mux/Demux8DR 8 wavelengths DWDM Multiplexer/Demultiplexer (ch#21 to ch#35) module for OS9000 Technical Specifications Regulatory compliance FCC Part 15 (Class A); EMC Directive: Emission (Class A) and Immunity; LVD Directive: Electrical Safety; CE Marking; TUV-R mark (Canada, USA); GOST; RoHS Directive, REACH SVHC, WEEE Directive; ETSI, NEBS Level 3 Certified , C-Tick. Operating Temperature 0 to 50 oC (32 to 122 oF) - Short term operation 0 to 65 oC (32 to 149 oF) Storage Temperature -40 to +70 oC (-40 to 158 oF) Humidity 10% to 85% non-condensing Diagnostic LEDs Power, System RST, Temperature, FAN, Management , PS Online/Active /Alarm , Ports: Link, activity, MGT Rack Mounting 19 “ or 23” racks , compact 2 RU height Maintainability Front facing system configuration: Eliminates the need to dismount the system for maintenance or installation of new hardware following initial installation Back-to-back installation in Telco racks: Doubling the ‘port-per-rack’ density. Performance Non-blocking 200G (full-duplex) architecture Full-wire packet forwarding on all ports 95M pps Physical dimensions WxDxH (mm/inch) Weight (kg. /lbs.) 5 Kg/11 lbs (fully loaded with 2 PS 7Kg /15.43lbs) MTBF HRS @25C /77F 245,104 Power Specifications (AC/DC)Hot swappable dual redundant Power Supplies AC Input Voltage Line frequencies 50-60Hz DC Input Voltage Options Power consumption(W) Min. Max. 90-240 VAC -48VDC (-36VDC to -72VDC) 100W min 135W max Hot swappable fans Single Tray – field replaceable Side-to-side airflow BTU per hour (min/max) 341 / 460

Ordering Information