HFZ16V-100 KG | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 5
Technical content
HFZ16V-100_EN Rev 1.0 1 A HFZ16V-100 HIGH VOLTAGE DC RELAY
- 100A, 900Vdc - 1 Form A Relay
- 2.2kVac dielectric strength between coil and contacts
- Different control coil voltages: 12, 24, 8 ~ 36Vdc
- Outline Dimensions: (46.3x41.7x62.2) mm
- Dimensions with flanges: (54.5x41.7x62.2) mm
- Screw load terminals (Polarity independent)
- Mounting flanges for easy installation
- RoHS compliant materials and processes
- Epoxy sealed contacts for use in hazardous environments Contact Data Characteristics Rated Load 100A Insulation resistance 1,000MΩ (at 1000 Vdc) Contact form 1 Form A Dielectric strength: Contact material Cu Alloy Coil to contact 2.2kVac for 1 min. Contact resistance* ≤0.5mΩ (@ 6Vdc/20A) Across open contacts 2.2kVac for 1 min. Max. switching voltage 900Vdc Dielectric creepage Max. switching current 1000A @ 320Vdc (1 op) Ambient temperature -40°C to +85°C Set time ≤ 30ms Ambient humidity 5% - 95% RH Reset time ≤ 10ms Vibration 10 Hz to 500 Hz / 98ms2 Bounce time ≤ 5ms Shock resistance: Electrical endurance 10,000 Cycles † Functional 196 m/s2 Mechanical endurance 1,000,000 Cycles Termination: Coil power consumption Approximately 6W Coil termination Wired or Connector Load termination Screw Terminal Unit weight Approximately 225g * Typical value for Initial Contact Resistance: Using a sample quantity of at least 20 units, take the average value from 5 continuous measurements from each sample. † Rating at 450Vdc / 100A
HFZ16V-100_EN Rev 1.0 2 A ‡ Test Conditions: 1V @ 40°C. Diameter cable used: 35mm2 Coil Resistance (Ω±10%) at 23° Nominal Coil Voltage Pick-up Voltage Drop-out Voltage Coil Resistance 12Vdc ≤9Vdc ≥1Vdc 26Ω 24Vdc ≤18Vdc ≥2Vdc 96Ω 8 ~ 36Vdc 7 ~ 8Vdc 5 ~ 6Vdc 4.7Ω
Ordering Information
HFZ16 ■ - 100 /900 - ■ - SH S ■ 5 ■ -1 XX Type Application V : Vehicle Nil : New Energy Power Control Series Code 100 : 100A Load Voltage 900 : 900Vdc Coil Voltage 12 : 12Vdc 24 : 24Vdc B : 8-36Vdc Contact Type SH : 1 Form A Contact Material S : Silver Plated Coil Termination L : Wire leads B : Wire leads with connector Load Terminal 5 : Screw Terminal Coil Power draw Nil : Standard P : Energy efficient type Coil Characteristics 1 : Single Coil Special Code X : Customer Customization Electrical Endurance‡ Current Duration 100A Continuous 150A 15 min 200A 3 min 300A 30 s
HFZ16V-100_EN Rev 1.0 3 A Dimensional Drawings § (Unit: mm) § Load terminal torque: 3.5 – 4.5Nm; Mounting Flange torque: 2 – 3.5Nm Coil Wire specifications: Style: UL3398; Diameter: 20AWG; Length: 300mm
HFZ16V-100_EN Rev 1.0 4 A Connector Manufacturer : Molex, Part number : 4364 Series†† †† Connectors are optional parts Wiring Diagrams Single Coil 1. A1 & A2 are load terminals ‡‡ §§ 2. 1 & 2 are coil terminals * ‡‡ Relays ship with bolts for load terminals §§ Load terminals are polarity independent * Coil wires are black and polarity independent Relay
HFZ16V-100_EN Rev 1.0 5 A Application Notes 1. To maintain the relay in its closed state, the coil voltage should reach the stated pick-up voltage. 2. For definitions of terms used in this data sheet, see glossary at www.kgtechnologies.net. Disclaimer: This data sheet is for reference only. All specifications are subject to change without prior notice. KG Technologies, Inc. cannot predict every possible application for our relays. While we do our best to make our relays as versatile as possible, we highly recommend contacting our engineering team if you have any questions. KG Technologies, Inc. is not responsible for malfunctioning relays when operated outside the specified parameters given in this data sheet.