HFZ16V-100P_EN Rev 1.0 1 A HFZ16V-100P HIGH VOLTAGE DC RELAY
- 100A, 900Vdc - 1 Form A Relay
- 2.2kVac dielectric strength between coil and contacts
- Different control coil voltages: 12, 24Vdc
- Outline Dimensions: (40.3x40.3x60.3) mm
- Dimensions with flanges: (46.3x40.3x60.3) mm
- Screw load terminals (Polarity dependent)
- Auxiliary Contact options (1 Form A/B)
- Mounting flanges for easy installation
- RoHS compliant materials and processes
- Epoxy sealed contacts for use in hazardous environments Contact Data Characteristics Rated Load 100A Insulation resistance 1,000MΩ (at 1000 Vdc) Contact form 1 Form A Dielectric strength: Contact material Cu Alloy Coil to contact 2.2kVac for 1 min. Contact resistance* ≤0.5mΩ (@ 20A) Across open contacts 2.2kVac for 1 min. Max. switching voltage 900Vdc Dielectric creepage Max. switching current 1000A @ 320Vdc (1 op) Ambient temperature -40°C to +85°C Set time ≤30ms Ambient humidity 5% - 95% RH Reset time ≤10ms Vibration 10-500Hz / 98ms2 Bounce time ≤5ms Shock resistance: Electrical endurance 10,000 cycles †‡ Functional 196 m/s2 Mechanical endurance 1,000,000 cycles Termination: Coil power consumption Approximately 6W § Coil termination Wired or Connector Load termination Screw Terminal Unit weight Approximately 220g * Typical value for Initial Contact Resistance: Using a sample quantity of at least 20 units, take the average value from 5 continuous measurements from each sample † Rating at: 450Vdc / 100A @ 23°C ‡ 1,000 Cycles at 750Vdc / 100A @ 23°C § Rating at: 12Vdc / 5.5W; 24Vdc / 6W
HFZ16V-100P_EN Rev 1.0 2 A ** Testing Conditions 1V @ 40°C. Diameter cable used: 35mm2
Ordering Information
Application V : Vehicle Nil : New Energy Power Series Code 100 : 100A Load Polarity Nil : None P : Polarity dependent Load Voltage 900 : 900Vdc Coil Voltage 12 : 12Vdc 24 : 24Vdc Contact Type SH : 1 Form A Contact Material S : Silver Plated Aux Contact Form Nil : No Auxiliary contact A : Normally Open Auxiliary contact B : Normally Closed Auxiliary contact Coil Termination L : Wire B : Wire & Connector Load Termination 5 : Screw terminals Installation type Nil : Vertical Y : Horizontal Shell Structure E : Simplified shell structure Coil Feature 1 : Single Coil Characteristics X : Customer customization Electrical Endurance** Current Duration 100A Continuous 150A 15 min 200A 3 min 300A 30 s Coil Resistance (Ω±10%) at 23° Nominal Coil Voltage Pick-up Voltage Drop-out Voltage Coil Resistance 12Vdc ≤9Vdc ≥1Vdc 26Ω 24Vdc ≤18Vdc ≥2Vdc 96Ω
HFZ16V-100P_EN Rev 1.0 3 A VERTICAL INSTALLATION MODEL (HFZ16■-100■/-900-■-SH S ■ ■ 5 E -1 X) HORIZONTAL INSTALLATION MODEL (HFZ16■-100■/-900-■-SH S ■ ■ 5 Y E -1 X) †† Load terminal torque: 3.5 – 4.5Nm; Mounting Flange torque: 2 – 3.5Nm ‡‡ Coil Wire specifications: Style: UL3398; Diameter: 20AWG; Length: 300mm Dimensional Drawings †† ‡‡ (Unit: mm)
HFZ16V-100P_EN Rev 1.0 4 A Connector Manufacturer : Molex, Part number : 4364 Series§§ §§ Connectors are optional parts Wiring Diagrams 1. A1+ & A2- are load terminals * ††† 2. 1 & 2 are coil terminals ‡‡‡ 3. 3, 4 & 5 are auxiliary terminals §§§ * Relays ship with bolts for load terminals ††† Depending on model, load terminals may be polarity dependent ‡‡‡ Coil wires are black and polarity independent §§§ Auxiliary wires are grey **** Auxiliary terminals are electrically isolated from load terminals and are polarity independent Relay
HFZ16V-100P_EN Rev 1.0 5 A Disclaimer: This data sheet is for reference only. All specifi cations are subject to change without prior notice. KG Technologies, Inc. cannot predict every possible application for our relays. While we do our best to make our relays as versatile as possible, we highly recommend contacting our engineering team if you have any questions. KG Technologies, Inc. is not responsible for malfunctioning relays when operated outside the specified parameters given in this data sheet. Application Notes 1. To maintain the relay in its closed state, the coil voltage should reach the stated pick-up voltage. 2. For definitions of terms used in this data sheet, see glossary at www.kgtechnologies.net.