Features
ˎ25A miniature general purpose Power Relay. ˎWith or without quick terminal & PCB terminal. ˎCSA/CUS, TUV,UL/CUL approved. ˎDesigned for compressor load switching application and office equipment of motor control or lamp load switching. Terminal style Contact form Designation WP (Quick terminal & PCB terminal) SPNO 891WP-1A-C P (PCB terminal) SPNO 891P-1A-C
891 WP - 1A - - C
- 891 -- Basic series designation 4. Blank -- Standard type F -- Class F 2. P -- PCB terminal WP -- Quick terminal & PCB terminal 5. C -- Flux tight 3. 1A -- Single pole normally open Resistive load 25A 250VAC Inductive load / Inrush 80A 240VAC cos φ0.7 Compressor load Steady state 20A 240VAC cosφ0.9 ˎComplies with RoHS-Directive 2011/65/EU. 6. -- Coil voltage (please refer to the coil rating data for the availability) ˎOptional for explosion-proof version. Max. switching current Max. switching voltage Max. switching capacity 6250VA 277VAC 25A Coil Rating (DC) Ratedġ Rated current ġ Coil resistanceġ Max. continuousġ Pick upġ Drop outġ Power consumptionġ voltageġ ±10 % at 23°Cġ ±10 % at 23°Cġ voltageġ voltage(Max.)ġ voltage(Min.)ġ at ratedġ (V)ġ (mA)ġ (Ω)ġ at 85°Cġ at 23°Cġ at 23°Cġ voltageġ 5 180 27.8 6 150 40 150 % of 75 % of 10 % of 9 100 90 rated rated rated approx. 0.9W 12 75 160 voltage voltage voltage 24 38 640 48 19 2,560
Contact material AgSnO alloy Contact resistance (1) Operate time (1) 20ms Max. Release time (1) 10ms Max. Operating extremes 10 焍55Hz , amplitude 1.5 mm Vibration resistance Damage limits 10 焍55Hz , amplitude 2.0 mm Operating extremes 10G Shock resistance Damage limits 100G 5,000,000 ops. Mechanical (frequency 18,000 ops./hr) Life expectancy 100,000 ops. Electrical (frequency 360 ops./hr) Operating ambient temperature -40 焍+ 85°C (no freezing) Weight Approx. 22g 100mΩ Max. (at 1A/6VDC by 4-wire resistance measurement) Note 烉(1) Initial value. Operate and release time excluding contact bounce. (2) Unless otherwise specified, all tests are under room temperature and humidity. (3) Consider the heat of PCB is necessary, please check the actual condition of PCB. (4) Applying no diode to this relay. The life expectancy will be lower when a diode is used. To use a varistor (ZNR) could absorb the coil surge of relay that is recommended. (5) Do not use the relay exceeding the coil rating, contact rating and life expectancy, or this may cause the risk of overheating. (6) To assure optimum performance, avoid the relay from dropping, hitting, or other unnecessary shocks. (7) Do not switch the contacts without any load as the contact resistance may become increased rapidly. (8) Use suitable harnesses and bus bars according to the current as belowm 㕐㕐㕐25A typemMin. 6.0 mm (9) Usage, transport and storage conditions /g3/g3/g3/g3/g3/g3/g404/g3/g20/g17/g3/g55/g72/g80/g83/g72/g85/g68/g87/g88/g85/g72/g29/g3/g16/g23/g19 焍+85°C /g3/g3/g3/g3/g3/g3/g404/g3/g21/g17/g3/g43/g88/g80/g76/g71/g76/g87/g92/g29/g3/g24/g3/g87/g82/g3/g27/g24/g8/g3/g53/g17/g43/g17 /g3/g3/g3/g3/g3/g3/g404/g3/g22/g17/g3/g51/g85/g72/g86/g86/g88/g85/g72/g29/g3/g27/g25/g3/g87/g82/g3/g20/g19/g25/g3/g78/g51/g68 /g3/g3/g3/g3/g3/g3/g404/g3/g41/g88/g85/g87/g75/g72/g85/g80/g82/g85/g72/g15/g3/g87/g75/g72/g3/g75/g88/g80/g76/g71/g76/g87/g92/g3/g85/g68/g81/g74/g72/g3/g89/g68/g85/g76/g72/g86/g3/g90/g76/g87/g75/g3/g87/g75/g72/g3/g87/g72/g80/g83/g72/g85/g68/g87/g88/g85/g72/g17/g3/g54/g82/g15/g3/g88/g86/g72/g3/g85/g72/g79/g68/g92/g86 within the range indicated in the graph below. (10) Please contact Song Chuan for the detailed information. Tolerance range Humidity, /g8RH (Avoid freezing when used at temperatures lower than 0°C) (Avoid condensation when used at temperatures higher than 0°C ) Temperature, °C
Certified CSA / CUS TUV UL / CUL File No. 1 165173 R50003966 E88991 CSA / CUS TUV UL / CUL 25A 277VAC 25A 250VAC 25A 277VAC 20A 250VAC cosφ0.7 1.5HP 125V AC/250VAC1.5HP 125/250VAC 18FLA/98LRA 240VAC ˓891P (0.059) 1.5 (0.012) 0.3 (0.630) 9.4 (0.370) (1.181) (0.031) 0.8 (0.051) 1.3 26.8 (1.055) 23.2 (0.913)3.5 (0.138) 0.8 (0.031) Insulation Data Insulation of IEC 61810-1 Clearance / creepage distances Between coil to contact : Reinforce, ʁ!3.0mm / ʁ!5.0mm! Between open contact : Functional Rated insulation voltage 250V Rated impulse withstand voltage 2500V Pollution degree 2 Rated voltage 230 / 400V Overvoltage category II Insulation resistance (1) 1000 M Ω Min. (DC 500V) Between open contact : AC 1000V , 50/60Hz 1 min. Dielectric strength (1) Between contact and coil : AC 4500V, 50/60Hz 1 min. Notei(1) Initial value.
Ϭ891WP (1.087) 27.6 6.25 (0.246) (0.866) (0.472) 5.75 (0.226) (0.071) ͫ1.8-4 (1.181) 3 4 (0.630) 80.8 23.5 (0.925) (0.031) (0.315) 3.4 (0.134) 6.35 (0.250) (0.051) (0.138) 3.5 1.3 (0.031) 0.8 0.8 (0.031) (0.031) 0.8 (0.059) 0.3 (0.012) 1.5 6.6 (0.260) (0.728) 18.5 MORE THAN: 20(0.787) ±1(0.039) LESS THAN: 1(0.039) ±0.1(0.004) TOLERANCE:
————/g3/g36/g79/g79/g3/g86/g83/g72/g70/g76/g191/g70/g68/g87/g76/g82/g81/g86/g3/g86/g88/g69/g77/g72/g70/g87/g3/g87/g82/g3/g70/g75/g68/g81/g74/g72/g17/g3/g3/g3/g3/g3/g3/g51/g79/g72/g68/g86/g72/g3/g70/g82/g81/g87/g68/g70/g87/g3/g54/g82/g81/g74/g3/g38/g75/g88/g68/g81/g3/g73/g82/g85/g3/g88/g83/g71/g68/g87/g72/g17/g3———— 891 Engineering Data Life expectancy AC resistive load/Switching current(A) Number of operations 51 0 1 5 2 0 25 250VAC Temperature rise (ʨ) % of Nominal Coil Voltage (at 23ʨ) 1008060 160 140120 180 Coil temperature rise 100 120 % of Nominal Coil Voltage (at 85ʨ) Temperature rise (ʨ) 8060 120 100 140 160 180 Coil temperature rise 25A 20A 25A 20A % of Nominal coil voltage (at 23ʨ) avg min max Operate time/Release time 14013012011090 100 Time (ms) 70 80 150 min avg max Operate time Release time 180160 170