Product: 8772NH Electronic, 3C #20 Str TC, PO ins, OS, LSNH Jkt 300V Product Description Electronic, 3 Conductor AWG 20 Tinned Copper - Stranded, Polyolefin (PO, PE, PP) insulation, Foil(s) or Copper Tape(s) shielding, LSZH / FRNC jacket , 300V Technical Specifications Product Overview Suitable Applications: Instrumentation and computer cable; For data transmission applications Physical Characteristics (Overall) Conductor AWG Stranding Material No. of Conductors 20 7x28 TC - Tinned Copper 3 Conductor Count: 3 Insulation Material Nominal Diameter Diameter +/- Tolerance Nominal Wall Thickness PE - Polyethylene 1.78 mm 0.05 mm 0.017 in Color Chart Number Color Wire 1 Black Wire 2 Red Wire 3 Clear Outer Shield Type Material Material Trade Name Coverage [%] Thickness of Foil Drainwire Material Drainwire AWG Drainwire Construction n x D Tape Bi-Laminate (Alum+Poly) Beldfoil® (Z-Fold®) 100% 9 / 12 µm TC - Tinned Copper AWG20/7 7x28 Outer Jacket Material Nominal Diameter Nominal Wall Thickness LSZH - Low Smoke Zero Halogen (Flame Retardant) 5.65 mm 0.9 mm Construction and Dimensions Cabling Description Twists 3 wires twisted to cable core 6 twist/ft
Electrical Characteristics
Nominal Conductor DCR Nominal Outer Shield DCR 34.5 Ohm/km 30.8 Ohm/km Capacitance
Nom. Capacitance Conductor to Conductor Nom. Capacitance Conductor to Other Conductor to Shield 88.6 pF/m 167.3 pF/m Impedance Nominal Characteristic Impedance
69 Ohm
Nominal Velocity of Propagation (VP) [%] 66% Current Element Max. Recommended Current [A] Conductor(s) 4 A Voltage Voltage Rating [V] 300 V Temperature Range Installation Temperature Range: -15°C To +80°C Storage Temperature Range: -30°C To +80°C Operating Temperature Range: -15°C To +80°C Operating Temp Range (Fixed Install): -15°C To +80°C Mechanical Characteristics Oil Resistance: IEC 60811-404 Bulk Cable Weight: 28 lbs/1000ft Max. Pull Tension: 180 N Min. Bend Radius During Installation: 56.5 mm Min. Bend Radius/Minor Axis: 2 in Standards CPR Euroclass: Dca-s1,d1,a1 CENELEC Compliance: EN 50290-2-20 Applicable Environmental and Other Programs Environmental Space: Indoor - Euroclass Dca EU Directive Compliance: EU Directive 2003/11/EC (BFR) EU CE Mark: Yes MII Order #39 (China RoHS): Yes Suitability Suitability - Indoor: Yes Suitability - Non-Halogenated: Yes Flammability, LS0H, Toxicity Testing IEC Flammability: IEC 60332-1-2, IEC 60332-3-24 IEC 60754-1 - Halogen Amount: Zero IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity: 2.5 µS/mm IEC 60754-2 - Halogen Acid Gas Amount - Min. pH: 4.3 IEC 61034-2 - Smoke Density Min. Transmittance: 60% Plenum/Non-Plenum Plenum (Y/N): No Related Part Numbers Variants Item # Color Put-Up Type Length EAN 8772NH.00500 Blue Reel 500 m 8719605019448
8772NH.001000 Blue Reel 1,000 m 8719605019431 8772NH.01152 Chrome Reel 152 m 8719605019462 8772NH.01500 Chrome Reel 500 m 8719605019479 8772NH.011000 Chrome Reel 1,000 m 8719605019455 History Update and Revision: Revision Number: 0.300 Revision Date: 12-20-2022 © 2023 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product.