851 SOURIAU | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 7

Technical content

Glass to metal sealing. Helium leakage of less than 10-7 atm.cm3/s. Pressure resistant. Standard Connector Hermetic Connector 30% Shorter Hermeticity and compacity applied to a world wide proven connector series. Hermetic and Small Bayonet Connectors Per MIL-DTL-26482 Series I

851 Series

Compact design No rear accessory thread and no grommet. Easy use Quick bayonet coupling.

851 Series | Hermetic Connectors

Description

  • Glass sealed hermetic
  • Compact low profile - 30% shorter than the standard version
  • Quick bayonet coupling per: - MIL-DTL-26482 Series I - HE301 - VG95328
  • Solder cup contactsTechnical features Materials
  • Shell: Steel
  • Plating: Iridescent yellow cadmium Nickel
  • Contact: Gold plated ferrous alloy
  • Seal: Fluorocarbon elastomer Electrical
  • Max current rating per contact:
  • Dielectric withstanding voltage:
  • Contact resistance: Size 20 ≤ 30 mΩ Size 16 ≤ 14 mΩ
  • Shielding: 70 dB to 5 MHz 40 dB to 100 MHz Environmental
  • Operating temperature: -55°C to +125°C
  • Hermeticity: 1 bar differential pressure, leakage ≤ 2.8 mm 3/hr
  • Salt spray: 48 hours min
  • Chemical resistance: To MIL-DTL-26482G Series I
  • Damp heat: 21 days Contact size 20 16 12 Rating (A) 5 10 17 Service Standard pressure 10 mbar pressure I 1 500 Vrms 200 Vrms II 2 300 Vrms 300 Vrms

3 #16 Service II 8 #20 Service I 10 #20 Service I 5 #16 Service II 19 #20 Service I 8 #20, 4 #16 Service I 32 #20 Service I 26 #20 Service I 8 #16 Service II 6 #20 Service I Contact #20 (Ø1) Contact #16 (Ø1.6) 61 #20 Service I 55 #20 Service I 37 #20, 2 #16 Service I 41 #20 Service I 3 #20 Service I 4 #20 Service I 3 #20 Service I 08 10 12 14 16 18 20 22 24

Ordering information

Basic series 851 02H 18 32 P 50 Shell type: IH: Solder mount receptacle 02H: Square flange receptacle 07H: Jam nut receptacle Shell size: 08, 10, 12, 14, 16, 18, 20, 22, 24 Contact layout: See previous page Contact type: P: Pin Orientation: None: Normal (N) W, X, Y, Z - see page 7 Mandatory suffix: 50: Gold plating for contact size 20 and size 16 Specification: None: Yellow cadmium plating - 02H and 07H only Nickel plated - IH only 44: Nickel plated - 02H and 07H only VG95328 qualified products Basic series VG95328 F 18 32 P N Shell type: G: Solder mount receptacle F: Jam nut receptacle Shell size: 08, 10, 12, 14, 16, 18, 20, 22, 24 Contact layout: See previous page Contact type: P: Pin Orientation: N, W, X, Y, Z - see page 7 SOURIAU part numbers

Maximum connector weights (in grams)

  • • Shell size ° ° Layout □ Orientation. Empty if orientation N - only for «Souriau», «NFC93422» and «MIL-DTL-26482G Series I» SOURIAU NFC 93422 HE 301B MIL-DTL-26482G Series I Not QPL 851 02H • • ° ° P □ 50 HE 301 B 02 H • • ° ° P □ 3A - 851 07H • • ° ° P □ 50 HE 301 B 07 H • • ° ° P □ 3A MS 3114 H • • C ° ° P □

851 IH • • ° ° P □ 50 HE 301 B 1 H • • ° ° P □ 3A MS 3113 H • • C ° ° P □

Shell type 8 10 12 14 16 18 20 22 24 Solder mount receptacle (type IH) 7 9 13 17 21 26 32 37 43 Square flange receptacle (type 02H) 10 12 16 21 26 33 41 47 55 Jam nut receptacle (type 07H) 20 25 38 45 52 63 86 96 115 Contact layouts (matrix) Shell size Layout Hermetic 851 Hermetic MIL-DTL-26482G Hermetic VG95328 Number of contacts #20 #16 8-3A 3 Q 3 8-98 3 3 8-33 3 3 3 8-4 3 3 4 10 10-6 3 3 Q 6 12-3 3 3 Q 3 12-8 3 3 8 12-10 3 3 Q 10 14-5 3 3 Q 5 14-12 3 3 Q 8 4 14-15 3 3 Q 14 1 14-19 3 3 Q 19 16-8 3 3 Q 8 16-26 3 3 Q 26 18 18-32 3 3 Q 32 20-39 3 3 Q 37 2 20-41 3 3 Q 41 22 22-55 3 3 Q 55 24 24-61 3 3 Q 61

Note: All dimensions are in millimeters (mm) Solder mount receptacle (type IH) Square flange receptacle (type 02H) ØA D ØGB C F ØH ØE ØA D ØK B C F ØL ØE G G H ØJ H ØL H H ØJM Shell size A B C max D max E max F max G max H ±0.1 Shell size A B C max D max E F max G max H J K max L ±0.1 M min Dimensions

WPN851HWUSEN02 © Copyright SOURIAU Jul 2014 - SOURIAU is a registered trademark. All information in this document presents only general particulars and shall not form part of any contract. All rights reserved to SOURIAU for changes without prior notification or public announcement. Any duplication is prohibited, unless approved in writing. For further information contact us at contactmilaero@souriau.com or visit our web site www.souriau.com Note: All dimensions are in millimeters (mm) ØA ØK B C F E H J ØD E ØG Shell size A B max C max D E max F G max H min H max J ±0.1 K ±0.1 Jam nut receptacle (type 07H) Orientation Shell size Layout Angle in degrees W X Y Z 4 45 - - - 33 90 - - - 3A 60 210 - - 10 6 90 - - - 3 - - 180 - 8 90 112 203 292 10 60 155 270 295 Shell size Layout Angle in degrees W X Y Z 5 40 92 184 273 12 43 90 - - 19 30 165 315 - 16 8 54 152 180 331 26 60 - 275 338 18 32 85 138 222 265 20 41 45 126 225 - 22 55 30 142 226 314 24 61 90 180 270 324 Polarization code Viewed from receptacle front face. Insulator rotated inside metal body. Angle